Tender for Construction Of Sub-Tehsil Office Building In Majri,Mc Kurali,Assembly Constituency Kharar Distt. Sas Nagar.
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in Soil (any type) using Hydraulic Excavator CK 90 with hydraulic excavator of 0.9 cum bucket capacity including cutting, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, including all lifts and combined lead upto 30m.Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating leadupto 30 metres |
| 2 | Providing and applying Anti Termite Treatment using pre constructional chemical treatment measures as per IS - 6313 - 2001 ( Part 2 ) & using Chemical containg chloropyrifos systemic insecticide diluted to manufacturer's specifications (i) In foundation pits, by treating the bottom & sides upto height of 300mm by uniformly spraying solution @ 5 Litre / Sqm (ii) In the refill earth on both sides of all built up walls @ 7.5 Litre / Running meter ( width - 300 mm, depth - 450 mm ) (iii) Before laying the floor, by uniformly sprinkling the top surface of the consolidated earth within the outer perimeter @ 5 Litre solution per Sqm. |
| 3 | Cement concrete 1:5:10 with 40mm gauge stone aggregate. using concrete mixer volumetric type |
| 4 | Cement Concrete 1:4:8 with stone ballast of size. Using concrete mixer volumetric type. |
| 5 | Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixture as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth |
| 6 | First class burnt brick laid in cement sand mortar 1:6 in foundation and plinth |
| 7 | Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% taking outside the premises in 15 cm layers including ramming, watering and consolidated leadupto 1000 metres. |
| 8 | 12.5 mm thick cement plaster in damp proof course 1:3 with two coats of bitumen at 1.65 kg/sqm laid hot and sanded |
| 9 | First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level.In Ground Floor |
| 10 | In First Floor |
| 11 | In 2nd Floor |
| 12 | Extra for work done in additional storey upto 4 metre above the top of structural roof of lower storey for Brick Work/ Concrete Block/ Clay Block.In First Floor |
| 13 | In 2nd Floor |
| 14 | 115 mm thick brick wall with every fourthcourse reinforced with hoop iron laid in 1:4 cement mortar in superstructurer. |
| 15 | In First Floor |
| 16 | Extra for 115mm/100mm thick walls for additional storey upto 4 meters above the top of structural roof of lower storey for Brick Work/ Concrete Block/ Clay Block.In First Floor |
| 17 | Reinforced cement concrete M-25 conc. Mixer volumetric type as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure. In Ground Floor |
| 18 | In First Floor |
| 19 | In 2nd Floor |
| 20 | Extra for R.C.C/PCC. work done in each subsequent storey above the first storey up to height of 4 metres or part thereof up to the roof top level of that storey.In First Floor |
| 21 | In 2nd Floor |
| 22 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) |
| 23 | Centering and shuttering for columns (Square or rectangular or poly gonal in plain)Column upto GF Slab |
| 24 | Column upto GF Slab to FF Slab |
| 25 | Column upto FF Slab to 2nd F Slab |
| 26 | Extra rate for shuttering in each subsequent storey above the first. Storey work done in subsequent storey above the first storey up to height of 4 metres or part thereof up to the roof top level of that storey.For First Floor |
| 27 | For 2nd Floor |
| 28 | Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers,lintels.In G.F |
| 29 | In F.F |
| 30 | In 2nd Floor |
| 31 | Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.In G.F |
| 32 | In F.F |
| 33 | In 2nd Floor |
| 34 | Centring and shuttering for stair cases with sloping with soffits including risers and stringers.In G.F |
| 35 | In F.F |
| 36 | Centering and shuttering for faces of walls, partitions, retaining walls and the like (vertical or battering including attached pilasters buttresses etc. |
| 37 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including binding, bending and placing in position complete |
| 38 | 12.5 mm thick cement plaster 1:4GF |
| 39 | 2nd Floor |
| 40 | 20mm thick cement plaster 1:5 in two coat workGF |
| 41 | 2nd Floor |
| 42 | Plastering on under of ceilling 10mm thick cement plaster 1:4GF |
| 43 | 2nd Floor |
| 44 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish GF |
| 45 | 2nd Floor |
| 46 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade GF |
| 47 | 2nd Floor |
| 48 | Finishing wall with premium Acrilic smooth exterior paint with sillicon additive of required shade with two coats applied @ 1.43 liter/10 sqm over and including base coat of water proofing cement paint applied 2.20 kg /10sqm GF |
| 49 | 2nd Floor |
| 50 | Base course of flooring consisting of 100mm thick cement concrete 1:8:16 and 100 mm sand filling |
| 51 | Screed of 50mm thick cement concrete 1:8:16 to be laid below the topping |
| 52 | Providing and laying vitrified floor tiles in different sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Full body vitrified tiles have pigment in entire body / thickness of tile which makes chips and scratches less noticeable and make na ideal choice for high traffic zones.) |
| 53 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. |
| 54 | Deduct for not grouting the joints with white cement and matching pigment in the items of fixing of vitrified tiles. |
| 55 | Providing & fixing 16 gauge stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts grouted on steps with hand rail and newel post of 50mm dia Stainless steel pipe,Balusters of 40mm dia Stainless steel pipe and guard 3 Nos of 15mm dia Stainless Steel pipe complete in all respect |
| 56 | Providing and fixing Stainless Steel specials & fitting ( such as Elbow, Tee, Reducers, Sockets etc) of grade A ISI-304 as per IS standard 3448 complete for press type fitting (fitting shall be paid for separately) i/c fixing of the fittings with pipe & making good the walls including testing of joints complete as per direction of Engineer-in-charge. |
| 57 | Marble stone flooring with 12-15 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : Udaipur Green Marble Tiles of thickness12mm to 15mm Slabs sizes above 0.50 sqm. |
| 58 | Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps. |
| 59 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes single socketed (working pressure 4 kgf / cm²) conforming to IS : 4985, including fixing with MS clamps U-PVC pipes (working pressure 4 kg / sqcm) pipe 160 mm dia |
| 60 | Providing and fixing 160mm dia SWR U.P.V.C bend for rain water pipe as per IS: 14735 including jointing complete as per specifications and to the entire setisfaction of engineer-in-charge. UPVC 160mm bend |
| 61 | Providing and fixing 160mm dia SWR U.P.V.C coupling/sockete for rain water pipe as per IS: 14735 including jointing complete as per specifications and to the entire setisfaction of engineer-in-charge. UPVC 160mm coupling / Socket |
| 62 | Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire |
| 63 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. |
| 64 | Top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50.00 thick cement concrete 1:8:16 |
| 65 | Bottom khurra on ground 1.2m 0.6m consisting of bricks on edge laid in cement mortar 1:3 over 7.5 cm cement concret 1:8:16 including 12.5mm thick cement plaster 1:3 |
| 66 | For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug / neoprene gasket required |
| 67 | Supply & Fixing of Window frames (Chowkhats) including mullions consisting frame fabricated from sheet roll formed out of 0.58mm thick galvanished sheet (base steel as per IS : 513) with zinc of 120gm/sqm steel sheet pre coated (as per approved colour) with polyster paint of 12-16 micrones thickness under coat of EPOXY prime & back coated with ALKYD backer of 5-7 micrones total thickness of coating 0.58mm of approved shade, fixed in position by means of PVC & metal hold fastner with PVC cap complete in all respects as per drawing, design, specification & entire stasfication of Engineer-in-Charge., Window outer frame of size 72mm x 55mm and central mullion 72mm x 50mm with Double rebate. |
| 68 | Providing Polyester Powder coating 50 micron any coloured specified to alumnum section of various sizes including carriage of material from market to workshop & workshop to site of work. |
| 69 | Supply & Fixing of door frames (chowkhats) consisting frame fabricated from sheet roll formed out of 1.2mm thick galvanized sheet as per IS:277 (base steel as per I:513) with zinc of 120gm/sqm & upto 50 micrones (as per approved colour), 3 Nos 100mm but hinges 2mm thick, 6 nos 1.2mm thic CRCA electroplated stiffner, 6 nox M.S hold fast with split and tail welded to stiffner plate 200mm long, Receiver for aldrop, M.S tie rod 50mm x 25mm to be fixed at bottom finished with powder coated total thickness of coating 0.60 mm of approved shade, fixed in position, including the cost of cement concrete for 1:2:4 for fixing lugs complete in all respects as per drawing, design, specification & entire stasfication of Engineer-in-Charge., Doors frame of size 80mm x50mm with 37 mm wide single rebate for 35mm door shutter. |
| 70 | Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position(Code : II Revision IS-2191 Part-I) 1973Decorative with teak facing on both sides edges lipped with teak with laminated core35mm thick |
| 71 | Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt) |
| 72 | Providing and fixing hydraulic door closer ISI mark with necessary screw etc. complete I.S.I Designation No. II (size ofdoor 701mm to 850mm) |
| 73 | Providing anf fixing Sliding Bolt 300mm |
| 74 | Providing & fixing of Box type steel windows, made of various ERW section outer 60mm x 25mm, central mullion 60mm x 25mm, for shutter 50mm x 20mm having thickness of 1.25mm (18 gauge), shash bar MS Tee 25mm x 3mm where required joints mitered and electrically flash- welded, with iron fittings including necessary iron handles, hinged cleat, tower bolts, iron hold fast and pintle hinges complete (excluding glazing and wire gauge) and finished with ready mixed paint red lead non setting primer complete as per specification, Drawings and to the entire satisfaction of engineer-in-charge. (Note:- Glazing, wire gauge and grill will be paid as per respective items) |
| 75 | Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make.Glass panes 5mm or 10.75 kg / sqm exceeding 0.4 sqm of area |
| 76 | Wire gauge fixed in steel windows, of standard rolled steel section with 3mm thick flat iron cover moulding of 12.5 mm width, fixed with machine screws, complete in all respects. |
| 77 | Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position |
| 78 | Providing and Fixing ceiling consisting of 12.5mm thick Gypsum Board of any size G.I. Cradling hanged from the ceiling by means of G.I. hanger complete as per drawings,specifications and tothe entire satisfaction of engineer-in- charge. |
| 79 | Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflection > 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. |
| 80 | Dismentalling, Stripping and stacking slate or tiles of a roof. |
| 81 | Dismantling concrete or precast concrete. .(e) Reinforced Cement concrete |
| 82 | Removing Doors and Windows (Steel or wood) with chowkhats by making recesses in walls when the wall is not to be dismantled |
| 83 | Dismantling brick work tile, masonry or tile lining In cement |
| 84 | Dismantling cement conglomerate floors (25mm to 50mm) thick without concrete base complete in all respect as per PWD specifications |
| 85 | Disposal Of Malba at 5 km lead |
| 86 | Plinth Protection Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres. |
| 87 | Cement concrete 1:6:12 With stone aggregate 40mm gauge mixing by mechanical means using concrete mixer volumetric type |
| 88 | First class burnt brick laid in cement sand mortar 1:6 in foundation and plinth. |
| 89 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 and 100mm sand filling using mechanical mixer for mixing of material |
| 90 | Cement concrete 1:2:4 mixing by mechanical means using concrete mixer volumetric type |
| 91 | 12.5 mm thick cement plaster. |
| 92 | Construction of Parking & Roads Construction of Embankment with Good QualityEarth obtained from Borrow pits Construction of embankment with good quality earth obtained from borrow pits including compensation of earth, loading, unloading, carriage to site of work, spreading, grading to required slope and compacting to meet requirement of table 300-2 as per technical clause 305 of MORT&H specifications. |
| 93 | Compaction of earth work & Prepration of Sub grade including loosing,leveling of earth 225mm thick top layer, rough dressing of soil, final dressing of earth to give level camber,watering,rolling with road roller, compacting the bed to achieve minimun dry density as given in Table 300-2 as per technical clause 305 of MORT&H specifications |
| 94 | Cement concrete 1:4:8 with stone bllast of 40mm gague stone aggregates mixing by mechanical means using concrete mixer volumetric type |
| 95 | Providing and laying 60 mm thick factory made cement concrete interlocking Paving blocks of M-35 grade manufactured by block making machine equipped with steel mould clamped to a strong vibratory table with hydraulic pressure for compaction of concrete as per IRC SP 63 -2014 and of approved size and design / shape laid in Ordinary Grey Colour and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in- Charge. |
| 96 | Providing and laying factory made rubber moulded smooth finish cement concrete Kerb M-20 grade 250mm high with bottom width 165mm and top width 115mm made over strong vibratory table and fixing with cement mortar 1:2 as per MORT&H specifications |
| 97 | Providing and laying factory made rubber moulded smooth finish cement concrete Channel M-20 grade 300mm wide and 75mm thick made over strong vibratory table and fixing with cement mortar 1:2 as per MORT&H specifications |
| 98 | Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface |
| 99 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade |
| 100 | Construciton of Parking Shed Excavation in Soil (any type) using Hydraulic excavator CK 90 with Hydraulic excavator of 0.9 cum bucket capacity including cutting, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections including all lifts and combined lead upto 30m. Earth filling under floor with surplus |
| 101 | Cement concrete 1:4:8 with stone aggregate 40mm gauge. mixing by mechanical means using concrete mixer volumetric type |
| 102 | Reinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth.(as per A&C Slip-1 dated 20.10.20) |
| 103 | Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure. |
| 104 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 550 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including binding, bending and placing in position complete |
| 105 | Nuts & Bolts of all sizes and length required |
| 106 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) |
| 107 | Centering and shuttering for columns (Square or rectangular or poly gonal in plain) |
| 108 | Steel work fixed independently without connecting plates including cutting hoisting and fixing in position. |
| 109 | Structural steel work in angles, tees, flats, riveted, vincluding cutting, fixing all gusset plates, bolts, nuts, rivets etc. with hoisting and erecting in position.For plates and trussed girders etc. for bridge of span more than 15 metres but upto 30 mts. Span including cost of all machinery i.e hydra crane etc |
| 110 | Steel work in built up tubular (round, square or rectangular hollow tubes etc. ISI marked) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete having span:-Up to 15.00 Mtr. Span |
| 111 | Above 15.00 mt. Span including the cost for machinery i.e. Hydra cranes etc. for hoisting in position. |
| 112 | Providing and fixing ( PPGL) precoated painted galvalume sheet roofing (size, shape and pitch of corrugation as approved by Engineer-in-charge)The end rib shall have anti cappillary groove and return leg. The steel sheet must be having yield strength of 550 MPa ( Fy= 550 MPa) metalliccoated with Zinc- Aluminium alloy ( i.e. 55% Al, 43.4%Zinc, 1.6% Si-Zincalume) AZ150 ( Min. 150 bm/mm2 total on both sides), pre painted with super Durable Polyster XRW quality paint includes inorganic infrared reflective pigment. The sheet confirms to general requirement of AS/NZS 2728 type 4/ IS 15965 class 3 durability and gloss value of 25% -40%. should be supplied in single length upto 12 metre or as desired by Engineer-incharge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.50 mm (+ 0.05 %) thick |
| 113 | Applying priming coat with metal primer on new steel or iron work including preparation of surface and Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
| 114 | Extra rates for white washing, distempering, painting and decorative cement based paints etc for superstructure Where any single storey height exceeding 4 mtr in height for every additional height of 2 mtr or part thereof (External or Internal) |
| 115 | Sanitary Installation Providing and fixing in position set of EWC and WHB size 46x36 cm for Handicapped person of approved make (to the approval of the Engineer-in-charge) consisting of matching cistern, one pair mounting brackets, seat cover, one no. hinges rail 76cm and 4 no. grab rails 60cm complete in all respect and to the entire satisfaction of Engineer-in-charge. |
| 116 | Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI marked, PVC short bend 32 mm dia including cost of seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. |
| 117 | Extra for providing and fixing 10 litres capacity Chinaware low level flushing cistern with PVC internal fitting, instead of 10 litres capacity PVC flushing cistern. |
| 118 | Providing & fixing in position vitreous chinaware white indian make large flat back or angular lipped front urinal 375 x 390 x 590 mm approved make as per csr item 30.16 |
| 119 | Providing and fixing in position C.P. Brass Urinal button flusher 15 mm of approved make (to the approval of Engineer-in-charge) |
| 120 | Providing and fixing in position vitreous chinaware white lavatory suites of approved make consisting of C.P brass waste 32mm dia with one C.P brass pillar tap complete in all respects .560 mm x 450 mm (under counter oval ) |
| 121 | Extra for providing and fixing C.P Brass short flush bend 32mm instead of PVC short bend. |
| 122 | Providing & fixing Jet spray with 2'-6\\" long PVC pipeWith C.P Brass nut |
| 123 | Providing & Fixing in position C.P. Brass Hexa Nipple 15mm of approved make (to the approval of Engineer-in-charge ) complete in all respect. |
| 124 | Providing & fixing PVC waste pipe 32mm complete in all respect. |
| 125 | P/F in position towel rails/ring of approved make fixed in with rawl plugs embedded in walls with brass screws complete in all respect.C.P brass towel ring |
| 126 | Providing and fixing in position paper holders of approved make (to the approval of Engineer-in-charge ) fixed in to wall with C.P brass screws complete in all respect.C.P. brass toilet paper holder |
| 127 | Providing & Fixing in position C.P./Aluminium Khunti of approved make (to the approval of Engineer-in-charge ) fixed into wall with C.P. brass screws and rawl plugs etc. complete in all respect.C.P. Brass khunti with 3 pegs |
| 128 | Prov. & fixing in position C.P brass soap dish of approved make fixed into wall with rawl plugs and c.p brass screws complete in all respects. |
| 129 | Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on top complete in all respect (as required by the Engineer-in- Charge)Size 600mm x 450mm |
| 130 | Providing & Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer-in-charge) under various fixtures complete in all respect. |
| 131 | Providing & Fixing in position C.P. Brass extension piece 25mm long to 100mm long of approved make (to the approval of Engineer-in-charge )with various fixtures complete in all respect.C.P. Brass extension piece, 25mm long to 50mm long |
| 132 | Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect.C.P. brass Bib cock long nose/ long body foam flow without flange |
| 133 | C.P. brass Bib cock foam flow without flange |
| 134 | Providing & Fixing in postion stop cock / Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect.C.P.brass 15mm stop cock Male and female end |
| 135 | Providing and fixing in position premium range C.P. Brass Fittings and accessories of approved make (to the approval of Engineer-in-charge ) complete in all respect.C.P. Brass Pillar Cock foam flow |
| 136 | Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect.PVC tube connection of size 15mmx 300mm with C.P brass nut |
| 137 | Prov & fixing in position SWR UPVC soil waste vent or antisyphonage pipes as per IS 13592 of approved make including cutting, joiting wastrage, but excluding cost of lead jointing.Single Socket Type B110mm o/d SWR UPVC pipe lines laid complete |
| 138 | 90mm o/d SWR UPVC pipe lines laid complete |
| 139 | Providing and fixing in position SS Grating with frame of approved make (to the approval of engineer in charge) complete in all respects. |
| 140 | Providing & fixing in position C.P. copper tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect.C.P. copper tube connection of size 15 mm x 600 mm with C.P. Brass nut |
| 141 | Providing & fixing in position C.P brass Sink mixer swivel spout (Wall mounted) ofapproved make (to the approval of Engineerin- charge) complete in all respect. |
| 142 | Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. For 110mm o/d Single Tee |
| 143 | Single Y-Junction with door |
| 144 | Elbow (90) degree |
| 145 | Coupler |
| 146 | Vent Cowls |
| 147 | P Trap / Floor Trap 110mm x 110mm |
| 148 | For 90 o/dSingle Tee with door |
| 149 | Elbow (90) degree |
| 150 | Coupler |
| 151 | Vent Cowls |
| 152 | Cutting chase in brick walls in cement or in floor for embedding G.I or C.I pipes line and making good the same to its original condition.Size 75mm x 75mm |
| 153 | Providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 154 | Providing and fixing in position automatic brass Ball Cock in tanks.Brass Ball Cock with rod and Plastic Ball25mm i/d |
| 155 | Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer - in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank.Triple Layer tanks2 Nos. x 5000 = 10000 Ltr |
| 156 | Providing and fixing in position G.I. Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respect.G.I. tank nipple 25mm i/d |
| 157 | G.I. tank nipple 50mm i/d |
| 158 | Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm.100mm internal Diametre S.W.gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm |
| 159 | Providing and fixing partition for different type of urinals.19 to 20 mm thick Granite stone partition size 375mm x 750mm |
| 160 | Providing and fixing in position CP Brass Grab Bar of approved make (to the approval of the Engineer-in-charge) fixed in to wall with brass screws complete in all respect.Providing & fixing in position stainless stell sinks of approved make 1mm thick, grade 304 with waste coupling complete in asll respectDouble bowl Sink without drain board Overall size 1114 x 490 mmwith bowl size 460x385x200mm including waste coupling |
| 161 | Providing & fixing in position C.P brass Sink mixer swivel spout (Wall mounted) of approved make (to the approval of Engineerin- charge) complete in all respect. |
| 162 | Providing ,laying, jointing, fixing and testing ISI Marked G.I. Pipe (as per IS 1239) B- Class including cost of specials (such as tees, bends, sockets, elbows etc.) ,painting with anti corrosive bitumastic paint, testing, cutting, threading Inside building complete.Size 25mm i/d ( From Oht to shaft vertically upto bottom of 20mm connection) |
| 163 | Size 20mm i/d ( From wall to internal circulation) |
| 164 | Size 15mm i/d ( from circulation to tap/ faucet) |
| 165 | Providing, fixing and jointing ISI Marked Gun- Metal peet valves (Heavy Pattern) as per IS 778 with hand wheels, on G.I. Pipe lines laid in the ground or inside buildings including all carriages complete.25mm i/d Gun Metal peet valve heavy pattern. |
| 166 | 20mm i/d Gun Metal peet valve heav pattern. |
| 167 | Providing, fixing and jointing G.I Union Couplings(of approved make with the approval EIC) as per IS 1879 in G.I. Pipe lines complete in all respect.20mm i/d G.I. Union |
| 168 | 25mm i/d G.I. Union |
| 169 | Water cooler systemProviding & fixing in position Water Cooler without Stablizer of approved make (to the approval of Engineer-in-charge ) including carriage complete in all respect.Water Cooler Full Steel Body 150/150 ltr without Stablizer |
| 170 | Providing and fixing in postion storage type automatic electric water heater pressure type thermostatically controlled, single phase wall mounted of approved make (to the approval of Engineer-in-charge) with thermostats, inner container of stainless steel, Inner glass lining with B-Rating minimum 3 stars complete with 1 Mtr. three core flexible cord with plug, non return valve and pressure release valve complete including fixing and testing complete in all respect. A-vertical type 25 litre capacity water heater |
| 171 | AUTOMATIC VOLTAGE STABLIZER, TIMER:Supply and erection of Single phase copper wound Automatic voltage stablizer of suitable capacity electronically controlled circuit with input voltage 140-260 volts single phase AC supply and output voltage 220 ± 5% volts single phase AC supply having main silicon core copper wound step up transformer with suitable nos. of turns on primary side and secondary side the transformer should be fully insulated inside the MS sheet box of suitable size. There should be power control relay and single pole MCB (C-curve, 10kA) of suitable capacity complete with internal copper wiring along with amp. meter and volt meter, high voltage cut off 280 volt input (240 volt output) and 90 volt maximum boost and overloading protection to be provided:-Automatic Voltage Stablizer 4 KVA |
| 172 | Providing & fixing in position UV filter having flow rate 200 ltr/hr with 3 stage purification process having 16 watt UV lamp and 35 Watt power rating of approved make (to the approval of Engineer-in-charge ) including carriage and fixing in position complete in all respect. |
| 173 | Foundation & provision for RCC Slab for water Storage Tank |
| 174 | Flooring & wall tilesColoured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps.. |
| 175 | Extra Rate for First Floor |
| 176 | Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 600 x 300 mm as approved by Engineer-in- Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement:4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 177 | Extra Rate for First Floor |
| 178 | Providing and laying Rectified Porcelin floor tiles 400x400mm or more (thickness to be specified by the manufacturer) of premium quality conforming to IS:15622 of approved make in all colours laid on 20mm thick bed of Cement Mortar 1:4 ( 1 Cement : 4 Fine sand) for new flooring or laid with cement based high polymer modified quick set tile adhesive (water based) of approved make IS 15477 marked using 5 Kg adhesive per Sqm of tile area in average 3mm thickness over existing floor, including pointing the joints with white cement and matching pigments etc., complete |
| 179 | Base coarse of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm guage and 100mm fine sand filling using mechanical mixer for mixing of material |
| 180 | Screed of 50mm thick cement concrete 1:8:16 to be laid below the topping using mechanical mixer for mixing of material- First floor |
| 181 | Extra Rate for First Floor |
| 182 | Extra labour for projected nosing of stair case of any shape and design |
| 183 | Electrical Work Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\\" deep for walls and CI 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-Wiring fan point (With fan box) |
| 184 | Wiring light point |
| 185 | Wiring 6Amp. wall socket point |
| 186 | Wiring call-bell point |
| 187 | Wiring 6Amp. Plug control comprising wall socket point |
| 188 | Wiring 16/20Amp. power plug control point |
| 189 | RECESSED COMPUTER SUPPLY TERMINAL POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES):Wiring Computer supply terminal points recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10/16/20Amp. Switches and blanking plate etc., and covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):-Wiring Computer terminal point having 3 Nos. 6Amp. 2/3 universal socket (shuttered), 1No. 16/20Amp. universal Socket (shuttered), 2Nos. 16/20Amp. switch with indicator and 2Nos. blanking plate (Modular accessories). |
| 190 | RECESSED AIR CONDITIONER SUPPLY TERMINAL POINT (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES):Wiring air conditioner supply terminal point recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp. combined/ universal Socket (shuttered) and modular motor starter 25Amp. (2Module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):-Wiring AC supply terminal point having 1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. erected at switchboard height. |
| 191 | RECESSED TV, TELEPHONE & NETWORKING SOCKETS OUTLET POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES):Supply and erection of TV socket, Telephone socket and Networking socket points in powder coated/anodized concealed metal boxes recessed in wall required for suitable number of modules (Modular accessories) for having TV sockets, Telephone sockets RJ11 & Networking socket RJ45 (one module), covered with Frame Plate and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-Wiring TV socket point (one module) |
| 192 | PVC INSULATED FR COPPER CONDUCTOR CABLES:Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-Overall size 1.5sq.mm (Un-sheathed) |
| 193 | Overall size 2.5sq.mm (Un-sheathed) |
| 194 | Overall size 4sq.mm (Un-sheathed) |
| 195 | Overall size 10sq.mm (Un-sheathed) |
| 196 | Overall size 16sq.mm (Un-sheathed) |
| 197 | XLPE INSULATED UN-ARMOURED CABLES (LOOSE):Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-Overall size 16sq.mm (2Core) Un-armoured (Loose) |
| 198 | Overall size 70sq.mm (3½ Core) Un-armoured (Loose) |
| 199 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed) |
| 200 | Heavy Gauge PVC Conduit Pipe 40mm dia. (Flushed) |
| 201 | DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES:Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:-Double Walled Corrugated HDPE Pipe 63/ 51mm (Outer/ Inner dia.) |
| 202 | COPPER EARTHING:Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:-Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 4.50 metre (14.76 feet) below ground level (up to 8metre in Length) with G.I. pipe 20mm dia. (A-class), 3metre long |
| 203 | COPPER EARTHING STRIP (As Additional Length):Fixing additional Length of earthing with Copper Tape (On Surface/Flushed) with petty material as required etc.:-Additional Length 20mm x 3mm thick Copper Tape |
| 204 | MINIATURE CIRCUIT BREAKERS/ RCBO's/ RCCB's:Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-MCB Single Pole 6-32amp. (10kA, Curve-C) |
| 205 | MCB Four Pole 50, 63amp. (10kA, Curve-C) |
| 206 | SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB's/ RCBO's/ RCCB's:Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:-TP&N Horizontal Double Door Distribution Board 6 way each |
| 207 | TP&N Horizontal Double Door Distribution Board 8 way each |
| 208 | LT PANELS:Designing, Supply, Erection, Testing & commissioning of indoor Type LT cubical panel enclosure (dust, vermin and interchangeable modules with facilites for extensions or reduction as per the space or requirments). The Panel shall be suitable for operation at 415+6% Volts, 50HZ, 3 phase 4 wire & earth system. The assembly manufacturer should be ISO approved and CPRI tested for short circuit of (minimum 50kA) as well as IP degree of protection (IP 54/55).Fabrication:- Panel shall be made from 14/16 SWG CRCA sheet, conforming to IS 8623/1977-82. The sheet metal used for the fabrication of control panel will be 2mm for load bearing member’s door and fittings plates etc. the partitions and other non load bearing members will be fabricated out of 1.6mm sheet, the sheet will be of mild steel CRCA type. The base channel will be made out of 75 x 40 x 5mm rolled channel. The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The panel door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. Minimum depth 400mm / wide 300 mm for busbar/ Cable ally at the front of the panel. The panel will be free standing floor mounting type having provision for cable entry from bottom/top with cable glands etc.The fabrication should be such that all the member i.e. vertical/horizontal should be detachable type i.e. total bolted. In case of any changes required at site. it should be possible then and their self without any cutting or welding. The fabrication of the panel in 3B construction fully compartmentalized type i.e. bus bar chamber as well as the cable chamber should be totally isolated from the feeder chamber. Where there crossing of the wire or bus links. It should have proper rubber gourmets or non-hygroscopic material. No live part should be in visible condition.Painting:- The sheet metal is sprayed with corrosion resistant etch Primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work . Busbars:-The panel shall be provided with TPN aluminium busbar of suitable size according to the size of MCCB's. Busbar shall be of high conductivity (53% to 58%) E91-E Grade aluminium (1A/Sq.mm). All Busbar will be air insulated with codified in Red, Yellow, Blue & Black as per standard for cable termination with the help of extended busbar only with proper adjustable cable supports. The main busbar would be supported upon non-hygroscopic SMC/DMC supports. Metering:-The panel shall be completed with digital metering unit (with selector switches, voltmeter & ammeter) epoxy insulator, gasket, PVC sleeves, CT's & L.E.D. type indicator etc. Manufacturer of Panel should be CPRI Approved (Approval not older then 5 years) & ISO certified (Manufacturer workshop as per ISO 9001: 2015 standard) The Concerned contractor shall be approved the detailed drawing of panel with complete specification from the Engineer in charge at site.Detail of capacities of MCCB's to be installed in the cubical panel Enclosure (Excluding the cost of MCCB's) as per following:-LT Panel enclosure having space for 1No. Incomer MCCB 200Amp. and 4Nos. outgoing MCCB's 40amp. to 100amp. according to the requirement at site (Approx. size 1825 x 1000 x 300mm) |
| 209 | MCCB's (FOR PANELS & SHEET ENCLOSURE):Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader terminal links, Extended rotary handle and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:-MCCB Four Pole 63/80/100amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting |
| 210 | MCCB Four Pole 200amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting |
| 211 | Supply and erection of LED batten 20watt LED (including LED driver) with High quality extruded aluminium with efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 % complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. Beside this the lighting manufacturer should have inhouse NABL accurdited Lab. |
| 212 | Supply and erection of LED Batten 36/40watt LED with high quality extruded aluminium with efficancy of LED Fixture minimum 100 lumens per watt and operating voltage between 140- to 270 volt input AC Frequency 50 + 3% complete along with erection of the same with connections testing etc. complete in all respects as approved and desired by the Engineer in charge at site. The certification and Specifications of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021.Beside this the lighting manufacturer should have inhouse NABL accreted Lab. |
| 213 | Supply and erection of LED Panel 36 Watt Body White shape square type of item Resses/on Surface 2X2 Warranty 2 year 36W LED Colour Temerature CDL(65k/CDL(57)/NWH(4K) Product Dimensions S-595XH-70MM Body Material Metal Width 595mm Height 70mm Power Factor>0.90: System lumens 3200Im: thd<10%: Wattage 36 W , complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021.Beside this the lighting manufacturer should have inhouse NABL accreted Lab. |
| 214 | Supply and Erection of LED Flood light 100 Watt Luminaire having Pressure die cast Aluminium housing along with IP66 ingress Protection, 4KV inbuilt surge protection, input oprating voltage- 140-270 volt AC, 50 hz +- 3% input frequcency, minimum IK07 rating, Minimum 120 Lumens/watt & Robust sink complete in all respects as desired by the Engineer in charge of work at site.The certification and Specifications of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. |
| 215 | Supply and Erection of 3 Star Rating Ceiling fan Suitable size 48\\" (1200mm) Full Aluminium Body, 3 Nos. of Blades, white in colour. The mounting type is down rod mount. The product should possess a minimum air delevery of 218 CMM. The rated speed of the product must be minimum of 350 revolutions per minute and 5 Nos, of speed. The approximate weight of the product should be 4kg and 180gms (without packing) or higher. The product should have a manufacturer's guarantee/ warranty of minimum 2 years. The product should be complete in all respects with fan motor, bladeset, down rod, conopy set, shackle kit, twisted wire etc., including erection & testing of ceiling fans having connection with PVC insulated PVC sheathed tow single core copper conductor (FR) cable 0.75 SQ MM. Complete in all respects as desired by the Engineer in charge of work at site. The Product should be BEE & BIS Certified. |
| 216 | Supply & erection of Wall Fan size 400MM including Connection & Testing complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 217 | Supply & erection of Exhaust fan of suitable size 12'' 300MM Sweep of including connection & testing complete in all respect as desired by the Engineer in-charge of work at site. |
| 218 | COPPER CONDUCTOR CABLES FOR SPECIAL ELECTRICAL SERVICES:Supply and erection of CAT 6 with 23AWG solid bare copper conductor, special grade PE insulation with star separator, 4pair Unshielded Twisted Pair (UTP) industrial cable, FR PVC sheathed, Class-E, 250 MHz of bandwidth, supporting data transfer speeds of up to 10 Gbps (10GBASE-T) for distances up to approximately 180 feet, cables are manufactured and tested to meet the ANSI/TIA 568-C.2 and ISO/IEC 11801 Class E standards left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-CAT 6 LAN cable |
| 219 | RECESSED TV, TELEPHONE & NETWORKING SOCKETS OUTLET POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES):Wiring Networking socket point RJ45 (one module) |
| 220 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-PFA Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed) |
| 221 | SITC of 24 Port L2 managed 10/100/1000 Mbps with 4 No Uplinks RJ45 and SFP Combo 1G Ports Data switch with 4 • IEEE 802.3u 100BASE-TX Fast Ethernet• IEEE 802.3ab 1000BASE-T Gigabit Ethernet• IEEE 802.3az Energy-Efficient Ethernet (EEE)• ANSI/IEEE 802.3 NWay auto-negotiation• IEEE 802.3x Flow Control, Standards • IEEE 802.3 10BASE-T Ethernet Switching Fabric • 30 Gbps Data Transfer Rates • Gigabit Ethernet • 2000 Mbps (full-duplex) • Fast Ethernet • 100 Mbps (half-duplex) • 200 Mbps (full-duplex)• Ethernet • 10 Mbps (half-duplex)• 20 Mbps (full-duplex), PoE Standards • IEEE 802.3af •. CPU RAM 256MB or above, Certification - FCC class A, CE class A, VCCI, BSMI, CCC, CE, LVD, UL, CB Oper Temp- -5 to 50 °C (23 to 122 °F complete in all respect as desired by the engineer in charge at site. |
| 222 | Supply & erection of 24 port Loaded patch Panel complete in all respect as desired by the engineer in charge at site. |
| 223 | Supply & erection of 1 Meter Patch Cord complete in all respect as desired by the engineer in charge at site |
| 224 | Supply & erection of 2 Meter Patch Cord complete in all respect as desired by the engineer in charge at site. |
| 225 | Supply & erection of 12U Wall mount 19’’ Rack with glass door,lock & key facility 400/450/500mm depth AC Fan having 10 no. mounting hardware, Cable entry/exit provision at top and bottom panels, Ventilation slots on top, bottom and side panels, Fixed side panels, Comply IS Standard of Racks. complete in all respect as desired by the engineer in charge at site. |
| 226 | Supply & erection of 1000VA LIT UPS/ Power Plant with SMF batteries having 30 Minutes backup time, Cold Start, 3 No. plug Indian style, Automatic Voltage Controller, Overload protection, Over charging Protection, 2 No. 12v 7Ah Batteries, Wide Input Range, Fan Less Cooling system, Transfer time less than 8ms,Audible Alarm etc. complete in all respect as desired by the engineer in charge at site. |
| 227 | COPPER CONDUCTOR CABLES FOR SPECIAL ELECTRICAL SERVICES:Supply and erection of CAT 6 with 23AWG solid bare copper conductor, special grade PE insulation with star separator, 4pair Unshielded Twisted Pair (UTP) industrial cable, FR PVC sheathed, Class-E, 250 MHz of bandwidth, supporting data transfer speeds of up to 10 Gbps (10GBASE-T) for distances up to approximately 180 feet, cables are manufactured and tested to meet the ANSI/TIA 568-C.2 and ISO/IEC 11801 Class E standards left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-CAT 6 LAN cable |
| 228 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed) |
| 229 | Supply & erection of IP Bullet/Dome FIX Focal CAMERA 5MP IP Camera STQC Approved with Audio Input Support and following features Resolution - 5 MP (2592 x 1944), Sensor Type and Size-1/2.8\\" SONY - CMOS 5MP Active Pixel Progressive Scan, Back Illuminated Image sensor, Minimum Illumination Color - 0.01 Lux @F1.2 (AGC ON), Monochrome - 0 Lux Focal Length-3.6/2.8/4mm, Focus Range - 0.3m to infinity, Field of View (FOV)Minimum-HFOV – 87.6° VFOV – 46.4° DFOV – 104.5° Focus-Fixed focus Aperture (F#) F 1.6 / F 2.0,Iris Type Fixed, IR 30m or above, IR Led Wavelength 850nm, IR Switching Auto/ Manual , Audio IN 1,Audio OUT 1,Two-way Audio Supported, Audio Compression G.726 and G.711μ Alarm In Yes, Alarm Out Yes,SD Card Up to 512GB, Camera Adjustment Angle Pan: 0° to 360° Tilt: 0° to 90° Rotate: 0° to 360°,No of Stream Profiles 4, Stream Profiles- Profile 1: Mainstream - 2592*1944@ 30fps (H.265/H.264), Profile 2: Sub stream - D1@30fps (H.265/ H.264), Profile 3: MJPEG - 2048*1536@8fps (MJPEG) or D1/VGA@15fps(H.264/H.265) Profile 4:1920*1080@30fps (H.265/H.264/MJPEG) Available Resolutions 2592 x 1944, 2592 x 1520, 2048 x 1536, 1920 x 1080, 720p, D1, VGA, 2CIF, CIF, Max Resolution 2592 x 1944, Bitrate 128 kbps-16Mbps, Bitrate Type CBR, VBR, Video Compression H.265, H.264, MJPEG, Frame Rate 1-30fps, Shutter Speed 1/15s -1/100000s,Adaptive Streaming Yes, ONVIF Profiles S, G, and T, Edge Recording Yes, Alarm Recording Pre and Post, Motion Recording Yes, Time Triggered Yes, Video Parameters Snapshot, Region of Interest (ROI), BLC, HLC, Day/Night Settings, Privacy Masks 8, WDR True WDR (120dB), SNR >70dB Image Enhancement Saturation/ Contrast/ Sharpness/Brightness/Auto Exposure/HVS- Forensics/ Smart IR DNR 2D &3D Video Analytics, Motion/No Motion Detection, Tamper Detection, Trip/No Trip Detection, Object Intrusion/Zone Intrusion, Audio Exception, IP Conflict Yes, Network Disconnect Yes, Storage Full Yes, Upload Image SD, NAS, SFTP, Upload Clip SD, NAS, SFTP Notifications E-mail, SMS, TCP, Supported protocols, TCP/IP, UDP, HTTP, HTTPS, DHCP, DNS, Dyn DNS, DDNS, RTP, RTCP, RTSP, PPPOE, SMTP, NTP, SNMP, FTP, TLS/SSL, SFTP, ICMP, IGMPv2 & v3, ARP, 802.1x, IPv4, IPv6, QoS Layer 3, DSCP, CIFS, SSH, UPnP, Bonjour, Web Viewer Supported in IE 8.0-11.0, Firefox 15.0-47.0, Chrome 20.0-54.0, Browser IE, Chrome, Mozilla, CYBER SECURITY as per ISO/IEC 27402-Secure boot Yes, Signed firmware Yes, Data Encryption All data, including sensitive data, is encrypted with AES 256 and RSA 2048, IP Address Filtering Yes, HTTPs Streaming Yes, using TLS 1.2, Edge Data Encryption Yes, Network Authentication Yes,802.1x Network authentication, Secure Firmware Upgrade Yes, Anti-roll back firmware Yes, Web login Password protection Yes, Unused debug interface protection Yes, Power Supply 12V (DC); 802.3af (PoE), Power Consumption Approximately 7W, Operating Humidity Less than 95% RH (non-condensing), Operating Temperature -30°C to 60°C,Storage NAS, SD Card, BIS, CE, IP67, FCC Part-15 Subpart – B, ONVIF S, G & T, IK10, UL, NEMA 4X**,- complete in all respect as desired by the engineer in charge at site. |
| 230 | SUPPLY & ERECTION OF 16 Channel IP INPUT 12MP NVR 4K with 4 SATA having following features:- Up to 32 Channel Input, 4 Sata Interfaces, Up To 12TB each, H.265/H.264 Video Formats, 1 HDMI Port , USB2.0*1, USB2.0*2 Support,2×RJ45 Self-adaptive 10/100/1000 Mbps Network Interfaces, Supports live view, storage and playback of the connected camera at up to 12MP resolution, Connectable to the Third Party Network Cameras, Incoming Bandwidth -200M, Outgoing Bandwidth-200M, Recording Resolution-12 MP/8 MP/5 MP/4 MP/3 MP/1080p/720p, Recording Compression, Audio: G.711a,G.711u, Video : H.264/H.265, H.264+/H.265+, Speed -12MP:30fps 8MP:120fps 4MP:240fps 2MP:480fps, Playback- 1080P:480fps Max 16CH, WEB -IE10/11, Safari V12.1 above, Firefox V.52 above, Google chrome V.57 above, Edge V.79 above, Protocols-TCP/IP, DHCP, IPv4, IPv6, DNS, DDNS, NTP, RTSP, SADP, SMTP, SNMP, UPnP, HTTP, HTTPS, API -Onvif (profile S/G/T HDMI -1(1024*768, 1280*720, 1280*1024, 1440*900, 1920*1080, 2560*1440(2K), 3840*2160(4K)) 0 /EDID) Async out, Ethernet-2 RJ45 100/1000 Base-T USB USB2.0*1(front), USB 2.0 *1 USB 2.0 *1 (rear), Audio-1 in / 1 out, E-sata-1 ,HDD 4, each up to 12TB, OSD Language English, Input Voltage/ Current 12V/5A, Power consumption (excluding hard disk) -8WOperating Temperature/Humidity-Temperature :-10°C~+50°C (14°F ~ 122°F) Humidity : Less than 90%RH complete in all respect as desired by the engineer in charge at site. |
| 231 | SUPPLY & ERECTION of 6000GB Audio Video HDD 3.5 Inches Connector SATA, Interface SATA, Operating Temperature 0°C to 65°C, Transfer Rate minimum 160MB/s, Recording Technology – CMR, Certifications BSMI, ICES-003/NMB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL for NVR recording and playback complete in all respect as desired by the engineer in charge at site. |
| 232 | SITC of 24 Port POE 190+ Watts L2 managed 10/100/1000 Mbps with 4 No Uplinks RJ45 and SFP Combo 1G Ports Data switch with 4 • IEEE 802.3u 100BASE-TX Fast Ethernet• IEEE 802.3ab 1000BASE-T Gigabit Ethernet• IEEE 802.3az Energy-Efficient Ethernet (EEE)• ANSI/IEEE 802.3 NWay auto-negotiation• IEEE 802.3x Flow Control, Standards • IEEE 802.3 10BASE-T Ethernet Switching Fabric • 30 Gbps Data Transfer Rates • Gigabit Ethernet • 1000 Mbps (full-duplex) • Fast Ethernet • 100 Mbps (half-duplex) • 200 Mbps (full-duplex)• Ethernet • 10 Mbps (half-duplex)• 20 Mbps (full-duplex), PoE Standards • IEEE 802.3af • IEEE 802.3at PoE-capable Ports • Ports 1 to 4 Power 60W • 190+ W (30 W max. per PoE port). CPU RAM 256MB or above, Certification - FCC class A, CE class A, VCCI, BSMI, CCC, CE, LVD, UL, CB Oper Temp- -5 to 50 °C (23 to 122 °F) complete in all respect as desired by the engineer in charge at site. |
| 233 | SITC of 24 Port L2 managed 10/100/1000 Mbps with 4 No Uplinks RJ45 and SFP Combo 1G Ports Data switch with 4 • IEEE 802.3u 100BASE-TX Fast Ethernet• IEEE 802.3ab 1000BASE-T Gigabit Ethernet• IEEE 802.3az Energy-Efficient Ethernet (EEE)• ANSI/IEEE 802.3 NWay auto-negotiation• IEEE 802.3x Flow Control, Standards • IEEE 802.3 10BASE-T Ethernet Switching Fabric • 30 Gbps Data Transfer Rates • Gigabit Ethernet • 2000 Mbps (full-duplex) • Fast Ethernet • 100 Mbps (half-duplex) • 200 Mbps (full-duplex)• Ethernet • 10 Mbps (half-duplex)• 20 Mbps (full-duplex), PoE Standards • IEEE 802.3af •. CPU RAM 256MB or above, Certification - FCC class A, CE class A, VCCI, BSMI, CCC, CE, LVD, UL, CB Oper Temp- -5 to 50 °C (23 to 122 °F complete in all respect as desired by the engineer in charge at site. |
| 234 | Supply & erection of Smart 55” LED Commercial Panel /Regular with 2 HDMI Port, TV Input, 3 Years Warranty, 2 HDMI Port, TV Input, 3 Years Warranty, Resolution 4K, Brightness 300 cd/m2 Support 4K Ultra HD 20 Watt 2.0 Audio Output Web Browser Soft AP, WiFi (bandwidth) Screen Share (Miracast) Samsung TV Plus App USB Cloning, 2 No. Of HDMI Port 2 no USB Port complete in all respect as desired by the engineer in charge at site. |
| 235 | Supply & erection of 10 meter long superior quality 4K HDMI Cable having speed upto 10gbps support all types of HDMI Devices complete in all respect as desired by the engineer in charge at site. |
| 236 | Supply & erection of RJ-45 Male connector complete in all respect as desired by the engineer in charge at site. |
| 237 | Supply & erection of 24 port Loaded patch Panel complete in all respect as desired by the engineer in charge at site. |
| 238 | Supply & erection of 1 Meter Patch Cord complete in all respect as desired by the engineer in charge at site |
| 239 | Supply & erection of 2 Meter Patch Cord complete in all respect as desired by the engineer in charge at site. |
| 240 | Supply & erection of 12U Wall mount 19’’ Rack with glass door,lock & key facility 400/450/500mm depth AC Fan having 10 no. mounting hardware, Cable entry/exit provision at top and bottom panels, Ventilation slots on top, bottom and side panels, Fixed side panels, Comply IS Standard of Racks. complete in all respect as desired by the engineer in charge at site. |
| 241 | Supply & erection of 1000VA LIT UPS/ Power Plant with SMF batteries having 30 Minutes backup time, Cold Start, 3 No. plug Indian style, Automatic Voltage Controller, Overload protection, Over charging Protection, 2 No. 12v 7Ah Batteries, Wide Input Range, Fan Less Cooling system, Transfer time less than 8ms,Audible Alarm etc. complete in all respect as desired by the engineer in charge at site. |
| 242 | 3-STEPPED STEEL TUBULAR POLE:Supply and erection of 3-Stepped steel tubular swaged and welded pole (410-SP-Mpa) of suitable length confirming to IS: 2713- (PART-II)-1980 (Steel tubes confirming to IS: 1161-1979, UTS 42 kgf/ Sq.mm) to fix on precast RCC column of suitable dimensions. The bottom section shall have openable slot with exterior surface door & shall have suitable locking arrangement for housing three phase 4wire cable connection, bakelite sheet, MCB, loop in and out arrangement for incoming/ outgoing cables. There shall be suitable arrangement for earthing. Rigid Base plate of suitable size and thickness shall be welded inside and outside at the bottom of pole with provision for fixing 4 foundation bolts. The steel tubular pole shall be bolted on a pre- cast foundation with a set of four foundation bolts for greater rigidity. The foundation shall be erected over cement concrete M20 with steel of given size as per design of original pole manufacturer to fixed up to a required planting depth below ground level including painting of pole with two coats of approved aluminium paint as required:-Overall length 7 metre, length of sections 4 metre, 1.5 metre and 1.5 metre (Bottom, Middle and Top respectively), Outer dia and thickness of sections 114.3mm x 4.5mm, 88.9mm x 4.05mm and 76.1mm x 3.25mm (Bottom, Middle and Top respectively) with approximate weight 73 kg. (410 SP-2), Foundation size below G/L 550mm x 550mm x 1400mm, 4Nos. Foundation Bolts size 20mm dia., Length≥700mm with Base Plate Dimensions 240mm x 240mm x 16mm Thick (approx. weight 7.235 kg.) |
| 243 | SINGLE/ DOUBLE/ TRIPLE/ FOUR/ SIX ARMS BRACKET FOR STEEL TUBULAR POLE:Supply and erection of G.I. Pipe 50mm dia. (Medium) Single/ Double/ Triple arm bracket of suitable length welded with MS canopy 80mm inner dia., outer dia 89.5mm (Medium), 450mm long suitable for 3 stepped steel tubular swaged and welded pole with top outer section dia. 76.1mm. The MS canopy should have 3no. holes for fixing the bracket at the top end of the pole with the help of 3Nos. ½\\" x 1½\\" size nut bolt fully threaded. The bracket should have MS sheet (1.62mm thick) ring of 89.5mm dia. for covering the top end of the canopy. The MS canopy and GI bracket should be welded at tentative angle 105º (105 degree) inclination with MS sheet 5mm thick triangular in shape having dimensions 225/300/375mm x 150mm x 5mm thick (225mm for 1.5m, 300mm for 2m & 375mm for 2.5m long bracket) with two coats of an approved aluminium paint as desired by Engineer-in-charge at site:-Single Arm Bracket 1 metre Long for Steel Tubular Pole (7 to 8m) |
| 244 | Supply and erection of LED Street Light 45 watt New Generation enery saving and environmental friendly long life LED Street light made up of pressure die cast aluminium housing with high effciency LED's lighting source and lens embedded PC COVER HAVING top opening seperate driver compartment with IP66 Protection and impact resistance of IK07, complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021.Beside this the lighting manufacturer should have inhouse NABL accreted Lab. |
| 245 | XLPE INSULATED UN-ARMOURED CABLES (LOOSE):-Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-Overall size 10sq.mm (2Core) Un-armoured (Loose) |
| 246 | DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- Double walled corrugated (DWC) HDPE pipe 50/38mm (outer/ inner dia.) |
| 247 | GALVANIZED IRON PIPES AND G.I. EARTHING:Earthing with G.I. wire/ rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. to make a mesh around the GI Pipe) with G.I. reducing socket including erection of the same, 4.50 metre (14.76 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 8 metre in length (including boring & refilling).Earthing with 8 S.W.G. (4mm dia.) G.I. wire in 15mm dia G.I. pipe with G.I. reducing socket 50mm x 15mm (upto 8Metre in length) |
| 248 | Additional length G.I. wire 8 S.W.G. (4mm dia.) in 15mm dia. G.I. pipe (On Surface) |
| 249 | Earthing earth rod 20 mm dia for providing earth connections upto line earth with G.I. Wire 8 S.W.G. (4mm dia.). The rod shall be tapered at one end and flatted on other end. The hole size 10mm dia shall be drilled on the flatened side for facilitating connection with G.I. wire and thimble etc. The rod shall be erected in ground upto complete length vertically:-GI Earth rod 20 mm dia. 3 mtr. Long |
| 250 | PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE:Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- Overall size 1.5sq.mm (Un-sheathed) |
| 251 | MINIATURE CIRCUIT BREAKERS/ RCBO's/ RCCB's:Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-MCB Double Pole 6-32amp. (10kA, Curve-C) |
| 252 | SHEET METAL CUBICAL PEDESTAL, TOWER STRUCTURES, HT & LT LINE ITEMS, MS CHANNELS, BRASS GLANDS, ALUMINIUM & COPPER THIMBLES:CUBICAL PEDESTAL: Supply and erection of Sheet metal cubical pedestal made from 50mmx50mmx6mm thick MS angle iron frame with 5 sides welded & covered with MS sheet 2mm thick & front side hinged with 4\\" hinges & locking system with single/ double door openable placed on MS strip of size 12.5mm x 2.5mm thick welded with MS sheet, 4Nos. legs of 50mmx50mmx6mm thick MS angle iron each of 600mm long with MS sheet 100mmx100mmx6mm thick at the bottom end of the legs. Front door welded x-sectionally with MS flat 25mmx5mm. The front side with MS sheet each 75mm wide & a bend of 75mm width outwards & inwards on all sides with tappered top 200mm high and pedestal with 4 Nos. supporting members each of MS flat 50mmx6mm thick according to cubical size duly welded & complete pedestal to be painted with 1 coat of red oxide & 2 coats of paint & bonding to the existing earth. The Pedestal platform should be filled with 1:2:4 cement concrete mixture and erected 150mm high from the top of the cement concrete platform. The job is to be completed as approved by Engineer-in-charge:-Cubical Size 900mm high, 600mm wide and 350mm deep with platform dimensions 700mm x 450mm x 450mm |
| 253 | S/E of Microprocessor Based Street Light Controller with digital time switch daily programmed with stand by lithium battery with back up of 6 years with min. time between 2 switching operations is 1 minute, three pole power contactors 40A. with coil voltage 220-230V AC with 1 no. aux. contact NO, MCB 2 pole 40amp. (C-Curve, 10kA) & power wiring with single core PVC insulated FR cable 10 sq. mm and control wiring with PVC insulated FR cable 1 sq. mm, 1 no. two position selector switch to bypass timer and other accessories & petty material (din rail, 4 pole bakelite terminal strip 63A/ 440V AC, required nut bolts) should be fixed on bakelite sheet 6mm thick to be mounted in a IP54 surface/ flush mounting powder coated sheet metal (1.60mm thick) cabinet having size 450mm x 600mm x 150mm to switch ‘ON’ all the 3 phases & switch ‘OFF’ 3 phases pre-fixed timings complete in all respect as per satisfaction of Engineer-in-charge:-Street Light Controller (For Three Single Phase Circuits) with 3 Nos. Three Pole Power Contactors 40A, 1 no. aux. contactor 6 amp. (2NO+2NC) with coil voltage 220V AC, 3 Nos. MCB 2 Pole 40amp. (C-Curve,10kA) & petty material (Din rail, 2 Nos. 4 pole bakelite terminal strip 63A/ 440V AC, required nut bolts) |
| 254 | SWITCH DISCONNECTOR FUSE UNIT (With Sheet Enclosure):- Supply and erection of Switch Disconnector Fuse Unit with HRC Fuses (Suitable for DIN HRC Fuses) in sheet enclosure on the existing surface Confirms to IS 13947 (Part-III), IEC 60947-3 complete with G.I. Bolts, Nuts & Connections on both sides of switch with suitable size of thimbles, including cost of DIN HRC fuses as per PWD General Specifications:-SDF TP&N 32Amp., 415volts (With Sheet Enclosure) |
| 255 | Solar Power Generation System:Supply, Installation, testing & Commissioning of Grid interactive PV System Solar Power Plant (i.e connected to utility grid) of Minimum 100KW including required quantities of SPV modules (High power density Monocrystalline based single module of capacity +400 watt) formed into arrays, their mounting arrangement, Power conditioning units (i.e String Solar Inverter with 2Nos. GI Chemical earthing with suitable size GI strip upto string inverter and AC & DC distribution panel), required DC & AC distribution panels with surge protection units, cabling from terrace to main distribution board through Cable tray, Bi Directional Energy Meter, Provision of Lightening Arrestor & 2 Nos. GI chemical earthing with suitable size GI strip upto Lightning arrestor, Hot dip galvanized MS Mounting Structures (1No. GI Chemical earthing with suitable size GI strip upto mounting structure) should be designed to withstand the speed for the wind Zone of the location (150 Km/hr-170 Km/hr) Complete in all respect with transportation, fabrication, labour & Civil Work etc.Features :-Solar PV Module warranty 25 Years & certified under IS/IEC 61730 I & II IS/IEC 61701 & IS/EC 14286Power Conditioning unit (string solar inverter) & certified under IEC/EN 62109-1, IEC/EN 62109-2, EN 61000-6-2, EN 61000-6-3, IEC 61683, EN 50530, IEC 60068-2-1, 2, 14, 30, EN 60529Structure 25 Years service life with AMC & certified under IS 2062 2011Complete Plant insurance for the period of 5 Years (Excluding Theft of the Material)Annual Maintenance contract for the period of 10 Years Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 02, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 16, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysNov 17, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender