Tender For Provision Of Additional Dinning Hall For Jcos Mess Arc, Happy Valley, Shillong Under Ge Shillong
Tender Overview
Project Description
Tender for Provision Of Additional Dinning Hall For Jcos Mess Arc, Happy Valley, Shillong Under Ge Shillong
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 23-Nov-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 30-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | M & L for surface dressing n exc 30 cm deep and averaging 15 CM deep and getting out in soft and loose soil complete all as specified and directed. |
| 2 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil complete all as specified and directed. |
| 3 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm thick complete all as specified and directed. |
| 4 | Removing excavated material n exc 50m and depositng where directed at a level n.exc 1.5m above the starting point complete all as specified and directed. |
| 5 | Material and labour for PCC 1:4:8 Mix, type D-2 (using 40 mm graded crushed stone aggregate) as in foundations, fiiling and mass concrete etc complete all as specified and directed. |
| 6 | M&L for RCC M-25 design mix (Using 20mm graded crushed stone aggregate) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. |
| 7 | M&L for RCC M-25 design mix (Using 20mm graded crushed stone aggregate) as in beam, cantilivers, bressummers, lintels over 1.5m span complete all as specified and directed. |
| 8 | M&L for RCC M-25 design mix (Using 20mm graded crushed stone aggregate) as in Columns, pillars, piers, posts and struts complete all as specified and directed. |
| 9 | M&L for RCC M-25 design mix (Using 20mm graded crushed stone aggregate) as in Slab,Chajja and similar works supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 10 | M&L for TMT bar 10 mm dia and over cut to length, bent to shape reqd, incl cranking, bending, spirally for hooping, hooking ends and binding with 0.90 mm dia MS wire (annealed) complete all as specified and directed. |
| 11 | M&L for TMT bar 8mm dia and over cut to length, bent to shape reqd, incl cranking, bending, spirally for hooping, hooking ends and binding with 0.90 mm dia MS wire (annealed) complete all as specified and directed. |
| 12 | M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, rough finished surfaces of concrete flat complete all as specified and directed. |
| 13 | M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc, rough finished surfaces of concrete flat complete all as specified and directed. |
| 14 | M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings,chajja and similar work; not exceeding 200mm thick (Horizontal or sloping) rough finished surfaces of concrete flat complete all as specified and directed. |
| 15 | M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchions squre, rectangular or polygonal, rough finished surfaces of concrete flat complete all as specified and directed. |
| 16 | M&L hardcore of gauge n exc 63mm diposited, spread and levelled in lagers n exc 15cm thick, watered and rammed to a true surface with broken stone complete all as specified and directed. |
| 17 | M&L for moorum filling in floors laid in lagers n.exc 15cm thick spread levelled and rammed including Watering complete all as specified and directed. |
| 18 | M&L 40 mm thick PCC 1:2:4 type B-1 (20mm graded aggregate) as in flooring cement concrete surface even and smooth without using extra cement complete all as specified and directed. |
| 19 | M& L for Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in CM 1:4 complete all as specified and directed. |
| 20 | M&L for 75 mm thick cement concrete as in plinth protection using cement concrete 1:3:6 Mix, Type C2 (using 40mm graded crushed stone aggregate) finishing concrete surface even and smooth without using extra cement complete all as specified and directed. |
| 21 | M&L for Forming Construction joint 30mm deep x 10mm wide filled with sealing compound Grade 'A' complete all as specified and directed. |
| 22 | M&L for PCC(1:3:6), type C-2, using 40 mm graded crushed stone aggregate as in surface channel and drains including nasessary form work complete all as specified and directed. |
| 23 | M&L Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement including forms, mould, mitred stop ends etc complete all as specified and directed. |
| 24 | M/L precast cement concrete block masonry with solid blocks, using cement concrete 1:3:6 Mix, type C1 (Using 20 mm graded crushed stone aggregate) exc 10 cm in width and settings in CM 1:6 complete all as specified and directed. |
| 25 | M&L for rendering 10 mm thick on concrete surface in cement mortar (1:6) as backing coat and 5 mm th in CM 1:4 using finishing the surface even and smooth without using extra cement and top layer shall be mix with water proofing compound as per manufacturer's instructions complete all as specified and directed.Note:- WPC shall be measured & Paid separately under respec tive item of BOQ. |
| 26 | M&L for 10 mm thick plaster in cm (1:6) on fair faces of brick or concrete surfaces including finishing even & smooth without using extra cement complete all as specified and directed. |
| 27 | M&L for 5 mm thick plaster in CM (1:3) on fair faces of brick or concrete surfaces in ceiling including finishing even & smooth without using extra cement complete all as specified and directed. |
| 28 | Supply only integral water proofing compound (Powder) complete all as specified and directed . |
| 29 | M&L preparation of newely plastered surfaces of wall and applying two coats of distemper oil emulsion on walls over a coat of primer including application of minimum 1.50 mm thick wall care putty on wall over plastered surfaces to prepare the surface even and smooth complete all as specified and directed. |
| 30 | M&L preparation of newely plastered surfaces of ceiling and applying two coats of distemper oil emulsion over a coat of primer including application of minimum 1.50 mm thick wall care putty over plastered surfaces to prepare the surface even and smooth complete all as specified and directed. |
| 31 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint and plaster of paris putty of min. 1 mm thickness over plastered surface to prepare the surface even and smooth havingVOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. |
| 32 | S&F Anodised aluminium for Powder Coating (minimum thickness of powder coating 50 micron) frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed. |
| 33 | S&F Anodised aluminium powder coating of any colour (Thickness or powder coating not less than 50 micron) window shutters, fixed/ Sliding type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and directed. |
| 34 | S&F of Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete all as specified and directed. |
| 35 | S&F 4.8 mm thick sheet glass obscured or frosted on one side good quality area exceeding 0.5 sqm in each pane complete all as specified and directed. |
| 36 | S&F Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 37 | S&F Roller blinds for window including all bracket, chain, cassette system,bottom bar, end caps etc. all necessary fittings to work properly complete all as specified and directed. |
| 38 | S & F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strenngth of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling of plain/corrugated steel sheeting any gauge, thickness in roof covering complete all as specified and directed. |
| 39 | S & F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strenngth of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling of plain/corrugated steel sheeting any gauge, thickness in roof covering complete all as specified and directed. |
| 40 | M&L for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed. |
| 41 | M & L for rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 42 | M&L Preparation of new steel and iron surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed. |
| 43 | Demolition of PCC block masonry and removal of debries from out side of MOD land complete all as specified and directed. |
| 44 | S&F Mild steel screw bolts Dia of neck in 16 to 20mm (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, but length of bolt exc 15cm and n exc 22.5cm long Complete all as specified and directed. |
| 45 | S&F Plate girder or single stanchions, built up of one beam or channel section with flange plates, caps, bases. splices, angle brackets, cleats and other connections conforming to Fe 410 -W (Gde- E- 250) quality-A, complete all as specified and directed. |
| 46 | ML for Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre. Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long, 12 mm thick Seamless calcium silicate ceiling made out of 1800 x 1200 mm size board of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25 mm long self drilling and tapping screws having phillips head with under head cutter at 200 mm centre to centre, including finshing the joint of face board with specially formulated jointing compound and 48 mm wide fibre tape to provide seam less finish complete all as specifiedas in ceiling complete all as specified and directed. |
| 47 | S&F 1.00 mm thick Plain, black, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) Complete all as specified and directed. |
| 48 | S&F PVC (SWR) pipes 110 mm dia single socketed in any length with rubber ring joints fixed to walls/ floor complete including clamps for securing pipe complete all as specified and directed. |
| 49 | S&F PVC (SWR) bend with access door of any radius 110mm bore complete all as specified and directed. |
| 50 | M & for 18 mm to 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including 15 mm thick screed bed or bedding layer in cement mortar 1:4 for laying floor finishes finished fair and even complete all as specified and as directed. |
| 51 | M&L for rounding to edges of stone slabs one edge, such as in steps cooking plateform, and other similar situation complete all as specified and directed. |
| 52 | S&F WPC Fluted Panelling on wall including all necessary Fitting with base of panelling Complete all as specified and directed. |
| 53 | S&F 10mm thick Toughned glass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes,Clips and necessary fitting required complete all as specified and directed. |
| 54 | Material and labour for Point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, including 20 mm dia concealed on wall/ceiling and incuding provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box/metal flush box with suitable steel terminal boxes made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including provision of new plastic laminated sheet top cover upto 12 module for housing the switches , socket outlets, fan regulators etc. with brass screws and brass washers and making good the disturbed surfaces as per existing for one light point controlled by one switch complete all as specified and directed. |
| 55 | Description all as per Srl item No.54 here in before but with 1.5 Sqmm cable for socket outlet point 5 Amp on Independent board complete all as specified and directed. |
| 56 | Description all as per serial item No 54 above but with 4 sqmm cable for 3 pin 15 Amps switch socket outlet (Power point) complete all as specified and directed. |
| 57 | S & F Modular switch 1 way 6A, 1 module complete all as specified and directed. |
| 58 | S & F Switch socket Combination 16A, 6 pin, 3 module complete all as specified and directed. |
| 59 | S & F Switch socket outlet 3 pin 6 amp' moduler type complete all as specified and directed. |
| 60 | Supply and fixing round shape 24 watt warm colour, 220 volts AC recessed/surface type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders,LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 61 | Supply and fix 18 W LED light fitting wall mounted batten 4'ft , PVC housing, enivromental friendly, heat sink provided for efficent heat dissipation and integrated electronic driver for 20 watt,warm/white including necessary connection complete all as specified and directed. |
| 62 | Supply and fixing in repair LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V ,warm/white AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 63 | Supply and fix exhaust fan, plastic body AC single Phase. 230V of size 250mm sweep with, blades, and frame and louvers complete all as specified and directed. |
| 64 | Supply & fix ceiling rose surface bakelite 65 mm x 50 mm two to three terminal suitable for 230 Volts AC 6 Amps complete all as specified and directed. |
| 65 | Supply and fix in repair MCB Distribution board , 240 volts single pole and neutral ,double door, sheet steel, enclosure powder coated with 100 Amps rated busbar with neutral link, 12 ways , fixed on wall duly grouted in solid block wall or on wooden board with electrical connection, complete all as specified and directed. |
| 66 | Supply and fix MCB SPN, 240 Volts, 40 Amps, 10 kA rupturing capacity 'C' series complete all as specified and directed . |
| 67 | Supply and fix in repairs MCB, single pole 240 volts 6 to 32 Amps capacity fixed in DB's complete all as specified and directed. |
| 68 | M & L Sub main wiring with two run single core 6 Sqmm FRLSH copper conductor cable PVC insulated, unsheathed, 1100 V including 20 mm dia concealed on wall/ceiling in ISI marked with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of 6 Sqmm single core PVC FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion inculding taking down old wiring etc complete all as specified and directed.Note: (i) Two runs of 6 sqmm and one run of 6 sqmm cable and one run of PVC conduit shall be measured as one RM. |
| 69 | Note for all items: If in BOQ, any item found repeated and contractor quotes different rates for the same, the lesser rate quoted by the contractor shall be admissible for payment and no claim of contractor, whatsoever, on this account shall be entertained by the Department. NOTE FOR ALL ITEMSIn case in BOQ any item found repeated and contractor quotes different rate for the same, the rate quoted on lesser side shall only be applicable for payment and no claim whatsoever on this account shall be entertained by the Department. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
TodayBid Submission Deadline
Online submission via eProcurement portal.
TodayBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 1 dayTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender