Tender For Structural Repairs Of The Existing Jetty (Part-C) And Reconstruction Of The Old Jetty (Part D) At Dona Paula, Tiswadi, Dona Paula
Tender Overview
Project Description
Tender for Structural Repairs Of The Existing Jetty (Part-C) And Reconstruction Of The Old Jetty (Part D) At Dona Paula, Tiswadi, Dona Paula
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 12-Nov-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 16-Nov-2026 |
| 2 | 16-Nov-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 19-Nov-2026 |
| 3 | 19-Nov-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 23-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Earthwork in excavation by mechanical means over area in all types of soil/saturated soil for all depths including removing of all types debires, wooden vlogs,slug small boulders etc along with excavated earth lead upto 50m and lift upto 1.5m disposed earth to be neatly dressed and leveled including pumping or bailing out water as durected by Engineer in cahrge |
| 2 | Supplying jamba wooden bally piles 150 mm mean diameter cut to length required (not exceeding 9 meters) and planted in position ready for driving: b) Above 2.50 meters upto 3.50 meters long pile |
| 3 | Heading and pointing whole bally piles 150mm diameter including only rings, providing and fixing pile shoes, cutting of heads after driving and taking out rings removing cut off portions to departmental store as specified. |
| 4 | Driving down wooden piles of 150mm diameter either in vertical or battered work to approved lines and level through various strata including arranging all the appliances necessary for pile driving complete at site (portion in ground only to be measured) b) Above 2.50 meters upto 3.50 meters long pile |
| 5 | Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete. |
| 6 | Centering and shuttering including struttings, propping etc. and removal of formwork for : b) vertical surfaces such as retaining walls , return walls, walls (any thk) including attached pilasters, buttresses, plinth and string courses, fillets, etc. |
| 7 | Providing and laying in position ready mixed concrete (RMC) with usage of Ordinary Portland Cement manufactured in fully automatic batching plant and transported to site of work in transit mixer for a lead upto 10kms having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C., from the transit mixer to the site of laying, excluding the cost of centering, shuttering, finishing and reinforcement including the cost of admixtures in recommended porportions as per IS : 9103 to accelerate/retard setting of concrete, improve workability without imparing strength and durability as per the directions of the engineer-in-charge. All works upto floor V level VI) M-35 grade of concrete |
| 8 | Providing and casting plain cement concrete block of size 1.00 m × 1.00 m × 1.00 m in M35 grade concrete, including centering, shuttering, vibration, curing, and finishing complete. The block shall be provided with PVC weep holes of 100 mm diameter (or as specified) at vertical and horizontal sides to facilitate drainage of accumulated water and relieve hydrostatic pressure. The work includes all materials, labour, machinery, transportation, formwork, excavation (if required), and all incidental charges, complete as directed by the Engineer-in-Charge. |
| 9 | Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge. |
| 10 | Carraigeway and Disposal of unserviceable building material, Laterite stone, demolished concrete, excavated earth upto a lead of 20 kms from the site of execution by means of tipper truck including loading, unloading and dumping/stacking as directed by Engineer -in-charge. |
| 11 | Providing and laying in position design Mix Prestressed grade M40 concrete using controlled batching plant/Ready Mix concrete including designing and providing centering and shuttering etc all complete as directed by Engineer - in -charge. |
| 12 | Providing shalitax pad in expansion joints of service bridge including cutting to required size and placing in position before concreting as directed by the Engineer Incharge. The rate inclusive cost of all the materials, transport and labour involved in the work. |
| 13 | Providing and fixing in position elastomeric bearings of size 600x450x75 mm for service bridge confirming to IRC: 83 (part II)-1987 with latest amendments. The rate is inclusive of all the cost of materials, machinary, labour, transportation, glue and inclusive of all the taxes as directed by the Engineer Incharge complete. |
| 14 | Providing fixing of shear links of 12 mm dia in the periphery of the wall for 100 mm mm depth @ 500 mm c/c both way and grouting with underwater epoxy grout includes the cost of hire charges of all machineries, barge, boat, cost of all tools and all labour charges etc., complete. |
| 15 | Providing fixing of dowel rod of 16mm dia in the river bed for 400mm depth and 600mm above @ 1000mm c/c in single layer and grouting with underwater epoxy grout includes the cost of hire charges of all machineries, barge, boat, cost of all tools and all labour charges etc., complete. |
| 16 | Providing Fusion Bonded Epoxy Coated TMT steel reinforcement bars Fe-500 Grade (Confirming to IS 1786:2008 & IS 13620:1993) for RCC work including bending, binding & placing in position at all the floors along with the factory made precast concrete cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in thestructural member. |
| 17 | Centering and shuttering including struttings, propping etc. and removal of formwork for : b) vertical surfaces such as retaining walls , return walls, walls (any thk) including attached pilasters, buttresses, plinth and string courses, fillets, etc. |
| 18 | Eproxy bonding of new concrete to old concrete. |
| 19 | Protective coating -Paint with Emce Colourflex of MC Bauchemie or Equivalent with a priming coat @100 g/m2 & main polymer coating thickness 200-225 microns @400-450 g/m2 for two coats with approved shades including cost of materials,cleaning ,preparing the surface,chipping,removing loose dirt with wire brush & water ,labour for filling holes,cracks,joints etc.with one component polymer modified fine repair & cosmetic mortar,labour for applying above coating,scaffolding charges etc with all taxes complete as per IRC SP:80 Clause 6.5.1 & clause 2808 of MORT& H specifications latest edition. |
| 20 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by theEngineer : Flamed finish granite stone slab.a. Jet Black |
| 21 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by theEngineer : Flamed finish granite stone slab.c) Elite Brown |
| 22 | Providing and fixing solid Ornamental Cast Iron (Malleable Iron) railing/Grill in desired size and shape as per architecural drawing including making die for casting as per approved design. The alloy should contain Carbon not less than 2.16% by weight and Silicon not less than 0.9% by weight along with other materials suitable to withstand salt water, high humidity for better corrosion resistance with necessary fittings and fixtures. The casting should be done at temperature 816–954°C and then gradually cool down to room temperatrure so as to reduce brittleness including accesories for fitting and fixing, cutting, welding, bending where ever necessary and cleaning the joints upto all lifts excuding painting. As directed by Engineer In Charge. |
| 23 | Providing and fixing GRC (Glass Fiber Reinforced Concrete) Grill 35 mm thickness or GRC clAdding to concrete Pillars 30 mm thickness in plain finish in accordance to dimention mentioned in drawings. The material should be casted with Hand of Machine Spray method confirming Flexural Strength not less than 6 Mpa, Compressive strength not less than 35 Mpa and Imapact strength not less than 7 Kg/sqm. Glass fibre used should be manufactured by 'Saint-Globain' or equivalent and must be at the rate not less than 3/100 (by Wt). Material should be casted in 100% white cement manufactured 'JK Cement' or equivalent. Super Plasticiser used should be of 'BASF' or equivalent. UV resistant synthetic inorganic pigments should be used for pigmentation manufactured by 'BAYFERROX'(Germany) or equivalent. The material casting should be take place in Rubber/FRP mould. The erection should be 'Dry Fixing' i.e. to be done with Stainless Steel fixtures and finished with chemical grouting where ever necessary. Complete as directed by Engineer In Charge. |
| 24 | Providing and fixing GRC (Glass Fiber Reinforced Concrete) precast slab of 75 mm thickness in plain finish on RCC beam in accordance to dimention mentioned in drawings. The material should be casted with Hand of Machine Spray method confirming Flexural Strength not less than 6 Mpa, Compressive strength not less than 35 Mpa and Imapact strength not less than 7 Kg/sqm. Glass fibre used should be manufactured by 'Saint-Globain' or equivalent and must be at the rate not less than 3/100 (by Wt). Material should be casted in 100% white cement manufactured 'JK Cement' or equivalent. Super Plasticiser used should be of 'BASF' or equivalent. UV resistant synthetic inorganic pigments should be used for pigmentation manufactured by 'BAYFERROX'(Germany) or equivalent. The material casting should be take place in Rubber/FRP mould. The erection should be 'Dry Fixing' i.e. to be done with Stainless Steel fixtures and finished with chemical grouting where ever necessary. Complete as directed by Engineer In Charge. |
| 25 | Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 40 m nominal size) excluding cost of centering,shuttering and finishing :a. All works upto plinth level |
| 26 | Applying Epoxy Paint to metalic surace for effective corrosion resistance and UV protection and to retain long term durability by thorughly cleaning the surface and applying two coats of Aqua Sealer primer to receive 50 ~ 75 µm thick Epoxy coating in colour as directed by Engineer In Charge. Finished surface should be cleaned for any stains with Ethyl acetate or equivalent material. |
| 27 | Applying Lacquer coat to surfaces like GRC pillars, exposed natural rock including pressure washing to remove fungus, aging, moss infestation to convert hydrophillic surface to hydrophobic to prevent it from developing algae, paracites and making it UV resistant with 100% Reactive Organosilane Nano-Sealer like 'Zycosil' or equivalent. Material used should penetrate 2mm inside receiving surface to become matt or glossy surface as integrated part of structure. As directed by Engineer In Charge. |
| 28 | Providing and applying Artistic Texture Plaster of mixture of Dholpuri stone crystal matrial with rough and tough chemical solvent mixed using bubble spray of 1.5mm thickness (min) on new or old platered surfaces for making the finished surface waterproof and crackless in heavy rainfall area with appropriate finish and design including scafolding as approved by Engineer Incharge. |
| 29 | Colour enhancing of old/new surface to retain its original colour including removal of algea, paracite, moos infestation, any dust or cement by applying colour enhancing liquid mixed with appropriate quantiy of water followed by pressure washing using roto nozal at the rate of not less than 500psi to remove any residue completely without damaging grout or any sealer applied (repair has to be done if any grout damaged at no extra cost) as directed by Engineer Incharge. |
| 30 | Providing and fixing Exposed laterite cladding 75mm thick with Patradevi laterite stone on concrete pillars as shown in the drawings, including 12mm cement plaster on concrete surface 1:3 (1cement 3: fine sand), chamfering the edges, filling the joints with matching colour pigments, including polishing the same with non-reactive, antifungal, and water repellant Silane/ Siloxane chemical as approved by the engineer, etc complete. |
| 31 | 12mm cement plaster 1:3 (1 cement : 3 fine sand) |
| 32 | Providing and fixing working platform for demolishing of the existing dilapidated jetty namely C and D in such way to hold the demolished material on the working platfrom (in no case the demolished materials should spill in the sea). The working platform to be with materials such as ISMB, Channels , MS plates incl welding , riveting etc and the working platform should be capable of supporting the entering /shuttering and RCC slab which is to be re-constructed. The cofferdam or any such interventions in the sea /water front whatso ever , is not permitted. The rate includes transportation and fixing of materials at site from land and wate |
| 33 | Rehabilitation, repairs design of the existing jetty incl Designing of the approach slab of the jetty, Non destructive integrity test of all the piles/piers , pier caps and other elements of the exisiting jetty and rehabilitation plan of the piers , such that it is competent to carry class A loading condition and live load of 500 Kg/m2 as per codal provisions. The same design to be vetted by the reputed institutes such as IIT/NIT etc all complete and as directed by Engineer in Charge. |
| 34 | Conducting low strain pile integrity test on R.C. bored pile foundations of all required dia RCC piles using pile integrity tester equipement confirming to ASTM - 5882 as required by Engineer including submission of test reports etc. complete. |
| 35 | Electrical Work |
| 36 | Supply of 3 core unarmoured PVC/XLPE insulated, PVC sheathed copper conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size.3 core 2.5sqmm |
| 37 | Supply of 4 core armoured PVC/XLPE insulated, PVC sheathed copper conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. 4 core 10sq mm |
| 38 | Supply of 3 1/2 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. 3 1/2 Core 25 sq.mm |
| 39 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm in the existing RCC/HUME/STONEWARE Metal pipe, etc. complete as required |
| 40 | Supplying and making cable end terminations with brass compression gland and copper lugs for folowing sizes of 3 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required..3X 1.5/2.5 sqmm |
| 41 | Supplying and making cable end terminations with brass compression gland and copper lugs for folowing sizes of 4 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required.4 X 10sqmm |
| 42 | Supplying and fixing 6 A to 32 A, C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required.a) SP Cat A |
| 43 | Supply and Installation of 3 meter height pole made of hot dipped galvanised (60 micron minimum) for effective corrosion resistance, mild steel material, Primered and PU painted factory Finished. The column must have a hinged flush door at the bottom with proper strengthening to the cutout of the door opening. A junction/ looping box with 32 Amps heavy duty connector shall be built in to the pole and with provision of SP MCB, provided with a base plate and one set (4 Nos.) of SS J-bolts, and suitable for mounting of IP65 LED luminaire 40-45 Watts with die cast aluminium housing of IK 08.of Neri, Crompton, Bajaj Make or equivalent make subjected to approval of sample by engineer in charge Exclusive of MCB and 3c 2.5 sq mm wire from MCB to Fitting |
| 44 | Supply ,Installation Testing , Commissioning 40-50 W light fixture of IP65, 4730 System Lumens, 4000k LED including constant current driver with short circuit and overvltage protection and surge protection upto 4KV, of Neri or Bajaj or crompton or phhylips Make or equivalent make subjected to approval of sample by engineer in charge and with other required accesories. Exclusive of MCB and 3c 2.5 sq mm wire from MCB to Fitting |
| 45 | Supplying, of HDPE pipes at store or site of work including loading & unloading stacking, transit insurance etc. Complete bearing ISI mark conforming to IS: 14333 - 1996 and made from PE 100 resin Class IV (6kg/cm2) |
| 46 | Street Light Service Pillar made out of CRCA sheet with PU painted complete with TPN incoming and outgoing MCCBs, TP contactors, Electronic/ digital/ Mechanical Timers, connectors complete (street Light Pillar) |
| 47 | Earthing with GI earth pipe 2 mts long 40 mm dia medium class with ISI mark, of approved brands including accessories and providing masonry enclosure with CI/RCC cover having locking /Lifting arrangement and watering pipe etc. (but without charcoal or coke and salt) as required as per the Earthing Drawing provided by the Engineer-Incharge.The scope of work includes the following: a) Excavation of pit of size not less than 1.0x1.0x 2.0 mtrs(min) and disposal of excavated soil. b) Class B GI pipe, 40mm diameter as per specifications. c) Charcoal/salt as per specs ( paid seperately). d) Refilling the pit of size not less than 1.0x1.0x 2.0 mtrs(min) with soft black soil of minimum resistivity i/c transportation. e)Masonary chamber with proper foundation, cover plate and locking arrangement. f) Testing of earth value with earth megger and certifications of its value. Aluminium tag with embossed earthing value to be attached to the pipe . g)watering arrangement(plumbing will be paid seperately). |
| 48 | Providing and fixing 6 SWG dia GI wire on surface or in recess for loop arthing . as required Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
TodayCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
TodayCorrigendum-3 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 4 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender