Tender For Repair/Replacement Of Unserviceable Submain Wiring, Point Wiring, Switches, Sockets, Earthing For Building, Unserviceable Distribution Board, Industrial Sockets, Bldg Security Lights, Including Allied Work At Hight Raised Bldg At Nofra And
Tender Overview
Project Description
Tender for Repair/Replacement Of Unserviceable Submain Wiring, Point Wiring, Switches, Sockets, Earthing For Building, Unserviceable Distribution Board, Industrial Sockets, Bldg Security Lights, Including Allied Work At Hight Raised Bldg At Nofra And Other Md Accomdation Under Ge(Nw) Nofra.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 04-Nov-2026 | CorrigendumBOQ | BOQ | 21-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Taking down carefully aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators sockets etc to be measured separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified. |
| 2 | Material and Labour for point wiring complete with 1.5 sqmm single core multistranded FRLS PVC insulated unsheathed copper conductors 1100 volts grade drawn through and including PVC non-metallic casing and caping of size not less than 25mm width, ISI marked with accessories fixed on wall/ceiling/truss etc with PVC non metallic ISI marked terminal boxes/ modular Cover plate concealed in wall including one FRLS PVC insulated & sheathed multistranded green colour copper conductor 1.5 sqmm as earth continuity conductor connected to common earth as earth dolly for :- |
| 3 | One light point/fan point controlled by one switch SP one way. |
| 4 | One 3 pin socket outlet 5Amps on independant board. |
| 5 | One 3 pin socket outlet 5Amps on same board with other switches. |
| 6 | One bell point controlled by one bell push 5 Amps. |
| 7 | Material and Labour for point wiring complete with 2.5 sqmm single core multistranded FRLS PVC insulated unsheathed copper conductors 1100 volts grade drawn through and including PVC non-metallic casing and caping of size not less than 25mm width, ISI marked with accessories fixed on wall/ceiling/truss etc with PVC non metallic ISI marked terminal boxes / modular Cover plate concealed in wall including one FRLS PVC insulated & unsheathed multistranded green colour copper conductor 2.5 sqmm as earth continuity conductor connected to common earth as earth dolly. |
| 8 | Supply and fix in repair Modular Switch, 6Amp, One way, 1 module. |
| 9 | Supply and fix in repair Modular Switch, 16Amp, One way, 1 module. |
| 10 | Supply and fix in repair Modular type bell push , 6Amp, 1 module. |
| 11 | Supply and fix in repair Bell electric AC 230Volt single pole musical type with ISI mark. |
| 12 | Supply and fix in repair Modular type, electronic fan regulator (5 step), 450 Watts, 230 volts, 2 module |
| 13 | Supply and fix in repair ceiling rose surface bakelite with ISI mark, flush type with ISI mark three terminals complete all as specified. |
| 14 | Supply and fix in repair Modular Socket oulet, 6 Amps, 2/3 pin combined, 2 module. |
| 15 | Supply and fix in repair Modular Socket oulet, 6/16 Amps, 2/3 pin combined, 2 module. |
| 16 | Supply and fix in repair Modular white cover plate with Frame 1 Module. |
| 17 | Supply and fix in repair Modular white cover plate with Frame 2 Module. |
| 18 | Supply and fix in repair Modular white cover plate with Frame 3 Module. |
| 19 | Supply and fix in repair Modular white cover plate with Frame 4 Module. |
| 20 | Supply and fix in repair Modular white cover plate with Frame 6 Module. |
| 21 | Supply and fix in repair Modular white cover plate with Frame 8 Module. |
| 22 | Supply and fix in repair Modular white cover plate with Frame 12 Module. |
| 23 | Supply and fix in repair Modular metal flush box 1 module. |
| 24 | Supply and fix in repair Modular metal flush box 2 module. |
| 25 | Supply and fix in repair Modular metal flush box 3 module. |
| 26 | Supply and fix in repair Modular metal flush box 4 module. |
| 27 | Supply and fix in repair Modular metal flush box 6 module. |
| 28 | Supply and fix in repair Modular metal flush box 8 module. |
| 29 | Supply and fix in repair Modular metal flush box 12 module. |
| 30 | Supply and fix in repair Linear polycarbonate PVC Baten LED T/L 20W polycarbonated Extruded Chanel Powder Coated with opaque diffuser for glare free light(Cool White) complete with accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified. |
| 31 | Supply and fix in repair Linear Polycarbonated PVC Baten LED T/L 20W Polycarbonate Extruded Chanel Powder Coated with opaque diffuser for glare free light (Warm White) complete with accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified. |
| 32 | Supply and fix in repair Linear polycarbonate PVC LED T/L 10W polycarbonated Extruded Chanel Powder Coated with opaque diffuser for glare free light (Cool White)complete with accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified. |
| 33 | Supply and fix in repair Linear aluminium Baten, inbuilt sensor based on smart LED auto dimmable from 100% of rated wattage to 30% on sensing of movement/occupancy, baten 20W Aluminium Extruded Chanel Powder Coated with opaque diffuser for glare free light complete with accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified. |
| 34 | Supply and Fix in repair batten intergrated LED channel 1x12 WH, flexible neck for adjusting beam, bronze finish for superior feel, 3000K with warm white (Color rendering CRI>8) complete accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engineer-in-Charge. |
| 35 | Material and Labour in repair for Lamp holder, PVC /Polycarbonate type with cord grip cap suitable for pendant fittings complete all as directed by Engineer-in-Charge. |
| 36 | Supply and fix in repair LED lamp of 14 watts, 240 volts, single phase, 50 Hzs, Lumen 1450 AC supply(Cool White). |
| 37 | Supply and fix in repair LED lamp of 14 watts, 240 volts, single phase, 50 Hzs, Lumen 1450 AC supply (Warm White). |
| 38 | Supply and fix in repair Plug and Socket enclosure, in sheet metal enclosure with MCB, SP 20 Amps 240 Volts complete with metal clad socket for air conditioners all as specified and directed by engr-in-charge. |
| 39 | S&F in repair Switch 5 Amps piano type, single pole 230 Volts complete all as specified and directed. |
| 40 | S&F in repair switch socket combination multipurpose for 3/2 pin 5 Amps flush type ISI marked complete all as specified and directed. |
| 41 | S&F in repair switch socket combination multipurpose 3/2 pin for 15 Amps controlled by one switch flush type complete all as specified and directed. |
| 42 | Supply and fix in repair sheet metal enclosure 12 way Double door type having protection IP-54, with 200 Amps rated bus bar connecting with existing wiring circuits by providing copper pin terminals of suitable size complete all as directed of comprising of the following |
| 43 | MCB SPN 63 Amps, 240 Volts - 01 No .( C series) |
| 44 | MCB SP 6-32 Amps, 240 Volts. (C Series) |
| 45 | Supply and fix in repair MCB, DB, SPN 8 way double door with protection type IP-54 with 200 Amps rated bus bar connecting with existing wiring circuits by providing copper pin terminals of suitable size complete all as directed, as approved comprising following :- |
| 46 | MCB SPN 40 Amps 240 Volts-01 No (C Series). |
| 47 | Supply and fix in repair single phase sheet metal powder coated double door distribution board 4 way comprising with following :- (a) MCB SPN 40Amps 240Volts, 10KA - 1 No ('C' Series) (b) MCB SP 6 - 32Amps 240Volts - 2No ('C' Series) |
| 48 | Supply and fix in repairs sheet metal enclosure 2 way without bus bar with MCB comprising following. |
| 49 | Isolator DP 63 Amps Breaking capacity 10 KA. (B series) . |
| 50 | Supply and fix submain wiring in repair with two single core FRLS unsheathed 1100 volts grade cable with stranded copper conductor of size 4 Sqmm in and including PVC casing caping not less than 25mm width, ISI marked including 1 single core cable with stranded copper conductor of size 4 sqmm (green colour) for earthing. Note :- (i) Two runs of 4 Sqmm cable, 1 run of PVC casing & caping and 1 run of 4 Sqmm earth cable shall be measured as 1 RM.(ii) Each submain wiring shall run in seperate PVC casing caping. |
| 51 | Supply and fix submain wiring in repair 2 single core FRLS unsheathed 1100 volts grade cable with stranded copper conductor of size 10 Sqmm in and including PVC casing caping / conduit not less than 25mm dia including 1 single core cable with stranded copper conductor of size 10 sqmm (green colour) for earthing. Note :- (i) Two runs of 10 Sqmm cable, 1 run of PVC casing caping/ conduit and 1 run of 10 Sqmm earth cable shall be measured as 1 RM. (ii) Each submain wiring shall run in seperate PVC casing caping / conduit |
| 52 | Supply and fix in repair 15 Amp plug top with complete accessories all as directed by Engineer-in-chage. |
| 53 | Supply and fixing Recess Mounting LED panel, 2'x2', 34 Watt capacity, white Light, environmentlal friendly, new generation, ashthetically designed ultra modern, fully diffused, white powder coated, with polymer diffuser complete with acessories suitable for Armstrong/Grid Ceiling all as specified and directed . |
| 54 | Supply and fixing Surface Mounting LED panel, 2'x2', 34 Watt capacity, warm white, environmentlal friendly, new generation, ashthetically designed ultra modern, fully diffused, white powder coated, with polymer diffuser complete with acessories suitable for surface all as specified and directed. |
| 55 | Supply and fixing Recess Mounting LED panel, 1'x1', 34 Watt capacity, warm white, environmentlal friendly, new generation, ashthetically designed ultra modern, fully diffused, white powder coated, with polymer diffuser complete with acessories suitable for Armstrong/Grid Ceiling all as specified and directed . |
| 56 | Supply & fix in repair MCB DB, TPN 8 way vertical type, 415 V with 200 Amps rated bus bar and double door connecting with existing wiring circuits by providing copper pin terminals of suitable size complete all as directed, comprising of the following : - (a) MCCB 4 Pole, 415 V fixed type, 160 Amps with breaking capacity 25 KA-01 Nos (incoming) (b) MCB SP 32-63 Amps, 10KA - 24 Nos (C Series) (Outgoing) |
| 57 | Supply & fix in repair PVC cable multistranded insulated copper conductor 1100 volts grade of 4 sqmm 3 core, ISI marked complete all as specified and directed. Make- Polycab/ Havells/ finolex |
| 58 | Supply & Fixing in repair of LED building security light 45 Watt indus series powder coated pressure die cast aluminium high power LED building security light with heat resistant toughened glass with lens with IP66 Protection including 40 mm dia pipe with bracket fixing on wall at any height with MS clamp of suitable size, complete all as specified and directed by the Engineer-in-charge. |
| 59 | Supply and fix in repair aviation light, power efficiency >80%, power factor >0.9, high brightness mono red, short circuit protection on driver, IP-66 protection, die-cast aluminium housing, red polycarbonate diffuser, auto ON-OFF switch integrated, 6–14W, 50 Hz, suitable for high-rise rooftops, complete all as specified and directed by Engineer-in-Charge. |
| 60 | Supply and fix in repair single core FRLS unsheathed 1100 volts grade cable with stranded copper conductor of size 1.5 Sqmm in existing PVC casing caping/ new as per site requirement complete all as specified and directed by Engr in Charge. |
| 61 | Supply and fix in repair single core FRLS unsheathed 1100 volts grade cable with stranded copper conductor of size 2.5 Sqmm in existing PVC casing caping/ new as per site requirement complete all as specified and directed by Engr in Charge. |
| 62 | Supply and fix in repair single core FRLS unsheathed 1100 volts grade cable with stranded copper conductor of size 6 Sqmm in existing PVC casing caping/ new as per site requirement complete all as specified and directed by Engr in Charge. |
| 63 | Supply and fix in repair single core FRLS unsheathed 1100 volts grade cable with stranded copper conductor of size 10 Sqmm in existing PVC casing caping/ new as per site requirement complete all as specified and directed by Engr in Charge. |
| 64 | Suppy and fixing in repair of PVC casing caping with suitable size of screws and making the disturbed surface good complete all as specified and directed by Engineer in charge. |
| 65 | Supply of PVC On wall trunking of size 100x50mm with all finishing accessories (end, joint of lid, joint of body,interior angle, exterior angle, flat angle, derivation) confirming indian standard IS 14927 and BS EN 50085-2-1.Trunking should accept Wiring device with all the functions by associating the accessory of installation. Installation trunking (which carries electrical wiring accessories) should be type 3 (installation)in the new standard.Material should be Non-flame propagating. Degrees of protection provided by enclosure should be IP 40. Protection against mechanical impact should be IK 07. The trunking covers and partitions should be in PVC white colour.Similar to The accessories should be in plastic white colour all as specified and as directed by engr-in-charge. |
| 66 | Material & labour for unscrewing body parts of fans of any make/brands and description and opening of the stator & rotor of following sizes of fans and taking out down rod canopy,shackle, condeser housing with rubber reel bushes,ball bearing,metal bush and carry out repairs as directed and as required as under:-(a) M&L for opening the stator & rotor of the 1200mm / 1400 mm sweep and servicing and reassembling of complete fan by fixing servicable old and new parts of fans i.e. rubber bush of condensor & shackle housing , condensor, gun metal bushes,ball bearings twin twisted copper cable down rod assembly with its shackle condenser housing & canopy ,split pins complete all as per manufacturers design air delivery including greasing,oiling & testing of fans all as per manufacturers design & speed complete all as directed & approved for 1200mm sweep.Notes for item NO (i) to (vii) :- (i). The quoted unit rate shall be deemed to be inclusive of taking out defective parts and fixing of new parts. All new parts shall be measured and paid vide relevant items of the schedule. (ii). The rates for refixing & taking out servicable parts shall be deemed to be included of quoted unit rates.(iii). New parts shall be of respective makes of fans.(iv). The quoted unit rates shall also include writing of MES No of fans(v). Unservicable /defective retrived parts shall be credited vide sch of credit(vi). After assembling all fans shall be tested for the speed as directed.(vii). All the fans are laying in store yard of AGE E/M and shall be repaired at store yard only.(viii) Spares to be paid seperately. |
| 67 | All as per srl item No 59 here-in-before but for wall mounting fans/air circulation fans of any size |
| 68 | All as per srl item No 59 here-in-before but for Exhaust fans of 225/250mm/ 300 mm sweep. |
| 69 | Supply only GI U clamp heavy duty rubber reel of superior quality and nut and bolts with locking arrangement complete all as specified. |
| 70 | Supply only PVC canopy cover superior quality all as specified and directed by Engr - in - Charge |
| 71 | M&L for cleaning the fan motor assembly body,blade of ceiling fan, filling the cavity & painting with existing colour the ceiling fan/Exhaust fan with one coat of superior quality synthetic enamel paint by spraying appratus and spraying process including writing the MES number on the ceiling fans of 1200mm /1400 mm sweep with black colour synthetic enamel paint all as specified and as directed. |
| 72 | All as per srl item No 64 here-in-before but for wall mounting fan / air circulator of any size |
| 73 | All as per srl item No 64 here-in-before but for Exhaust fans of 225/250mm/ 300 mm sweep |
| 74 | Supply only bearing No 6201/6202 for 1200/1400mm sweep ceiling fans. |
| 75 | Supply only capacitor 2.5 MFD dry type. |
| 76 | Supply only gun metal bush suitable for 1200/1400mm sweep ceiling fan. |
| 77 | Supply only replacement of Clamp nut , bolt incliding safety pin for ceiling fan. |
| 78 | Repairs and maintenance of water heaters (Geysers) at existing position of any capacity / size mounted on wall by opening nuts and locating the fault and repair / replacement of the unserviceable spares / parts and make it fully functional and reassembling the same after complete repairs in all respects all as specified and directed. NOTE-: Spare parts will be measured seperately. |
| 79 | Supply only heating element 1KW/1.5KW/2KW/3KW, of storage type/instant type water heater capacity at site complete all as specified and directed. |
| 80 | Supply only repair thermostat / thermal cut out suitable for storage/instant type water heater of capacity upto 50 Ltr complete all as specified and directed. |
| 81 | Supply only hot water extension pipe made out of copper chromium plated 450mm long with brass adaptor and fixing in position complete all as specified. |
| 82 | Supply only 450mm long PVC connector with brass adaptor, washer and fixing in position complete all as specified. |
| 83 | Supply and fix , testing and commissioning of storage type water heater (geyser) vertical type of 6 Ltrs capacity , single phase, vertical type, Rust Resistant, ABS made with thermal cut off with power consumption 3000 watts, ISI marked, BEE 5 star rating including fixing on wall with chroumium plated screws & nut bolts connected to existing water and electric connection complete all as specifed and directed by Engr-in-Charge. |
| 84 | S&F Exhaust fan 250mm sweep, 1240 RPM plastic ABS body without sound with automatic shutter, AC supply, single phase, 230 volts, 50Hz, complete fixing arrangements on the wall with nuts and bolts and making the good surfaces all as specified and directed at site. |
| 85 | S&F Exhaust fan 230mm sweep, 1240 RPM metallic body without sound, AC supply, single phase, 230 volts, 50Hz, complete fixing arrangements on the wall with nuts and bolts and making the good surfaces all as specified and directed at site. |
| 86 | S&F Exhaust fan 300mm sweep, 1300 RPM plastic ABS body without sound with automatic shutter, AC supply, single phase, 230 volts, 50Hz, complete fixing arrangements on the wall with nuts and bolts and making the good surfaces all as specified and directed at site. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 12 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender