Tender For Supply Of Spares Required For Annual, Routine Work And Break Down Maintenance Work In Rihand Hydro Power Station, Pipri, Distt. Sonebhadra.
Tender Overview
Project Description
Tender for Supply Of Spares Required For Annual, Routine Work And Break Down Maintenance Work In Rihand Hydro Power Station, Pipri, Distt. Sonebhadra. , Dr. Beck Make Red Gel Varnish In 01 Litre Packing , Dr. Beck Make Bectrol Grey Varnish In 01 Litre Packing. , Araldite Packed In 36 Grams. Tube. , Epoxy Resin And Hardener (2:1 Ratio) Packets(5Kg:2.5Kg) , Leather Cock Sheet, Thickness-3 Mm Make-Std , Silica Gel , Permanite Packing, Thickness - 3 Mm , Permanite Packing, Thickness - 2 Mm , Neoprene Rubber Sheet (1M X 2M X 5Mm) , 1P+N Mcb 16 annual periodical maintenance , Double Pole Mcb 32 annual periodical maintenance , Double Pole Mcb 63 annual periodical maintenance , Double Pole Mcb 10-Amp, Dc With C Characteristics , Triple Pole Mcb 25Amp , Triple Pole Mcb 32Amp , Triple Pole Mcb 63Amp , 3 Pole Motor Protection Circuit Breaker Having Overload, Short Circuit And Single-Phase Protection With 1No+1Nc Aux. Contacts. Rated Thermal Current-25A Rated Operating Voltage-690 Vac Rated Service Short Circuit Breaking Capacity-100Ka Over Load Release Range-8.00-12.00A , 3 Pole Motor Protection Circuit Breaker Having Overload, Short Circuit And Single-Phase Protection With 1No+1Nc Contacts. Rated Thermal Current-25A Rated Operating Voltage-690 Vac Rated Service Short Circuit Breaking Capacity-75Ka Over Load Release Range-0.63-1A , 3 Pole Motor Protection Circuit Breaker Having Overload, Short Circuit And Single-Phase Protection With 1No+1Nc Contacts. Rated Thermal Current-25A Rated Operating Voltage-690 Vac Rated Service Short Circuit Breaking Capacity-100Ka Over Load Release Range-2.5-4A , 3 Pole Power Contactor With Dc Coil Suitable For Ac/Dc Switching Rated Insulation Volt: -1000Vac Impulse Voltage: 8Kv Rated Oper Volt: - 1000Vac Ac3 Duty Rating At 415V 3Ph 50/60Hz Rated Oper. Current Ie = 110A Ac Max. Power Rating: 55Kw Max. Electrical Switching Freq: 600 Ops/Hr Dc5 Duty Rating (L/R: -15 Mili Secs) Rated Oper. Amps = 135 Adc Min At 220 Vdc With 3Poles In Series , 3-Phase Heavy-Duty Exhaust Fan, 900 Mm Sweep, 700 Rpm, 415 V, 50 Hz, Complete With Motor And Mounting Accessories. , Digital Volt Meter Ac, With Built-In Selector Switch For Phase Voltage Measurement Seven Segment Red Led Display, 4.5 Digit. Range: 0 To 15 Kv Input: 0 To 110V, 50Hz Pt Ratio: (11Kv/Sqrt3) / (110V/Sqrt3) Accuracy: 0.5% Or Better Size: 96 (H) X 96 (W) Mm Display Height: 12.5 Mm Panel Mounting Flush Type Aux. Supply: 220V Ac +/- 10%, 1 Phase, 50 Hz Insulation Test Voltage: 2 Kv Ac/Min , Digital Ammeter Ac With Built-In Selector Switch For Phase Current Measurement, 4 1/2 Digit 0-4000A Ac 7 Segment Red Colour Cal With 4000A/1A Ct Accuracy: 0.2% Size: 96*96Mm Aux. Power Supply: 220Vac +/- 10%, 1Ph, 50Hz Flush Mounting Insulation Level: 2Kv Rms For 1 Min. , Oil Flow Indicator Flow Direction-Right To Left (01 No) And Left To Right (01 No.) Dia-100 Nb Oil Flow Rate-1100 Lpm Double Contact Switch
BOQ
| Sl. No. | Item Description |
| 1 | Dr. Beck Make Red Gel Varnish In 01 Litre Packing |
| 2 | Dr. Beck Make Bectrol Grey Varnish In 01 Litre Packing. |
| 3 | Araldite packed in 36 grams. Tube. |
| 4 | Epoxy Resin and hardener (2:1 ratio) packets(5Kg:2.5Kg) |
| 5 | Leather cock sheet, Thickness-3 mm Make-STD |
| 6 | Silica gel |
| 7 | Permanite packing, Thickness – 3 mm |
| 8 | Permanite packing, Thickness – 2 mm |
| 9 | Neoprene Rubber Sheet (1M X 2M X 5mm) |
| 10 | 1P+N MCB 16 Amp |
| 11 | Double Pole MCB 32 Amp |
| 12 | Double Pole MCB 63 Amp |
| 13 | Double Pole MCB 10-amp, DC with C Characteristics |
| 14 | Triple Pole MCB 25Amp |
| 15 | Triple Pole MCB 32Amp |
| 16 | Triple Pole MCB 63Amp |
| 17 | 3 Pole Motor Protection Circuit Breaker having overload, Short Circuit and single-phase protection with 1NO+1NC Aux. Contacts.Rated Thermal Current-25ARated Operating Voltage-690 VACRated Service Short Circuit Breaking Capacity-100KAOver Load Release Range-8.00-12.00A |
| 18 | 3 Pole Motor Protection Circuit Breaker having overload, short Circuit and single-phase protection with 1NO+1NC Contacts.Rated Thermal Current-25ARated Operating Voltage-690 VACRated Service Short Circuit Breaking Capacity-75KAOver Load Release Range-0.63-1A |
| 19 | 3 Pole Motor Protection Circuit Breaker having overload, short Circuit and single-phase protection with 1NO+1NC Contacts.Rated Thermal Current-25ARated Operating Voltage-690 VACRated Service Short Circuit Breaking Capacity-100KAOver Load Release Range-2.5-4A |
| 20 | 3 Pole Power Contactor with DC Coil Suitable for AC/DC SwitchingRated Insulation Volt: -1000VACImpulse Voltage: 8kvRated Oper Volt: - 1000VACAC3 Duty Rating at 415V 3Ph 50/60HzRated Oper. Current Ie = 110A ACMax. Power Rating: 55KWMax. Elect. Switching Freq: 600 Ops/HrDC5 Duty Rating (L/R: -15 Mili Secs)Rated Oper. Amps = 135 ADC Min At 220 VDC with 3poles In Series |
| 21 | 3-Phase Heavy-Duty Exhaust Fan, 900 mm Sweep, 700 RPM, 415 V, 50 Hz, complete with motor and mounting accessories. |
| 22 | Digital Volt Meter AC, With Built-In Selector Switch for Phase Voltage MeasurementSeven Segment Red Led Display, 4.5 Digit. Range: 0 To 15 KVInput: 0 To 110V, 50HZPt Ratio: (11KV/Sqrt3) / (110V/Sqrt3)Accuracy: 0.5% Or BetterSize: 96 (H) X 96 (W) MmDisplay Height: 12.5 MmPanel Mounting Flush TypeAux. Supply: 220V Ac +/- 10%, 1 Phase, 50 HzInsulation Test Voltage: 2 Kv Ac/Min |
| 23 | Digital Ammeter AC with Built-In Selector Switch for Phase Current Measurement, 4 1/2 Digit0-4000a Ac7 Segment Red ColourCal With 4000a/1a CtAccuracy: 0.2%Size: 96*96mmAux. Power Supply: 220vac +/- 10%, 1ph, 50hzFlush MountingInsulation Level: 2kv Rms For 1 Min. |
| 24 | Oil flow IndicatorFlow Direction-Right to Left (01 No) and Left to Right (01 No.)Dia-100 NB Oil Flow Rate-1100 LPMDouble Contact Switch Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender