Tender For Special Repairs To Lt Ug Cable Inside College Area And Connected Works Under Age E/M, Provision Of Industrial Water Heating System For Warming Of Drinking Water To Army Houses In Stable No 2 Of Equitation Sec, Provision Of Partition At 1St
Tender Overview
Project Description
Tender for Special Repairs To Lt Ug Cable Inside College Area And Connected Works Under Age E/M, Provision Of Industrial Water Heating System For Warming Of Drinking Water To Army Houses In Stable No 2 Of Equitation Sec, Provision Of Partition At 1St Floor Varandah At Carnatic Lines And Allied Works, Provision Of Partition At B Series And Allied Work, Provision Of Facade Lights And Allied Works At Dssc Main Gate At Dssc Wellington
BOQ
| Sl. No. | Item Description |
| 1 | Taking down old unserviceable LT UG cable of size 25 Sqmm to 240 Sqmm complete all as specified and as directed |
| 2 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for taking out/laying of UG Cables, GI Pipe etc. and getting out in hard dense soil complete all as specified and directed . |
| 3 | Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick with excavated soil complete all as specified and directed. |
| 4 | Removing of excavated material (Soil) to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point all as speciofied and directed. |
| 5 | M&L for providing sand cushioning for protection of UG cable in trenches with coarse Riddled soil Earth of including filling, spreading and punning down to desired thickness complete and all as specified and directed. |
| 6 | Supply and laying well burnt old size sub class 'B' bricks of size 230mm x 115mm x 75mm bricks in trenches for cable protection of U/G cables above sand cushioning complete all as specified and directed. |
| 7 | M&L for cutting the existing hard standing/PCC/WBM road at a depth not less than 45 cm and 25 cm in width for passing of cable through GI pipe, returning filling in, complete including finishing the surfaces by providing cement concrete (1:2:4) type B2 (using 40mm grade stone aggregate) upto 20 cm depth, finishing to a uniform smooth surface to match the existing surface complete all as specified and directed.Note : GI pipes shall be measured and paid separately. |
| 8 | Supply and laying GI pipe light grade (ISI Marked) of size 100 mm for cable protection to be fixed on wall /pole /road crossing with necessary clamps complete all as specified and directed. |
| 9 | Supply and laying GI pipe light grade (ISI Marked) of size 80 mm for cable protection to be fixed on wall /pole /road crossing with necessary clamps complete all as specified and directed. |
| 10 | Supply and laying GI pipe light grade (ISI Marked) of size 50 mm for cable protection to be fixed on wall /pole /road crossing with necessary clamps complete all as specified and directed. |
| 11 | Supply, laying, jointing & testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 300 Sqmm 3.5 core complete all as specified and as directed. |
| 12 | (a) All as per Item No 11, but sec. area 240 Sqmm 3.5 core. |
| 13 | (b) All as per Item No 11, but sec. area 185 Sqmm 3.5 core. |
| 14 | (c) All as per Item No 11, but sec. area 120 Sqmm 3.5 core. |
| 15 | (d) All as per Item No 11, but sec. area 95 Sqmm 3.5 core. |
| 16 | (e) All as per Item No 11, but sec. area 70 Sqmm 3.5 core. |
| 17 | (f) All as per Item No 11, but sec. area 50 Sqmm 3.5 core. |
| 18 | (g) All as per Item No 11, but sec. area 35 Sqmm 3.5 core. |
| 19 | (h) All as per Item No 11, but sec area 25 Sqmm 4 Core |
| 20 | M & L in repairs MCCB, 4 pole,315 A rating , 415Volts,36 kA , adjustable thermal magnetic setting , Ics =100% Icu Class II Front face suitable for isolation , adjustable overload setting Ir=(0.8 to 1.0 )xln , short circuit setting fixed , conforms to IEC= 60947- II, and making cut in existing panel for fixing of MCCB as per site requirement and complete all as specified and directed . |
| 21 | M & L in repairs MCCB, 4 pole,160 A rating , 415Volts,16kA , adjustable thermal magnetic setting , Ics =100% Icu Class II Front face suitable for isolation , adjustable overload setting Ir=(0.8 to 1.0 )xln , short circuit setting fixed , conforms to IEC= 60947- II, and making cut in existing panel for fixing of MCCB as per site requirement and complete all as specified and directed . |
| 22 | M & L in repairs MCCB, 4 pole,125 A rating , 415Volts,16kA , adjustable thermal magnetic setting , Ics =100% Icu Class II Front face suitable for isolation , adjustable overload setting Ir=(0.8 to 1.0 )xln , short circuit setting fixed , conforms to IEC= 60947- II, and making cut in existing panel for fixing of MCCB as per site requirement and complete all as specified and directed . |
| 23 | M & L in repairs MCCB, 4 pole,100 A rating , 415Volts,16kA , adjustable thermal magnetic setting , Ics =100% Icu Class II Front face suitable for isolation , adjustable overload setting Ir=(0.8 to 1.0 )xln , short circuit setting fixed , conforms to IEC= 60947- II, and making cut in existing panel for fixing of MCCB as per site requirement and complete all as specified and directed . |
| 24 | M & L in repairs MCCB, 4 pole,63 A rating , 415Volts,16kA , adjustable thermal magnetic setting , Ics =100% Icu Class II Front face suitable for isolation , adjustable overload setting Ir=(0.8 to 1.0 )xln , short circuit setting fixed , conforms to IEC= 60947- II, and making cut in existing panel for fixing of MCCB as per site requirement and complete all as specified and directed . |
| 25 | S&F in repair on load change over switch 4 pole (I-O-II) in sheet mental enclosure modular construction type, confirming to IS/IEC 60947-3, rated current 400 A, 415 V, with supporting angle iron frame , PCC (1:3:6) type C2 foundation necessary earth work (if any) incl taking down and all as specified and directed |
| 26 | M&L for repairs straight through joint, heat shrink type for LT UG Cable incl joint kits suitable for Aluminium conductor cable of size 50 Sqmm 4/3.5 core incl earthwork, taking down, preparation of damaged cable incl testing complete all as specified & as directed by the Engr-In-Charge. |
| 27 | (a) All as per Item No 18, but cable of size 95 Sqmm 3.5 core. |
| 28 | (b) All as per Item No 18, but cable of size 120 Sqmm 3.5 core. |
| 29 | (c) All as per Item No 18, but cable of size 185 Sqmm 3.5 core. |
| 30 | Supply Install Testing and commissioning Industrial Water Heating System of heat pump storage Tank with heating Capacity 5.8 KW ,Production Capacity 125 Ltr pwer Hour of 3.4 KW max power input of rated max current 11 Amps of 220 V -240 V Single Phase max water temperature 60 Degree, heat Pump Dimension is 838 X 718 X 1832 mm ,Weight 36 KG at a noise level of < 57 DB ,water Inlet or outlet size 2.54 (01 Inch) and thickness of tank insulation 50 mm and inner tank with heavy duty magnesium anode rod , and ultra -thick , cold rolled steel tank for correction resistance and high pressure apllication complete all as directed by Engr in Charge.Hot water outlet connection from water heater to Existing system of suitable size CPVC hot water pipe and connected running items ,02 nos of CPVC valves including fixing charges etc are included in the rate quoted by the contractor. Make: Havells, model No HP 50 heat pump water Heater 500 L / V Guard Model no:V-HP 500 or equivalent Please Enable Macros to View BoQ information |
| 31 | Supply Install Testing and commissioning Industrial Water Heating System of heat pump storage Tank with heating Capacity 5.8 KW ,Production Capacity 125 Ltr pwer Hour of 3.4 KW max power input of rated max current 11 Amps of 220 V -240 V Single Phase max water temperature 60 Degree, heat Pump Dimension is 838 X 718 X 1832 mm ,Weight 36 KG at a noise level of < 57 DB ,water Inlet or outlet size 2.54 (01 Inch) and thickness of tank insulation 50 mm and inner tank with heavy duty magnesium anode rod , and ultra -thick , cold rolled steel tank for correction resistance and high pressure apllication complete all as directed by Engr in Charge.Hot water outlet connection from water heater to Existing system of suitable size CPVC hot water pipe and connected running items ,02 nos of CPVC valves including fixing charges etc are included in the rate quoted by the contractor. Make: Havells, model No HP 50 heat pump water Heater 500 L / V Guard Model no:V-HP 500 or equivalent Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 25 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender