Tender For Provision Of Some Minor Works At Af Station Jaipur
Tender Value
8.51 Lakhs
Estimated cost
Bid Submission
23 Nov 2026
13 days left
EMD
17020
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jaipur → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provision Of Some Minor Works At Af Station Jaipur
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed |
| 2 | Dismentaling Plain or corrugated steel sheeting,fiber sheet any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed |
| 3 | Demolition of Concrete (un reinforced)in ground floor and pavings n exc 15 cm complete all as specified and directed |
| 4 | Taking down Chowkatts or frames n exc 1.5 sq m each with shutters (without taking off shutters form the frames) complete all as specified and directed |
| 5 | Taking down Chowkatts or frames exc 1.5 sq. m but n exc 4 sq m each with shutters (without taking off shutters from the frames) complete all as specified and directed |
| 6 | Taking down cement or lime plaster of any description complete all as specified and directed |
| 7 | Material and labour for Brick work with sub class 'B' bricks, Straight or curved on plan exc. 6 m mean radius built in CM 1:6, complete all as specified and directed. |
| 8 | M&L for rendering 15 mm thick on fair faces of brick or stone masonary in CM (1:6) finished even and smooth without using extra cement complete all as specified and as directed. |
| 9 | M&L for rendering 15 mm thick on fair faces of brick or stone masonary in CM (1:4) finished even and smooth without using extra cement complete all as specified and as directed. |
| 10 | M & L for preparation of newly plastered previously untreated surfaces of walls and applying two coats of distemper oil emulsion over and including a coat of average 2 mm thick wall care putty and one coat of primer complete all as specified and directed. |
| 11 | M&L for preparation of newly plastered surfaces of wall and applying 2 mm thick water proofing wall care putty and applying two or more coats of 100% premium acylic emulsion paint having VOC less than 50 gms/litre and UV resistance as per IS 15489:2004, alkaly & fungal registance, dirt resistance exteriour paint of required shade (company Depot Tinted) with silicon additives @ 1.43 litre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 Sqm over new surfaces complete all as specified and directed. |
| 12 | S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc conforming Fe 410 -W (Gde E- 250) quality A complete all as specified and directed |
| 13 | S&F for pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to walls, fixed with self tapping screws complete all as specified and directed. |
| 14 | S&F powder coated aluminium (minimum thicknessof powder coating 50 micron) work for doors, windows, ventilators, fixed/sliding (upto three track) including providing and fixing hinges/pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (fittings shall be paid for seperately) with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS-733 and IS-1285, fixing with dash fasterners of required dia and size including necessary filling up the gaps at junction i.e at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing/peneling, CP brass/stainless screws all complete as per architectural drawings complete all as specified and directed |
| 15 | S&F anodized aluminium grill (anodized transparent or dyed to required shade accoring to IS : 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing windows frame with CP brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening szie for fixing and operation of handles and fixing approved anodized aluminium standard section around the opening, complete all as specified and directed. |
| 16 | S&F for 4.8 mm thick sheet glass, ordinary quality, Nexc 0.50 Sqm in each pane, glazing with beads fixed with metal panel pins complete all as specified and directed. |
| 17 | S&F for 5.5 mm thick sheet glass, ordinary quality, exc 0.50 Sqm in each pane, glazing with beads fixed with metal panel pins complete all as specified and directed. |
| 18 | M&L Cement concrete type B-0, 1:2:4 (12.5 mm graded aggregate) avg. 25 mm thick in levelling course for laying floor finish complete. |
| 19 | M&L for 20 mm thick granite stone slab (table rubbed and polished) as on shelves/cooking plateform/pillars/riser over and including screed bed 20 mm thick in CM (1:4) set jointed in neat cement slurry and pointed in white/coloured cement to match the shade including grinding and polishing complete all as specified and directed. |
| 20 | M&L for 20-25 mm thick, machine cut kota stone slab flooring 20-25 mm thick over and including 15 mm thick screed bed in CM 1:6, laid and jointed with grey cement slurry mixed with pigment to math the shade of the slab including rubbing and polishing complete all as specified and directed. |
| 21 | Providing & fixing false ceiling with fully perforated 12 mm thick micro tegular eged or 10 mm thic square edgd GRG false ceiling all heights with GRG (Glass fibre reinforced Gypsum) false ceiling tiles of size 595 x 595 of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRCO 0.5 to 0.75 as per IS 8225 : 1987, Noncombustible (Fire resistant/retardant) as per BS-476 (Part4)-1970, fire resistant/retardant and light relectance of 85% (minimum) to be laid in true horizontal level suspended on and including interlocking metal T-Grid of hot dipped galvanized iron section 0.33 mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main 'T' runners of size 15 x 32 mm of length 3000 mm, cross-T of size 15 x 32 mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600 mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per Sqm) i.e 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully thread hanger rod upto 1000 mm length and L-shape level adjuster of size 85 x 25 x 2 mm, galvanized iron parimeter wall angle of size 24 x 24 x 0.40 mm of length 3000 mm to fixed on periphery wall/partition with the help of plastic rawl plugs at 450 mm centre to centre and 40 mm long dry wall wood screws. The work shall be carried out as per specifications, drawings and as per directions of Engineer-in-Charge. |
| 22 | M&L preparation of old steel surfaces and applying two coats of synthetic enamel paint exceeding 10 cm width or girth complete all as specified and directed. |
| 23 | M&L preparation of new steel surfaces and applying two coats of synthetic enamel paint exceeding 10 cm width or girth over a coat of red oxide primer complete all as specified and directed. |
| 24 | M & L for Non skid ceramic coloured tiles 7 to 8 mm thick (Square or Rectangular) area of each tile exc.0.11 sqm but not exc 0.18 Sqm,, as in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile with and including 15 mm thick screed bed or bedding layer of cement mortar 1:6 for laying floor finishes complete all as specified and directed. |
| 25 | M&L for light shade Ceramic tiles 7 to 8 mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm, in vertical surfaces etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile with and including 10 mm thick rendering in cement mortar 1:4 complete all as specified and directed. |
| 26 | Demolition of brick work or stone / boulder masonry including all quoins, arches, pillars, etc. built in cement mortar or cement lime mortar complete all as specified and directed |
| 27 | Material and labour for Brick work with sub class 'B' bricks, Straight or curved on plan exc. 6 m mean radius built in CM 1:4, mixed with water proofing liquid compound 250 ml per bag as per manufacturer's instruction over the surface complete all as specified and directed. Note: WPC shal be measured and paid separately. |
| 28 | Supply only liquid water proofing compound. |
| 29 | M&L for 20 mm thick granite stone slab (table rubbed and polished any coloure) as on Wall/shelves/ plateform over and including like cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. |
| 30 | Taking up or down steel tubing and connections including cleaning for refixing or removal to store in 20 mm bore. |
| 31 | S & F of 20 mm bore steel water tubing medium grade galvanised with and including all fittings and fixed to walls and ceilings or laid under floors complete all as specified and directed. |
| 32 | M&L for Providing, supplying, carving, polishing, fixing, testing and commissioning of 6 ft height with 3 tier basin decorative vertical white marble fountain, comprising suitabaly selected good quality natural white marble of approved shade, texture and finish, with carved/moulded marble componenets, water collection basin, supporting structure, necessary marble cladding, waterproofing treatment and all accessaries. The fountain shall include a suitable closed-loop water circulation system comprising, SS/brass water nozzles, UPVC/GI/SS piping, valves, stainer/filter, concealed connections and all necessary fittings. Note : (i) Rate quoated shall be deemed to include for supplying, fixing, commossioning, transporting etc. |
| 33 | S&F 50 mm dia GI RING FOUNTAIN RING 4 to 5 feet long connect to GI pipe of 15 -20 mm etc complete all as specified and directed |
| 34 | S&F Bell Jet Nozzle, Material: Brass with Chrome, Size 1 Inch fitted in fountain etc complete all as specified and directed |
| 35 | S&F Foam Jet Nozzle 2.5 cm inlet (1 inch) Material: Stainless Steel placed in level of floor complete all as specified and directed |
| 36 | S&F Ball Joint 1 inch Material: Brass with Chrome fixed and complete all as specified and directed |
| 37 | S&F Valve Joint, material: Brass with Chrome fixed and complete all as specified and directed |
| 38 | PLUMBING WORK Includes uPVC pipes, Elbow, T joints, etc required for the water Foam Jet and Truss for the water fall fountain in the waterbody complete all as specified and directed |
| 39 | S&F SUBMERSIBLE 3 HP PUMP SET, Body: Stainless Steel Body FOR WATERFALL and fixed to fountain complete all as specified and directed |
| 40 | NOZZLE MOUNTED LIGHT, IP68 Water Resistant Body : SS Color: Warm White and fixed to fountain complete all as specified and directed |
| 41 | S&F SS LIGHT 9W FOR Water Highlight, IP68 Water Resistant Stainless Steel 304 Color: Warm White Four for Fountain Highlight complete all as specified and directed |
| 42 | S&F MASTER ELECTRIC CONTROL PANEL Motors (3HP) and Lights complete all as specified and directed |
| 43 | S&F Controller and Power Supply For powering and Controlling DC Lights complete all as specified and directed |
| 44 | S&F ELECTRIC WORK IN WATER BODY Counduiting with tin/silver plated 4 core wire and other electric work in the fountain Waterbody. Water Proofing of Wire Joints for lights and motors and electrical equipments complete all as specified and directed |
| 45 | M&L for rendering 15 mm thick on fair faces of brick or stone masonary in CM (1:4) finished even and smooth without using extra cement complete all as specified and as directed. |
| 46 | M&L for PCC 1:3:6 type C-2, using 40 mm graded stone aggregate as in pillars, boundary pillars and fencing post or similar work complete all as specified and directed. |
| 47 | M & L for point wiring complete with 1100 Volts grade PVC insulated unsheathed copper conductor cable (FRLSH) multistranded of size 1.5 Sqm single core in an including ERW steel conduit, ISI marked surface mounted of suitable size with all accessories and continuous earth wire of size 1.5 sqmm PVC copper conductor cable connected to common earth dully complete all as specified and directed for the following :- (a) One light point controlled by one MCB SP. |
| 48 | (b) One 5 amps socket point controlled by one MCB SP. |
| 49 | (c) One Exhaust fan point controlled by one MCB SP. |
| 50 | M & L for point wiring complete with 1100 Volts grade PVC insulated unsheathed copper conductor cable (FRLSH) multistranded of size 2.5 Sqm single core in an including ERW steel conduit, ISI marked surface mounted of suitable size with all accessories and continuous earth wire of size 2.5 sqmm PVC copper conductor cable connected to common earth dully complete all as specified and directed for the following :- (a) One 15 A socket point controlled by one MCB SP. |
| 51 | S & F for Switch flame proof rotary type with termination box in LM6, 16A, single pole 250 Volts duly certified by CMRI Dhanbadcomplete all as specified and directed |
| 52 | S & F for Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth duly certified by CMRI Dhanbad complete all as specified and directed |
| 53 | S & F for Flame proof brass unions suitable for 20 mm ERW conduit duly certified by CMRI Dhanbad complete all as specified and directed |
| 54 | S & F for Flame proof brass bends suitable for 20 mm ERW conduit duly certified by CMRI Dhanbad complete all as specified. |
| 55 | S & F for Flame proof closing plugs suitable for ERW 20 mm dia conduit duly certified by CMRI Dhanbad complete all as specified and directed . |
| 56 | S&F flame proof /Weatherproof 4 way junction box with 4 Nos terminal for looping in and looping out connections, duly certified by CMRI Dhanbad complete all as specified and directed |
| 57 | S & F for Flame proof weather proof fitting 1x 16 watt LED type duly certified by CMRI Dhanbad ccomplete all as specified and directed |
| 58 | M & L for surface flame proof Sub main wiring with 2 run of 4.0 Sqmm single core, PVC insulated unsheathed multistranded with copper conductor cable, 1100 Volts FRLS-H grade ISI marked drawn through in and including ERW steel conduit with flame proof accessories and including one run of 4. Sqmm FRLS-H PVC insulated single core cable unsheathed stranded copper conductor cable green in colour for earth continuity conductor complete all as specified and directed. Note :- (i) Two runs single core cable and one run single core cable of earth wire and one run of ERW steel conduit pipe shall be measured as one length. (ii) Flame proof accessories such as Junction box, unions and bends shall be measured and paid seperately. |
| 59 | S&F flame proof/weather proof exhaust fan of 300 mm (12\\") sweep with 0.25HP motor, 230 volts single phase, 50 Hz, with provn pf louvers and bolts nuts and washers including flame proof flexible metallic conduit with necesary electrical connections complete all as specified and as directed. |
| 60 | S&F flame proof Sheet steel metal enclosure with distribution box ,SPN 6 Way 240 Volts with MCB 2 Pole, 25 Amps-1 No, Outgoing MCB SP, 240 Volts 5-32 Amps- 04 Nos complete with internal Bus Bar & wiring upto terminal, duly certified by CMRI Dhanbad complete all as specified and directed |
| 61 | M&L earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground vertically to a depth not less than 2.25m below ground level with top edge of the earth plate at a depth not less than 1.5m below ground level, connected to galvanised earth lead wire 25 x4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel and other end of earth wire connected to main switch board and protected by galvanised iron pipe light grade 25mm bore and water pipe 25 mm bore GI light grade with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover with handle all as specified and shown in elect plate No 3 of SSR Part-I of 2020 earthing complete all as specified and directed. |
| 62 | M&L GI strip lead 25 x 4mm on saddle complete as specified and directed. |
| 63 | M&L air termination rod Aluminium single pointed 12mm dia, 300 mm long complete as specified and directed. |
| 64 | Supply and fix medium grade 50 mm galvanised ISI marked pipe with all fittings and accessories complete to walls and ceilings or laid in floors/trenches/under road complete all as specified and directed by the engineer-in-charge. |
| 65 | Supply and fixing gate valve 50 mm, with iron handle, screwed both ends for iron pipe or for union and fixing valves complete all as specified and directed. |
| 66 | S&F sluice valve class PN 1.6 of size 80 mm |
| 67 | S&F NRV valve class PN 1.6 of size 80 mm |
| 68 | S&F medium grade GI ISI marked equal tee of 50 mm. |
| 69 | S&F of medium grade GI ISI marked elbow of 50 mm. |
| 70 | Excavation in trenches not exc 1.5 mtrs wide & not exc 1.5 mtrs in depth for taking out/laying of pipes/cables etc & getting out in Hard/Dense soil complete all as specified and directed . |
| 71 | Returning, filling in trenches, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed. |
| 72 | Removing excavated materials not exceeding 50 mtrs away and depositing where directed at a level not exceeding 1.5 mtrs above the starting point complete all as specified and directed . |
| 73 | M&L PCC 1:2:4 with 20 mm graded aggregate for prepration of column for water supply pipe line. |
| 74 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises |
| 75 | M&L for Cement concrete type C-2,1:3:6 (20 mm graded aggregate) 100 mm Thick complete all as specified and directed |
| 76 | M&L for Sand filling under floors/Blocks or in foundations including watering and consolidation complete all as specified and directed |
| 77 | S&F Chequered cement concrete tiles with grey cement and pigments 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors complete all as specified and directed |
| 78 | S&F for RRL hose type - A 15 m with accessories complete all as specified and directed |
| 79 | S&F Pressure gauge 4\\"dial 0-14 kgs rating with accessories complete all as specified and directed Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 02, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 23, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysNov 28, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender