Tender For Turnkey Construction 132Kv Feeder Bays At Both Ends Including Associated Works For 132Kv Iocl Bgr 2Nd Circuit Line From 132Kv Dhaligaon Gss To Iocl Bongaigaon Refinery
Tender Value
10.50 Crore
Estimated cost
Bid Submission
25 Nov 2026
22 days left
EMD
21 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chirang → Assam
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Turnkey Construction 132Kv Feeder Bays At Both Ends Including Associated Works For 132Kv Iocl Bgr 2Nd Circuit Line From 132Kv Dhaligaon Gss To Iocl Bongaigaon Refinery
BOQ
| Sl. No. | Item Description |
| 1 | Supply of Circuit Breaker with mounting structure, terminal connectors etc as required and as per specifications |
| 2 | 132 KV Gang operated SF6 Circuit Breaker |
| 3 | Supply of Current transformer along with terminal connectors etc. as required and as per specifications |
| 4 | 132 KV 400-200-100/1-1-1-1A Line CT |
| 5 | 132 KV 400-200-100/1-1A metering CT |
| 6 | Supply of Isolators along with insulators, terminal connectors etc. as required as per specifications |
| 7 | 132 KV Isolator without Earth Switch (HCB type) |
| 8 | 132 KV Isolator with Earth Switch (HCB type) |
| 9 | Supply of Lightening arrestors |
| 10 | 132 KV ZnO type Lightneing Arrestor with terminal connectors etc. as per specifocations |
| 11 | Supply of Post Insulators |
| 12 | 132 KV Post insultaor with terminal connectors as per specifications |
| 13 | Supply of Potential Transformer |
| 14 | 132 KV/110/√3-110/√3 V Potential Transformer 2 core with terminal connectors etc. as per specifications |
| 15 | Supply of CVT |
| 16 | 132 KV, 4400 pf Capacitive Voltage Transformer 4 core with terminal connectors etc as per specifications |
| 17 | Relay and Control Panel |
| 18 | Control and relay panel with Automation (Simplex Type) with BCU, ethernet switch, line differential relay with distance as backup and AT meter with cubicle and all accessories as required as per specification for SAS integration into existing SAS (Existing SAS is of Hitachi make) |
| 19 | Mounting Structures |
| 20 | For CT |
| 21 | For Isolators with earth switch |
| 22 | For Isolators without earth switch |
| 23 | For LA |
| 24 | For PT |
| 25 | For CVT |
| 26 | For PI |
| 27 | Supply of Column |
| 28 | Column Type C8(6 Nos)(2111.32kgs/Coloumn) |
| 29 | Column Type C2(2 Nos)(623.01Kgs/Column) |
| 30 | Supply of Beam |
| 31 | Beam Type B2X(4 Nos. )(756.84 kgs/Beam) |
| 32 | Beam B1( 2 Nos)(717.2 kgs/Beam |
| 33 | Tower Bolts and Nuts |
| 34 | Foundation Bolts and Nuts |
| 35 | Power Cable (Al Core, armoured) |
| 36 | 4C, 6 Sqmm |
| 37 | 4C, 16 Sqmm |
| 38 | Control Cable (Cu Core, armoured) |
| 39 | 4C, 2.5 Sqmm |
| 40 | 9C, 2.5 Sqmm |
| 41 | 19C, 2.5 Sqmm |
| 42 | Supply of Power Conductor |
| 43 | HTLS ACCC Drake Conductor for 132kV Main Bus |
| 44 | ACSR Zebra Conductor for 132kV Transfer Bus |
| 45 | Disc insulators and hardware accessories |
| 46 | 10 Disc Tension Insulator String (120kN Disc Insulator |
| 47 | 9 Disc Suspension Insulator String (90 kN Disc Insulatorr |
| 48 | Supply of earthing materials |
| 49 | Main Earth Mat (75 mm x 12 mm GI Flat) |
| 50 | 75 mm x 12 mm GI Flat for raiser, equipment/structure earthing |
| 51 | 50 mm x 6 mm GI Flat for equipment earthing |
| 52 | 40 mm dia, 3 mtr MS Rod Electrode with test link for each tower, LAs CVTs, etc. |
| 53 | Aux Earth Mat |
| 54 | 50 mm x 6 mm GI Flat for indoor panel earthing |
| 55 | Shield Wire |
| 56 | 7/3.66 mm GI shield wire |
| 57 | Clamps and Connectors for GI shield wire |
| 58 | Bay marshalling kiosk with mounting structure and rain shed painted as per site requirement |
| 59 | Clamps and Connectors for power conductor |
| 60 | Supply of single tension string assembly with turn buckle though clamp suitable to offered single HTLS conductor |
| 61 | Supply of single tension string assembly without turn buckle though clamp suitable to offered single HTLS conductor |
| 62 | Supply of Single suspension string assembly without tun buckle through clamp suitable to offered single HTLS conductor |
| 63 | supply of T-Clamp to suit offered single HTLS to Single ACSR Zebra |
| 64 | Supply of Single tension hardware fittings for ACSR Zebra Conductor including all accessories.(120kN Disc Insulator |
| 65 | Supply of Single suspension hardware fittings for ACSR Zebra Conductor including all accessories.(90 kN Disc Insulator |
| 66 | Supply of ACDB and DCDB |
| 67 | Supply of 415 V ACDB as per specifications |
| 68 | Supply of 110 V DCDB as per specifications |
| 69 | FO Cables and accessories |
| 70 | Armoured FO Cable (12 Fibre) |
| 71 | Line Inteface Unit |
| 72 | Supply of energy meter |
| 73 | ABT compliant energy meter with cubicle as per APDCL specifications |
| 74 | Switchyard Illumination |
| 75 | Supply of 200 W LED (20nos.) with fittings and accessories, distribution box, MCB, switches , sockets, Cables as required and specified. |
| 76 | Fire Fighting equipments |
| 77 | DCP type fire extinguisher Cylinder (25 KG), trolley mounted |
| 78 | CO2 type fire extinguisher cylinder (6.5 Kg) |
| 79 | Mandatory spares for 132 KV Circuit Breaker |
| 80 | Interrupter |
| 81 | Tripping Coil |
| 82 | Closing Coil |
| 83 | Spring charging motor |
| 84 | Set of all types of gaskets with sealing agent |
| 85 | Circuit Breaker operating mechanism with all fittings |
| 86 | Mandatory spares for Relay and Control Panel |
| 87 | Over curent Relay |
| 88 | Earth Fault Relay |
| 89 | Line Differential Relay |
| 90 | Master Trip Relay |
| 91 | Trip Circuit Supervision Relay |
| 92 | Ethernet Switch |
| 93 | OFC Patch Cord (15 m) with end termination ready |
| 94 | Spare Isolator with insulators,terminal connectors,structures complete as per specification |
| 95 | 132kV Without Earth Switch |
| 96 | Mandatory spare |
| 97 | Complete CT Terminal connector set |
| 98 | Complete CVT Terminal connector set and stool structure |
| 99 | 132kV LA with terminal connector (spare) |
| 100 | Clamps and connectors |
| 101 | PG Clamp with connectors and all hardware fittings suitable for ACSR Zebra conductor |
| 102 | T-Clamp and Connectors and all hardware fittings suitable for ACSR Zebra Conductor |
| 103 | TEE Connector Rigid through type alongwith all hardware fittings for 132kV LA and suitable for ACSR Zebra conductor |
| 104 | TEE Connector Rigid through type alongwith all hardware fittings for 132kV CVT and suitable for ACSR Zebra conductor |
| 105 | Air Conditioning |
| 106 | Supply of heavy duty Industrial grade AC as per specification for the kiosk building (Including erection) |
| 107 | Supply of testing equipments |
| 108 | Digital Earth Tester |
| 109 | Miscellneous |
| 110 | 12 KG SF6 gas Cylinder |
| 111 | SF6 Gas density monitoring device |
| 112 | Discharge Rods |
| 113 | Bay Markers |
| 114 | Supply of Circuit Breaker with mounting structure, terminal connectors etc as required and as per specifications |
| 115 | 132 KV Gang operated SF6 Circuit Breaker |
| 116 | Supply of Current transformer along with terminal connectors etc. as required and as per specifications |
| 117 | 132 KV 400-200-100/1-1-1-1A Line CT |
| 118 | 132 KV 400-200-100/1-1A metering CT |
| 119 | Supply of Isolators along with insulators, terminal connectors etc. as required as per specifications |
| 120 | 132 KV Isolator without Earth Switch (HCB type) |
| 121 | 132 KV Isolator with Earth Switch (HCB type) |
| 122 | Supply of Lightening arrestors |
| 123 | 132 KV ZnO type Lightneing Arrestor with terminal connectors etc. as per specifocations |
| 124 | Supply of Post Insulators |
| 125 | 132 KV Post insultaor with terminal connectors as per specifications |
| 126 | Supply of Potential Transformer |
| 127 | 132 KV/110/√3-110/√3 V Potential Transformer 2 core with terminal connectors etc. as per specifications |
| 128 | Supply of CVT |
| 129 | 132 KV, 4400 pf Capacitive Voltage Transformer 4 core with terminal connectors etc as per specifications |
| 130 | Relay and Control Panel |
| 131 | Control and relay panel with Automation (Simplex Type) with BCU, ethernet switch, line differential relay with distance as backup and AT meter with cubicle and all accessories as required as per specification for SAS integration into existing SAS (Existing SAS is of Hitachi make) |
| 132 | Mounting Structures |
| 133 | For CT |
| 134 | For Isolators with earth switch |
| 135 | For Isolators without earth switch |
| 136 | For LA |
| 137 | For PT |
| 138 | For CVT |
| 139 | For PI |
| 140 | Supply of Column |
| 141 | Column Type C8(6 Nos)(2111.32kgs/Coloumn) |
| 142 | Column Type C2(2 Nos)(623.01Kgs/Column) |
| 143 | Supply of Beam |
| 144 | Beam Type B2X(4 Nos. )(756.84 kgs/Beam) |
| 145 | Beam B1( 2 Nos)(717.2 kgs/Beam |
| 146 | Tower Bolts and Nuts |
| 147 | Foundation Bolts and Nuts |
| 148 | Power Cable (Al Core, armoured) |
| 149 | 4C, 6 Sqmm |
| 150 | 4C, 16 Sqmm |
| 151 | Control Cable (Cu Core, armoured) |
| 152 | 4C, 2.5 Sqmm |
| 153 | 9C, 2.5 Sqmm |
| 154 | 19C, 2.5 Sqmm |
| 155 | Supply of Power Conductor |
| 156 | HTLS ACCC Drake Conductor for 132kV Main Bus |
| 157 | ACSR Zebra Conductor for 132kV Transfer Bus |
| 158 | Disc insulators and hardware accessories |
| 159 | 10 Disc Tension Insulator String (120kN Disc Insulator |
| 160 | 9 Disc Suspension Insulator String (90 kN Disc Insulatorr |
| 161 | Supply of earthing materials |
| 162 | Main Earth Mat (75 mm x 12 mm GI Flat) |
| 163 | 75 mm x 12 mm GI Flat for raiser, equipment/structure earthing |
| 164 | 50 mm x 6 mm GI Flat for equipment earthing |
| 165 | 40 mm dia, 3 mtr MS Rod Electrode with test link for each tower, LAs CVTs, etc. |
| 166 | Aux Earth Mat |
| 167 | 50 mm x 6 mm GI Flat for indoor panel earthing |
| 168 | Shield Wire |
| 169 | 7/3.66 mm GI shield wire |
| 170 | Clamps and Connectors for GI shield wire |
| 171 | Bay marshalling kiosk with mounting structure and rain shed painted as per site requirement |
| 172 | Clamps and Connectors for power conductor |
| 173 | Supply of single tension string assembly with turn buckle though clamp suitable to offered single HTLS conductor |
| 174 | Supply of single tension string assembly without turn buckle though clamp suitable to offered single HTLS conductor |
| 175 | Supply of Single suspension string assembly without tun buckle through clamp suitable to offered single HTLS conductor |
| 176 | supply of T-Clamp to suit offered single HTLS to Single ACSR Zebra |
| 177 | Supply of Single tension hardware fittings for ACSR Zebra Conductor including all accessories.(120kN Disc Insulator |
| 178 | Supply of Single suspension hardware fittings for ACSR Zebra Conductor including all accessories.(90 kN Disc Insulator |
| 179 | Supply of ACDB and DCDB |
| 180 | Supply of 415 V ACDB as per specifications |
| 181 | Supply of 110 V DCDB as per specifications |
| 182 | FO Cables and accessories |
| 183 | Armoured FO Cable (12 Fibre) |
| 184 | Line Inteface Unit |
| 185 | Supply of energy meter |
| 186 | ABT compliant energy meter with cubicle as per APDCL specifications |
| 187 | Switchyard Illumination |
| 188 | Supply of 200 W LED (20nos.) with fittings and accessories, distribution box, MCB, switches , sockets, Cables as required and specified. |
| 189 | Fire Fighting equipments |
| 190 | DCP type fire extinguisher Cylinder (25 KG), trolley mounted |
| 191 | CO2 type fire extinguisher cylinder (6.5 Kg) |
| 192 | Mandatory spares for 132 KV Circuit Breaker |
| 193 | Interrupter |
| 194 | Tripping Coil |
| 195 | Closing Coil |
| 196 | Spring charging motor |
| 197 | Set of all types of gaskets with sealing agent |
| 198 | Circuit Breaker operating mechanism with all fittings |
| 199 | Mandatory spares for Relay and Control Panel |
| 200 | Over curent Relay |
| 201 | Earth Fault Relay |
| 202 | Line Differential Relay |
| 203 | Master Trip Relay |
| 204 | Trip Circuit Supervision Relay |
| 205 | Ethernet Switch |
| 206 | OFC Patch Cord (15 m) with end termination ready |
| 207 | Spare Isolator with insulators,terminal connectors,structures complete as per specification |
| 208 | 132kV Without Earth Switch |
| 209 | Mandatory spare |
| 210 | Complete CT Terminal connector set |
| 211 | Complete CVT Terminal connector set and stool structure |
| 212 | 132kV LA with terminal connector (spare) |
| 213 | Clamps and connectors |
| 214 | PG Clamp with connectors and all hardware fittings suitable for ACSR Zebra conductor |
| 215 | T-Clamp and Connectors and all hardware fittings suitable for ACSR Zebra Conductor |
| 216 | TEE Connector Rigid through type alongwith all hardware fittings for 132kV LA and suitable for ACSR Zebra conductor |
| 217 | TEE Connector Rigid through type alongwith all hardware fittings for 132kV CVT and suitable for ACSR Zebra conductor |
| 218 | Air Conditioning |
| 219 | Supply of heavy duty Industrial grade AC as per specification for the kiosk building (Including erection) |
| 220 | Supply of testing equipments |
| 221 | Digital Earth Tester |
| 222 | Miscellneous |
| 223 | 12 KG SF6 gas Cylinder |
| 224 | SF6 Gas density monitoring device |
| 225 | Discharge Rods |
| 226 | Bay Markers |
| 227 | Erection testing and commissioning of terminal equipments |
| 228 | Erection, testing and commissioning of 132 KV Circuit Breaker including structure erection, cable laying, termination of cables complete as required. |
| 229 | Erection, testing and commissioning of 132 KV Isolator(with/without earth switch) including cable laying, termination of cables complete as required. |
| 230 | Erection, testing and commissioning of 132 KV CT including cable laying, termination of cables complete as required. |
| 231 | Erection, testing and commissioning of 132 KV PT including cable laying, termination of cables complete as required. |
| 232 | Erection, testing and commissioning of 132 KV CVT including cable laying, termination of cables complete as required. |
| 233 | Erection, testing and commissioning of 132 KV PI including cable laying, termination of cables complete as required. |
| 234 | Erection, testing and commissioning of 132 KV LA including cable laying, termination of cables complete as required. |
| 235 | Erection testing and commissioning of Relay and Control Panel |
| 236 | Erection, testing and commissioning of one no. of 132 KV Relay and Control Panel including cable laying, termination of cables complete as required. |
| 237 | Erection of switchyard steel Structure and Equipment Mounting structures |
| 238 | Column Type C8(6 Nos)(2111.32kgs/Coloumn) |
| 239 | Column Type C2(2 Nos)(623.01Kgs/Column) |
| 240 | Beam Type B2X(4 Nos. )(756.84 kgs/Beam) |
| 241 | Beam B1( 2 Nos)(717.2 kgs/Beam |
| 242 | 132 KV CB mounting structure |
| 243 | 132 KV Isolator mounting structure |
| 244 | 132 KV CT mounting structure |
| 245 | 132 KV PT mounting structure |
| 246 | 132 KV CVT mounting structure |
| 247 | 132 KV PI mounting structure |
| 248 | 132 KV LA mounting structure |
| 249 | Integration of Control and Relay Panel with existing SAS (Existing SAS is of Hitachi make) including laying and termination of armoured FO cable |
| 250 | Installation of Earthing system, testing etc. complete |
| 251 | Construction of with Main Earth Mat (65 mm x 12 mm GI Flat) as per specifications and site requirement |
| 252 | Structure earthing with 65 mm x 12 mm GI Flat for raiser |
| 253 | Equipment earthing with 50 mm x 10 mm GI Flat |
| 254 | Installation of 40 mm dia, 3 mtr MS Rod Electrode with test link as per site requirement |
| 255 | Installation of 40 mm dia, 3 mtr MS perforated GI Pipe Electrode with test link as per site requirement |
| 256 | Indoor panel earthing with 50 mm x 6 mm GI Flat |
| 257 | Lightning Protection |
| 258 | Stringing of 7/3.66 mm GI shield wire |
| 259 | Switchyard Illumination |
| 260 | Installation, testing and commissioning of bay illumination system (Minimum 4 nos. 100 W LED lights) complete with fittings and accessories, distribution box, MCB, switches , sockets, Cable laying and termination as required and specified. |
| 261 | Hoisting of insulator string and bus stringing |
| 262 | Hoisting of insulator strings, stringing of bus conductors, jumpers etc complete as required for complete connection of bay equipments with bus |
| 263 | Installation of SAMAST Meter |
| 264 | Installation, testing and commissioning of SAMAST Compliant ABT meter as required as per specification |
| 265 | Erection of ACDB, DCDB and BMK |
| 266 | Installation, testing and commissioning of Bay Marshalling Kiosk including construction of foundation (with supply of material and labour) as required as per specification |
| 267 | Erection, testing and commissioning of ACDB including cable laying, termination of cables complete as required. |
| 268 | Erection, testing and commissioning of DCDB including cable laying, termination of cables complete as required. |
| 269 | Site clearance |
| 270 | Shifting of tower materials,conductor drum and other materials from existing place and restacking into new places and clearing of Debris as per site instruction |
| 271 | Site clearance by cutting and uprooting of tree trunks, existing PCC etc and disposing off as per site condition for site readyness |
| 272 | Dismantling of existing structures |
| 273 | Dismantling of exiting fencing and disposal of unserviceale materials as directed by site in charge |
| 274 | Dismantling of perking shed and disposal of unserviceale materials as directed by site in charge |
| 275 | Dismantling of store and workshop building and disposal of unserviceale materials as directed by site in charge |
| 276 | Dismantling of old AGM office and disposal of unserviceale materials as directed by site in charge |
| 277 | Dismantling of security booth and disposal of unserviceale materials as directed by site in charge |
| 278 | Dismantling of LT lines/poles and disposal of unserviceale materials as directed by site in charge |
| 279 | Construction of foundation including Excavation, Back Filling, Brick Soling, Formwork, PCC, RCC, Reinforcement and supply of all materials/ labour cost required for completing the work |
| 280 | 132 KV Circuit Breaker - 1 No.. |
| 281 | 132 KV Iso - 3 Nos. |
| 282 | 132 KV CT - 6 Nos. |
| 283 | 132 KV PT - 3 Nos. |
| 284 | 132 KV CVT - 3 Nos. |
| 285 | 132 KV LA - 3 Nos. |
| 286 | 132 KV PI - 2 Nos. |
| 287 | cable termination kit structure - 1 |
| 288 | Column Foundation for including Excavation, Back Filling, Brick Soling, Formwork, PCC, RCC, Reinforcement and supply of all materials/ labour cost required for completing the work. |
| 289 | C8 Column - 6 Nos |
| 290 | C2 Column- 2 Nos |
| 291 | Construction of Cable trench for accomodating cables for new bay as per specifications and drawing |
| 292 | Cable trench (B Type) |
| 293 | Cable trench (C Type) |
| 294 | Cable trench (D Type) |
| 295 | Construction of new kiosk building (size 10x5 mtr) including supply of all materials, cable trench, electric wiring, illumination, fitting fixing of AC etc. complete as per specifications and drawings |
| 296 | Construction of switchyard PCC road (4.6 mtr wide) including supply of all materials and labour as required as per specifications and drawing |
| 297 | Construction of rainwater drain including supply of all materials and labour as required as per specifications and drawing |
| 298 | Switchyard PCC for IOCL including supply of all materials and labour as required as per specifications |
| 299 | Switchyard gravelling for IOCL bay including supply of all materials and labour as required as per specifications |
| 300 | Construction of main gate |
| 301 | Construction of switchyard gate |
| 302 | Construction of drain in switchyard area |
| 303 | Construction of boundary wall |
| 304 | Construction of open store yard along with workshop |
| 305 | Construction of open raised store space |
| 306 | Rerouting/Shifting/reconstruction of LT lines as per site equirement |
| 307 | Construction of switchyard fencing |
| 308 | Supply of Circuit Breaker with mounting structure, terminal connectors etc as required and as per specifications |
| 309 | 132 KV Gang operated SF6 Circuit Breaker |
| 310 | Supply of Current transformer along with terminal connectors etc. as required and as per specifications |
| 311 | 132 KV 400-200-100/1-1-1-1A Line CT |
| 312 | 132 KV 400-200-100/1-1A metering CT |
| 313 | Supply of Isolators along with insulators, terminal connectors etc. as required as per specifications |
| 314 | 132 KV Isolator without Earth Switch (HCB type) |
| 315 | 132 KV Isolator with Earth Switch (HCB type) |
| 316 | Supply of Lightening arrestors |
| 317 | 132 KV ZnO type Lightneing Arrestor with terminal connectors etc. as per specifocations |
| 318 | Supply of Post Insulators |
| 319 | 132 KV Post insultaor with terminal connectors as per specifications |
| 320 | Supply of Potential Transformer |
| 321 | 132 KV/110/√3-110/√3 V Potential Transformer 2 core with terminal connectors etc. as per specifications |
| 322 | Supply of CVT |
| 323 | 132 KV, 4400 pf Capacitive Voltage Transformer 4 core with terminal connectors etc as per specifications |
| 324 | Relay and Control Panel |
| 325 | Control and relay panel with Automation (Simplex Type) with BCU, ethernet switch, line differential relay with distance as backup and AT meter with cubicle and all accessories as required as per specification for SAS integration into existing SAS (Make of existing SAS is Schneider) |
| 326 | Mounting Structures |
| 327 | For CT |
| 328 | For Isolators with earth switch |
| 329 | For Isolators without earth switch |
| 330 | For LA |
| 331 | For PT |
| 332 | For CVT |
| 333 | For PI |
| 334 | Power Cable (Al Core, armoured) |
| 335 | 4C, 6 Sqmm |
| 336 | 4C, 16 Sqmm |
| 337 | Control Cable (Cu Core, armoured) |
| 338 | 4C, 2.5 Sqmm |
| 339 | 9C, 2.5 Sqmm |
| 340 | 19C, 2.5 Sqmm |
| 341 | Supply of Power Conductor |
| 342 | ACSR Zebra Conductor for 132kV |
| 343 | Disc insulators and hardware accessories |
| 344 | 10 Disc Tension Insulator String (120kN Disc Insulator) |
| 345 | 9 Disc Suspension Insulator String (90 kN Disc Insulator) |
| 346 | Supply of earthing materials |
| 347 | Main Earth Mat (75 mm x 12 mm GI Flat) |
| 348 | 75 mm x 12 mm GI Flat for raiser, equipment/structure earthing |
| 349 | 50 mm x 6 mm GI Flat for equipment earthing |
| 350 | 40 mm dia, 3 mtr MS Rod Electrode with test link for each tower, LAs CVTs, etc. |
| 351 | Aux Earth Mat |
| 352 | 50 mm x 6 mm GI Flat for indoor panel earthing |
| 353 | Bay marshalling kiosk with mounting structure and rain shed painted as per site requirement |
| 354 | Clamps and Connectors for power conductor |
| 355 | Supply of Single tension hardware fittings for ACSR Zebra Conductor including all accessories.(120kN Disc Insulator |
| 356 | Supply of Single suspension hardware fittings for ACSR Zebra Conductor including all accessories.(90 kN Disc Insulator |
| 357 | Supply of ACDB and DCDB |
| 358 | Supply of 415 V ACDB along with all accessories as per specifications |
| 359 | Supply of 110 V DCDB along with all accessories as per specifications |
| 360 | FO Cables and accessories |
| 361 | Armoured FO Cable (12 Fibre) |
| 362 | Line Inteface Unit |
| 363 | Supply of energy meter |
| 364 | ABT compliant energy meter with cubicle as per APDCL specifications |
| 365 | Spare for Relay and Control Panel |
| 366 | Over curent Relay |
| 367 | Earth Fault Relay |
| 368 | Line Differential Relay |
| 369 | Master Trip Relay |
| 370 | Trip Circuit Supervision Relay |
| 371 | Ethernet Switch |
| 372 | OFC Patch Cord (15 m) with end termination ready |
| 373 | Bay Markers |
| 374 | Supply of Circuit Breaker with mounting structure, terminal connectors etc as required and as per specifications |
| 375 | 132 KV Gang operated SF6 Circuit Breaker |
| 376 | Supply of Current transformer along with terminal connectors etc. as required and as per specifications |
| 377 | 132 KV 400-200-100/1-1-1-1A Line CT |
| 378 | 132 KV 400-200-100/1-1A metering CT |
| 379 | Supply of Isolators along with insulators, terminal connectors etc. as required as per specifications |
| 380 | 132 KV Isolator without Earth Switch (HCB type) |
| 381 | 132 KV Isolator with Earth Switch (HCB type) |
| 382 | Supply of Lightening arrestors |
| 383 | 132 KV ZnO type Lightneing Arrestor with terminal connectors etc. as per specifocations |
| 384 | Supply of Post Insulators |
| 385 | 132 KV Post insultaor with terminal connectors as per specifications |
| 386 | Supply of Potential Transformer |
| 387 | 132 KV/110/√3-110/√3 V Potential Transformer 2 core with terminal connectors etc. as per specifications |
| 388 | Supply of CVT |
| 389 | 132 KV, 4400 pf Capacitive Voltage Transformer 4 core with terminal connectors etc as per specifications |
| 390 | Relay and Control Panel |
| 391 | Control and relay panel with Automation (Simplex Type) with BCU, ethernet switch, line differential relay with distance as backup and AT meter with cubicle and all accessories as required as per specification for SAS integration into existing SAS (Make of existing SAS is Schneider) |
| 392 | Mounting Structures |
| 393 | For CT |
| 394 | For Isolators with earth switch |
| 395 | For Isolators without earth switch |
| 396 | For LA |
| 397 | For PT |
| 398 | For CVT |
| 399 | For PI |
| 400 | Power Cable (Al Core, armoured) |
| 401 | 4C, 6 Sqmm |
| 402 | 4C, 16 Sqmm |
| 403 | Control Cable (Cu Core, armoured) |
| 404 | 4C, 2.5 Sqmm |
| 405 | 9C, 2.5 Sqmm |
| 406 | 19C, 2.5 Sqmm |
| 407 | Supply of Power Conductor |
| 408 | ACSR Zebra Conductor for 132kV |
| 409 | Disc insulators and hardware accessories |
| 410 | 10 Disc Tension Insulator String (120kN Disc Insulator) |
| 411 | 9 Disc Suspension Insulator String (90 kN Disc Insulator) |
| 412 | Supply of earthing materials |
| 413 | Main Earth Mat (75 mm x 12 mm GI Flat) |
| 414 | 75 mm x 12 mm GI Flat for raiser, equipment/structure earthing |
| 415 | 50 mm x 6 mm GI Flat for equipment earthing |
| 416 | 40 mm dia, 3 mtr MS Rod Electrode with test link for each tower, LAs CVTs, etc. |
| 417 | Aux Earth Mat |
| 418 | 50 mm x 6 mm GI Flat for indoor panel earthing |
| 419 | Bay marshalling kiosk with mounting structure and rain shed painted as per site requirement |
| 420 | Clamps and Connectors for power conductor |
| 421 | Supply of Single tension hardware fittings for ACSR Zebra Conductor including all accessories.(120kN Disc Insulator |
| 422 | Supply of Single suspension hardware fittings for ACSR Zebra Conductor including all accessories.(90 kN Disc Insulator |
| 423 | Supply of ACDB and DCDB |
| 424 | Supply of 415 V ACDB along with all accessories as per specifications |
| 425 | Supply of 110 V DCDB along with all accessories as per specifications |
| 426 | FO Cables and accessories |
| 427 | Armoured FO Cable (12 Fibre) |
| 428 | Line Inteface Unit |
| 429 | Supply of energy meter |
| 430 | ABT compliant energy meter with cubicle as per APDCL specifications |
| 431 | Spare for Relay and Control Panel |
| 432 | Over curent Relay |
| 433 | Earth Fault Relay |
| 434 | Line Differential Relay |
| 435 | Master Trip Relay |
| 436 | Trip Circuit Supervision Relay |
| 437 | Ethernet Switch |
| 438 | OFC Patch Cord (15 m) with end termination ready |
| 439 | Bay Markers |
| 440 | Erection testing and commissioning of terminal equipments |
| 441 | Erection, testing and commissioning of 132 KV Isolator(with/without earth switch) including cable laying, termination of cables complete as required. |
| 442 | Erection, testing and commissioning of 132 KV CT including cable laying, termination of cables complete as required. |
| 443 | Erection, testing and commissioning of 132 KV PT including cable laying, termination of cables complete as required. |
| 444 | Erection, testing and commissioning of 132 KV CVT including cable laying, termination of cables complete as required. |
| 445 | Erection, testing and commissioning of 132 KV PI including cable laying, termination of cables complete as required. |
| 446 | Erection, testing and commissioning of 132 KV LA including cable laying, termination of cables complete as required. |
| 447 | Erection, testing and commissioning of 132 KV Circuit Breaker including cable laying, termination of cables complete as required. |
| 448 | Erection testing and commissioning of Relay and Control Panel |
| 449 | Erection, testing and commissioning of one no. of 132 KV Relay and Control Panel including cable laying, termination of cables complete as required. |
| 450 | Equipment Structure |
| 451 | 132 KV Isolator mounting structure |
| 452 | 132 KV CT mounting structure |
| 453 | 132 KV PT mounting structure |
| 454 | 132 KV CVT mounting structure |
| 455 | 132 KV PI mounting structure |
| 456 | 132 KV LA mounting structure |
| 457 | 132 KV CB mounting structure |
| 458 | Integration of Control and Relay Panel with existing SAS including laying and termination of armoured FO cable (Make of existing SAS-Schneider Electric) |
| 459 | Installation of Earthing system, testing etc. complete |
| 460 | Construction of Main Earth Mat (65 mm x 12 mm GI Flat) as per specifications and site requirement |
| 461 | Structure earthing with 65 mm x 12 mm GI Flat for raiser |
| 462 | Equipment earthing with 50 mm x 10 mm GI Flat |
| 463 | Installation of 40 mm dia, 3 mtr MS Rod Electrode with test link as per site requirement |
| 464 | Installation of 40 mm dia, 3 mtr MS perforated GI Pipe Electrode with test link as per site requirement |
| 465 | Indoor panel earthing with 50 mm x 6 mm GI Flat |
| 466 | Hoisting of insulator string and bus stringing |
| 467 | Hoisting of insulator strings, stringing of bus conductors, jumpers etc complete as required for complete connection of bay equipments with bus |
| 468 | Installation of SAMAST Meter |
| 469 | Installation, testing and commissioning of SAMAST Compliant ABT meter as required as per specification |
| 470 | Erection of ACDB, DCDB and BMK |
| 471 | Installation, testing and commissioning of Bay Marshalling Kiosk including construction of foundation (with supply of material and labour) as required as per specification |
| 472 | Erection, testing and commissioning of ACDB including cable laying, termination of cables complete as required. |
| 473 | Erection, testing and commissioning of DCDB including cable laying, termination of cables complete as required. |
| 474 | Dismantling |
| 475 | Dismantling of PT with structure |
| 476 | Dismantling of Isolator with structure |
| 477 | Construction of foundation including Excavation, Back Filling, Brick Soling, Formwork, PCC, RCC, Reinforcement and supply of all materials/ labour cost required for completing the work |
| 478 | 132 KV Circuit Breaker - 1 No.. |
| 479 | 132 KV Iso - 2 Set. |
| 480 | 132 KV CT - 6 Nos. |
| 481 | 132 KV PT - 3 Nos. |
| 482 | 132 KV CVT - 3 Nos. |
| 483 | 132 KV LA - 3 Nos. |
| 484 | 132 KV PI - 3 Nos. |
| 485 | Cable termination kit structure-1 No. |
| 486 | Construction of Cable trench for accomodating cables for new bay as per specifications and drawing |
| 487 | Cable trench (C Type) |
| 488 | Cable trench (D Type) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 31, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 25, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 22 daysNov 26, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 23 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender