Defence Statutory Bodies & Commissions/Committees Closing in 15 days TDR #58331828

Tender For Provision Of Solid Waste Management Plant At Bb Cantt Under Ge 864 Ews (Design And Build)

Issued by Statutory Bodies & Commissions/Committees · Srinagar, Jammu and Kashmir
Tender Value
7.17 Crore
Estimated cost
Bid Submission
07 Dec 2026
15 days left
EMD
6.83 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Srinagar → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provision Of Solid Waste Management Plant At Bb Cantt Under Ge 864 Ews (Design And Build)

BOQ

Name of Work:- PROVISION OF SOLID WASTE MANAGEMENT PLANT AT BB CANTT UNDER GE 864 EWS (DESIGN AND BUILD)
Sl. No. Item Description
1Note: (i) Please refer Schedule 'A' Notes given in tender documents.(ii) The Schedule 'A' Part-VIII to X is not estimated by MES and the estimated rate indicated as \\"Rs. 0.00\\" under Col. 5 signifies this fact only.
2LUMPSUM/ OTHER PRE-PRICED PROVISIONAL SCHEDULES OF WORKS
3Lump sum price worked out by the contractor for BUILDING WORKS carried forward from Pre-Priced Schedule 'A' Part-I.
4Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY WORKS carried forward from Pre-Priced Schedule 'A' Part-II.
5Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKS carried forward from Pre-Priced Schedule 'A' Part-III.
6Lump sum price worked out by the contractor for PROTECTIVE WORKS carried forward from Pre-Priced Schedule 'A' Part-IV.
7Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY WORKS carried forward from Pre-Priced Schedule 'A' Part-V.
8Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION WORKS carried forward from Pre-Priced Schedule 'A' Part-VI.
9Lump sum price worked out by the contractor for SITE CLEARANCE & EARTHWORKS carried forward from Pre-Priced Schedule 'A' Part-VII.
10MISCELLANEOUS ITEMS OF WORKS (SCHEDULE 'A' PART-VIII)(A) INTERNAL ELECTRIFICATION WORKS
11Supply and fixing of highbay LED lights of capacity 70 watt ,IP65 energy saving, environment friendly & robust IP65 protected LED midbay with PDC housing suitable for ceiling (Surface/Suspended) mount & available in Wide beam optics. System efficacy 125 lm/W to 130 lm/W complete all as specified and directed
12Supply and fixing of sheet metal enclosure box duly powder coated & framing work with locking system and having double door fixing arrengment system suitable of size/type for vertical type distribution board vertical loadline type of rating VTPN 4 way type 415 volt 3 phase AC supply holding system with IP protection rating with ISI marked and having fitted neutral and earth link bus bar and mounting base chanels and blanking plates suitable for holding of main MCCB as incommer and out going MCB complete system alongwith providing and mounting in side of DB box of 01 No of MCCB TP 40 Amps with breaking rupting capacity 16 KA and having adjustable setting type and also providing of 04 Nos of MCB SP 63 Amps 10KA 'C' curve type of the same manufacture make as per of distribution board make complete set and including dully fixed surface on wall or concealed in wall and making all necessary electrical connection complete all as specified and directed by EIC.
13Supply & fixing of ventilating exhaust fan made out of complete sturdy engineering Metal body with having motor ,frame louvers & shutter and blade suitable for of size 600 mm 230 Volts , 900 RMP r/min including making of suitable type /size of hole on wall etc compete all as specified and directed.
14(B) EXTERNAL ELECTRIFICATION WORKS
15Supply, install, testing and commissioning copper wound step down transformer ,Outdoor type complete with standard fittings, HT, 11 KV, 3 Phase, LT , 433 Volts, 3 phase 4 wire with off load tapings on Primary side to vary secondary voltage + 7.5% with tapings at every 2.5% rating of capacity 400 KVA including bushing on HT side and LT side all as per IS 1180 and suitable size of PCC platform complete all as specified and directed.
16The Transformer shall be IS : 1180 (Part-I) : 2014 with maximum total loses as per energy efficiency level 2 of IS : 1180 (Part-I) : 2014 and shall comprise of the following: - (a) HT cable box on primary side(HV) including Three Nos of porcelain bushing with copper rods, complete all accessories as required. (b) One cable box on LV side (Secondary side) consisting of four Nos porcelain bushing with copper rods, complete with nuts and washers, with cable glands suitable for XLPE insulated heavy duty armoured cables and jointing materials complete. (c) Oil conservator with filter type drain valve and oil level gauge. (d) De-hydrating breather with first fill dehydrating agent (silica gel). (e) Explosive vent. (f) Thermometer pocket on tank cover (g) One No 100mm dia, dial type thermometer, vapour pressure type, having range 0-120 degree Celsius with metal guard having maximum perimeter reading temperature indicator with resisting device for transformer.
17(h) Two Nos earth terminals for body earthing and two No. earthing terminals for neutral earthing. (j) Rating plate and terminal marking plate. (k) Oil level gauge (l) Oil drain filter valve (m) Lifting lugs. (n) Initial filling to transformer oil with required capacity. Note :- 1. Pre-commissioning test shall be carried out by the SEI/Rep of Accepting Officer for which all arrangements shall be made by the contractor without any extra cost 2.Contractor will submit specification from approved manufacturer comprising of the above specification to Engr in Charge and take approval before placing order 3. Certificate of di electric strength shall be submitted by contractor
18M & L for bracket made out of GI tubing 40 mm dia,light grade 1.5 mtr long including fixing with MS clamps -2 Nos made out of 40 mm wide 4 mm thick flat iron with M.S nuts bolts 75 mm long 12 mm dia -4 Nos with flat washer (3mm thick) -02 No for each including painting with aluminium paint over one coat of red oxide to the M.S clamps & bracket etc complete all as specified and directed.
19Supply & fixing of Thermo plastic street light sintex box of size 280 X 170 X 120 mm fixed on pole with the help of MS nuts bolts and MS clamps-1 Nos of size 40 mm X 4 mm thick with one No MCB SP 6 Amp capacity mounted on din rail inside box all as specified and directed
20Supplying and fixing of flexible type round PVC bedded with PVC insulated and sheathed with multi FRLS cable of 1100 volt grade with multistranded copper conductor wire of size 1.5 Sq.mm 3 core type (Nominal area) ISI Marked complete,all as specified and as directed by Engr-in-Charge .
21S & F of Automatic street light switch using NATURE SWITCH for automatic switching of street Lights based on LUX level of Natural Light. The sensor (Nature Switch) along with suitable Power Contactor, MCB and Support Terminals should be enclosed in pole/ wall mountable enclosure made of Rust Proof, Electric Shock Proof, Termite proof and FR grade special moulding compound (Sintex make SMC Junction box) conforming to IP54 degree of ingress. The contactor, MCB and Circuit wiring should suitable enough to take load of 1 KW MCB (single-pole) Rating :32 Amps 3 Nos. Make : Nature Switch : Kakatiya Energy Systems Pvt Ltd Hyderabad or Equivalent of Bajaj /L&T/Legrand
22Supply, Installation, testing and commissioning of Automatic Power Factor Correction (APFC) panel,of capacity 175 KVAR indoor type floor mounted free standing totally enclosed, extendable, IP 42, of following capacity for 3 phase, 415 V + 10 %, 50 Hz AC System for Ambient temperature -5°C to +40°C, fabricated in compartmentalised designed made of CRCA sheet steel of 2.0mm thick for framework & covers, 3 mm thick for gland plate i/c cleaning & finishing complete with 9 tank process for powder coated of approved shader as approved by Engineer-in-Charge), having front section (switch gear and control accessories) and rear section capacitor and reactor, front and rear access, having suitable current carrying capacity, extensible TPN Aluminium alloy bus bar of high conductivity, DMC/SMC bus bar supports, bottom base channel of MS Section, fabrication shall be done in transportable section, entire panel shall have common copper earth bar of minimum size of 25mm x 5mm with 2 nos. earth studs, the earth terminals provided on the body of capacitor bank shall also be bonded to the main capacitor panel earth bus with 2 nos. 8 SWG or 6 SWG GI earth wires/ equivalent size of copper conductor cable, forced ventilation for maintaining temperature rise not more than 5°C from ambient, interconnections, connections with 14% detuned reactor and heavy duty 525 V ISI marked Impregnated MPP(Metalized Polypropylene) Capacitor (IS 13340 Part -1 & 2) APFC Panel shall be in compliance with IS :16636 including suitable size of PCC and Specifications etc. as per below details :-
23(A) Incomers(i) Suitable capacity MCCB Microprocessor base with O/C, S/C, E/L release of TPN 500 Amp 50KA breaking -01 Nos(ii) Extended rotary handle and door interlocking arrangement. -01 Nos (III) Spreader Link -01 Nos (iv) Auxilary contact -01 Nos (v) Trip contact -01 Nos (vi) APFC Relay 16 stage-01 Nos (vii) Digital multifunction meter-01 Nos (viii) CT 500/5A -06 Nos (ix) On delay Timer- 01 Nos (x) AM selector switch-01 Nos (xi) Auxilary contact -01 Nos (xii) R Y B indicator Lamp -02 Nos (xii) Indication lamp ON/OFF/TRIP -03 Nos (xiv) 6 A SP MCB ,10 KA -06 Nos (xv) Fan+Filter -0 Nos (B) OUTGOING FOR 50 KVAR-02 NOS(i) 125 A TP MCCB 25 KA-02 Nos (ii) Spreader Link -02 Nos (iii) 50 KVAR Capacity Duty contator-02 Nos (iv) Capacitor 50 KVAR-02 Nos (v) Reactor 14%AI-02 Nos (vi) Push button Start/Stop-04 Nos (vii) Indication lamp ON/OFF-04 Nos (viii) A/M Selector switch-02 Nos
24(C) OUTGOING FOR 25 KVAR-02 NOS (i) 63 A TP MCCB 25 KA-02 Nos (ii) Spreader Link -02 Nos (iii) 25 KVAR Capacity Duty contator-02 Nos (iv) Capacitor 25 KVAR-02 Nos (v) Reactor 14%AI-02 Nos (vi) Push button Start/Stop-04 Nos (vii) Indication lamp ON/OFF-04 Nos (viii) A/M Selector switch-02 Nos
25(D) OUTGOING FOR 10 KVAR-01 NOS (i) 25 A TP MCB -01 Nos (ii) 10 KVAR Capacitor duty contactor-01 Nos (iii) Capacitor-01 Nos (v) Reactor 14%AI-02 Nos (vi) Push button Start/Stop-04 Nos (vii) Indication lamp ON/OFF-04 Nos (viii) A/M Selector switch-02 Nos (E) OUTGOING FOR 5 KVAR-01 NOS (i) 16 A TP MCB -01 Nos (ii) 5 KVAR Capacitor duty contactor-01 Nos (iii) Capacitor-01 Nos (v) Reactor 14%AI-02 Nos (vi) Push button Start/Stop-02 Nos (vii) Indication lamp ON/OFF-02 Nos (viii) A/M Selector switch-02 Nos(F) OUTGOING FOR 3 KVAR-01 NOS (i) 10 A TP MCB -01 Nos (ii) 3 KVAR Capacitor duty contactor-01 Nos (iii) Capacitor-01 Nos (v) Reactor 14%AI-02 Nos (vi) Push button Start/Stop-02 Nos (vii) Indication lamp ON/OFF-02 Nos (viii) A/M Selector switch-02 Nos
26(G) OUTGOING FOR 2 KVAR-01 NOS (i) 10 A TP MCB -01 Nos (ii) 2 KVAR Capacitor duty contactor-01 Nos (iii) Capacitor-01 Nos (v) Reactor 14%AI-02 Nos (vi) Push button Start/Stop-02 Nos (vii) Indication lamp ON/OFF-02 Nos (viii) A/M Selector switch-02 Nos (H) OUTGOING FOR 1 KVAR-01 NOS (i) 10 A TP MCB -01 Nos (ii) 1 KVAR Capacitor duty contactor-01 Nos (iii) Capacitor-01 Nos (v) Reactor 14%AI-02 Nos (vi) Push button Start/Stop-02 Nos (vii) Indication lamp ON/OFF-02 Nos (viii) A/M Selector switch-02 Nos
27NOTE: (i) If Any other accesories /part which is required to make fully functional to the complete capacitor panel will as per manufacturer instructions and shall be measrured in qutoed rate. (ii) Contractor will submit specification from approved manufacturer comprising of the above specification to Engr in Charge and take approval before placing order.
28Supply, fixing ,installation, testing and commissioning of new LT distribution panel board out door based type suitable using for 3 phase 4 wire 415 volt 50 HZ AC supply system with cubical shape factory fabricated and assembled with made out of CRCA mild steel sheet of 3.15 mm thick with epoxy powder coated painted and with having CPRI approved including making it totally enclosed weather, dust & vermin proof with having double door system and dully fabricated on MS based chanel fram work alog with cutting, drilling ,bending and welding hot & cold with hinges,clamp, nut & bolt etc and including making necessary louvers, gasket ,air vent and both front and rear side door opening and locking system and including consisting of nos of required incoming/outgoing feeder compartments with mounting channel along with providing of main three phase & neutral copper bus bar of current rating capacity 1000 Amp and duly cover with PVC colour heat shrinkable sleeve as per phase sequence system and duly fixed on insulator complete along with suitable current rating capacity of copper sub distribution bus bar of three phase paneling system for fixing of inter connection of incomming/out going feeder based on the load and duly attached it with main bus bar system and including cover with PVC colour heat sinkable sleeve as per the phase sequence including providing of digital type volt meter and amp meter of maximum range based on panel design load alongwith indication RYB lamp and suitable type CT with ratio of three phase system and also providing of internal control wiring for display & metering eqpt system with multi stranded copper wire complete and including also providing and comprising along with the following mentioned nos of incoming and out going controlling and operating fitted fixture with fitting accessories, cable grand and earth terminal point and including all the items are dully fixed on inside area of panel board system and providing of danger notice board on both side outer body area of LT panel board complete system work . The panel board should be fitted/mounted on angle iron bottom base frame system of size 40x40x5 mm and 75 cm height including grouted in PCC plate form work with all fixing accessories complete all as specified and directed by EIC
29Incoming -(a) MCCB of rating capacity 630 Amps 4 pole 50 KA 415 volt with having adjustable thermal setting type complete - 01 No Out going - (b) MCCB of rating capacity 500 Amps 4 pole 50 KA 415 volt with having adjustable thermal setting type complete- 01 No (out going I/D panel-1)(c) MCCB of rating capacity 160 Amps 4 pole 36 KA 415 volt with having adjustable thermal setting type complete - 03 Nos (out going I/D panel-2 and 01 Nos Spare) (d) MCCB of rating capacity 40 Amps 4 pole 25 KA 415 volt with having adjustable thermal setting type complete- 02 No(e)MCB SPN 63 Amp ,220 V ,10 KA-02 Nos(f) Digital type voltmeer 0-500 volts.-01 No(g) Digital type Ammeter -01 No(h Indicating LED lamps R,Y& B -01 set
30Supply, instalation, testing & commissioning of LT panel factory made indoor type, dust & Vermin proof self-supporting fabricated out of CRCA steel sheet 1.6mm in inner compartment of suitable size with 450 mm depth with base and Angle Iron frame (50x50x5mm) support to mount panel and tightened with 06 Nos 30 mm x 15 mm bolts & nuts with 4 Legs 30 cms below & 30 cms above GL grouted in PCC 1:3:6 Type C2 , cubicle type floor mounting, suitable for 3 phase 4 wire, 415 V, 50 Hz, AC supply,with providing of main three phase & neutral copper bus bar of current rating capacity 800 Amp and duly cover with PVC colour heat shrinkable sleeve as per phase sequence system and duly fixed on insulator complete having cable ally on both sides of panel independent bays for incoming & outgoings with openable from front, rear, left & right side with locking arrangements . Duly painted with powder coating (10 tank process) and PU gasket. Cable lugs are to be used to terminate cables/wires. Single core copper cables shall be used for connections from bus bar to MCCBs/MCBs/ instuments etc.
31Incoming - (a) MCCB of rating capacity 500 Amps 4 pole 50 KA 415 volt with having adjustable thermal setting type complete - 01 No Out going - (b) MCCB of rating capacity 100 Amps 4 pole 25 KA 415 volt with having adjustable thermal setting type complete- 06 No(c) MCB TPN, 415 V of rating capacity 32 Amps - 01 Nos (d) Digital type voltmeer 0-500 volts.-01 No(e) Digital type Ammeter -01 No(f) Indicating LED lamps R,Y& B -01 set
32Supply, install, test & commission LT panel factory made indoor type, dust & Vermin proof self-supporting fabricated out of CRCA steel sheet 1.6mm in inner compartment of suitable size with 450 mm depth with base and Angle Iron frame (50x50x5mm) support to mount panel and tightened with 06 Nos 30 mm x 15 mm bolts & nuts with 4 Legs 30 cms below & 30 cms above GL grouted in PCC 1:3:6 Type C2 , cubicle type floor mounting, suitable for 3 phase 4 wire, 415 V, 50 Hz, AC supply,with providing of main three phase & neutral copper bus bar of current rating capacity 300 Amp and duly cover with PVC colour heat shrinkable sleeve as per phase sequence system and duly fixed on insulator complete having cable ally on both sides of panel independent bays for incoming & outgoings with openable from front, rear, left & right side with locking arrangements . Duly painted with powder coating (10 tank process) and PU gasket. Cable lugs are to be used to terminate cables/wires. Single core copper cables shall be used for connections from bus bar to MCCBs/MCBs/ instuments etc. Please Enable Macros to View BoQ information
33Supply, install, test & commission LT panel factory made indoor type, dust & Vermin proof self-supporting fabricated out of CRCA steel sheet 1.6mm in inner compartment of suitable size with 450 mm depth with base and Angle Iron frame (50x50x5mm) support to mount panel and tightened with 06 Nos 30 mm x 15 mm bolts & nuts with 4 Legs 30 cms below & 30 cms above GL grouted in PCC 1:3:6 Type C2 , cubicle type floor mounting, suitable for 3 phase 4 wire, 415 V, 50 Hz, AC supply,with providing of main three phase & neutral copper bus bar of current rating capacity 300 Amp and duly cover with PVC colour heat shrinkable sleeve as per phase sequence system and duly fixed on insulator complete having cable ally on both sides of panel independent bays for incoming & outgoings with openable from front, rear, left & right side with locking arrangements . Duly painted with powder coating (10 tank process) and PU gasket. Cable lugs are to be used to terminate cables/wires. Single core copper cables shall be used for connections from bus bar to MCCBs/MCBs/ instuments etc. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58331828
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 7.17 Crore
LAST DATE 07-12-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provision Of Solid Waste Management Plant At Bb Cantt Under Ge 864 Ews (Design And Build)
Basic Detail
Tender No 800227
Bidding Type Tender
Location
City Srinagar
State Jammu and Kashmir
Key Dates
Publish Date 02 Nov 2026
Submission Date 07 Dec 2026
Open Date 09 Dec 2026
Finance
Tender Value 7.17 Crore
Tender Fee 3000
EMD 6.83 Lakhs
Exemption Available
Document List
346c360a-f730-4181-a517-bfea18fed103.html
BOQ_893895.xls
Drgs.pdf
Tendernotice_1.pdf
TenderSolidWasteMerged.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 02, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 15 days
Dec 09, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 17 days

Tender Documents

Download All (ZIP) ↓
html

346c360a-f730-4181-a517-bfea18fed103.html

xls

BOQ_893895.xls

pdf

Drgs.pdf

pdf

Tendernotice_1.pdf

pdf

TenderSolidWasteMerged.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender