Defence Statutory Bodies & Commissions/Committees Closing in 17 days TDR #58325833

Tender For Repair & Maintenance Of Lt Panels, Switch Gear & All Types Of Switch Gear Earthing, Painting Of Poles And Replacement Of Over Head To Lt Ug Cables Etc Zone C & D At Bkp Under Ge Bkp

Issued by Statutory Bodies & Commissions/Committees · 24 Paraganas North, West Bengal
Tender Value
44.99 Lakhs
Estimated cost
Bid Submission
21 Nov 2026
17 days left
EMD
89980
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
24 Paraganas North → West Bengal
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair & Maintenance Of Lt Panels, Switch Gear & All Types Of Switch Gear Earthing, Painting Of Poles And Replacement Of Over Head To Lt Ug Cables Etc Zone C & D At Bkp Under Ge Bkp

BOQ

Name of Work:- REPAIR & MAINT OF LT PANELS, SWITCH GEAR & ALL TYPES OF SWITCH GEAR EARTHING, PAINTING OF POLES AND REPLACEMENT OF OVER HEAD TO LT UG CABLES ETC ZONE C & D AT BKP UNDER GE BKP
Sl. No. Item Description
1M & L for disconnecting the electric connection and dismantling to the existing old LT panel board of any size and keeping aside in safe custody / depositing to MES store yard including its accessories as schedule of credit to contractor or as directed by Engineer-in-Charge.
2S&F LT Bus bar chamber Outdoor/floor mounted suitable for 415V 3 phase 4 wire 50 Hz AC Supply system busbar capacity 200A as specified. The panel should be powder coated paint for better environmental protection, made of CRCA sheet steel 3.15 mm having RYB indicating lamp and multifunctional meter for ampere and voltage rating including making of foundation of the panel ,lugs and gland of suitable size ,Fixing and connection Included complete all as specified and as directed.
3All as per item No 2 here in before but busbar capacity 400 A complete all as specified and as directed.
4M& L for disconnecting all XLPE cables from panel and carry out preventive Repair/Replacement of unserviceable existing wiring of LT Panel/APFC Panel, cleaning of bus bar with CRC spray and wiring with new copper wiring 2.5/4 sqmm with copper/aluminium lugs, replacing burnt epoxy insulator bar and insulating the bus bar with tape conforming with colour code and reconnecting all cables complete all as specified and as directed.Notes: - (i) Necessary repairs parts like cable, Copper lugs/thimbles DMC resin/Red polyamide type, Epoxy insulator, bus bar connector/supporter of suitable size/dimension, panel locker, rubber gasket, handle, cable gland etc shall be measured & paid separately as 'Supply Only' under relevant item.
5Supply only 2.5 sqmm single core sheathed copper cable complete all as specified and as directed.
6Supply only 4 sqmm single core sheathed copper cable complete all as specified and as directed.
7Supply only 6 sqmm single core sheathed copper cable complete all as specified and as directed.
8Supply only Copper lugs/thimbles of size 2.5 to 10 sqmm complete all as specified and as directed.
9Supply only DMC resin/Red polyamide type Epoxy insulator bus bar connector/supporter of suitable size/dimension complete all as specified and as directed.
10Supply only LT Panel Locking set complete all as specified and as directed.
11Supply only EPDM Rubber gasket for door sealing complete all as specified and as directed.
12Supply only Fire retardant PU Foam insulation sealant can 750ml for sealing cable entry using spray gun of \\"B2 Fire class DIN 4201-1 complete all as specified and as directed.
13Supply only PVC Grommet of suitable size at cable entry complete all as specified and as directed.
14Supply only LT Panel Handle set complete all as specified and as directed.
15Supply only Cable glands upto 1\\" dia complete all as specified and as directed.
16Supply only Cable glands upto 2\\" dia complete all as specified and as directed.
17S&F in repairs, 3 Ph ammeter digital type display 0-500A range square shape witch CT Coil fixed to existing LT Panels complete all as specified and as directed.
18S&F in repairs, 3 Ph Voltmeter digital type display 0-500V range square shape with PT Coil fixed to existing LT Panels complete all as specified and as directed.
19M & L for complete Painting of LT Panels of frontal size less than one square meter by complete removal of old painted surfaces, cleaning refixing panel board door with hinges, nut bolts etc removing of existing rust grease oil spot etc, priming with red-oxide zinc chrome primer and then applying 1st grade of synthetic enamelled spray paint (two coats) of approved make, brand and colours included foundation and writing names of the distribution location complete all as specified and as directed by Engineer-in-Charge.
20All as per item No 19 here in before but frontal size more than one square meter complete all as specified and as directed.
21Excavation in trenches not exc 1.50 m wide and not exc 1.50 m deep for foundation, laying of pipe or for shafts, wells cesspits, man holes, pier holes, laying of cable etc not exc 10 Sqm on plan and n exc 1.5m in depth and getting out in soft / loose soil complete all as specified and as directed.
22Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc. 25 cm in soft / loose soil complete all as specified and as directed.
23Removing excavated soil to distance not exc. 50 m and depositing where directed at a level not exc. 1.5 m above the starting point etc complete all as specified and as directed.
24Supply, laying and testing XLPE Insulated , PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 4 sqmm 2 core laid in trenches /floor or fixed on wall/pole in existing or new location including brass compression cable glands, terminal lugs etc,including dismantling of old cable of any description complete all as specified and as directed.
25Supply, laying and testing XLPE Insulated , PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 10 sqmm 2 core laid in trenches /floor or fixed on wall/pole in existing or new location including brass compression cable glands, terminal lugs etc,including dismantling of old cable of any description complete all as specified and as directed.
26Supply, laying and testing XLPE Insulated , PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 25 sqmm 4 core laid in trenches /floor or fixed on wall/pole in existing or new location including brass compression cable glands, terminal lugs etc,including dismantling of old cable of any description complete all as specified and as directed.
27Supply, laying and testing XLPE Insulated , PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 35 sqmm 3.5 core laid in trenches /floor or fixed on wall/pole in existing or new location including brass compression cable glands, terminal lugs etc,including dismantling of old cable of any description complete all as specified and as directed.
28M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 50 sqmm 3.5 core laid in trenches /floor or fixed on wall /pole in including brass compression cable glands, terminal lugs etc, including dismantling of old cable of any description complete all as specified and as directed.
29M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 120 sqmm 3.5 core laid in trenches /floor or fixed on wall /pole in including brass compression cable glands, terminal lugs etc, including dismantling of old cable of any description complete all as specified and as directed.
30M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 150 sqmm 3.5 core laid in trenches /floor or fixed on wall /pole in including brass compression cable glands, terminal lugs etc, including dismantling of old cable of any description complete all as specified and as directed.
31M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 240 sqmm 3.5 core laid in trenches /floor or fixed on wall /pole in including brass compression cable glands, terminal lugs etc, including dismantling of old cable of any description complete all as specified and as directed.
32M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 400 sqmm 3.5 core laid in trenches /floor or fixed on wall /pole in including brass compression cable glands, terminal lugs etc, including dismantling of old cable of any description complete all as specified and as directed.
33M&L for sand cushioning with dry river sand in trenches for cushioning of underground cable including spreading, leveling, punning down the thickness of sand upto 18cm and consolidated complete all as specified and as directed. Note: Punned thickness of sand cushioning will be measured and paid.
34M&L for sub class ‘B’ old size well burnt brick laid flat in trenches with length of brick perpendicular to length of cable, over the cable for protection of LT cable complete all as specified and as directed.
35Supply and laying GI tubing 50mm bore light grade with fittings laid in trenches, on pole and road crossing for protection of LT underground cables complete all as specified and as directed.
36M&L for boring of hole under roads with mechanical arrangement upto 80 mm dia without disturbing the top surface of the road for passing the cable across the road complete all as specified and as directed. Please Enable Macros to View BoQ information
37M&L for boring of hole under roads with mechanical arrangement upto 80 mm dia without disturbing the top surface of the road for passing the cable across the road complete all as specified and as directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58325833
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 44.99 Lakhs
LAST DATE 21-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair & Maintenance Of Lt Panels, Switch Gear & All Types Of Switch Gear Earthing, Painting Of Poles And Replacement Of Over Head To Lt Ug Cables Etc Zone C & D At Bkp Under Ge Bkp
Basic Detail
Tender No 8316/E8
Bidding Type Tender
Location
City 24 Paraganas North
State West Bengal
Key Dates
Publish Date 31 Oct 2026
Submission Date 21 Nov 2026
Open Date 23 Nov 2026
Finance
Tender Value 44.99 Lakhs
Tender Fee 500
EMD 89980
Exemption Available
Document List
a058e25a-711c-489e-8d33-da11327e2a14.html
BOQ_893754.xls
Tenderdoc_8316.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 31, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 17 days
Nov 23, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 19 days

Tender Documents

Download All (ZIP) ↓
html

a058e25a-711c-489e-8d33-da11327e2a14.html

xls

BOQ_893754.xls

pdf

Tenderdoc_8316.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender