Tender For Construction Of Dining Hall Over The Existing Village Knowledge Centre Building For (100 Capacity) At Thittakudi In Thanjavur District.
Tender Value
Ref. Documents
Estimated cost
Bid Submission
16 Nov 2026
10 days left
EMD
22382
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Thanjavur → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Construction Of Dining Hall Over The Existing Village Knowledge Centre Building For (100 Capacity) At Thittakudi In Thanjavur District.
BOQ
| Sl. No. | Item Description |
| 1 | Supplying and erecting centering for plane surfaces such as RCC Floor Slab, Roof Slab, Loft, Landing Slabs, etc with necessary supports and strutting upto 3.60m height in all floors with all cross bracings using MS Sheets made of 10 gauge thick welded with MS angle of Size 25mm x 25mm x 3mm for boarding laid over steel adjustable span of size 2m x 2m (expandable upto 3.60m) and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick) , etc complete complying with standard specifications. Steel adjustable span and Steel Adjustable telescopic props shall be provided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid). |
| 2 | Supplying and erecting steel centering including necessary supports For plane surfaces such as rectangular or square RCC columns,sunshades etc. which require only nominal strutting using mild steel sheets made of 10 gauge thick welded with MS angle size 40mm x 40mm x 5 mm and supported by Steel Adjustable Telescopic Props of Size 2m x 2m (expandable upto 3.60m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick).etc..complete in all floors complying with standard specifcation. Steel Adjustable telescopic props shall be provided as directed by the departmental Officers. (Payment for centering shall be given after the concrete is laid). |
| 3 | Burnt Clay Hollow Brick (as per IS 3952-1988) with Rockwool Infill for Insulation for Walls, the brick having a size of 400 mm x 200 mm x 200 mm, having U (Thermal transmittance) Value of 0.6 (or lower) W/m2 K, having compressive strength nor less than 30Kg/Sqcm and water absorption not more than 10% jointed with ready mix build fast and eco friendly wet mix pre-polymerized / Polymer modified adhesive having compressive strength of not less than 50 kg/Sqcm and ensuring long lasting thermal insulation of according to european norms (EN1301-2), suitable fo high performance of external and internal concrete masonry wall, joint having thickness in thin layer of 2 mm to 4 mm between masonry units in superstructure including striking joints, racking out joints faces and scafolding, etc , |
| 4 | For First floor |
| 5 | Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification. (Contractor has to make his own arrangements for the supply of steel and binding wire) |
| 6 | For 1 Quintal |
| 7 | Burnt Clay Hollow Brick (as per IS 3952-1988) with Rockwool Infill for Insulation for Walls, the brick having a size of 400 mm x 200 mm x 200 mm, having U (Thermal transmittance) Value of 0.6 (or lower) W/m2 K, having compressive strength nor less than 30Kg/Sqcm and water absorption not more than 10% jointed with ready mix build fast and eco friendly wet mix pre-polymerized / Polymer modified adhesive having compressive strength of not less than 50 kg/Sqcm and ensuring long lasting thermal insulation of according to european norms (EN1301-2), suitable fo high performance of external and internal concrete masonry wall, joint having thickness in thin layer of 2 mm to 4 mm between masonry units in superstructure including striking joints, racking out joints faces and scafolding, etc , |
| 8 | For First floor |
| 9 | Supply and fixing of Pre fabricated MS trust (5’x21/2’), 2.5mm thick with Purlin (4’x2’) 2mm thick rested over the Base plate founded with 16mm foundation bolt. The top of the fabricated truss has been finished with Puff sheet (Sandwich Sheet) of 50mm thick, Top sheet : 0.35mm PPGL 70 GSM, JSW and Bottom sheet, 0.30mm PPGL 70 GSM, JSW brand. The density of the Puff Sheet will be of 40kg/m3 . The truss members should be coverd with metallic yellow Primer coat with enamel coating as per standard specification. |
| 10 | Paving the floor with best quality Double Charged Vitrified Tiles of size 600 x 600 x 8mm and variety conforming IS 15622 with water absorbtion less than 0.08% of approved colour and shade laid over cement mortar bed of 20mm thick in cement mortar 1:3 (one cement and three crushed stone sand) with required Cement Slurry and Mortar Plasticizer in all floors and the top pointed with Water Resistant Tile Epoxy Grout etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 11 | Plastering with Cement Mortar 1:5 (One cement and Five Plastering sand), 12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc. complete complying with standard specification and as directed by the departmental officers. |
| 12 | Painting two coats of newly plastered wall surface with ready mixed plastic interior/Exterior emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification and as directed by the departmental officers. |
| 13 | Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 14 | Supplying and fixing in position best approved of BIS quality 110mm dia PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of \\"U\\" clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification and as directed by the departmental officers |
| 15 | Supplying and fixing Mild Steel grills for windows, ventilators etc.,complete complying with standard specifications and as directed by the departmental officers. |
| 16 | Providing UPVC (Un-Plasticized Polyvinyl Chloride) Door: Providing and fixing casement doors fabricated from un-plasticized polyvinyl chloride (UPVC) sections. Profiles: The profiles should be three chamber system which provides high insulation properties with outer frame 60mm x 55mm with an outer wall thickness of 2.4mm. The window unit should be designed with all corner joints mitred and fusion welded. Windows should be steel reinforced with 25 x 24 x 25mm steel reinforcement with a thickness of 1mm to have dimensional stability. The sash should be of 60 x 102mm. The mullion should be of 60 x 74mm. The profiles should have co-extruded seals. Hardware: All the hardware like friction stays, handles should be screwed with self tapping screws. The handles, locks should be designed so that they cannot be released from outside. Glazing: The window system should be glazed with 5mm plain float glass / 6mm bison lam Installation: The profiles should be cut to length and welded 45 degrees. The window should be designed such that the water drainage does not pass through the reinforcement chamber. The window system should be fixed directly to the plastered brick wall using self expanding nylon plug and driving ms electroplated screws into plug. |
| 17 | Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work |
| 18 | Supplying, laying and jointing UPVC pipes of Class 5 (having working pressure of 10 kg/sq.cm) conforming to IS 4985- 2000 of approved quality and best variety of the following dia including cutting, and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) in accordance with IS 7634-3(2003) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications. The UPVC pipes shall be got approved by Executive Engineer before use on works. - Internal water supply - above ground level. |
| 19 | 25mm dia UPVC Pipe |
| 20 | Supplying UPVC Specials in water supply arrangements (both in internal and external water supply arrangements |
| 21 | 25mm dia UPVC Elbow |
| 22 | 25mm dia UPVC Tee |
| 23 | 25mm x 20mm dia UPVC Reducer Elbow |
| 24 | Supplying and fixing in position best quality SS Sink of size 1200x550x180mm [The sink and specials should be got approved by the Executive Engineer before use on works] |
| 25 | Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. (The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level |
| 26 | 110mm dia PVC soil pipe |
| 27 | Supplying and fixing in position PVC specials of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the PVC soil stacks, dismantling the masonry or RCC works and re-doing the dismantled portion to original condition etc., complete complying with standard specifications. (The PVC specials should be got approved by the Executive Engineer before use on works). |
| 28 | 110mm dia PVC Bend |
| 29 | 110mm dia PVC Door Bend |
| 30 | Wiring with 2 x 1.5 Sqmm. PVC insulated unsheathed FRLS SC copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessoires with TW switch box and 5A FT switch in flush with wall with 3mm thick hylum sheet cover for making good of the concealed portion with suitable colour for PVC concealed light point / fan point (for electronic regulator) |
| 31 | Wiring with 2 x 1.5 Sqmm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall with 150mm x 100mm x 113mm TW switch box with 3mm thick hylem sheet cover for 5A 3 pin non inter locking wall socket with 5A flush type switch with continuous earth wire connection of 1.5 Sqmm copper wire and making good of the concealed portion with suitable colour for concealed PVC plug point |
| 32 | Wiring with 2 x 4 Sqmm. PVC insulated SC unsheathed FRLS copper conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall with 150mm x 100mm x 113mm TW switch box with 3mm thick hylem sheet for 15A 3 pin non inter locking wall socket with 15A flush type switch with continuous earth wire connection of 4 Sqmm copper wire and making good of the concealed portion with suitable colour for concealed power plug point |
| 33 | Supply and fixing of fancy glass shade and 15 W LED Bulb |
| 34 | Supply and fixing of single box type 4'40W fluorescent fitting complete with copper choke and condensor with TW round blocks on wall or ceiling with flu tube with PVC unsheathed FRLS copper leads from terminals to the fitting |
| 35 | Supply and fixing of 1200mm (48\\") AC ceiling fan complete with stepped electronic 300W regulator with 300mm down rod on the existing clamp. |
| 36 | SUB TOTAL |
| 37 | GST @ 18% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 02, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 16, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysNov 17, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender