Tender For Upgradation Of Infrastructure Arrangements For Mncu Ward At 4Th Floor Of Mch Building In Government Head Quarters Hospital At Tirupathur In Tirupathur District.
Tender Value
17.05 Lakhs
Estimated cost
Bid Submission
17 Nov 2026
15 days left
EMD
17100
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Tirupathur → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Upgradation Of Infrastructure Arrangements For Mncu Ward At 4Th Floor Of Mch Building In Government Head Quarters Hospital At Tirupathur In Tirupathur District.
BOQ
| Sl. No. | Item Description |
| 1 | Supplying and Laying Polyester, Washable and stain free cloth(Bio-Active fabric washable germfree suitable for dialysis room) curtain system with maximum curtain cloth height 230cm ( top 30cm white colour net and 200cm light blue colour as per approval) stitching with stiffener tape, pleats, ironing and laying around Each bed using sliding wheels two nylon rollers, nylon axil and tangle free nylon’swivel stem with chrome-plates stell hook, curtain track should be supported in roof using 20x20mm,2mm thick sixed aluminium tubes same space with end caps in two sides using all necessary fittings. |
| 2 | As per the direction of engineer in charge including conveyance to site, laying in line and level, sealing all cutting in false ceiling with powder coated MS cup, all leads and lifts including all labour charges etc., complete.(unpleated length of the cloth measurement will be considered in cloth measurement)/ supplying and fixing powder coated 20mm dia . GI round tube hanging support of required length (app. length 1.10m)one end fixing from slab by using 6mm dia expansion bolt at a distance not more than 2m,c/c down end fixed powder coated aluminium channel frame 45x20mm x1mm thick section by using SS screw as per the Direction of Engineer in charge including conveyance. (Dr.No.80B/2025-26) |
| 3 | Medical Gas Copper Pipeline arrangement to hang on the wall of socket type connection installation of seamless cleaned and degreased non arsenical phosphorous gas copper pipe line with saddles complete with brazing work including all copper fitting (tee, elbow, reducer, coupling). The copper pipelines should be tested suitable for a steam of working pressure of 17.34 kg. / cm2 (17 bar) and confirm to BS 864 Standard with specially made for brazed socket type connection. The medical gas copper pipeline should be tested as per standard and commissioning after painting as per International Code No. IS 2379/1963 Table-V. The pipelines installed at the various wings and floors etc., complete as directed by the Departmental Officers as per IS Code 12827 / 1989 & ISO 7396 / 1987 Specification. |
| 4 | 10mm OD 0.90mm thick copper pipe |
| 5 | 15mm OD 0.90mm thick copper pipe |
| 6 | Brass Isolation Valve suitable for the copper pipe and should be of non lubricated 90 degree turn lever ball valve of reputed make, conneced in line with medical gas pipe line system by using suitable size brass valve adopter union, ferrule, nipple, rubber \\"O' ring, tapion lap and etc. All pipe line regulators shall be capable of controlling pipe line pressure and must compatible with the requirements specified in IS 12827-1989. All valves should be pneumatically tested for twice the working pressure for the gas line as per IS Code 12827 / 1989 & ISO 7396 / 1987 Sepecification. 15mm Isolation Valve |
| 7 | Bed Head Panel of size 1m length, height 0-0.30 cm and depth of 4\\". The aluminium powder coated with requirement colour for provision points of O2-2 Nos., Air 1 No., Vaccum 1 No. with double electrical socket with switch 2 Nos. with 2 set with 1V - bottle holder fixing to the wall hanging including monitor stand etc., complete. |
| 8 | Supply and Installation of 74 mm Drywall Partition with two layers of MGO-Magnesia Cement board, square edge, Magnesia cement core panels of size 1200x2400x12mm, volume density 1000kgs/m3, weight 12kg/m2 installed by using Auminimum channel.The Aluminimum channel 1.5mm thick, length 3600mm fixed to the floor and soffit ceiling with suitable fasteners at 300mm staggered centers. Silica noise and fire rated silicon sealant/Matt to be caulked along the lining frame before fixing the Aluminimum channels. Then Aluminimum channel of 25x50x1.5mm thick should be placed into the floor/head channel positioned vertically at 600mm centers. |
| 9 | Extra reinforcement to be provided at openings (doors, windows, etc). Synthetic Polyfiber, 1000 gsm density, thickness 50mm, width 600mm is held in position with Stick S7 dab spots inbetween Aluminimum Channel. Magnesia Cement board 1200X2400X12mm is fastened onto the Aluminimum Channel behind in staggered manner using self drilling (drill tip) fasteners at 300mm centers. 4mm gap should be maintained between boards on all sides. Repeat the process similarly on the other side of the framework to get 74 mm thick partition system. 4mm gap between boards to be filled in full depth by using Jointing Compound as per given recommendations and guidelines.Technical Parameters Fire (Class) – 1 & P, Acoustics - STC 43, Thermal conductivity(W/mk)– 0.118, Climate (°C, RH) – 50, 95, Light reflectance (%) – Paint dependant ,Green (VoC,RC %) – Low, 30 complete and as directed by the departmental engineers. |
| 10 | Supplying, fabricating, erecting and fixing Hilux (or) Equivalent Board False Ceiling upto a ceiling height of 4.5m from floor level Using perforated sheets (10mm thick) etc., complete. |
| 11 | Supplying and laying Vinyl flooring including labour charges etc., complete and as directed by the departmental officers. |
| 12 | Supply and fixing of Ordinary Vertical Blinds etc., Complete and as directed by the department officers.. |
| 13 | Supplying, fabricating and fixing in position factory made Stainless Steel Flush Door Shutter 35mm thick using SS 304 Grade 1.6 mm thick, Stainless Sheets on both sides (Equivalent to IS 6911-04 Cr. 19, Ni 9) minimum 8-8.5% nickel and 18% chromium sourced from original stainless steel manufacturer with view panel size 30mm x 45mm made up of 6mm thick clear toughened glass fitted with double side adhesive tape and finished with dowconing silicon sealant, floor spring for each shutter, consealed tower bolt, suitable stainless steel locking arrangement and other necessary furniture fittings of approved quality. The vertical styles and other frame members and cross stiffeners shall be of same quality stainless steel box section of suitable size and thickness with proper core material as prescribed by the Departmental Officers |
| 14 | Fabricating Supplying and fixing in position of Aluminium anodised natural colour matt finish 1/3rd fixed glazing 2/3rd prelaminated board of Aluminium partition of size 3.50 x 2.88m. The outer frames Outer frame: 63.50x38x3mm@ 1.72 kg/m, Centre mullions: 63.50x38x3mm@ 1.55 kg/m, Alu. Clips: 17.27x17.15x1.50mm @ 0.175kg/mg/m for intermediate vertical mullion 90cm c/c. Horizontal mullion at 1.00m 2.10m covered with 5.5mm thick plain glass with neccessary aluminium clips of size 17.27x17.15 x1.50mm @ 0.176kg/m and with required rubber beading etc., including necessary dismantling holes in RCC column, masonry wherever in necessary with power drills to the extent required and made good the damaged portion in good condition after fixing etc... complete complying with standard specification and as directed by the deparmental officers. All the aluminium sections should be anodised not less than 15 microns as ISI specification1868/1962 / and should be gotapproved by Executive Engineer before use. |
| 15 | Fabricating Supplying and fixing in position of Aluminium anodised Powder Coated of single leaf door with half panelled with 12mm thick both side laminated particle board at bottom and half glazed using 5.50mm thick Plain glass at top.The outer frame shall be with aluminium box section 101.60x44.45x3.18m at 2.319kg/m and Shutter frame made of section Vertical & Top rail: [email protected] kg/m and Bottom rail: 100x44.45x2.50mm@ 1.974 kg/m, Lock rail : 50x44.45x2.5mm @ 1.292 kg/m,Alu. Clips: 17.15x17.27x1.50mm @ 0.176 kg/m,Alu. Handle: 100x30mm @ 0.988 kg/m and necessary accessories such as aluminium clips, rubber beading, PVC felt, handle for a length of shutter (both sides), locking arrangements, |
| 16 | furniture fittings such as aluminium tower bolts-250x12mm - Eachs., aluminium tower bolt 200x12mm - 1No., aluminium Hydraulic door closer - 1No ., lock-1No., Door stopper with rubber bushincluding cost of materials labour charges and power consumption charges required for fabrication including chipping, dismantling and making hole to the required extent in RCC column, beams, masonry with power drill wherever necessary and redoing the damaged portion to the original condition after fixing etc., complete complying with standard specification and as directed by the deparmental officers.. All the Alu. Section are to be anodised with matt finish under electricaly controlled conditions in accordance with IS 1868/1962 for an average anatic film thickness of 15 microns etc., complete. Aluminium sections, and furniture fittings shall be got approved by the Executive Engineer incharge. a) with automatic Door closure & hings |
| 17 | Supplying and fixing in position 15mm dia brass SS Elbow Action Tap (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary. (Taps should be got approved by the Executive Engineer before use on the works) |
| 18 | SS Elbow Action Tap of size 15mm |
| 19 | Long body Tap |
| 20 | CP two way bib cock with Health faucet |
| 21 | Supplying and fixing in position best quality Stainless Steel sink of SS Sink of size 1200 x 550 x 180mm including cost of 32mm dia CP waste coupling, 32mm dia PVC waste pipe with rubber plug and chain, 15mm dia brass nipple including fixing the sink in position and testing for leakages etc., complete complying with standard specifications excluding CI brackets. [The sink and specials should be got approved by the Executive Engineer before use on works] |
| 22 | Supplying, laying and jointing UPVC pipes of Class 6 (having working pressure of 12.50 kg/sq.cm) conforming to IS 4985- 2000 of approved quality and best variety conforming to BIS of the following dia including cutting and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) in accordance with IS 7634-3 (2003) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications. The PVC pipes shall be got approved by Executive Engineer before use on works - External water supply above ground level / Below ground level. |
| 23 | 25mm UPVC PIPE |
| 24 | Supplying UPVC Specials in water supply arrangements (both in internal and external water supply arrangements |
| 25 | 25mm ELBOW |
| 26 | 25mm Tee |
| 27 | Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. (The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level |
| 28 | 75mm PVC PIPE |
| 29 | Supplying and fixing in position PVC specials of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the PVC soil stacks, dismantling the masonry or RCC works and re- doing the dismantled portion to original condition etc., complete complying with standard specifications. (The PVC specials should be got approved by the Executive Engineer before use on works). |
| 30 | 75mm ELBOW |
| 31 | 75mm Tee |
| 32 | Supplying and fixing in position first quality and approved variety of Gun metal Gate Valve with BIS make of the following dia including cost of shellac, thread balls, etc., complete complying with standard specifications (for both internal and external water supply arrangements). The valves to be used on work shall be got approved by the Executive Engineer before use on work. |
| 33 | 25mm gate valve |
| 34 | Supply and fixing of Workstation Table of size 2400x600x800mm with the following specification. The table is made out of 20gauge electro galvanized material for the cabinet with epoxy powder coating of thickness 60-80microns. The panel units, shutter and the entire body shall be of 20 gauge steel with interlocking type construction to form a rigid integral structure. Each shutter will have locking facility. The top is smooth finished JET black granite 18+/_ 1 mm thick with edges having round profiles. The rate is inclusive of cost of all materials labour charge for fixing in position with all necessary fittings and finishing neatly etc., complete complying with standard specification and as directed by departmental officers. (WE.No:29WE/2025-26) |
| 35 | GST 18% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 02, 2026
11:30 IST
Tender Published
Tender notice published.
TodayNov 17, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysNov 17, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 15 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender