Tender For special Repair Of Roof Joints (Ridge) In Bldg No T-15 At Station Wksp Eme Under Ge (West) Delhi Cantt-10
Tender Value
19.39 Lakhs
Estimated cost
Bid Submission
23 Nov 2026
15 days left
EMD
38780
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for special Repair Of Roof Joints (Ridge) In Bldg No T-15 At Station Wksp Eme Under Ge (West) Delhi Cantt-10
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling structural steel work including doors, gates but excluding framed truss etc complete all as specified and directed. |
| 2 | Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings in any position complete all as specified and directed. |
| 3 | S&F Mild Steel in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc, of Fe 410-W (Gde E-250) Quality 'A' including fabrication, erraction and fixing complete all as specified and directed by Engr-in-Charge. |
| 4 | S&F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick (coating of sheet not less than 150 GSM) of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, slightly/completely rounded or chamford as per site requirement fixed with self tapping screws complete all as specified and directed. |
| 5 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick coating of sheet not less than 150GSM of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and as directed. |
| 6 | Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required in hearths covering to door shut ters; covering to door chowkats (frames) including round headed screws, clout nails or rivets and fixed to wood or steel members, etc, with plain 40mm lap joints or welded/riveted seams including banding, turning up, mitred angles, stopped ends, outlets, etc. complete all as specified and directed. |
| 7 | Demolition of brick work built in cement mortar of any specification and in any position complete all as specified and directed. |
| 8 | M&L for Brick work in cement mortar 1:6 using sub class 'B' old size burnt bricks, straight or curved on plan exceeding 6 metre mean radius complete all as specified and directed. |
| 9 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 10 | M&L Glazed ceramic coloured joint free tiles of size 450mmx300mm, 6 to 7mm thick on vertical surfaces of walls such as skirting dado etc and jointed in neat cement slurry and pointed in white cement to match laid over and including 10mm thick backing coat in CM 1:4 complete all as specified and as directed. |
| 11 | M&L for Non-skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) coloured tiles area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match Screed bed or beeding layer mortar 20mm thick in CM 1:6 for laying floor finishes complete all as specified and as directed. |
| 12 | M&L for 10-15mm thick Endura tiles in floor with roughening of surface, laid and jointed with grey cement slurry mixed with pigment to match the shade of the tiles over and including Screed bed or beeding layer of mortar 20mm thick in CM 1:6 for laying floor finishes Including Demolition of old Tiles complete all as specified and as directed. |
| 13 | Demolition of unreinforced cement concrete in ground floor and pavings n.exc, 15cm thick (below or above GL) complete all as specified and directed by Engineer-in-Charge. |
| 14 | M&L for 75mm thick cement concrete 1:3:6 (Nominal mix) with 40mm crushed stone aggregate finished even and fair, laid to slope of 1 in 12. it shall be laid in alternate bays, each bay not exceeding 3m length with joint to be filled with bituminous mastic filling comprising a mixture of 1 part of heated hot blown bitumen 85/25 penetration and two parts heated sand. the toe of plinth protection of size 75mm deep and 75mm wide shall also be of PCC 1:3:6 type C2 complete all as specified and directed. |
| 15 | M&L Powder coated GI false ceiling with 600mmX600mm with and including 'E' not less than 4mm suitable size (as per sample), fixed with and including galvanised iron powder coated inverted 'T' or 'L' section (Concealed GI frame work) of Cicage metallic or equivelent suspended from ceiling with provision of galvanised iron wire 4.5mm dia centre to centre distance not less than meter and self tapping screws including butterfly clips, hold clips for fixing the boards to frame including Dismantlaing of false ceiling complete all as manufacture's instruction complete all as specified and as directed. |
| 16 | M&L for 10-12mm thick rendering with ready mix mortar of approved make on brick work or concrete surfaces on wall, finish the surface even and smooth without using extra cement as whole or in patch etc including taking down cement plaster on brick walls etc including raking out joints hacking for key scrubbing down with water etc all as directed, rubbish of the premises complete all as specified and directed. |
| 17 | M&L preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper over a coat of putty and including a coat of alkali resistance primer complete all as specified and directed. |
| 18 | M&L for 15mm thick rendering with ready mix mortar of approved make on brick work or concrete surfaces on wall, finish the surface even and smooth without using extra cement as whole or in patch etc including taking down cement plaster on brick walls etc including raking out joints hacking for key scrubbing down with water etc all as directed, rubbish of the premises complete all as specified and directed. |
| 19 | M&L for Preparation of new plastered surfaces and applying two coats of cement base paint over and including a coat of chalk whiting primer on plastered surfaces, preparatory to distempering primer complete all as specified and directed. |
| 20 | M&L for preparation of old decorated plastered surfaces of walls etc and applying two coats of oil emulsion distemper on wall surfaces complete all as specified and directed. |
| 21 | M&L preparing new steel or iron surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 22 | M&L Preparing old surfaces of steel of any description, not other wise described, over 10cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed. |
| 23 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should bemade as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed. |
| 24 | Taking down old MCCB , TPN DBs , SPN DBs, sp mcb & main switch/ enclosure box of any make and type from the site and making good surface complete all as specified and directed. |
| 25 | Taking down old submain wiring of any size and make from the site and making good surface complete all as specified and directed. |
| 26 | Disconnecting elect connection and taking down of ceiling fan/ Exhaust fan of any make and any height, dismantling blade and removing fan alongwith blade for depositing in MES store yard complete all as specified and directed by Engr- in- Charge. |
| 27 | M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through and including non-metalic rigid new PVC conduit medium grade ISI Marked not less than 20 mm dia and all conduit accessories concealed in wall on surface in ceiling/fixed to roof/truss/columns etc and including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty, fabricated modular metal flush box, concealed in walls with suitable modular inner and outer plate for housing switches , socket out let and fan regulators etc, complete all as specified. |
| 28 | (a) One light /Ceiling fan/exhaust fan point controlled by one switch.complete all as specified and directed. |
| 29 | (b) One 3 pin 5 Amps socket outlet point controlled by one No one way switch on independent board. complete all as specified and directed. |
| 30 | (c) One 3 pin 5 Amps socket outlet point controlled by one No one way switch on same board. complete all as specified and directed. |
| 31 | M&L point wiring with PVC unsheathed multi stranded copper conductor cable 2.5 sqmm FRLS 1100 Volts in New PVC concealed conduit medium grade ISI Marked not less than 20 mm dia in new M S steel terminal boxes modular including one run of using 2.5 sqmm FRLS 1100 Volts copper conductor cable as earth continuity connected to common earth for one 15 A switch socket power point, all as specified |
| 32 | Supply and fix in repair Sub main wiring complete with two runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 20 mm dia non metallic rigid PVC conduit and conduit accessories(Concealed)/ Surface in walls all as specified and as directed. |
| 33 | M&L switch Modular type 6 Amp SP one way ISI marked complete all as specified |
| 34 | M&L switch Modular type type 16 Amp SP one way, ISI marked complete all as specified |
| 35 | M&LModular type socket outlet 5 pin 6 Amp flush type, ISI marked complete all as specified |
| 36 | M&L Modular type socket outlet 2 in 1,5 pin 6/16 Amps, ISI marked complete all as specified |
| 37 | M&L ceiling rose 3 phase PVC polycorbonate,isolated body, complete all as specified |
| 38 | S & F Modular electronic fan regulator step type,1 module ,360 degree rotation complete all as specified and directed by engr-in charge. |
| 39 | M&L for earthing of machinery/equipment/panel/installed at power house/subatation, complete with galvanised steel earth palte electrode 600 x 600 x 6 mm thick buried directly in ground (Earth pit not less than 2.5 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connecting to galvanised iron strip 25 x 4 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel and earth protected by 40 mm dia GI pipe medium grade and connected to distribution board/earthing test point all as shown in electrical plate No.3 of SSR Part-I )2009) and testing on completion all as specified and directed. |
| 40 | Supply & fix in repair factory made epoxy powder coated Distribution Board VTPN-4 ways with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removeable gland plates with knockouts and suitable for one VTPN- MCCB 125/160 Amp as incomer and 40 to 63 Amp SP MCBs outgoing complete all as specified and conforming to IS : 8623. |
| 41 | M&L in replacement MCCB 125 Amps, 16 KA , 4P, 415 Volts, 50Hz , with thermal magnetic setting complete all as specified and directed. |
| 42 | Supply and fix in replacement MCB DB SPN 12 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as specified and directed. |
| 43 | Supply and fix in replacement MCB DB SPN 8 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as specified and directed. |
| 44 | M&L MCB SPN 40 Amp \\"B\\" curve, 10 kA complete all as specified. |
| 45 | M&L MCB SP 6 to 32 Amp \\"B\\" curve ,10 kA.complete all as specified and directed. |
| 46 | Supply and fix in replacement LED batten luminaire surface mounted, 4 feet system wattage of 20 Watts with lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.90, THD< 20%, colour temperature - 6500K, surge protection 3KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC, system efficacy at luminarie level > 105 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed. |
| 47 | Supply and fix in replacement 10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary - is >100lm/W with a life class of 50,000 burning hours at L70 criteria, Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%,THD<20%, CRI>80, Color Temperature-6500K, Surge protection of 4.0 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed. |
| 48 | S & F in replacement pressure die cast aluminium housing LED street light luminaires with IP66 deg. of protection suitable for 60 watt LED fitting duly fixed on 40 mm dia GI mast including 50X 6 mm thick MS flat with suitable size of fastner including making connection flexible copper conductor cable from ceiling rose to fitting complete all as specified and directed. Note : The Contractor quoated the rates incl all accessories like suitable GI pipe mast, 50x6 mm thick MS flat, fashner, nut & bolts, suitable length of flexiable wire.complete all as specified and directed. |
| 49 | Supply and fixing new BLDC fan against old ceiling fans three blade, Robust and reliable inverter motor (brush less DC Motor) powered by ECM technology, BEE 5 star rating for energy saving, rated Air delivery >220 cum/min, AC single phase 230/240 V of size 1200 mm sweep including making connection with three core flexible, copper cable pvc insulated of suitable length, complete all as directed. Note BLDC Fan should work on existing electronic fan regulator. |
| 50 | Provn of fresh air fan PVC body air delivery > 800 CMH , 5 number of blades, AC single phase 230/240 V of size 250 mm sweep with louvre fixed complete with suitable size ply by cutting into suitable size as required complete all as specified and directed by Engr-in-Charge. |
| 51 | Provn of modular box type metal enclosure single pole and Neutral with a two pin earth plug and socket complete with a MCB SP 20 Amp 220 volts, 50 Hz, 10KA breaking capacity, including fixing completly in wall with sutable sand and cement, complete all as specified and directed. |
| 52 | Provn of COB accent lighting picture light with adjustable head, Dimensions (mm) 500x180x95. Luminaire should have Aluminium housing with Chrome / Silver finish. The luminaire should have CRI > 80 and CCT of 3000K. The luminaire shall be compliant with IP20 classification.The fixture should have a minimum system lumen output of 4200 lumens and maximum system wattage of 12 Watts. The LED shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours @ design ambient temp 45 deg C. (PHILIPS : 31440 / 31441 Mirror Light OR APPROVED EQUIVALENT IN TRILUX & ENDO) |
| 53 | Provn of Wall mounting air circulator fans AC single phase 230/240 V, 1440 RPM of size 600 mm sweep (24\\") ,180 watt, Aluminium alloy three blade,Double ball-bearing 90° oscillation,Sturdy close-mesh guard beatifull design,Powerful heavy-duty motor,air dilivery 270 M³/Min, mounting on wall complete all as specified and directed by Engr-in-Charge. . |
| 54 | Provn of high efficiency IP65 round LED high-bay luminaire 100 W with high lumen efficacy of more than 110lm/W with aluminium die cast housing suited for sheds including all connection upto ceiling rose alongwith metallic chain not less than 3 m for hanging the highbay light complete all as specified and as directed. |
| 55 | S & F in repair of 100 W High efficient LED Flood light fitting with pressure die cast LM6 Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie is 100lm/W with a life class of 25,000 burning hours at L70. The color temperature is around 6500 K with a color rendering index of 70 complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 02, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 23, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysNov 25, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 17 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender