Tender For special Repair To Street Light System From Main Gate To Arjun Gate At Kms.
Tender Value
Ref. Documents
Estimated cost
Bid Submission
21 Nov 2026
9 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kota → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for special Repair To Street Light System From Main Gate To Arjun Gate At Kms.
BOQ
| Sl. No. | Item Description |
| 1 | M & L for auguring under road, pavement, hard standing, railway lines by trenchless technology using latest boring technique and necessary machine including insertion of HDPE pipe upto 90 mm dia for protection of LT cable and including taking necessary permission from Railway/ MSEDCL/ any other department complete all as specified and as directed. Note : HDPE pipe shall be measured and paid separately. |
| 2 | Dismantling ACSR or AAC conductors removing to store or taken on schedule of credit complete all as specified and as directed. |
| 3 | Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 4 core, nominal cross sectional area of main conductor 16 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed. |
| 4 | Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 4 core, nominal cross sectional area of main conductor 25 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed. |
| 5 | M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 4.0 mm dia galvanised mild steel wire by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed. |
| 6 | M & L for steel tubular swaged pole 410 SP-31 (9.0 metre long) double swan neck brackets of suitable size as approved by EIC including CI base plate, finial taper plug, bolts, nuts & screws as per IS 2713 Part -I & II including preparing and painting on steel tubular swaged pole 410 SP-31 (9.0 metre long) including cross arms, PCC coping incl taking out old existing pole with all accessories complete all as specified and as directed. comprising the following: -(a) Two coats of synthetic enamel paint in white colour over a coat of primer on PCC coping (b) Making 4 Nos of strips of 30 cm wide in alternate red and white colour using two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer (c) Providing 30 cm wide retro reflective sheet of 30 cm wide, grade 1, pressure bonding type, red colour as per IS 14221: 1995 (d) Two coats of synthetic enamel paint in red colour over a coat of primer from top of electric pole to downward upto 1 metre length including cross arms, GI brackets etc. (e) Writing pole number and voltage level encompassed by circle of suitable dia using two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer (the colour of base shall be black and the colour of font shall be white). Number and voltage level shall be handwritten, and circle shall be stencilled. (f) Painting with two coats of aluminium paint over a coat of aluminium red oxide primer on remaining exposed portions |
| 7 | S & F LED motion sensor street lights nominal power 120 Watt, Initial level when switched on 100% brightness and when no motion detected light level dimmed to 50% , operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 16200, lumen efficacy of minimum 175 lumens per watt, built-in electronic driver with APFC, lower THD, output open /short circuit protection, phase to phase protection, Low and over voltage cut-off, surge voltage protection upto 10 KV with SPD, protection grade IP 66, CRI greater than 80%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with polyester powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hours & including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 15885 complete all as specified and as directed. |
| 8 | S&F Junction box made out of 2mm thick CRCA sheet of size 50mmx250mmx150mm with hinged door and locking arrangement including aluminium bus bar of size 25x3mm three phase & Neutral fixed on insulator, including one No MCB SP 6 amps & painting a box with two coats of synthetic enamel paint over coat of red oxide primer all as specified and as directed. |
| 9 | S & F three core flexible conductor FR-LSH cables for outdoor use, PVC insulation of type C and having PVC sheath of type ST2, 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor for fittings complete all as specified and as directed. |
| 10 | Supply & fixing of feeder pillar box of outdoor type fabricated out of 3.15 mm thick CRCA sheet double door(front & back opening), CPRI approved complete with powder coating with seven tank process mounted on M.S angle Iron frame of size 40x40x6mm, duly grouted with PCC reqd with the following:-(a)Aluminium bus bar 250 Amp (R Y B & N) with coloured heat shrinkable insulated sleeve 415 Volts as per IS of suitable size mounted on DMC/epoxy insulator (not less than 50mmx50mm conicle type at a maximum interval of 500 mm- 01 Set.(a) MCCB FP 40 Amps, 415 V, 25 KA - 01 No for main in coming (b) MCB TPN 63 Amps 415 V FP, 16 KA - 02 Nos (c) MCB SP 10 A 10 kA-01 Nos(d) LED indicator for RYB of size 22.5 mm - Set of 3(e) Multifunctional meter for freq, power factor, amperes, voltage etc. - 01 set (f) Street light timer using Power contactor 32 Amps, (1-NO), 3 pole, 415Volt, DIN type digital programable time switch 230V AC, Auto/Manual selector switch, MCB TPN, 32 Amps, ON/OFF indicator all prewired and making provision for fixing outgoing cables - 01 Set complete.Note: All MCCBs must conforms Fixed thermal and fixed thermal magnetic setting and Ics= 100% of IcuNote: Leg height of angle iron frame for panel must not be less than 100 cm above the PCC base to avoid water logging. |
| 11 | M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 25 mm X 4 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed. |
| 12 | Supplying & laying in trenches 50 mm nominal bore, light grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. |
| 13 | Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed. |
| 14 | Excavating in trenches not exceeding 1.5 m wide and exceeding 1.5 m but not exceeding 3.0m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and exceeding 1.5 m but not exceeding 3 m in depth and getting out in soft/ loose soil complete all as specified and as directed. |
| 15 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed. |
| 16 | Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 17 | Supply only high density polyethylene pipe (HDPE) (DWC) of pressure rating PN 8 (SDR 17), material grade PE 100and nominal diameter 63 mm including all fittings and fixtures for insertion into horizontal boring/ floor/ wall with necessary fixing arrangements as in cable protection complete all as specified and directed. |
| 18 | M & L for cement concrete in foundation, filling and mass concrete in M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 02, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 21, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysNov 28, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓
Disclaimer