Power Boards / Undertakings / PSU Closing in 22 days TDR #58323510

Tender For Turnkey Construction 132Kv Feeder Bays At Both Ends Including Associated Works For 132Kv Iocl Bgr 2Nd Circuit Line From 132Kv Dhaligaon Gss To Iocl Bongaigaon Refinery

Issued by Boards / Undertakings / PSU · Chirang, Assam
Tender Value
10.50 Crore
Estimated cost
Bid Submission
25 Nov 2026
22 days left
EMD
21 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chirang → Assam
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Turnkey Construction 132Kv Feeder Bays At Both Ends Including Associated Works For 132Kv Iocl Bgr 2Nd Circuit Line From 132Kv Dhaligaon Gss To Iocl Bongaigaon Refinery

BOQ

Name of Work:- Turnkey Construction 132kV Feeder Bays at both ends including associated Works for 132KV IOCL BGR 2nd Circuit Line from 132KV Dhaligaon GSS to IOCL Bongaigaon Refinery
Sl. No. Item Description
1Supply of Circuit Breaker with mounting structure, terminal connectors etc as required and as per specifications
2132 KV Gang operated SF6 Circuit Breaker
3Supply of Current transformer along with terminal connectors etc. as required and as per specifications
4132 KV 400-200-100/1-1-1-1A Line CT
5132 KV 400-200-100/1-1A metering CT
6Supply of Isolators along with insulators, terminal connectors etc. as required as per specifications
7132 KV Isolator without Earth Switch (HCB type)
8132 KV Isolator with Earth Switch (HCB type)
9Supply of Lightening arrestors
10132 KV ZnO type Lightneing Arrestor with terminal connectors etc. as per specifocations
11Supply of Post Insulators
12132 KV Post insultaor with terminal connectors as per specifications
13Supply of Potential Transformer
14132 KV/110/√3-110/√3 V Potential Transformer 2 core with terminal connectors etc. as per specifications
15Supply of CVT
16132 KV, 4400 pf Capacitive Voltage Transformer 4 core with terminal connectors etc as per specifications
17Relay and Control Panel
18Control and relay panel with Automation (Simplex Type) with BCU, ethernet switch, line differential relay with distance as backup and AT meter with cubicle and all accessories as required as per specification for SAS integration into existing SAS (Existing SAS is of Hitachi make)
19Mounting Structures
20For CT
21For Isolators with earth switch
22For Isolators without earth switch
23For LA
24For PT
25For CVT
26For PI
27Supply of Column
28Column Type C8(6 Nos)(2111.32kgs/Coloumn)
29Column Type C2(2 Nos)(623.01Kgs/Column)
30Supply of Beam
31Beam Type B2X(4 Nos. )(756.84 kgs/Beam)
32Beam B1( 2 Nos)(717.2 kgs/Beam
33Tower Bolts and Nuts
34Foundation Bolts and Nuts
35Power Cable (Al Core, armoured)
364C, 6 Sqmm
374C, 16 Sqmm
38Control Cable (Cu Core, armoured)
394C, 2.5 Sqmm
409C, 2.5 Sqmm
4119C, 2.5 Sqmm
42Supply of Power Conductor
43HTLS ACCC Drake Conductor for 132kV Main Bus
44ACSR Zebra Conductor for 132kV Transfer Bus
45Disc insulators and hardware accessories
4610 Disc Tension Insulator String (120kN Disc Insulator
479 Disc Suspension Insulator String (90 kN Disc Insulatorr
48Supply of earthing materials
49Main Earth Mat (75 mm x 12 mm GI Flat)
5075 mm x 12 mm GI Flat for raiser, equipment/structure earthing
5150 mm x 6 mm GI Flat for equipment earthing
5240 mm dia, 3 mtr MS Rod Electrode with test link for each tower, LAs CVTs, etc.
53Aux Earth Mat
5450 mm x 6 mm GI Flat for indoor panel earthing
55Shield Wire
567/3.66 mm GI shield wire
57Clamps and Connectors for GI shield wire
58Bay marshalling kiosk with mounting structure and rain shed painted as per site requirement
59Clamps and Connectors for power conductor
60Supply of single tension string assembly with turn buckle though clamp suitable to offered single HTLS conductor
61Supply of single tension string assembly without turn buckle though clamp suitable to offered single HTLS conductor
62Supply of Single suspension string assembly without tun buckle through clamp suitable to offered single HTLS conductor
63supply of T-Clamp to suit offered single HTLS to Single ACSR Zebra
64Supply of Single tension hardware fittings for ACSR Zebra Conductor including all accessories.(120kN Disc Insulator
65Supply of Single suspension hardware fittings for ACSR Zebra Conductor including all accessories.(90 kN Disc Insulator
66Supply of ACDB and DCDB
67Supply of 415 V ACDB as per specifications
68Supply of 110 V DCDB as per specifications
69FO Cables and accessories
70Armoured FO Cable (12 Fibre)
71Line Inteface Unit
72Supply of energy meter
73ABT compliant energy meter with cubicle as per APDCL specifications
74Switchyard Illumination
75Supply of 200 W LED (20nos.) with fittings and accessories, distribution box, MCB, switches , sockets, Cables as required and specified.
76Fire Fighting equipments
77DCP type fire extinguisher Cylinder (25 KG), trolley mounted
78CO2 type fire extinguisher cylinder (6.5 Kg)
79Mandatory spares for 132 KV Circuit Breaker
80Interrupter
81Tripping Coil
82Closing Coil
83Spring charging motor
84Set of all types of gaskets with sealing agent
85Circuit Breaker operating mechanism with all fittings
86Mandatory spares for Relay and Control Panel
87Over curent Relay
88Earth Fault Relay
89Line Differential Relay
90Master Trip Relay
91Trip Circuit Supervision Relay
92Ethernet Switch
93OFC Patch Cord (15 m) with end termination ready
94Spare Isolator with insulators,terminal connectors,structures complete as per specification
95132kV Without Earth Switch
96Mandatory spare
97Complete CT Terminal connector set
98Complete CVT Terminal connector set and stool structure
99132kV LA with terminal connector (spare)
100Clamps and connectors
101PG Clamp with connectors and all hardware fittings suitable for ACSR Zebra conductor
102T-Clamp and Connectors and all hardware fittings suitable for ACSR Zebra Conductor
103TEE Connector Rigid through type alongwith all hardware fittings for 132kV LA and suitable for ACSR Zebra conductor
104TEE Connector Rigid through type alongwith all hardware fittings for 132kV CVT and suitable for ACSR Zebra conductor
105Air Conditioning
106Supply of heavy duty Industrial grade AC as per specification for the kiosk building (Including erection)
107Supply of testing equipments
108Digital Earth Tester
109Miscellneous
11012 KG SF6 gas Cylinder
111SF6 Gas density monitoring device
112Discharge Rods
113Bay Markers
114Supply of Circuit Breaker with mounting structure, terminal connectors etc as required and as per specifications
115132 KV Gang operated SF6 Circuit Breaker
116Supply of Current transformer along with terminal connectors etc. as required and as per specifications
117132 KV 400-200-100/1-1-1-1A Line CT
118132 KV 400-200-100/1-1A metering CT
119Supply of Isolators along with insulators, terminal connectors etc. as required as per specifications
120132 KV Isolator without Earth Switch (HCB type)
121132 KV Isolator with Earth Switch (HCB type)
122Supply of Lightening arrestors
123132 KV ZnO type Lightneing Arrestor with terminal connectors etc. as per specifocations
124Supply of Post Insulators
125132 KV Post insultaor with terminal connectors as per specifications
126Supply of Potential Transformer
127132 KV/110/√3-110/√3 V Potential Transformer 2 core with terminal connectors etc. as per specifications
128Supply of CVT
129132 KV, 4400 pf Capacitive Voltage Transformer 4 core with terminal connectors etc as per specifications
130Relay and Control Panel
131Control and relay panel with Automation (Simplex Type) with BCU, ethernet switch, line differential relay with distance as backup and AT meter with cubicle and all accessories as required as per specification for SAS integration into existing SAS (Existing SAS is of Hitachi make)
132Mounting Structures
133For CT
134For Isolators with earth switch
135For Isolators without earth switch
136For LA
137For PT
138For CVT
139For PI
140Supply of Column
141Column Type C8(6 Nos)(2111.32kgs/Coloumn)
142Column Type C2(2 Nos)(623.01Kgs/Column)
143Supply of Beam
144Beam Type B2X(4 Nos. )(756.84 kgs/Beam)
145Beam B1( 2 Nos)(717.2 kgs/Beam
146Tower Bolts and Nuts
147Foundation Bolts and Nuts
148Power Cable (Al Core, armoured)
1494C, 6 Sqmm
1504C, 16 Sqmm
151Control Cable (Cu Core, armoured)
1524C, 2.5 Sqmm
1539C, 2.5 Sqmm
15419C, 2.5 Sqmm
155Supply of Power Conductor
156HTLS ACCC Drake Conductor for 132kV Main Bus
157ACSR Zebra Conductor for 132kV Transfer Bus
158Disc insulators and hardware accessories
15910 Disc Tension Insulator String (120kN Disc Insulator
1609 Disc Suspension Insulator String (90 kN Disc Insulatorr
161Supply of earthing materials
162Main Earth Mat (75 mm x 12 mm GI Flat)
16375 mm x 12 mm GI Flat for raiser, equipment/structure earthing
16450 mm x 6 mm GI Flat for equipment earthing
16540 mm dia, 3 mtr MS Rod Electrode with test link for each tower, LAs CVTs, etc.
166Aux Earth Mat
16750 mm x 6 mm GI Flat for indoor panel earthing
168Shield Wire
1697/3.66 mm GI shield wire
170Clamps and Connectors for GI shield wire
171Bay marshalling kiosk with mounting structure and rain shed painted as per site requirement
172Clamps and Connectors for power conductor
173Supply of single tension string assembly with turn buckle though clamp suitable to offered single HTLS conductor
174Supply of single tension string assembly without turn buckle though clamp suitable to offered single HTLS conductor
175Supply of Single suspension string assembly without tun buckle through clamp suitable to offered single HTLS conductor
176supply of T-Clamp to suit offered single HTLS to Single ACSR Zebra
177Supply of Single tension hardware fittings for ACSR Zebra Conductor including all accessories.(120kN Disc Insulator
178Supply of Single suspension hardware fittings for ACSR Zebra Conductor including all accessories.(90 kN Disc Insulator
179Supply of ACDB and DCDB
180Supply of 415 V ACDB as per specifications
181Supply of 110 V DCDB as per specifications
182FO Cables and accessories
183Armoured FO Cable (12 Fibre)
184Line Inteface Unit
185Supply of energy meter
186ABT compliant energy meter with cubicle as per APDCL specifications
187Switchyard Illumination
188Supply of 200 W LED (20nos.) with fittings and accessories, distribution box, MCB, switches , sockets, Cables as required and specified.
189Fire Fighting equipments
190DCP type fire extinguisher Cylinder (25 KG), trolley mounted
191CO2 type fire extinguisher cylinder (6.5 Kg)
192Mandatory spares for 132 KV Circuit Breaker
193Interrupter
194Tripping Coil
195Closing Coil
196Spring charging motor
197Set of all types of gaskets with sealing agent
198Circuit Breaker operating mechanism with all fittings
199Mandatory spares for Relay and Control Panel
200Over curent Relay
201Earth Fault Relay
202Line Differential Relay
203Master Trip Relay
204Trip Circuit Supervision Relay
205Ethernet Switch
206OFC Patch Cord (15 m) with end termination ready
207Spare Isolator with insulators,terminal connectors,structures complete as per specification
208132kV Without Earth Switch
209Mandatory spare
210Complete CT Terminal connector set
211Complete CVT Terminal connector set and stool structure
212132kV LA with terminal connector (spare)
213Clamps and connectors
214PG Clamp with connectors and all hardware fittings suitable for ACSR Zebra conductor
215T-Clamp and Connectors and all hardware fittings suitable for ACSR Zebra Conductor
216TEE Connector Rigid through type alongwith all hardware fittings for 132kV LA and suitable for ACSR Zebra conductor
217TEE Connector Rigid through type alongwith all hardware fittings for 132kV CVT and suitable for ACSR Zebra conductor
218Air Conditioning
219Supply of heavy duty Industrial grade AC as per specification for the kiosk building (Including erection)
220Supply of testing equipments
221Digital Earth Tester
222Miscellneous
22312 KG SF6 gas Cylinder
224SF6 Gas density monitoring device
225Discharge Rods
226Bay Markers
227Erection testing and commissioning of terminal equipments
228Erection, testing and commissioning of 132 KV Circuit Breaker including structure erection, cable laying, termination of cables complete as required.
229Erection, testing and commissioning of 132 KV Isolator(with/without earth switch) including cable laying, termination of cables complete as required.
230Erection, testing and commissioning of 132 KV CT including cable laying, termination of cables complete as required.
231Erection, testing and commissioning of 132 KV PT including cable laying, termination of cables complete as required.
232Erection, testing and commissioning of 132 KV CVT including cable laying, termination of cables complete as required.
233Erection, testing and commissioning of 132 KV PI including cable laying, termination of cables complete as required.
234Erection, testing and commissioning of 132 KV LA including cable laying, termination of cables complete as required.
235Erection testing and commissioning of Relay and Control Panel
236Erection, testing and commissioning of one no. of 132 KV Relay and Control Panel including cable laying, termination of cables complete as required.
237Erection of switchyard steel Structure and Equipment Mounting structures
238Column Type C8(6 Nos)(2111.32kgs/Coloumn)
239Column Type C2(2 Nos)(623.01Kgs/Column)
240Beam Type B2X(4 Nos. )(756.84 kgs/Beam)
241Beam B1( 2 Nos)(717.2 kgs/Beam
242132 KV CB mounting structure
243132 KV Isolator mounting structure
244132 KV CT mounting structure
245132 KV PT mounting structure
246132 KV CVT mounting structure
247132 KV PI mounting structure
248132 KV LA mounting structure
249Integration of Control and Relay Panel with existing SAS (Existing SAS is of Hitachi make) including laying and termination of armoured FO cable
250Installation of Earthing system, testing etc. complete
251Construction of with Main Earth Mat (65 mm x 12 mm GI Flat) as per specifications and site requirement
252Structure earthing with 65 mm x 12 mm GI Flat for raiser
253Equipment earthing with 50 mm x 10 mm GI Flat
254Installation of 40 mm dia, 3 mtr MS Rod Electrode with test link as per site requirement
255Installation of 40 mm dia, 3 mtr MS perforated GI Pipe Electrode with test link as per site requirement
256Indoor panel earthing with 50 mm x 6 mm GI Flat
257Lightning Protection
258Stringing of 7/3.66 mm GI shield wire
259Switchyard Illumination
260Installation, testing and commissioning of bay illumination system (Minimum 4 nos. 100 W LED lights) complete with fittings and accessories, distribution box, MCB, switches , sockets, Cable laying and termination as required and specified.
261Hoisting of insulator string and bus stringing
262Hoisting of insulator strings, stringing of bus conductors, jumpers etc complete as required for complete connection of bay equipments with bus
263Installation of SAMAST Meter
264Installation, testing and commissioning of SAMAST Compliant ABT meter as required as per specification
265Erection of ACDB, DCDB and BMK
266Installation, testing and commissioning of Bay Marshalling Kiosk including construction of foundation (with supply of material and labour) as required as per specification
267Erection, testing and commissioning of ACDB including cable laying, termination of cables complete as required.
268Erection, testing and commissioning of DCDB including cable laying, termination of cables complete as required.
269Site clearance
270Shifting of tower materials,conductor drum and other materials from existing place and restacking into new places and clearing of Debris as per site instruction
271Site clearance by cutting and uprooting of tree trunks, existing PCC etc and disposing off as per site condition for site readyness
272Dismantling of existing structures
273Dismantling of exiting fencing and disposal of unserviceale materials as directed by site in charge
274Dismantling of perking shed and disposal of unserviceale materials as directed by site in charge
275Dismantling of store and workshop building and disposal of unserviceale materials as directed by site in charge
276Dismantling of old AGM office and disposal of unserviceale materials as directed by site in charge
277Dismantling of security booth and disposal of unserviceale materials as directed by site in charge
278Dismantling of LT lines/poles and disposal of unserviceale materials as directed by site in charge
279Construction of foundation including Excavation, Back Filling, Brick Soling, Formwork, PCC, RCC, Reinforcement and supply of all materials/ labour cost required for completing the work
280132 KV Circuit Breaker - 1 No..
281132 KV Iso - 3 Nos.
282132 KV CT - 6 Nos.
283132 KV PT - 3 Nos.
284132 KV CVT - 3 Nos.
285132 KV LA - 3 Nos.
286132 KV PI - 2 Nos.
287cable termination kit structure - 1
288Column Foundation for including Excavation, Back Filling, Brick Soling, Formwork, PCC, RCC, Reinforcement and supply of all materials/ labour cost required for completing the work.
289C8 Column - 6 Nos
290C2 Column- 2 Nos
291Construction of Cable trench for accomodating cables for new bay as per specifications and drawing
292Cable trench (B Type)
293Cable trench (C Type)
294Cable trench (D Type)
295Construction of new kiosk building (size 10x5 mtr) including supply of all materials, cable trench, electric wiring, illumination, fitting fixing of AC etc. complete as per specifications and drawings
296Construction of switchyard PCC road (4.6 mtr wide) including supply of all materials and labour as required as per specifications and drawing
297Construction of rainwater drain including supply of all materials and labour as required as per specifications and drawing
298Switchyard PCC for IOCL including supply of all materials and labour as required as per specifications
299Switchyard gravelling for IOCL bay including supply of all materials and labour as required as per specifications
300Construction of main gate
301Construction of switchyard gate
302Construction of drain in switchyard area
303Construction of boundary wall
304Construction of open store yard along with workshop
305Construction of open raised store space
306Rerouting/Shifting/reconstruction of LT lines as per site equirement
307Construction of switchyard fencing
308Supply of Circuit Breaker with mounting structure, terminal connectors etc as required and as per specifications
309132 KV Gang operated SF6 Circuit Breaker
310Supply of Current transformer along with terminal connectors etc. as required and as per specifications
311132 KV 400-200-100/1-1-1-1A Line CT
312132 KV 400-200-100/1-1A metering CT
313Supply of Isolators along with insulators, terminal connectors etc. as required as per specifications
314132 KV Isolator without Earth Switch (HCB type)
315132 KV Isolator with Earth Switch (HCB type)
316Supply of Lightening arrestors
317132 KV ZnO type Lightneing Arrestor with terminal connectors etc. as per specifocations
318Supply of Post Insulators
319132 KV Post insultaor with terminal connectors as per specifications
320Supply of Potential Transformer
321132 KV/110/√3-110/√3 V Potential Transformer 2 core with terminal connectors etc. as per specifications
322Supply of CVT
323132 KV, 4400 pf Capacitive Voltage Transformer 4 core with terminal connectors etc as per specifications
324Relay and Control Panel
325Control and relay panel with Automation (Simplex Type) with BCU, ethernet switch, line differential relay with distance as backup and AT meter with cubicle and all accessories as required as per specification for SAS integration into existing SAS (Make of existing SAS is Schneider)
326Mounting Structures
327For CT
328For Isolators with earth switch
329For Isolators without earth switch
330For LA
331For PT
332For CVT
333For PI
334Power Cable (Al Core, armoured)
3354C, 6 Sqmm
3364C, 16 Sqmm
337Control Cable (Cu Core, armoured)
3384C, 2.5 Sqmm
3399C, 2.5 Sqmm
34019C, 2.5 Sqmm
341Supply of Power Conductor
342ACSR Zebra Conductor for 132kV
343Disc insulators and hardware accessories
34410 Disc Tension Insulator String (120kN Disc Insulator)
3459 Disc Suspension Insulator String (90 kN Disc Insulator)
346Supply of earthing materials
347Main Earth Mat (75 mm x 12 mm GI Flat)
34875 mm x 12 mm GI Flat for raiser, equipment/structure earthing
34950 mm x 6 mm GI Flat for equipment earthing
35040 mm dia, 3 mtr MS Rod Electrode with test link for each tower, LAs CVTs, etc.
351Aux Earth Mat
35250 mm x 6 mm GI Flat for indoor panel earthing
353Bay marshalling kiosk with mounting structure and rain shed painted as per site requirement
354Clamps and Connectors for power conductor
355Supply of Single tension hardware fittings for ACSR Zebra Conductor including all accessories.(120kN Disc Insulator
356Supply of Single suspension hardware fittings for ACSR Zebra Conductor including all accessories.(90 kN Disc Insulator
357Supply of ACDB and DCDB
358Supply of 415 V ACDB along with all accessories as per specifications
359Supply of 110 V DCDB along with all accessories as per specifications
360FO Cables and accessories
361Armoured FO Cable (12 Fibre)
362Line Inteface Unit
363Supply of energy meter
364ABT compliant energy meter with cubicle as per APDCL specifications
365Spare for Relay and Control Panel
366Over curent Relay
367Earth Fault Relay
368Line Differential Relay
369Master Trip Relay
370Trip Circuit Supervision Relay
371Ethernet Switch
372OFC Patch Cord (15 m) with end termination ready
373Bay Markers
374Supply of Circuit Breaker with mounting structure, terminal connectors etc as required and as per specifications
375132 KV Gang operated SF6 Circuit Breaker
376Supply of Current transformer along with terminal connectors etc. as required and as per specifications
377132 KV 400-200-100/1-1-1-1A Line CT
378132 KV 400-200-100/1-1A metering CT
379Supply of Isolators along with insulators, terminal connectors etc. as required as per specifications
380132 KV Isolator without Earth Switch (HCB type)
381132 KV Isolator with Earth Switch (HCB type)
382Supply of Lightening arrestors
383132 KV ZnO type Lightneing Arrestor with terminal connectors etc. as per specifocations
384Supply of Post Insulators
385132 KV Post insultaor with terminal connectors as per specifications
386Supply of Potential Transformer
387132 KV/110/√3-110/√3 V Potential Transformer 2 core with terminal connectors etc. as per specifications
388Supply of CVT
389132 KV, 4400 pf Capacitive Voltage Transformer 4 core with terminal connectors etc as per specifications
390Relay and Control Panel
391Control and relay panel with Automation (Simplex Type) with BCU, ethernet switch, line differential relay with distance as backup and AT meter with cubicle and all accessories as required as per specification for SAS integration into existing SAS (Make of existing SAS is Schneider)
392Mounting Structures
393For CT
394For Isolators with earth switch
395For Isolators without earth switch
396For LA
397For PT
398For CVT
399For PI
400Power Cable (Al Core, armoured)
4014C, 6 Sqmm
4024C, 16 Sqmm
403Control Cable (Cu Core, armoured)
4044C, 2.5 Sqmm
4059C, 2.5 Sqmm
40619C, 2.5 Sqmm
407Supply of Power Conductor
408ACSR Zebra Conductor for 132kV
409Disc insulators and hardware accessories
41010 Disc Tension Insulator String (120kN Disc Insulator)
4119 Disc Suspension Insulator String (90 kN Disc Insulator)
412Supply of earthing materials
413Main Earth Mat (75 mm x 12 mm GI Flat)
41475 mm x 12 mm GI Flat for raiser, equipment/structure earthing
41550 mm x 6 mm GI Flat for equipment earthing
41640 mm dia, 3 mtr MS Rod Electrode with test link for each tower, LAs CVTs, etc.
417Aux Earth Mat
41850 mm x 6 mm GI Flat for indoor panel earthing
419Bay marshalling kiosk with mounting structure and rain shed painted as per site requirement
420Clamps and Connectors for power conductor
421Supply of Single tension hardware fittings for ACSR Zebra Conductor including all accessories.(120kN Disc Insulator
422Supply of Single suspension hardware fittings for ACSR Zebra Conductor including all accessories.(90 kN Disc Insulator
423Supply of ACDB and DCDB
424Supply of 415 V ACDB along with all accessories as per specifications
425Supply of 110 V DCDB along with all accessories as per specifications
426FO Cables and accessories
427Armoured FO Cable (12 Fibre)
428Line Inteface Unit
429Supply of energy meter
430ABT compliant energy meter with cubicle as per APDCL specifications
431Spare for Relay and Control Panel
432Over curent Relay
433Earth Fault Relay
434Line Differential Relay
435Master Trip Relay
436Trip Circuit Supervision Relay
437Ethernet Switch
438OFC Patch Cord (15 m) with end termination ready
439Bay Markers
440Erection testing and commissioning of terminal equipments
441Erection, testing and commissioning of 132 KV Isolator(with/without earth switch) including cable laying, termination of cables complete as required.
442Erection, testing and commissioning of 132 KV CT including cable laying, termination of cables complete as required.
443Erection, testing and commissioning of 132 KV PT including cable laying, termination of cables complete as required.
444Erection, testing and commissioning of 132 KV CVT including cable laying, termination of cables complete as required.
445Erection, testing and commissioning of 132 KV PI including cable laying, termination of cables complete as required.
446Erection, testing and commissioning of 132 KV LA including cable laying, termination of cables complete as required.
447Erection, testing and commissioning of 132 KV Circuit Breaker including cable laying, termination of cables complete as required.
448Erection testing and commissioning of Relay and Control Panel
449Erection, testing and commissioning of one no. of 132 KV Relay and Control Panel including cable laying, termination of cables complete as required.
450Equipment Structure
451132 KV Isolator mounting structure
452132 KV CT mounting structure
453132 KV PT mounting structure
454132 KV CVT mounting structure
455132 KV PI mounting structure
456132 KV LA mounting structure
457132 KV CB mounting structure
458Integration of Control and Relay Panel with existing SAS including laying and termination of armoured FO cable (Make of existing SAS-Schneider Electric)
459Installation of Earthing system, testing etc. complete
460Construction of Main Earth Mat (65 mm x 12 mm GI Flat) as per specifications and site requirement
461Structure earthing with 65 mm x 12 mm GI Flat for raiser
462Equipment earthing with 50 mm x 10 mm GI Flat
463Installation of 40 mm dia, 3 mtr MS Rod Electrode with test link as per site requirement
464Installation of 40 mm dia, 3 mtr MS perforated GI Pipe Electrode with test link as per site requirement
465Indoor panel earthing with 50 mm x 6 mm GI Flat
466Hoisting of insulator string and bus stringing
467Hoisting of insulator strings, stringing of bus conductors, jumpers etc complete as required for complete connection of bay equipments with bus
468Installation of SAMAST Meter
469Installation, testing and commissioning of SAMAST Compliant ABT meter as required as per specification
470Erection of ACDB, DCDB and BMK
471Installation, testing and commissioning of Bay Marshalling Kiosk including construction of foundation (with supply of material and labour) as required as per specification
472Erection, testing and commissioning of ACDB including cable laying, termination of cables complete as required.
473Erection, testing and commissioning of DCDB including cable laying, termination of cables complete as required.
474Dismantling
475Dismantling of PT with structure
476Dismantling of Isolator with structure
477Construction of foundation including Excavation, Back Filling, Brick Soling, Formwork, PCC, RCC, Reinforcement and supply of all materials/ labour cost required for completing the work
478132 KV Circuit Breaker - 1 No..
479132 KV Iso - 2 Set.
480132 KV CT - 6 Nos.
481132 KV PT - 3 Nos.
482132 KV CVT - 3 Nos.
483132 KV LA - 3 Nos.
484132 KV PI - 3 Nos.
485Cable termination kit structure-1 No.
486Construction of Cable trench for accomodating cables for new bay as per specifications and drawing
487Cable trench (C Type)
488Cable trench (D Type) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58323510
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 10.50 Crore
LAST DATE 25-11-2026
Authority
Authority Name Assam Electricity Grid Corporation Limited
Work Description Tender for Turnkey Construction 132Kv Feeder Bays At Both Ends Including Associated Works For 132Kv Iocl Bgr 2Nd Circuit Line From 132Kv Dhaligaon Gss To Iocl Bongaigaon Refinery
Basic Detail
Tender No AEGCL/MD/Tech-392/IOCL(BGR) BAY/BID
Bidding Type Tender
Location
City Chirang
State Assam
Key Dates
Publish Date 31 Oct 2026
Submission Date 25 Nov 2026
Open Date 26 Nov 2026
Finance
Tender Value 10.50 Crore
Tender Fee 1000
EMD 21 Lakhs
Exemption Available
Document List
1d29d458-5b7a-4e9d-a7b6-7b05a279745b.html
Additional_Docs.rar
Bid1.pdf
Bid2.pdf
BOQ_85692.xls
Tech_Specs.rar
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 31, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 25, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 22 days
Nov 26, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 23 days

Tender Documents

Download All (ZIP) ↓
html

1d29d458-5b7a-4e9d-a7b6-7b05a279745b.html

rar

Additional_Docs.rar

pdf

Bid1.pdf

pdf

Bid2.pdf

xls

BOQ_85692.xls

rar

Tech_Specs.rar

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender