Tender For Special Repairs To Bldg No Ht-314 Of Corps Mt Under Age B/R-Ii Of Ge ( North ) Ambala Cantt
Tender Overview
Project Description
Tender For Special Repairs To Bldg No Ht-314 Of Corps Mt Under Age B/R-Ii Of Ge ( North ) Ambala Cantt
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 06-Nov-2026 | Amd BOQ | BOQ | 23-Nov-2026 |
| 2 | 23-Nov-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 30-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Schedule 'A' Part-I (B/R itmes)Demolition of cement concrete (un–reinforced) in ground floors and pavings not exe 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 2 | Material and labour 25 mm thick PCC 1:2:4, type B–0 as in sub base floor (using 12.50mm graded crushed stone aggregate), finished even & fair without using extra cement for base of tiling etc.,complete all as specified and as directed. |
| 3 | Material and labour non–skid ceramic coloured tiles joint free premium/1st quality (square/rectengular) 7 to 8 mm thick, area of each tile exc 0.11 sqm but not exc 0.18 sqm as in floor, set and jointed in neat cement slurry and pointed in coloured cement to match the surface over and including screed bed 15 mm thick in cement mortar 1:6 complete all as specified and as directed . |
| 4 | Material and labour glazed ceramic coloured tiles joint free premium/1st quality in vertical surfaces/ skirtings /dados of size 300 x 450 x 7 to 8 mm thick or set and jointed in neat cement slurry and pointed in white or coloured cement mixed with pigment to match over and including 15mm thick rendering on any type of faces of brick /concrete surfaces in cement mortar (1:6), complete, all as specified and as directed. |
| 5 | Supply and fixing Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick having zinc coating 150 grams per Sqm (Az 150) of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws incl dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed . |
| 6 | Supply and fixing Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa having zinc coating 150grams/Sqm (Az-150) as in roof ridge,valley gutter etc fixed with self tapping screws incl dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed . |
| 7 | Dismantling timber scantlings 40 sq. cm and over in section in any position ( unframed work ) , complete all as specified and directed. |
| 8 | Material & Labour for mild steel work as in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) of Fe -410 W ( Gde -E ) quality A including welding ,distance pieces, gusset plates ,cleats,base plates and neccesary fastenings , complete all as specified and directed. |
| 9 | Supply and fixing Mild steel screw bolts (machine made) of diameter of neck ( 16 mm to 20 mm ) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut exc 22.5cm and n exc 30cm long, complete all as specified and directed. |
| 10 | Supply and fixing Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts confirming to Fe -410 , complete all as specified and directed. |
| 11 | Material and labour for preparation of new steel and iron surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer , complete, all as specified and as directed. |
| 12 | Material and labour preparation of old decorated brick/concrete, plastered / unplastered surfaces of walls by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying two coats of cement base paint on the wall, pillars, cornices etc complete all as specified and as directed. |
| 13 | Material and labour for Hard core 100 mm thick, using broken bricks of guage n.exc. 63mm, deposited, spread and levelled in layeres n.exc. 15 cm thick each layer, watered and rammed to a true surface, as in below sub base, plinth protection and ramp, complete all as specified and as directed. |
| 14 | Material and labour for providing 75 mm thick cement concrete 1:3:6, type C–1 (using 20mm graded crushed stone aggregates) as in plinth protection laid in alternate bays (n exc 2 Sqm each) and finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight , complete, all as specified and as directed. |
| 15 | Material and labour 100 mm thick PCC 1:4:8 Type D–2 using 40mm graded crushed stone aggregate as in sub base of floor/ hard standing etc and finished even and fair without using extra cement , complete all as specified and directed. |
| 16 | Material and labour for vibratory rubber moulded coloured precast concrete interlocking paver block, any shape and size conforming to IS 15658-2006, ISI marked of 60 mm thickness, grade M-35 with grey cement and pigments over and including a layer of sand cushioning, 25 mm thick , complete all as specified and directed. |
| 17 | Material and labour for brick work with sub class 'B' bricks old size, class 7.5 designation, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 including dismentling of brick work built in cement mortar or cement lime mortar including all quoins, arches, pillar etc but excluding ashlar facing, dressed stone work and precast concrete articles , complete all as specified and as directed . |
| 18 | Supply and fixing providing cement concrete (1:2:4) Type B1 using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating , complete all as specified and directed. |
| 19 | Material and labour for PCC 1:3:6 C–1 (using 20mm graded crushed stone aggregate) as in surface channel or drain incl using of necessary form work for fair finish , complete, all as specified and as directed. |
| 20 | Material and labour Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, includingforms, moulds, mitred/stopped ends etc., complete, all as specified and as directed. |
| 21 | Taking down chowkats or frames with shutter area not exceeding 1.50 Square meter (without taking off shutters from the frames) and removing from site, including cutting holes for taking out existing hold fasts and making good the disturbed portion of jambs and adjoining surfaces to match with existing finish complete all as specified and as directed . |
| 22 | Taking down chowkats or frames with shutter area exceeding 1.50 Square meter and not exceeding 4.00 Square meter (without taking off shutters from the frames) and removing from site, including cutting holes for taking out existing hold fasts and making good the disturbed portion of jambs and adjoining surfaces to match with existing finish complete all as specified and as directed. |
| 23 | Supply and fixing of Pressed steel frames made of 1.25mm thick MS sheet of profile 125x60mm for door and window frames with double rebate including lock strike plate, shock absorber, 20mm dia 60mm long MS conduit for housing of a drop bolt, treating of internal surfaces of chowkhats with coal tar or black paint including hinges, hold fasts/lugs etc complete all as specified and as directed . |
| 24 | Supply and fixing of 35mm thick second class hard wood plain framed panelled shutters (any number of panels ), with panels of timber flat on both sides (feather edge), or of veneered particle board medium density wood wood particle board with commericial face veneers and fitted to chowkats complete all as specified and as directed . |
| 25 | Material and labour for factory made 35 mm thick 2nd class hard wood glazed and skeleton shutters,open rebated and prepared to receive glass , gauze etc. (without sash bars) ,edges of framing plain chamfered or rounded , fitted with cut and mitred beads for securing glass etc size of members of shutters as specified in SSR Part-I, Section-8, clause 8.24 (a) (wood shall be kiln seasoned and chemically pressure treated) complete all as specified and as directed . |
| 26 | Material and labour for preparation of new wooden surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, complete, all as specified and as directed. |
| 27 | Supply and fixing of 150 mm long, aluminium anodised, barrel tower bolts of extruded section , complete all as specified and directed. |
| 28 | Supply and fixing of 150 mm long aluminium handle, cast type, anodised , complete all as specified and directed. |
| 29 | Supply and fixing 250mm long aluminum alloy, anodized sliding bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminum alloys to door shutter ,complete all as specified and as directed. |
| 30 | Supply and fixing in repair 140 mm floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, complete all as specified and directed. |
| 31 | Supply and fixing of in repair Aluminium body hydraulically regulated Door closer universal type, suitable for door shutters of 851 to 1000 mm in width & of weight between 61 to 80kg complete all as specified and directed . |
| 32 | Supply and fixing stainless steel curtain rod 25mm dia having wall thickness 1.00mm fixed with and including stainless steel decorative brackets, two lotto for each rod length at both end etc as in repair complete all as specified and as directed . |
| 33 | Supply and fixing of Steel window 1.25mm thick box type ERW hollow P section of each frame size 60mmx25mm double rebated comprises of glazed & gaused Skelton shutter ERW section 50mmx20mm & 1mm thick with one openable leaf consisting of two number sash bars of T-Section 20mmx3mm complete welded to frame with one vertical mullion of ERW box type T-Section of size 60mmx25mm and 1.25mm thick with following fittings welded to the frame shutter :- i) Hold fast 150mm long mild steel flat iron 12x3 mm made to shape- 04 Nos per window ii) Handle of Z section 20mmx25mm, 100mm long – 01 No per leaf. iii) MS tower bolt 150mm long 2 No per leaf. iv) Z section 20mmx25mm, 100mm long stopper – 01 Nos per leaf. (v) Cleat 55 mm long of solid square 15x20x.63mm square - 01 Nos per leaf vi) pintol hinges 12 x 75 mm - 2 Nos each leaf vii) 10mm square Guard bar @ 10 cm c/c.(viii) 25 x 3 mm flat iron for joint of both frame wiremesh & Glazed welded inner side and outer side of frame (ix) Two coat of Synthetcitc enamel paint over one coat of primer (x) 0.36mm nominal dia of stainless steel wire mesh and average width of aperture of 1.40mm fixed in glazed / gazed skelton shutter of window(xi) 3mm thick sheet glass, ordinary quality and with oil putty in Square n. exc 0.5 sqm in each pane fixed in glaxed / gazed skelton shutter of window.(xii) Fabrication and fixing arrangements as per specification including cutting holes and making good dismantled portion in PCC 1:2:4 type B-1 /cement plaster 1:4 as require and make finish good to the existing surface complete all as specified and as directed by the Engr-in charge. |
| 34 | Taking down cement or cement lime plaster of any description on brick or stone walls etc including racking out joints, hacking for key scrubbing down with water etc complete all as specified and as directed . |
| 35 | Material and labour for Rendering 10mm thick in cement mortar (1:6) on any face of brick walls or concrete surfaces, finished even and smooth (without using extra cement) including preparation of new plastered surfaces wall and applying two coats of acrylic distemper over a coat of primer complete all as specified and as directed. |
| 36 | Material and labour for 15mm thick rendering in cement mortar (1:4) on any face of brick walls or concrete surfaces, finished even and fair (without using extra cement) including Preparation of new plastered surfaces and applying two coats of cement base paint over a coat of chalk white primer complete all as specified and as directed. |
| 37 | S & F GI Metal Suspended ceiling of approved materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm centre to centre and cross “T” of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross “T” of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm centre to centre along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint complete for all heights as per specifications including 4mm thick HPSC pre-prime non asbestos fibre cement building board (E-classic or equivalent) decorative finish fixed to frame work with holding down clips in false ceiling complete all as specified and as directed |
| 38 | Schedule 'A' Part-II (E/M itmes)Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete including all fittings and fixtures such as switches, pendant, lamp holder, socket outlet, etc and removing unserviceable materials from site of work and making good disturbed surfaces of walls, floors with cement mortar and white/colour wash to match with existing surfaces etc., complete all as specified and as directed . |
| 39 | Material and labour for point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked with multi stranded copper conductor drawn through and including medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, concealed on wall/ceiling surfaces and including provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade, ISI marked with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes modular type of size/modules as required at site with earth dolly (boxes shall be galvanised or painted with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally) including provision of new covered plate over sunken box for housing the modular switches , modular socket outlets,modular fan regulators etc. for one light/fan/exhaust fan/bell point controlled by one way switch, complete all as specified and as directed by Engineer-in-Charge. Note :- a) All chases will be cut by chase cutter only b) Switch, socket outlet and fan regulators to be measured and paid for separately . |
| 40 | Description all as per serial item No.39 here-in-before but for One 3 pin 6 Amps socket outlet controlled by one switch on independent board. complete, all as specified and as directed. |
| 41 | Description all as per serial item No.39 here-in-before but for One 3 pin 6 Amps socket outlet controlled by one switch on same board, complete, all as specified and as directed. |
| 42 | M & L for concealed point wiring complete with 2.50 Sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed cable 1100 volts grade drawn through and including medium grade, ISI marked, PVC conduit,medium grade ISI marked not less than 20 mm dia with accessories fixed concealed/surface type on wall/ roof/ ceiling and including provision of 2.50 sqmm single core PVC insulated, unsheathed cable FRLS-H, 1100 volt grade ISI marked with multi stranded copper conductor green colour as earth conitnuity conductor and connected to common earth dolly with suitable size lugs, including mild steels sunken box or pressed steel terminal box or pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-1) of 1969 and IS:14772:2000 with earth dolly and coated with two coat of anti corrosive paint over a coat of red oxide primer both internally and externally with and including (provision of new) modular covered plate over sunken box for housing the modular switches, socket outlets., fan regulators etc with brass screws and brass washers and making good the disturbed surfaces as per existing for One power point 16 Amp, socket outlets controlled by on switch independently. Note:-1 Modular metal flush / sunken box, and for modular switch/ socket cover plate & sheet are inclusive in the item rate quoted. 2. Only switch, socket to be measured and paid seperately. |
| 43 | Supply and fixing of modular switch 1 module, single pole, one way 6 Amps flush type, 230 volts, complete all as specified and as directed . |
| 44 | Supply and fixing of modular switch 1 module, single pole, one way 16 Amps flush type, 230 volts complete all as specified and as directed .. |
| 45 | Supply and fixing of modular socket outlet multipin combined, 6 Amp, one way, two module, 230 volts complete all as specified and as directed . |
| 46 | Supply and fixing of modular socket outlet multipin combined, (6pin), 6/16 Amp, one way, two module, 230 volts complete all as specified and as directed . |
| 47 | Supply and fixing ceiling rose surface type 2/3 terminal polycarbonate, isolated body complete all as specified and as directed . |
| 48 | Supply and fixing as in repair electronic Fan regulator, modular 100 watts, 02 module, 230 volts , 50 Hz, AC supply suitable for ceiling fan any type/make/sweep, complete, all as specified and as directed . |
| 49 | Supply and fixing in repair LED batten fitting 18-20 watt, 4 feet, aluminium housing with electronic driver cool/warm type industrial model complete, connecting with copper conductor flexible cable from ceiling rose to connector of the light complete all as specified and as directed by the Engineer-in-Charge. Cat part No. LUMILINE+ BS20WLED865SPCSS of make Havells or equivalent in make given in Appx 'B'. |
| 50 | S&F LED Bldg Security Light Fittings of capacity 35 watt made up of die cast aluminium housing with black epoxy powder coating with cover heat resistance glass safety input voltage range 170 to 270 volts, industrial model with IP-65 protection and other connected accessories including service bracket of GI pipe 32 mm bore medium grade of length 0.9 mtr with MS clamps, bolts, nuts, and washers and suitable reducer for connecting fitting to GI pipe as required at site and two coats of synthetic enamel paint over one coat of red oxide primer on mild steel work and making electrical connection, including disconnecting and taking down existing old U/S fitting complete all as specified and as directed. |
| 51 | M&L submain wiring with 2 runs of copper conductor FRLSH PVC insulated unsheathed cable 1100 volt grade 6 sqmm drawn through PVC conduit medium grade ISI marked 25mm dia as per IS specification fixed concealed in wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 6.0 Sqmm FRLSH multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified including dismantling old and making good to the disturbed surface by plastering and two coat of distamper all as directed at site. Note : Two runs of 6 sqmm cable alongwith one run of 6 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length. |
| 52 | Supply and fixing MCB SP, 5 to 32 Amps, 240 volt,10 KA , 'B' curve as per site requirement including removing old unserviceable MCB complete all as specified and as directed . Cat part No 811008 to 811015 of make Indoasian or equivalent make given in Appx 'B'. |
| 53 | Supply and fixing MCB SPN, 40 Amps, 240 volt,10 KA , 'B' curve as per site requirement including removing old unserviceable MCB complete all as specified and as directed . Cat part No 811035 of make Indoasian or equivalent make given in Appx 'B'. |
| 54 | Supplying and fixing of VTPN (including MCCB 100 Amp 16 KA, four pole) distribution board 4 ways, fabricated out of thick high quality CRCA sheet. DBs shall be totally enclosed, suitable for 240V/415V, having polyurethane(PU) foam gasket to ensure IP-54 degree of protection for indoor application as per IEC 61439-3:2012(Cl. 10.3)/IEC 60529.DB shall be robust with tested for Impact resistance IK09 as per IEC 61439-3:2012(Cl.No. 10.2.6).DBs shall be provided with prefitted cement Guard. DB Door shall have detachable gland plates provided with proper knockout holes of 26mm/35mm diameter for intsertion of cable/conduits.Distribution Boards shall be provided with wire set of copper along with the insulated fork type bus bars.DB shall have reversible hinged doors and possibility to allow door opening from Left to Right or Right to Left for convenience on site. cat part No. 812040 & 830022 of make Indo Asian or equivalent in make given in Appx 'B'. |
| 55 | Supply and fix sheet metal MCB, DB, SPN 8 ways, with 200 Amps rated bus bar single pole and neutral with double door IP-43 fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection, including making smooth the disturbed surfaces including removing old unserviceable enclosure complete all as specified and as directed by the Engr-in-charge. Cat part No.811807 of make Indo Asian or equivalent in make given in Appx 'B'. |
| 56 | Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised earth lead of 4mm dia GI wire by means of bolts, nuts, check nuts and washers of galvanised iron.Earth wire protected by GI pipe 15mm bore(medium grade) and connected to main switch board or main control board as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm C/C with one handle for lifting made out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as directed by Engineer-in-Charge and earth testing on completion . |
| 57 | Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth for foundation etc or for shafts, wells, laying of cable etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed. |
| 58 | Returning, filling in, including spreading, levlling ,watering and well ramming in layers not exceeding 25 mm thick each layer, complete all as specified and as directed . |
| 59 | Removing surplus excavated material to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point, complete all as specified and as directed . |
| 60 | Material & Labour dry sand cushoning to cable i.e 8 cm before laying cable in trenches and 15 cm after laying the cable and compacting , complete all as specified and as directed.Note: punned thickness shall be measured for payment. |
| 61 | Supply and laying well burnt brick class-B laid flat to cover the cable with width equal to the length of cable and abutting each other for protection of cable , complete all as specified and as directed. |
| 62 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 4.0 core, complete all as specified and as directed. (Note :- excavation & earth work shall be measured & paid separately . |
| 63 | Taking down ceiling fan, cleaning the same and replacement of fan rod 15 mm dia of lenght 4 feet, including connection from ceiling rose to fan and refixing & hanging the same to make it operational, complete all as specified and directed. |
| 64 | Supply and fixing of LED flood light 70 watt 230 V, AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp.,complete all as specified and as directed. |
| 65 | Note:- Amount of credit of Rs.59,714.00 for retrieved materials is mentioned in Schedule of Credit Page No. 123 of tender doCubic metre ents in pdf form which will be deducted offline while acceptance of tender. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 5 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender