Tender For Repair & Maintenance Of Lt Panels, Switch Gear & All Types Of Switch Gear Earthing, Painting Of Poles And Replacement Of Over Head To Lt Ug Cables Etc Zone C & D At Bkp Under Ge Bkp
Tender Value
44.99 Lakhs
Estimated cost
Bid Submission
21 Nov 2026
17 days left
EMD
89980
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
24 Paraganas North → West Bengal
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair & Maintenance Of Lt Panels, Switch Gear & All Types Of Switch Gear Earthing, Painting Of Poles And Replacement Of Over Head To Lt Ug Cables Etc Zone C & D At Bkp Under Ge Bkp
BOQ
| Sl. No. | Item Description |
| 1 | M & L for disconnecting the electric connection and dismantling to the existing old LT panel board of any size and keeping aside in safe custody / depositing to MES store yard including its accessories as schedule of credit to contractor or as directed by Engineer-in-Charge. |
| 2 | S&F LT Bus bar chamber Outdoor/floor mounted suitable for 415V 3 phase 4 wire 50 Hz AC Supply system busbar capacity 200A as specified. The panel should be powder coated paint for better environmental protection, made of CRCA sheet steel 3.15 mm having RYB indicating lamp and multifunctional meter for ampere and voltage rating including making of foundation of the panel ,lugs and gland of suitable size ,Fixing and connection Included complete all as specified and as directed. |
| 3 | All as per item No 2 here in before but busbar capacity 400 A complete all as specified and as directed. |
| 4 | M& L for disconnecting all XLPE cables from panel and carry out preventive Repair/Replacement of unserviceable existing wiring of LT Panel/APFC Panel, cleaning of bus bar with CRC spray and wiring with new copper wiring 2.5/4 sqmm with copper/aluminium lugs, replacing burnt epoxy insulator bar and insulating the bus bar with tape conforming with colour code and reconnecting all cables complete all as specified and as directed.Notes: - (i) Necessary repairs parts like cable, Copper lugs/thimbles DMC resin/Red polyamide type, Epoxy insulator, bus bar connector/supporter of suitable size/dimension, panel locker, rubber gasket, handle, cable gland etc shall be measured & paid separately as 'Supply Only' under relevant item. |
| 5 | Supply only 2.5 sqmm single core sheathed copper cable complete all as specified and as directed. |
| 6 | Supply only 4 sqmm single core sheathed copper cable complete all as specified and as directed. |
| 7 | Supply only 6 sqmm single core sheathed copper cable complete all as specified and as directed. |
| 8 | Supply only Copper lugs/thimbles of size 2.5 to 10 sqmm complete all as specified and as directed. |
| 9 | Supply only DMC resin/Red polyamide type Epoxy insulator bus bar connector/supporter of suitable size/dimension complete all as specified and as directed. |
| 10 | Supply only LT Panel Locking set complete all as specified and as directed. |
| 11 | Supply only EPDM Rubber gasket for door sealing complete all as specified and as directed. |
| 12 | Supply only Fire retardant PU Foam insulation sealant can 750ml for sealing cable entry using spray gun of \\"B2 Fire class DIN 4201-1 complete all as specified and as directed. |
| 13 | Supply only PVC Grommet of suitable size at cable entry complete all as specified and as directed. |
| 14 | Supply only LT Panel Handle set complete all as specified and as directed. |
| 15 | Supply only Cable glands upto 1\\" dia complete all as specified and as directed. |
| 16 | Supply only Cable glands upto 2\\" dia complete all as specified and as directed. |
| 17 | S&F in repairs, 3 Ph ammeter digital type display 0-500A range square shape witch CT Coil fixed to existing LT Panels complete all as specified and as directed. |
| 18 | S&F in repairs, 3 Ph Voltmeter digital type display 0-500V range square shape with PT Coil fixed to existing LT Panels complete all as specified and as directed. |
| 19 | M & L for complete Painting of LT Panels of frontal size less than one square meter by complete removal of old painted surfaces, cleaning refixing panel board door with hinges, nut bolts etc removing of existing rust grease oil spot etc, priming with red-oxide zinc chrome primer and then applying 1st grade of synthetic enamelled spray paint (two coats) of approved make, brand and colours included foundation and writing names of the distribution location complete all as specified and as directed by Engineer-in-Charge. |
| 20 | All as per item No 19 here in before but frontal size more than one square meter complete all as specified and as directed. |
| 21 | Excavation in trenches not exc 1.50 m wide and not exc 1.50 m deep for foundation, laying of pipe or for shafts, wells cesspits, man holes, pier holes, laying of cable etc not exc 10 Sqm on plan and n exc 1.5m in depth and getting out in soft / loose soil complete all as specified and as directed. |
| 22 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc. 25 cm in soft / loose soil complete all as specified and as directed. |
| 23 | Removing excavated soil to distance not exc. 50 m and depositing where directed at a level not exc. 1.5 m above the starting point etc complete all as specified and as directed. |
| 24 | Supply, laying and testing XLPE Insulated , PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 4 sqmm 2 core laid in trenches /floor or fixed on wall/pole in existing or new location including brass compression cable glands, terminal lugs etc,including dismantling of old cable of any description complete all as specified and as directed. |
| 25 | Supply, laying and testing XLPE Insulated , PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 10 sqmm 2 core laid in trenches /floor or fixed on wall/pole in existing or new location including brass compression cable glands, terminal lugs etc,including dismantling of old cable of any description complete all as specified and as directed. |
| 26 | Supply, laying and testing XLPE Insulated , PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 25 sqmm 4 core laid in trenches /floor or fixed on wall/pole in existing or new location including brass compression cable glands, terminal lugs etc,including dismantling of old cable of any description complete all as specified and as directed. |
| 27 | Supply, laying and testing XLPE Insulated , PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 35 sqmm 3.5 core laid in trenches /floor or fixed on wall/pole in existing or new location including brass compression cable glands, terminal lugs etc,including dismantling of old cable of any description complete all as specified and as directed. |
| 28 | M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 50 sqmm 3.5 core laid in trenches /floor or fixed on wall /pole in including brass compression cable glands, terminal lugs etc, including dismantling of old cable of any description complete all as specified and as directed. |
| 29 | M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 120 sqmm 3.5 core laid in trenches /floor or fixed on wall /pole in including brass compression cable glands, terminal lugs etc, including dismantling of old cable of any description complete all as specified and as directed. |
| 30 | M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 150 sqmm 3.5 core laid in trenches /floor or fixed on wall /pole in including brass compression cable glands, terminal lugs etc, including dismantling of old cable of any description complete all as specified and as directed. |
| 31 | M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 240 sqmm 3.5 core laid in trenches /floor or fixed on wall /pole in including brass compression cable glands, terminal lugs etc, including dismantling of old cable of any description complete all as specified and as directed. |
| 32 | M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 400 sqmm 3.5 core laid in trenches /floor or fixed on wall /pole in including brass compression cable glands, terminal lugs etc, including dismantling of old cable of any description complete all as specified and as directed. |
| 33 | M&L for sand cushioning with dry river sand in trenches for cushioning of underground cable including spreading, leveling, punning down the thickness of sand upto 18cm and consolidated complete all as specified and as directed. Note: Punned thickness of sand cushioning will be measured and paid. |
| 34 | M&L for sub class ‘B’ old size well burnt brick laid flat in trenches with length of brick perpendicular to length of cable, over the cable for protection of LT cable complete all as specified and as directed. |
| 35 | Supply and laying GI tubing 50mm bore light grade with fittings laid in trenches, on pole and road crossing for protection of LT underground cables complete all as specified and as directed. |
| 36 | M&L for boring of hole under roads with mechanical arrangement upto 80 mm dia without disturbing the top surface of the road for passing the cable across the road complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 37 | M&L for boring of hole under roads with mechanical arrangement upto 80 mm dia without disturbing the top surface of the road for passing the cable across the road complete all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 31, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 21, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 17 daysNov 23, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender