Tender For Addition/Alteration To Toilet, Bldg No P 782, Provn Of Toilet And Interlocking Tiles And Parking Shed Under Age B/R I At Chandimandir
Tender Value
45.98 Lakhs
Estimated cost
Bid Submission
23 Nov 2026
19 days left
EMD
91960
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Panchkula → Haryana
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Addition/Alteration To Toilet, Bldg No P 782, Provn Of Toilet And Interlocking Tiles And Parking Shed Under Age B/R I At Chandimandir
BOQ
| Sl. No. | Item Description |
| 1 | Taking down chowkats or frame not exc. 1.5 sqm with shutters (without taking off shutters from the frame) removal from site complete all as specified and directed. |
| 2 | Taking down chowkats or frame exc. 1.5 sqm and n exc 4 Sqm with shutters (without taking off shutters from the frame) complete all as specified and directed. |
| 3 | Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge, including making good dismantled portion with PCC (1:2:4) type B-1 in CM 1:3 complete all as specified and directed. |
| 4 | Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge.NOTE : Glass will be mesured and paid sepreately |
| 5 | 4.80mm thick ordinary quality tinted glass, fixed to aluminum frame work in panels n. exc 0.5 Sqm in each pane, complete all as specified & directed. |
| 6 | 4.00mm thick ordinary quality tinted glass, fixed to aluminum frame work in panels n. exc 0.5 Sqm in each pane, complete all as specified & directed. |
| 7 | Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples , complete all as specified and directed. |
| 8 | D' type, 150mm Extruded aluminium alloy handle fabricated type, complete all as specified and directed. |
| 9 | 150mm aluminium alloy barrel tower bolts of extruded section, complete all as specified and directed. |
| 10 | ACP sheet of 4mm thick, coloured, incl powder coated aluminium beading with EPDM packing, stainless steel screw etc. complete all as specified and directed |
| 11 | Mild steel two levers Mortice lock, vertical type, size 75mm complete all as specified and directed. |
| 12 | Door closer hydraulically regulated of aluminium extruded section, designation No. 3, universal type, suitable for door shutters of 851 to 1000mm in width and of weight between 61 to 80 kg, complete all as specified and directed. |
| 13 | Floor door stopper of aluminum alloy body and tongue, anodized with hard drawn steel spring, fixed in floor (140mm size), complete all as specified and directed. |
| 14 | Cast iron body Door closer hydraulically regulated, designation No. 2, universal type, Suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 kg and fixed , complete all as specified and directed. |
| 15 | Taking down existing plaster of any description on brick wall/ concrete surface including racking out joints, hacking for key, scrubbing down with water etc complete, all as specified and directed. |
| 16 | Rendering 15mm thick in Cement and Sand mortar 1:4 over fair faces of brick / concrete ,finished even and smooth without using extra cement, including using water proofing compound, including necessary scaffolding & safety arrangement for plaster upto & including 4 storey building complete all as specified and directed. Note : WPC shall be measured and paid separately. |
| 17 | Rendering 15mm thick in Cement and Sand mortar 1:4 over fair faces of brick / concrete ,finished even and smooth without using extra cement, including necessary scaffolding & safety arrangement for plaster upto & including 4 storey building complete all as specified and directed. |
| 18 | Supply only Liquid water proofing compound complete all as specified and as directed by engineer-in-charge. |
| 19 | Rendering 15mm thick in Cement and Sand mortar 1:6 over brick or concrete surfaces finished even and smooth without using extra cement complete, all as specified and directed. |
| 20 | 10mm thick rendering on fair faces of brick work or concrete surfaces in cement mortar 1:6, complete all as specified and directed. |
| 21 | Rendering 5mm thick on fair faces of concrete surfaces in ceilings in CM 1:3, surface finished even and smooth without using extra cement complete all as specified and directed. |
| 22 | Dubbing out average 20mm thick on irregular faces/repair of damage area of walls, chajja and other similar work, exposed reinforced surfaces, upto 15m height in Cement and Sand mortar 1:4 complete all as specified and directed |
| 23 | Applying Wall care putty (average thickness 1-2mm as required for desired smoothness and leveling of surfaces in two or more layers) and sand papering for making the surfaces even and smooth complete all as specified and directed. |
| 24 | Preparation of newly plastered wall surfaces and applying two coats of oil bound over a coat of chalk whiting complete all as specified and directed. |
| 25 | Preparation of old plastered wall surfaces and applying two coats of oil bound over a coat of chalk whiting complete all as specified and directed. |
| 26 | Old plastered surfaces of internal wall and applying two coats of oil bound distemper over 1 mm thick wall care putty on wall plastered surface complete all as specified and as directed. |
| 27 | Preparation of newly plastered surfaces of ceiling by washing, rubbing down and stopping of painted surfaces, and applying two coats of distemper oil emulsion over 1mm thick wall care putty, on plastered surfaces, prepara-tory to distempering complete all as specified and directed. |
| 28 | Preparation of new surfacs and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces, complete all as specified and directed. |
| 29 | Preparation of old surfacs and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surfaces, complete all as specified and directed. |
| 30 | Complete removal of existing treatment by scrapping of walls, chajjas, ceilings, fins, fascia etc. using mechanical means like mechanical sander etc. with internal dust extraction system including expose sound substrata for further surface preparation prior to painting work all as specified and directed. |
| 31 | Applying a layer of acrylic crack filler paste or similar material wich can fill upto 5 mm cracks after widening cracks in V Groove by using scrapper blade or angle cutter complete all as directed. |
| 32 | Providing and applying waterproof wall putty (cement-based or polymer-modified as approved) in two or more coats over prepared plastered surface to achieve smooth, even finish surface suitable as required for uniform application and curing as per manufacturer's instruction and as directed by engineer-in-charge |
| 33 | Applying with 1 or 2 coats of acrylic waterproofing primer coating which is formulated with acrylic polymers having crack bridging ability of upto 1mm, tensile strength of 1.8 mpa, 100% elongation and can withstand upto 5 bars hydrostatic pressure to provide better mechanical strength and adhesion to the surface all as per manufacturer's instruction. Priming work to be carried out post all repair and preparatory work including cleaning the surface from loose particles, dust and other foreign materials using water by pressure washer all as directed by engineer-in-charge |
| 34 | Applying 2 coats of modified acrylic exterior emulsion over old and new surface having excellent scrub and peel resistance, superior whiteness, excellent finish, resistance to fading of colours, advanced anti fungal and algal protection against all round weather and paint performance of Min. 5 years so as to obtain as acceptable finish all as per manufacturer's instruction and directed by engineer-in-charge |
| 35 | Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 15 cm thickness. (Below or above ground level) complete all as specified and directed. |
| 36 | providing cement concrete type D2, 1:4:8 using 40 mm graded stone aggregate, as in foundation, mass concrete etc., complete all as specified and as directed |
| 37 | 75mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base, complete all as specified and directed. |
| 38 | 100mm thick plain cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregate as in sub base complete all as specified & directed. |
| 39 | Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviveable tiles to store and rubbish off the premises complete all as specified and directed |
| 40 | Glazed coloured ceramic tiles in vertical surface 300mm x 450mm x 7mm thick , set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over and including 10mm thick rendering in cement mortar 1:4 complete all as specified and directed. |
| 41 | Glazed ceramic coloured tiles 7mm thick in vertical surface like skirting, dado of area exc 0.16 sqm but not exc 0.72 sqm complete, set and joint in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick rendering in cement mortar 1:4, complete all as specified and directed. |
| 42 | Non skid, first quality ceramic coloured tiles, 7 to 8 mm thick (square/ rectangular) area or each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over and including 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed. |
| 43 | Non skid ceramic coloured tiles 7 to 8 mm thick (square /rectangular) area of each tile exc 0.18 sqm but not exceeding 0.38 sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match over and including 15 mm thick bedding layer in CM 1:6, complete all as specified and directed. |
| 44 | Coloured vitrified ceramic tiles, 8-9mm thick (square / rectangular) , area of each tiles n.exc 0.36 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over and including 15mm thick screed bed in cement mortar 1:6, complete all as specified and directed. |
| 45 | All as per serial item No 44 herein before but on vertical surfaces as in skirting over and including 10mm thick rendering in cement mortar 1:4 complete all as specifed and directed. |
| 46 | Vitrified coloured double / ultra charge tiles 10mm thick (square/rectangular) polished, area of each tile exceeding 0.42 sqm but not exceeding 1.00 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over and including 15 mm thick cement mortar (1:6) screed bed for floor finishes complete all as specified. |
| 47 | All as per serial item No 46 herein before but on vertical surfaces as in skirting over and including 10mm thick rendering in cement mortar 1:4 complete all as specifed and directed. |
| 48 | 18-20mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite 15mm thick screed in cement mortar 1:6 complete all as specified and directed. |
| 49 | Providing edge moulding to 18-20 mm thick stone of counters vanities steps, cooking platform etc, including machine polishing to edge to give high gloss finish etc. complete all as specified and directed. |
| 50 | Preparation of wall or similar surface by removing all loose material, clean by wire brush and water, applying two coats of dampproof component, sure seal (Dr Fixit) or equivalent as per manufacturer instruction. Applying the component by brush 1.10kg/sqm for each coat, second coat in perpendicualr direction to first coat and after 4-6 hour dry of first coat, complete all as specified and directed.Note: Dampproof coating shall be done by authorised applicator |
| 51 | 12mm thick toughned glass as in hinged doors, partitions alongwith slidable doors and similar work including cutting to shape, drilling holeswith necessary screws/ beading, rubber packing, L Patch bottom and top, self closing patch top pivot etc complete all as specified and directed. |
| 52 | Stainless steel lock for 10-12mm glass door, having knob inside wuth three keys, satin finish, complete all as specified and directed. |
| 53 | 300 mm long stainless steel handle, fancy type, fixed to toughened glass complete all as specified and directed. |
| 54 | Wash hand basin, vitreous china, flat back, white of size 550 x 400 mm with CP waste coupling, angle brackets, PVC waste pipe, fixed as in repair complete all as specified and directed. |
| 55 | 15mm bore pillar tap, fancy type, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nuts, fancy type as in repair complete all as specified and directed. |
| 56 | EWC single piece chinaware With and including sheet cover, PVC pipe, flushing arrangement complete all as specified and directed by engr-in-charge. MAKE CERA Model No S1013208 S-220 or equivalent as approved by GE |
| 57 | Two way Bib tap brass, fancy type, (incl fixing arrangement of health faucet) long body with wall flange, standard chromium plated, cast copper alloy, screwed down for iron pipe or for brass ferrule, suitable for 15mm bore pipe, fixed as in repairs complete all as specified and directed. |
| 58 | Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect, fixed as in repair complete all as specified and directed. |
| 59 | Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect, complete all as specified and directed. MAKE : JAQUAR, KOHLER, CERA. |
| 60 | Toilet paper holder, vitreous china fixed in position, with CP screws , complete all as specified and directed. |
| 61 | Vitreous China Urinal, Half stall type, fixed against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement including CP waste Coupling, 32mm PVC waste pipe, fixed as in repair Complete all as specified and directed. Make Jaquar- URS-WHT-13261H and equivalent in kholer and cera |
| 62 | Vitreous China Urinal, Half stall type, fixed against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement including CP waste Coupling, 32mm PVC waste pipe, Complete all as specified and directed. Make Jaquar- URS-WHT-13261H and equivalent in kholer and cera |
| 63 | PVC connections 15 mm size with PTMT nuts of length 600 mm , complete all as specified and directed. |
| 64 | Towel rail 20mm dia, D type , 600mm long of CP fixed with and including chromium plated brass screws and wooden / plastic cleats (minimum weight 190gms), fixed as in repair complete all as specified and directed. |
| 65 | Towel ring CP fixed with and including chromium plated brass screws and wooden / plastic cleats (minimum weight 90gms), complete all as specified and directed. |
| 66 | Bevelled edge looking mirror, 5.5mm thick of selected quality glass, including wood finish PVC moulding mounted on 6mm thick ply or of PVC frame fixed to wall with screw and rawl plugs, fixed as in repairs complete all as specified and directed. |
| 67 | CP Toilet paper holder with shelf having nickle plating minimum 10.0 micron and, chromium plated minimum 0.3 micron, complete all as specified and directed. MAKE : JAQUAR, KOHLER AND CERA. |
| 68 | CP Towel ring square with round flange having outer length of 210mm having Nickle plating minimum 10.0 micron and chromium plating minimum 0.3 micron complete all as specified and directed. MAKE : JAQUAR, KOHLER AND CERA. |
| 69 | CP Soap dish having Nickle plating minimum 10.0 micron and, chromium plated minimum 0.3 micron, complete all as specified and directed. MAKE : JAQUAR, KOHLER AND CERA. |
| 70 | Stainless steel towel rack 600mm long with lower hanger having Nickle plating minimum 10.0 micron and, chromium plated minimum 0.3 micron, complete all as specified and directed. MAKE : JAQUAR, KOHLER AND CERA. |
| 71 | 15mm angle valve with wall flange having water flow of 42.44 LPM@ 3 Bar having water tightness of min 16 Bar and pressure resistance of min 25 bar, Nickle plating minimum 10.0 micron and chromium plating minimum 0.3 micron, complete all as specified and directed. Make : Jaguar, kholer and cera. |
| 72 | 15mm Two way bib tap with wall flange having water flow of 42.44 LPM@ 3 Bar having water tightness of min 16 Bar and pressure resistance of min 25 bar, Nickle plating minimum 10.0 micron and chromium plating minimum 0.3 micron, complete all as specified and directed. MAKE : JAQUAR, KOHLER AND CERA. |
| 73 | Table top wash hand basin and single lever Basin Mixer with popup waste & 375mm long Braided Hoses with withstand pressure of minimum 10 bar, having flow rate of 13.48LPM @ 3 bar, water tightness min 16 Bar & pressure resistance min 25 Bar having Nickle plating minimum 0.3 micrin, complete all as specified and directed. MAKE : JAQUAR, KOHLER AND CERA. |
| 74 | Corner glass shelf (with bracket) having radius of min 225mm and glass thickness of min 6mm Nickle plating minimum 10.0 micron and chromium plating minimum 0.3 micron, complete all as specified and directed. MAKE : JAQUAR, KOHLER AND CERA. |
| 75 | Glass shelf 600mm long having glass thickness min 6mm, Nickle plating minimum 10.0 micron and chromium plating minimum 0.3 micron, complete all as specified and directed. MAKE : JAQUAR, KOHLER AND CERA. |
| 76 | Robust stylish wall mounted liquid soap dispenser 1L (Black, Pack of 1) - with Adhesive Hooks complete all as specified and directed. |
| 77 | Supply and fixing of Automatic Hand dryer stainless steel wall mounted commercial dryer, Fast-Dry Energy-Efficient and Rust-Proof for Hotels and Corporate Washrooms complete all as directed. |
| 78 | Supply and fixing Paper Towel dispenser wall mount ABS for C and M-Fold towels of 300-450 capacity complete all as specified and directed. |
| 79 | Taking up or down steel tubing and connections 20mm bore ,complete all as specified and directed. |
| 80 | Taking up or down steel tubing and connections 15mm bore, complete all as specified and directed. |
| 81 | 20 mm (outer dia) CPVC pipes, SDR 11 and Plain CPVC SDR 11 fittings, fixed on walls/ceiling or laying in floors, complete all as specified and directed. |
| 82 | 25 mm (outer dia) CPVC pipes, SDR 11 and Plain CPVC SDR 11 fittings, fixed on walls/ceiling or laying in floors, complete all as specified and directed. |
| 83 | 20mm Galvanised steel tubes, medium grade, incl all fitting, TEE, elbow fittings fixed complete to walls, ceiling complete all as specified and directed and directed by Engr-in-charge |
| 84 | Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings etc and cutting chases for concealed water tubing & making good, cutting not exc 10 cm girth, in brick walls complete all as specified and directed. |
| 85 | Brass elbow 25mm outer dia for CPVC pipe complete all as specified and directed. |
| 86 | Brass elbow 20mm outer dia for CPVC pipe complete all as specified and directed. |
| 87 | Brass Tee 20mm outer dia for UPVC pipe complete all as specified and directed. |
| 88 | Male Brass Threaded Adaptor 20mm outer dia (MTA/ FTA) ) for CPVC pipe complete all as specified and directed. |
| 89 | Female Brass Threaded Adaptor (FTA/ MTA) 20mm outer dia for CPVC pipe complete all as specified and directed. |
| 90 | Bib taps brass, fancy type, long body with wall flange, chromium plated, cast copper alloy, screwed down for iron pipe or for brass ferrule, suitable for 15mm bore pipe, fixed in repair complete all as specified and directed. |
| 91 | Angular stop cock, fancy type, cast copper alloy chromium plated, screwed down, screwed both and for iron pipe or for union, suitable for 15mm bore pipe, fixed as in repair complete all as specified and directed. |
| 92 | Glass self 600mm long having glass thickness min 6mm, Nickle plating minimum 10.0 micron and chromium plating minimum 0.3 micron completed all as specified and directed. |
| 93 | 1000 litres capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) double layered hoisted and fixed in position, including tank nipple, float valve of PTMT 20mm bore etc, complete all as specified. |
| 94 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., complete all as specified and directed. |
| 95 | PVC (SWR) pipes, single socketed, of pressure rating 6 kgf/cm2 in any length with rubber ring joints, laid in trenches, floor etc, 110 mm bore, in any length, including cutting/ boring of brick/ concrete wall/ slab wherever required and making good of the surface complete all as specified and as directed by engineer-in-charge. Note:-(i) Smoke test shall be carried out to check the leakage at joints.(ii) Joint of pipe with RCC slab (in case of floor trap/ ‘P’ trap shall be water sealed with crack repair component of Dr fixit of equivalent. Cost of the same shall deemed to be included in the rate quoted against this item. |
| 96 | PVC (SWR) rain water pipe, 110mm bore, single socketed in any length of pressure rating 6 kgf/cm2 with rubber ring joints, fixed to walls with MS/GI clamps made out of flat iron of size 25mm x 3mm including nuts bolts etc, complete all as specified and directed. (i) Joint of pipe with RCC slab (in case of floor trap /'P' trap shall be water sealed with crack repair component of Dr Fixit or equivalent |
| 97 | PVC (SWR) bends of any radius, pressure rating 6 kgf/cm2, for 110 mm bore pipe complete all as specified and as directed. |
| 98 | PVC (SWR) junction (Single T) equal or unequal with access door for 110 mm bore pipe,of pressure rating 6 kgf/cm2 complete all as specified and directed. |
| 99 | PVC (SWR) pipes, single socketed, of pressure rating 6 kgf/cm2 in any length with rubber ring joints, laid in trenches, floor etc, 75 mm bore, in any length, including cutting/ boring of brick/ concrete wall/ slab wherever required and making good of the surface including excavation and RFR complete all as specified and as directed by engineer-in-charge. Note:-(i) Smoke test shall be carried out to check the leakage at joints.(ii) Joint of pipe with RCC slab (in case of floor trap/ ‘P’ trap shall be water sealed with crack repair component of Dr fixit of equivalent. Cost of the shame shall deemed to be included in the rate quoted against this item |
| 100 | PVC (SWR) bends of any radius, pressure rating 6 kgf/cm2, for 75 mm bore pipe complete all as specified and as directed. |
| 101 | PVC (SWR) junction (Single T) equal or unequal with access door for 75 mm bore pipe,of pressure rating 6 kgf/cm2 complete all as specified and directed. |
| 102 | PVC (SWR) 150mm bore, single socketed in any length with rubber ring joints fixed to wall of pressure rating 6 kgf/cm2, fixed to walls with MS/GI clamps etc, complete all as specified and directed. (i) Joint of pipe with RCC slab (in case of floor trap /'P' trap shall be water sealed with crack repair component of Dr Fixit or equivalent |
| 103 | PVC (SWR) pipes single socketed in any length with rubber ring joints of pressure rating 6kgf/cm2 fixed complete to laid in trenches, floor etc, 150mm bore single socketed in any length of pressure rating 6kgf/cm2, complete all as specified and directed.Note:(i) Joint of pipe with RCC slab (in case of floor trap/ ‘P’ trap shall be water sealed with crack repair compounent of Dr fixit or equilent. |
| 104 | 150 mm bore PVC (SWR) of pressure rating 6kgf/cm2 ) bends of any radius complete all as specified and directed. |
| 105 | 150 mm bore PVC (SWR) of pressure rating 6kgf/cm2 ) bends with access door of any radius complete all as specified and directed. |
| 106 | PVC (SWR) pipes single socketed in any length with rubber ring joints of pressure rating 6kgf/cm2 fixed complete to laid in trenches, floor etc, 200mm bore single socketed in any length of pressure rating 6 kgf/cm2, complete all as specified and directed. |
| 107 | PVC (SWR) of pressure rating 6 kgf/cm2 Junction (Single T) equal or unequal for 200mm bore pope, fixed as in repair complete all as specified and directed. |
| 108 | PVC (SWR) of pressure rating 6 kgf/cm2) bends of radius 200mm bore complete all as specified and directed |
| 109 | PVC (SWR) nahani traps/ floor trap, plain with grating including jointing with solvent cement 75mm bore, including jointing to waste pipe set in cement concrete type B-1(1:2:4) , fixed as in repair complete all as specified. |
| 110 | PVC (SWR) nahani traps/ floor trap, plain with grating including jointing with solvent cement 75mm bore, including jointing to waste pipe set in cement concrete type B-1(1:2:4) , complete all as specified. |
| 111 | PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement, fixed as in repair complet all as specified and dircted. |
| 112 | PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement, complet all as specified and dircted. |
| 113 | PVC cowls of 110mm dia, complete all as specified and directed by Engr-in-Charge |
| 114 | Cement concrete type B-0, 1:2:4 using (12.5 mm graded crushed stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, parapets and railings upto 60 cm in height, copings, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including the use of forms or moulds with plain faces complete all as specified and directed. (Cement concrete item shall be reinforced, where ordered. Reinforcement shall be measured and paid separately). |
| 115 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and n exc 1.5m in depth and getting out in soft and loose soil all as specified & directed by Engineer-in-Charge. |
| 116 | Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm depth , complete all as specified and directed. |
| 117 | Removal of excavated material to distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point , complete all as specified and directed. |
| 118 | Hardcore of broken gauge exc 63 mm but n exc. 100mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and rolled/rammed to a true surface using broken stone or boulders, complete allas specified. |
| 119 | Earth filling under floor including watering and consolidation complete (Earth shall be obtained from excavation free for vegetation, pebbles, foreigh materials etc) complete all as specified & directed. |
| 120 | 150mm dia Plain cement concrete, type C-2, 1:3:6, using 40mm graded crushed stone aggregate as in bed to drain pipe including packing under pipes, haunching and tested after the pipe are laid, complete all as specified and directed. |
| 121 | HDPE double wall corrugated (DWC) pipes (ISI Marked) 150mm SN-8 class as per IS 16098 Part -II for non pressure underground drainage and sewage applications with specials including cost of special O rubber rings couplers etc, laid in trenches on concrete bed to level / gradient, jointing with appropriate class fittings as per manufacturer's instructios including jointing accessories and fittings complete all as specified and directed. |
| 122 | Reinforced concrete pipes, 150 mm bore class NP2, laid in trench and jointed complete with collars , jointed with cement mortar inculding fitting of same grade complete all as specified and directed. |
| 123 | Plain cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete complete all as specified & directed. |
| 124 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including dismantling all quoins, arches, pillars etc but excluding ashlar facings, dress stonework and precast concrete articles, complete all as specified and directed. |
| 125 | Brick work with sub class ‘B’ bricks old size bricks, straight or curved on plan exc 6 metre mean radius built in cement mortar 1:6 complete all as specified & directed. |
| 126 | Brick work with sub class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls, for partition walls, parapet in balcony and other similar work built in cement mortar 1:4 complete all as specified & directed. |
| 127 | PCC (1:2:4) type B-0 using 12.5 mm graded stone aggregate as in surface channels, benching and drains complete all as specified and directed. |
| 128 | Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or ¾ section) in plain cement concrete 1:2:4 type B1 smooth finished, and reforming benching as required, internal dia of pipe 150mm all as specified and directed. |
| 129 | Precast reinforced cement concrete (1:2:4) type B1 using 20mm graded stone aggregate as in cover slabs (for manholes) inclusive of form work & re-inforcement set in cement mortar 1:4 complete all as specified and as directed. |
| 130 | Pre cast factory made RCC manholes and drain covers/slab of size 600mmx1200mmx100mm thick for normal duty, using 20mm graded crushed stone aggregate type B-1 (1:2:4) including RCC ring/frame, with reinforcement set in cement mortar and MS frame as in man hole covers set in cement mortar 1:4 complete all as specified and directed. |
| 131 | Treating of soil under existing floors using emulsion @ one liter per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors, complete all as specified and directed. |
| 132 | Providing and injecting chemical emulsion for Post Constructional Antitermite treatment along external wall below concrete or masonry apron using chemical emulsion @ 2.25 liters per linear meter including drilling and plugging hole etc. in apron |
| 133 | 25mm dia stainless steel curtain rod including fixing fancy types brackets, stops, rollers etc, as in repairs complete all as specified and directed |
| 134 | PVC lining coloured or selective pattern, PVC lining of hollow profile not less than 5mm thick and not less than 250mm wide intelocking type system as in wall/celing linings including end and intermediet U or L PVC sections as per manufacturer instructions including dismantling existing paneling, complete all as specified and directed(Note : Colour/design and pattern shall be as decided by the GE) |
| 135 | Designer wall paper of 210-300 GSM, washable High strength, breathable fixed to wall/ column surface complete all as specified and directed. (Note: Colour/design and pattern shall be as decided by the GE) |
| 136 | Providing and fixing false ceiling at all heights with GRG (Glass Fibre with Semi with fully Reinforced gypsum) false ceiling tiles of size 595x595mm of approved texture, design and patterns having moisture content less than 2% humidity resistance of 99% NRC 0.50 to 0.75 as per IS 8225:1987, Non-combustible as per BS 476 (part 4) - 1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33 mm thick (galvanised @ 120 grams per sqm including both sides) comprising of main T runners of size 15x32 mm of length 1200mm and secondary module of size 600x600mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) ie., 50mm long 8mm outer dia Meter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L-shape level adjuster of size 85 X 25 x 0.40 mm of length 3000mm to be fixed on periphery wall/patition with the help of plastic rawl plugs at 450mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per direction of Engineer-in-charge. |
| 137 | Steel work in tubular trusses/rafter/purlin including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS.1161- 1979 grade St.-240 t complete all as specified & directed. |
| 138 | Rolled sections as in main and cross beams, columns , hip and jack rafters; purlins where connected to common rafters of angle , pipe sections etc , Fe 410 Gde 250 quality B complete all as specified and as directed |
| 139 | Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed complete all as specified and directed. |
| 140 | Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed complete all as specified and directed. |
| 141 | Two coats of synthetic enamel paint on steel surfaces over one coat of red oxide primer on surfaces over 10 cm width or girth including preparation of new surfaces complete all as specified & directed. |
| 142 | Two coats of synthetic enamel paint on steel and iron surfaces over 10 cm width or girth including preparation of old surfaces complete all as specified & directed. |
| 143 | Framed work such as grills, gratings, etc, with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron door, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work confirming to Fe-290, Gde-E-190 complete all as specified and directed. |
| 144 | Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm complete all as specified and directed. |
| 145 | All as per serial item No 144 above but TMT bars 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders all as specified and directed by Engr-in-charge. |
| 146 | Form Work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundations and plinth beams and similar work, vertical or to batter to give rough finish to flat surfaces complete all as specified and directed. |
| 147 | Form work to rough finished surfaces of sides and soffits of floor/plinth or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc also splays between floors and beams etc complete all as specified and directed by Engr-in-Charge |
| 148 | Form work to sides of pillars, columns and similar items (square, rectangular or polygonal) including edges rough finished surface of concrete flat complete all as specified and directed. |
| 149 | Flat Formwork to rough finished surfaces of concrete to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed. |
| 150 | Form work to edges of concrete flats, treads, break in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n.exc 20cm wide and side of RCC / PCC bends in walls , horizontal or sloping and similar work exc 10cm but n.exc 20cm wide complete all as specified and directed. |
| 151 | Form Work to edges of concrete flats, treads, break in floors, window cills, concrete railings, openings in concrete walls, floor and roofs exc 5cm but n.exc 10cm wide and side of RCC / PCC bends in walls , horizontal or sloping and similar work exc 10cmwide complete all as specified and directed. |
| 152 | Reinforced cement concrete type A-1, 1:1½:3 (nominal mix, using 20mm graded crushed stone aggregate) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed |
| 153 | Reinforced cement concrete type A-1, 1:1½:3 (nominal mix, using 20mm graded crushed stone aggregate) as in beams, cantilevers, bressumers, lintels over 1.5 metre span and the like complete all as specified and directed (reinforcement shall be measured and paid for separately). |
| 154 | Reinforced cement concrete type A-1, 1:1½:3 (nominal mix, using 20mm graded crushed stone aggregate) as in Columns, piers, post and struts complete all as specified and directed. |
| 155 | Reinforced cement concrete type A-1, 1:1½:3 (nominal mix, using 20mm graded crushed stone aggregate) as in chajjas, facias, etc complete all as specified and directed. |
| 156 | Reinforced cement concrete type A-1, 1:1½:3 (nominal mix, using 20mm graded crushed stone aggregate) in slabs supported on walls, beams and columns in floors, roofs, landings balconies, canopies, deck slabs and in shelves and the like etc complete all as specified and directed. |
| 157 | Plain cement mortar 1:3:6 (type C-2 using 20mm graded aggregate), 50mm thick as in Plinth protection , finishing cement concrete even and smooth without using extra cement, making expansion joint & filling with matic asphalt bituminous complete all as specified and directed. |
| 158 | Surface dressing n.exc 15cm deep in hard dense soil complete all as specified and directed |
| 159 | Coloured non skid porcelain tiles, exterior grade 400x400x12mm thick heavy duty (Endura from Johnson or equivalent) as in floor, set and jointed in neat slurry with grey cement with pigment to match the colour of tiles laid over and including 15mm thick screed bed in cement mortar 1:6, including taking out old tile, complete all as specified and directed |
| 160 | Sand filling under floors, inter locking tiles/paver blocks or in foundations including watering and consolidation complete all as specified |
| 161 | Machine pressed Concrete interlocking paver block rubber moulded, prepolished (glazy finish), any shape and size conforming to IS 15658-2006 of 80 mm thickness, M-40 Grade with gray cement and pigment complete all as specified and directed |
| 162 | Roof treatment with water proofing compound complete all as specified and directed. Make: Pidilite/ Fosroc/Asian. Roof treatment with WPC will be divided into following stages as under and will be certified by technical rep of company whether the stages completed are as per manufacturer’s instruction and finally passed by Engr-in-Charge/GE:- |
| 163 | Surface Preparation:All loose and de-bonded concrete/ screed, grass, roots, loose particles, dirt & shall be removed. Roof substrates must be pressure-washed with water with a minimum working pressure of 1,400 psi to be used to and/or remove all dirt, dust, chalking and waste products. Remove algae, mold by using bleach solution or biowash. |
| 164 | Crack Repair:All visible hairline cracks on concrete roof screed more than 0.50 mm and not giving hollow sound, should be cut and widen in V shape with mechanical cutter in the size (8mm W x 6mm D). any filling of cracks with Dr. Fixit PU sealant / Hybrid Sealant with suitable gun and smoothed with a putty knife or trowel. Allow sealant to cure a minimum (72 Hrs.) 3 days. |
| 165 | Screed Repair in pockets as required:Remove loose and damaged concrete roof screed in pockets with mechanical cutter. Clean the concrete screed with high pressure water jet to remove dirt and loose particles. brush apply a bond coat of Dr. Fixit Pidicrete URP mix in the ratio of 1:1 (URP 1: Cement 1) by volume to make it lump free slurry when applied on in the pre wet surface. laying of fall roof screed in correct slope and gradient. Mix Dr. Fixit Pidicrete URP 10% by weight of cement in (M20) concrete in ratio of 1:1.5:3 i.e., one bag of 50kg cements: 1.5 times volume of sand: 3 times volume of aggregates: 25L water per cum of concrete. Level the repair mortar and finish with trowel. Moist cureof screed should be done for 7days. followed by Air curing screed for 4-5 days, before application of roof treatment. |
| 166 | Rainwater outlets treatment: Hacking and chipping the surface around the rainwater drain outlet up to25mm in depth. Apply bond coat of Dr. Fixit Pidicrete URP in the ratio of 1:1 (URP 1: Cement 1) by volume over the corners and pipe insert outlet gaps. Filling the gaps around drain mouth with (PMM) polymer modified mortar mixed with Dr. Fixit Pidicrete URP 10% by weight of cement in the ratio of 1:3. Providing & fixing 100 mm width 225-gsm g/m2 Fiberglass Chopped Strand Mat around the periphery of drain mouth of rainwater outlet sandwiched with Dr. Fixit Wonderproof 100. Apply two thick coats of Dr. Fixit Wonderproof 100 waterproofing coating to completely cover the mesh/fabric and surrounding area. |
| 167 | Vertical upstand:Providing 100mm x 100 mm Square / rectangle upstand of M20 grade concrete or with PMM around mechanical equipment like HVAC support air-conditioning unit solar panels. Etc. Applying two thick coats of Dr. Fixit Wonderproof 100 over the entire upstand, embedding it 225-gsm g/m2 Fiberglass Chopped Strand Mat while the Dr. Fixit Wonderproof 100 is still wet. Apply Dr. Fixit PU sealant / Feviseal Hybrid Sealant around the junction of fabricated stand inserted and wall mounting mechanical fixtures. |
| 168 | Waterproofing Application:Premix Dr. Fixit Wonderproof 100 Components A and B using an electric double-paddle mixer at low speed for 2–3 minutes until a uniform blend is achieved, without dilution. Apply the waterproof coating on an SSD (Saturated Surface Dry) condition. Apply the first coat at a rate of 0.80–0.90 kg/m² using a lamb’s wool roller. While the coating is still wet, roll and embed a 225 gsm Fiberglass Chopped Strand Mat, ensuring full bonding without air bubbles or wrinkles, and overlap joints by at least 5 cm at endpoints. Allow the first coat to dry for 3–4 hours. Apply the second coat at a 90° angle to the first coat at 0.70–0.80 kg/m² once the surface is dry enough to walk on. Additional coats may be applied as required to achieve a dry firm thickness a DFT of 1000 microns, with an overall material consumption of approximately 1.60 kg/m² over 2–3 undiluted coats. The coating should terminate below the drip mould on vertical surfaces. The system complies with ASTM and EN standards, achieving: Tensile Strength: ≥15 N/mm², Tear Strength: ≥100 N/mm,Dynamic Crack Bridging: EN 1062-7 & ASTM C1305-2016, Shore A Hardness: 85, Zero Water Permeability: at 10 bar (EN 12390-8:2019), Water Migration Resistance: No leakage, Low Temperature Flexibility: -20°C after 1000 hrs UV (ASTM D1970-2021), Solar Reflectance Index: 90 (ASTM E1980 for white). Peel Adhesion to Concrete (Wet Condition, 24 hrs): ASTM C794-12, The system confirms compliance with EN 13251:2016 for a 25-year service life when used with a 225-gsm fiberglass mat. It is backed by a 10-year waterproofing warranty from M/s Pidilite Industries Ltd. For vertical surfaces and parapet walls, apply Dr. Fixit Raincoat Classic or Dr. Fixit Raincoat Select as a protective waterproof coating. |
| 169 | Notes :1. Authorised applicator of the company with trained/ skilled workers will only be allowed to execute the work and the applicator will submit the authorization and experience certificate from the company. 2. The entire quantity of material will be calculated and brought on site as decided by Engr-in-Charge and will be accepted only post verification of PVs and Challan from the company through Mail. 3. Material will be kept in the custody of MES rep and will be issued to the authorised applicator as per requirement 4. Stage passing register will be properly maintained. 5. The contractor shall submit manufacturer generated 10 years warranty card during submission of RAR and Final Bill 6. A guaranty amount @ 10% will be kept as reserve till completion of warranty period and will be released thereafter.7. Any deterioration during the warranty period will be rectified by the manufacturer without any financial effect. 8. The applicator will inspectthe site after all such works and inspect for any shortcomings. If any shortcoming is there, the same will be intimated to the Dept. Dept will get the same rectified. 9. The applicator will start the work only after satisfying himself about surface condition A confirmation in this regard shall also be submitted to dept.10. Ponding test shall be carried out for 72 Hrs after completion of roof treatment and ponding shall be done by applicator with company technical rep as per manufacturer’s instruction and finally passed/ directed by Engr-in-Charge/GE. |
| 170 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed. |
| 171 | Point wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade, two run of single core cable for phase & neutral and one run of single core multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in and including new concealed PVC conduit terminated on and including new modular sunken box and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface flush with wall , comprising of One light /bell/buzzer point controlled by one switch or one fan point controlled by one switch &fan regulator, complete all as specified and directed. Note : Unit rate is inclusive of making good the disturbed surfaces by provding by wall putty/POP after mason work and finshing to match the original and nothing extra shall be paid on this account. Note :Unit rate is inclusive of cutting chases in wall /foor/PCC and making good the disturbed surfaces to match the original and nothing extra shall be paid on this account. |
| 172 | All as per serial item 164 herein before but for socket outlet 3 pin 6Amps on same board complete all as specified and directed |
| 173 | All as per serial item 164 herein before but for socket outlet 3 pin 6 Amps on independent board complete all as specified and directed |
| 174 | All as per serial item 164 herein before but One socket outlet three pin ,6/16 Amp, independent board, with 2.5 Sqmm (nominal area ) FRLSH cable & 2.5 Sqmm (nominal area ) cable as earth continuity conductor |
| 175 | Switch modular type (ISI marked), single pole, one way 6 Amps, one module (ISI marked), complete all as specified & directed. |
| 176 | Switch modular type (ISI marked), single pole, one way 16 Amps, one module (ISI marked), complete all as specified & directed. |
| 177 | Socket shutters outlet 2/3 pin 6 Amp modular type multi purpose two module (ISI marked), complete all as specified & directed. |
| 178 | Socket shutters outlet 2 in 1, 3/5 pin 6/16 Amp modular type multi purpose combined 2 module (ISI marked), complete all as specified & directed. |
| 179 | Modular switch type stepped fan regulator, single pole, 230 volt two module complete all as specified and directed. |
| 180 | Ceiling rose, PVC or polycarbonate of size 65mmx50mm three terminals (ISI marked) all as specified and directed by Engineer-in-charge. |
| 181 | Inverter type LED tube light batten 4 ft. 1 x 18/20 watt, 230 volts, Inverter type inbuilt Lithium ion battery with charging time 8 to 10 Hrs and back up time minimum 8 Hrs complete including fitting fixed on wall/ceiling and connection up complete with flexible cable white of suitable size and making necessary connection, fixed as in repair complete all as specified and directed. |
| 182 | Inverter type LED tube light batten 4 ft. 1 x 18/20 watt, 230 volts, Inverter type inbuilt Lithium ion battery with charging time 8 to 10 Hrs and back up time minimum 8 Hrs complete including fitting fixed on wall/ceiling and connection up complete with flexible cable white of suitable size and making necessary connection, complete all as specified and directed. |
| 183 | LED Mirror Lights fitting 17 watt cool/ warm white of approx size 534 x 93 x 33 mm , 220V AC decorative/model including fitting fixed on wall/ceiling and connecting up complete with flexible cable white of suitable size and making necessary connection complete all as specified and directed. |
| 184 | LED inverter batten light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with two core flexible copper conductor cable of suitable size fixed as in repair complete all as specified and directed. |
| 185 | LED sleek modern wall light fitting 24 watt, 220 V AC, scene switch type cool/warm white of approx size 868 x 93 x 33 mm, polycarbonate body, decorative/modern incl fitting fixed on wall/ceiling and connecting up complete with flexible cable white of suitable size and making necessary connection, fixed as in repair complete all as specified and directed. |
| 186 | LED building security light fitting 1 x 35 Watt new generation energy saving and environmental friendly long life LED street light made up of pressure diecast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP65 protection incl mounting bracket of suitable size and connection fixed as in repair complete all as specified and directed. |
| 187 | LED building security light fitting 1 x 35 Watt new generation energy saving and environmental friendly long life LED street light made up of pressure diecast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP65 protection incl mounting bracket of suitable size and connection complete all as specified and directed. |
| 188 | LED Bulkhead luminaires 1 x 9/10 Watt fitting in engineering plastic housing with clear prismatic diffuser complete with all accessories and connecting up with flexible cable white of suitable size and making necessary connection fixed as in repair complete all as specified and directed. |
| 189 | LED Bulkhead luminaires 1 x 9/10 Watt fitting in engineering plastic housing with clear prismatic diffuser complete with all accessories and connecting up with flexible cable white of suitable size and making necessary connection complete all as specified and directed. |
| 190 | LED panel recess mounted ultra slim 2'x2' - 36 watts ultra slim (white light) ceiling light, aluminum extruded housing with milky diffuser, heat exchanger unit, LED driver, surge protection complete suitable for perfect lighting cutting hole of required size in POP/false ceiling making good disturbed including taking down any type ceiling fitting complee all as specified and directed. |
| 191 | LED panel recess mounted ultra slim 2'x2' - 36 watts ultra slim (white light) ceiling light, aluminum extruded housing with milky diffuser, heat exchanger unit, LED driver, surge protection complete suitable for perfect lighting cutting hole of required size in POP/false ceiling making good disturbed complee all as specified and directed. |
| 192 | LED 18 W recess mounted indoor type back lit downlighter suited for any modern workspace of size not less than 6\\" round/square, fixed as in repair complete all as specified and directed. |
| 193 | LED 18 W recess mounted indoor type back lit downlighter suited for any modern workspace of size not less than 6\\" round/square, complete all as specified and directed. |
| 194 | Fresh air circular/ventilators fan made of sturdy engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm and connecting up including louvers including making necessary opening on stone /brick masonry wall of suitable size, finishing it properly and making good with matching colour with the surroundings provision of cable 3 core of suitable size from ceiling rose to fan complete all as specified and as directed. |
| 195 | Disconnecting and taking down old us sub main wiring complete with concealed conduit/batten of any type and size removing mtrls and making good distrubed surfaces of walls, floors etc complete all as specified and directed |
| 196 | Sub main wiring with two single core FRLSH PVC insulated and unsheathed cable with copper conductor of size 4 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 4 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing through and incl PVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfaces by providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed. |
| 197 | Sub main wiring with two single core FRLSH PVC insulated and unsheathed cable with copper conductor of size 6 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 6 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing through and incl PVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfaces by providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed. |
| 198 | Sub main wiring with two single core FRLSH PVC insulated and unsheathed cable with copper conductor of size 10 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 10 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing through and incl PVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfaces by providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed. NOTE FOR SERIAL ITEM NO 189 to 191: (i) Two runs of cable, one run of earth wire shall be considered as one running metre(ii) Cutting chases will be measured and paid separtely(iii) colour code shall be Red for phase, Black for neutral and green for earth |
| 199 | Sub main wiring with four single core FRLSH PVC insulated and unsheathed cable with copper conductor of size 16 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 16 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing through and incl PVC concealed conduit 32mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfaces by providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed. NOTE: (i) Four runs of cable, one run of earth wire shall be considered as one running metre(ii) Cutting chases will be measured and paid separtely(iii) colour code shall be Red for phase, Black for neutral and green for earth |
| 200 | Cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exceeding 10cm girth Complete all as specified and directed . |
| 201 | Disconnecting and taking down old unserviceble DBs, Junction Box, etc of any size complete along with all MCCB's ,MCB's etc all as specified and directed. |
| 202 | Vertical TPN distribution board double door flush mounting with provisions for MCCBs incomer upto 125 Amps & outgoing 4 way having IP 43 protection Complete all as specified and directed . |
| 203 | MCCB, 125 Amps, four pole, 3 phase , 16KA, 415 volt with adjustable thermal and maganetic release, with proper thimble complete all as specified and directed |
| 204 | Distribution board factory made sheet made sheet metal enclosure double door class IP-43 IK 09 with copper bus bar 240 Volts 4 way single pole and neutral link, complete all as specified and directed. |
| 205 | Distribution board factory made sheet made sheet metal enclosure double door class IP-43 IK 09 with copper bus bar 240 Volts 6 way single pole and neutral link, complete all as specified and directed. |
| 206 | MCB DB, IP 43 protection, powder coated double door with locking arrangement suitable for surface and flush mounting, 12 way SPN with 200 Amps busbar 240V completed all as specified and directed. |
| 207 | MCB, SPN , 240 volt, 40 to 63Amps, 10 KA , 'C' series including connection with suitable size aluminium / copper lugs complete all as specified and directed |
| 208 | MCB, SP , 240 volt, 40 to 63Amps, 10 KA , 'C' series including connection with suitable size aluminium / copper lugs complete all as specified and directed |
| 209 | MCB, SPN , 240 volt, 32Amps, 10 KA , 'C' series including connection with suitable size aluminium / copper lugs complete all as specified and directed |
| 210 | MCB ,SP , 240 volt, 6Amps to 32Amps, 10 KA , 'C' series including connection with suitable size aluminium / copper lugs complete all as specified and directed |
| 211 | Ceiling fans 1200 mm sweep, AC 230 V complete with blades, down rods and connected accessories, Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with (BLDC) brushless direct current motor with remote control and connection complete all as specified and directed. |
| 212 | Wall Mounted fans decorative type 400 mm black colour sweep, 230 V AC supply, 50 Hz, high performance, smooth oscillation, coper bound motor made of sturdy engineering plastic and metal ribs guard complete as per complete all as specified and as directed. |
| 213 | Single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one number single pole MCB 20 Amps , 240 Volts for AC/Geyser point complete all as specified and as directed. |
| 214 | Supply and install and hi wall split type inverter Air Conditioner 2.0 Ton capacity, hot & cold for all weather, EER 4 star rated, units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality complete all as specified and as directed. |
| 215 | Exhaust fan, steel body AC single Phase. 230V of size 300mm sweep , 1400 rpm, heavy duty with, blades, and frame and louvers including grouting nuts, fastners and provision of flexible coper cable 3 core from ceiling rose to exhaust fan complete all as specified and directed. |
| 216 | 32mm dia, double walled corrugated (DWC) HDPE duct pipe conforming to IS 14930 Part-II with anti rodent and non flame propogating properties of approved colour with fittings for cable protection from approval make complete , all as specified and directed |
| 217 | XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sqmm, 2 core, laid in trenches , sleeving through pipes of fixed on poles & wall or laid under floors inlcuding jointing with suitable size of alumunium lugs as specified and directed. |
| 218 | Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground vertically to a depth not less than 2.25 Metre below normal ground level (with top edge of earth plate not less than 1.5 Metre below ground level) connected to galvanized iron earth lead wire 4mm dia, (main earthing lead ) by means of galvanized bolts, nuts and washers all as shown in electrical plate no 5 of MES Schedule Part-I (1991) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe light grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia light grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick pre-cast RCC cover in 1 : 2 : 4 type B1 with 3 Nos 8 mm dia TMT bars both ways including desmantling of existing earthing complete all as specified & directed. |
| 219 | Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground vertically to a depth not less than 2.25 Metre below normal ground level (with top edge of earth plate not less than 1.5 Metre below ground level) connected to galvanized iron earth lead wire 4mm dia, (main earthing lead ) by means of galvanized bolts, nuts and washers all as shown in electrical plate no 5 of MES Schedule Part-I (1991) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe light grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia light grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick pre-cast RCC cover in 1 : 2 : 4 type B1 with 3 Nos 8 mm dia TMT bars both ways complete all as specified & directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 02, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 23, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysNov 25, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender