Tender For Repair/ Maintenance Of Internal Electric Wiring And Cooling/ Heating Appliances At annual rate contract Sarsawa Under Ge (Af) Sarsawa
Tender Value
30 Lakhs
Estimated cost
Bid Submission
23 Nov 2026
2 days left
EMD
60000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Saharanpur → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/ Maintenance Of Internal Electric Wiring And Cooling/ Heating Appliances At annual rate contract Sarsawa Under Ge (Af) Sarsawa
BOQ
| Sl. No. | Item Description |
| 1 | Taking down carefully copper / aluminium point wiring light / fan, socket or power point complete including fittings such as switches, sockets, ceiling rose, bell push bell buzzer lamp holder bracket etc. removing from site and making good disturbed surface of wall, floor etc complete all as specified and as directed. |
| 2 | M & L for replacement of concealed point wiring complete with PVC insulated and unsheathed FRLS cable of 1.5 sqmm (nominal area) with multi stranded copper conductor single core 1100 volts grade in and including rigid PVC conduit ISI marked medium grade not less than 20 mm dia, with MS stove enamelled sunken boxes (normal and modular type as required) including earth dolly with plastic laminated sheet top cover (cover plate with frame in case of modular) of approved make and colour including 1.5 sqmm multi stranded FRLS copper conductor cable of green colour as continuous earth wire with lugs and accesseries and making good disturbed surfaces of walls/floor etc complete all as specified and directed for the followings :-One light / fan point controlled by one way switch |
| 3 | All as per Item No 2 above but for One 5 Amp socket outlet on independent board. |
| 4 | All as per Item No 2 above but for One 5 Amp socket outlet on same board. |
| 5 | All as per Item No 2 above but for One bell/buzzer point controlled by one bell push. |
| 6 | All as per Item No 2 above but for One light point controlled by two 2-way switch. |
| 7 | All as per above item No-2 here in before but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed, FRLS cable for 15 Amp socket outlet on independent board including 2.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs etc as required complete all as specified and as directed. |
| 8 | M&L for replacement of point wiring in casing caping on sufraces of wall/ceiling floor etc complete with PVC insulated and unsheathed FRLS cable of 1.5 sqmm (nominal area) with multi stranded copper conductor single core 1100 volts grade with PVC rectangular block of suitable size including 1.5 sqmm multi stranded FRLS copper conductor cable of green colour as continuous earth wire with lugs and accesseries and making good disturbed surfaces of walls/floor etc complete all as specified and as directed for the followings :-One light / fan point controlled by one way switch |
| 9 | All as per Item No 8 above but One 5 Amps socket out let point controlled by one 1-way switch on independent board. |
| 10 | All as per Item No 8 above but One 5 Amps socket out let point controlled by one 1-way switch on same board. |
| 11 | All as per Item No 8 above but One bell/buzzer point controlled by one bell push |
| 12 | All as per Item No 8 above but One light point controlled by two 2-way switch |
| 13 | All as per above item no 8 here in befor but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed, FRLS cable for 15 Amp socket outlet on independent board including 2.5 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs etc as required complete all as specified and as directed. |
| 14 | M & L for replacement of existing conduit point wiring complete with PVC insulated and unsheathed FRLS cable of 1.5 sqmm (nominal area) with multi stranded copper conductor single core 1100 volts grade drawn through existing conduitwith MS stove enamelled sunken boxes (normal and modular type as required) including earth dolly with plastic laminated sheet top cover ( cover plate with frame in case of modular) of approved make and colour including 1.5 sqmm multi stranded FRLS copper conductor cable of green colour as continuous earth wire with lugs and accesseries and making good disturbed surfaces of walls/floor etc complete all as specified and directed for the followings :-One light / fan point controlled by one switch. |
| 15 | All as per Item No 14 above but One bell point controlled by one bell Push |
| 16 | All as per Item No 14 above but One 5 Amps socket out let point controlled by one switch on independent board. |
| 17 | All as per Item No 14 above but One 5 Amps socket out let point controlled by one switch on same board. |
| 18 | All as per Item No 14 above but with 2.5 Sqmm nominal cross sectional area electric cable for 15 Amps socket outlet point controlled by one switch on independent board complete. |
| 19 | S&F in replacement switch piano type 5 amp one way ISI Marked complete all as specified and directed by Engineer-in-Charge. |
| 20 | S&F in replacement switch piano type15 Amps one way ISI Marked complete all as specified and directed by Engineer-in-Charge. |
| 21 | S&F in replacement socket outlet 5 pin 5 Amps flush type complete all as specified and directed by Engineer-in-Charge. |
| 22 | S&F in replacement socket outlet 2-in-1, 6 pin 5 amp and 15 amps all as specified and directed. |
| 23 | S&F in replacement socket outlet 6A-2/3 Pin combined 2 module modular type complete all as specified and directed. |
| 24 | S&F in replacement socket outlet 6A/16A-2/3 pin combined 2 module modular type complete all as specified and directed. |
| 25 | S&F in replacement switch 6 amps modular type one one way complete all as directed. |
| 26 | S&F in replacement switch 16 amps modular type one one way complete all as directed. |
| 27 | S&F in replacement electronic fan regulator Step type complete all as specified and directed. |
| 28 | S&F in replacement bell push flush type 5 amp one way ISI Marked complete all as specified and directed. |
| 29 | S&F in replacement modular type bell push 6 amp one module ISI Marked complete all as specified and directed. |
| 30 | S&F in replacement Bell, DING DONG AC 230 Volts single pole type complete all as specified and as directed. |
| 31 | S & F in replacement of Lamp holder bakalite type with back plate suitable for batten fittings complete all as specified as directed |
| 32 | S&F in replacement of ceiling rose surface bakelite 63 x50mm three terminals complete all as specified and as directed. |
| 33 | S & F in replacement of sub main wiring with PVC insulated, FRLS unsheathed two single core cable 1100 volts grade with stranded copper conductor of size 4.0 sqmm (Nominal area) drawn in and including PVC conduit of suitable size as directed with and including one run of 4.0 sqmm multi stranded copper conductor single core PVC insulated, unsheathed cable of green colour as continuous earth wire including lugs etc connected and tested complete all as specified and as directed.Note: (i) Two runs of 4.0 sqmm cable and one run of 4.0 sqmm cable of earth continuity conductor and conduit shall be a unit length. |
| 34 | S & F in replacement of sub main wiring with PVC insulated, FRLS, unsheathed two single core cable 1100 volts grade with stranded copper conductor of size 6.0 sqmm (Nominal area) drawn in and including PVC conduit of suitable size as directed with and including one run of 6.0 sqmm multi stranded copper conductor single core PVC insulated, unsheathed cable of green colour as continuous earth wire including lugs etc connected and tested complete all as specified and as directed.Note: (i) Two runs of 6.0 sqmm cable and one run of 6.0 sqmm cable of earth continuity conductor and conduit shall be a unit length. Please Enable Macros to View BoQ information |
| 35 | S & F in replacement of sub main wiring with PVC insulated, FRLS, unsheathed two single core cable 1100 volts grade with stranded copper conductor of size 6.0 sqmm (Nominal area) drawn in and including PVC conduit of suitable size as directed with and including one run of 6.0 sqmm multi stranded copper conductor single core PVC insulated, unsheathed cable of green colour as continuous earth wire including lugs etc connected and tested complete all as specified and as directed.Note: (i) Two runs of 6.0 sqmm cable and one run of 6.0 sqmm cable of earth continuity conductor and conduit shall be a unit length. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 02, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 23, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysNov 30, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender