Water Resources and Irrigation Government Departments Closing in 4 days TDR #58323506

Tender For Electrically Lifted Irrigation Scheme From Kopili River, Extending From Village Mantabori, Uttar Dharamtul, Bhalukaguri, Chanuabori To Domal Under Jagiroad Lac In Morigaon District Morigaon- Laharighat-Jagiroad Division (I) Under Ridf-Xxxi

Issued by Government Departments · Marigaon, Assam
Tender Value
48.72 Crore
Estimated cost
Bid Submission
23 Nov 2026
4 days left
EMD
97.44 Lakhs
Bank guarantee accepted
Document Fee
20000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Marigaon → Assam
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Electrically Lifted Irrigation Scheme From Kopili River, Extending From Village Mantabori, Uttar Dharamtul, Bhalukaguri, Chanuabori To Domal Under Jagiroad Lac In Morigaon District Morigaon- Laharighat-Jagiroad Division (I) Under Ridf-Xxxii (Nabard) For The Year 2026-27 (Pkg 2)

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 12-Nov-2026 Corrigendum on completion period EELIS from Kopili River, extending from Village Mantabori, Uttar Dharamtul, Bhalukaguri, Chanuabori to Domal (nder Morigaon- Laharighat Div Pkg 2 Technical Bid 23-Nov-2026

BOQ

Name of Work:- Electrically Lifted Irrigation Scheme from Kopili River, extending from Village Mantabori, Uttar Dharamtul, Bhalukaguri, Chanuabori to Domal under Jagiroad LAC in Morigaon District Morigaon- Laharighat-Jagiroad Division (I) under RIDF-XXXII (NABARD) for the year 2026-27 (Pkg 2)
Sl. No. Item Description
1Development of Pressurized Pipe Irrigation Network
2Excavating trenches by mechinical / manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soilUpto 80mm dia
3Excavating trenches by mechinical / manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil80mm dia to 300mm dia
4Excavating trenches by mechinical / manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil300mm dia to 600mm dia
5Excavating trenches by mechinical / manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soilAbove 600mm dia
6Providing and Laying of HDPE Pipes conforming to IS 4984:2016 (supply up to 110 mm dia. in coil and above 110 mm dia. in straight lengths), and laying and jointing of HDPE pipes by electrofusion welding using suitable electrofusion couplers, saddles and other necessary electrofusion fittings, including surface preparation, alignment, clamping, scraping, heating, fusion and cooling as per the manufacturer’s recommendations and relevant applicable standards, to the required alignment and gradient, including testing of the pipeline to the required pressure, complete in all respects.HDPE (PE-100) PN-6 PIPELINE 63 mm
7Providing and Laying of HDPE Pipes conforming to IS 4984:2016 (supply up to 110 mm dia. in coil and above 110 mm dia. in straight lengths), and laying and jointing of HDPE pipes by electrofusion welding using suitable electrofusion couplers, saddles and other necessary electrofusion fittings, including surface preparation, alignment, clamping, scraping, heating, fusion and cooling as per the manufacturer’s recommendations and relevant applicable standards, to the required alignment and gradient, including testing of the pipeline to the required pressure, complete in all respects.HDPE (PE-100) PN-6 PIPELINE 75 mm
8Providing and Laying of HDPE Pipes conforming to IS 4984:2016 (supply up to 110 mm dia. in coil and above 110 mm dia. in straight lengths), and laying and jointing of HDPE pipes by electrofusion welding using suitable electrofusion couplers, saddles and other necessary electrofusion fittings, including surface preparation, alignment, clamping, scraping, heating, fusion and cooling as per the manufacturer’s recommendations and relevant applicable standards, to the required alignment and gradient, including testing of the pipeline to the required pressure, complete in all respects.HDPE (PE-100) PN-6 PIPELINE 90 mm
9Providing and Laying of HDPE Pipes conforming to IS 4984:2016 (supply up to 110 mm dia. in coil and above 110 mm dia. in straight lengths), and laying and jointing of HDPE pipes by electrofusion welding using suitable electrofusion couplers, saddles and other necessary electrofusion fittings, including surface preparation, alignment, clamping, scraping, heating, fusion and cooling as per the manufacturer’s recommendations and relevant applicable standards, to the required alignment and gradient, including testing of the pipeline to the required pressure, complete in all respects.HDPE (PE-100) PN-6 PIPELINE 110 mm
10Providing and Laying of HDPE Pipes conforming to IS 4984:2016 (supply up to 110 mm dia. in coil and above 110 mm dia. in straight lengths), and laying and jointing of HDPE pipes by electrofusion welding using suitable electrofusion couplers, saddles and other necessary electrofusion fittings, including surface preparation, alignment, clamping, scraping, heating, fusion and cooling as per the manufacturer’s recommendations and relevant applicable standards, to the required alignment and gradient, including testing of the pipeline to the required pressure, complete in all respects.HDPE (PE-100) PN-6 PIPELINE 125 mm
11Providing and Laying of HDPE Pipes conforming to IS 4984:2016 (supply up to 110 mm dia. in coil and above 110 mm dia. in straight lengths), and laying and jointing of HDPE pipes by electrofusion welding using suitable electrofusion couplers, saddles and other necessary electrofusion fittings, including surface preparation, alignment, clamping, scraping, heating, fusion and cooling as per the manufacturer’s recommendations and relevant applicable standards, to the required alignment and gradient, including testing of the pipeline to the required pressure, complete in all respects.HDPE (PE-100) PN-6 PIPELINE 140 mm
12Providing and Laying of HDPE Pipes conforming to IS 4984:2016 (supply up to 110 mm dia. in coil and above 110 mm dia. in straight lengths), and laying and jointing of HDPE pipes by electrofusion welding using suitable electrofusion couplers, saddles and other necessary electrofusion fittings, including surface preparation, alignment, clamping, scraping, heating, fusion and cooling as per the manufacturer’s recommendations and relevant applicable standards, to the required alignment and gradient, including testing of the pipeline to the required pressure, complete in all respects.HDPE (PE-100) PN-6 PIPELINE 160 mm
13Providing and Laying of HDPE Pipes conforming to IS 4984:2016 (supply up to 110 mm dia. in coil and above 110 mm dia. in straight lengths), and laying and jointing of HDPE pipes by electrofusion welding using suitable electrofusion couplers, saddles and other necessary electrofusion fittings, including surface preparation, alignment, clamping, scraping, heating, fusion and cooling as per the manufacturer’s recommendations and relevant applicable standards, to the required alignment and gradient, including testing of the pipeline to the required pressure, complete in all respects.HDPE (PE-100) PN-6 PIPELINE 180 mm
14Providing and Laying of HDPE Pipes conforming to IS 4984:2016 (supply up to 110 mm dia. in coil and above 110 mm dia. in straight lengths), and laying and jointing of HDPE pipes by electrofusion welding using suitable electrofusion couplers, saddles and other necessary electrofusion fittings, including surface preparation, alignment, clamping, scraping, heating, fusion and cooling as per the manufacturer’s recommendations and relevant applicable standards, to the required alignment and gradient, including testing of the pipeline to the required pressure, complete in all respects.HDPE (PE-100) PN-6 PIPELINE 200 mm
15Providing and Laying of HDPE Pipes conforming to IS 4984:2016 (supply up to 110 mm dia. in coil and above 110 mm dia. in straight lengths), and laying and jointing of HDPE pipes by electrofusion welding using suitable electrofusion couplers, saddles and other necessary electrofusion fittings, including surface preparation, alignment, clamping, scraping, heating, fusion and cooling as per the manufacturer’s recommendations and relevant applicable standards, to the required alignment and gradient, including testing of the pipeline to the required pressure, complete in all respects.HDPE (PE-100) PN-6 PIPELINE 225 mm
16Providing and Laying of HDPE Pipes conforming to IS 4984:2016 (supply up to 110 mm dia. in coil and above 110 mm dia. in straight lengths), and laying and jointing of HDPE pipes by electrofusion welding using suitable electrofusion couplers, saddles and other necessary electrofusion fittings, including surface preparation, alignment, clamping, scraping, heating, fusion and cooling as per the manufacturer’s recommendations and relevant applicable standards, to the required alignment and gradient, including testing of the pipeline to the required pressure, complete in all respects.HDPE (PE-100) PN-6 PIPELINE 250 mm
17Providing and Laying of HDPE Pipes conforming to IS 4984:2016 (supply up to 110 mm dia. in coil and above 110 mm dia. in straight lengths), and laying and jointing of HDPE pipes by electrofusion welding using suitable electrofusion couplers, saddles and other necessary electrofusion fittings, including surface preparation, alignment, clamping, scraping, heating, fusion and cooling as per the manufacturer’s recommendations and relevant applicable standards, to the required alignment and gradient, including testing of the pipeline to the required pressure, complete in all respects.HDPE (PE-100) PN-6 PIPELINE 280 mm
18Providing and Laying of HDPE Pipes conforming to IS 4984:2016 (supply up to 110 mm dia. in coil and above 110 mm dia. in straight lengths), and laying and jointing of HDPE pipes by electrofusion welding using suitable electrofusion couplers, saddles and other necessary electrofusion fittings, including surface preparation, alignment, clamping, scraping, heating, fusion and cooling as per the manufacturer’s recommendations and relevant applicable standards, to the required alignment and gradient, including testing of the pipeline to the required pressure, complete in all respects.HDPE (PE-100) PN-6 PIPELINE 315 mm
19HDPE SPECIALS FOR HDPE PIPELINE: Providing, supplying, laying and jointing of all necessary HDPE Specials and fittings, including bends, tees, reducers, couplers, electrofusion fittings, electrofusion saddles, flanged adaptors, stub ends, backing flanges/rings, service saddles, end caps and other specials/fittings required for complete execution of the HDPE pipeline, conforming to IS 4984:2016, relevant applicable standards and approved specifications, complete as directed by the Engineer-in-Charge. The quantity/value of HDPE Specials shall be restricted to 2% of the total certified/billed amount under the relevant HDPE Pipe items. For BOQ purposes, the rate shall be considered as ₹1.00 and the quantity shall be equivalent to 2% of the total amount actually certified/billed against the relevant HDPE Pipe items.
20Supply and delivery of DI Pipes as per IS : 8329/2000 including cost and conveyance, excluding taxes etc. complete.including transportation charges and Loading, unloading and stacking,Lowering C.I. / D.I. Pipes (all classes) and specials (fittings) with s/s ends carefully into trenches and laying them true to alignment and gradient including all sundries but excluding cost and conveyance of pipes from source of supply (Ref to specifications. BIS No. 3114 / 1994), Jointing C.I., D.I. pipes and fittings with rubber gasket (push-on-joint), excluding the cost of the gasket but including all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete Reference to specifications IS 3114/1994/12888/1987DI (K-7) PIPELINE 350 mm
21Supply and delivery of DI Pipes as per IS : 8329/2000 including cost and conveyance, excluding taxes etc. complete.including transportation charges and Loading, unloading and stacking,Lowering C.I. / D.I. Pipes (all classes) and specials (fittings) with s/s ends carefully into trenches and laying them true to alignment and gradient including all sundries but excluding cost and conveyance of pipes from source of supply (Ref to specifications. BIS No. 3114 / 1994), Jointing C.I., D.I. pipes and fittings with rubber gasket (push-on-joint), excluding the cost of the gasket but including all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete Reference to specifications IS 3114/1994/12888/1987DI (K-7) PIPELINE 400 mm
22Supply and delivery of DI Pipes as per IS : 8329/2000 including cost and conveyance, excluding taxes etc. complete.including transportation charges and Loading, unloading and stacking,Lowering C.I. / D.I. Pipes (all classes) and specials (fittings) with s/s ends carefully into trenches and laying them true to alignment and gradient including all sundries but excluding cost and conveyance of pipes from source of supply (Ref to specifications. BIS No. 3114 / 1994), Jointing C.I., D.I. pipes and fittings with rubber gasket (push-on-joint), excluding the cost of the gasket but including all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete Reference to specifications IS 3114/1994/12888/1987DI (K-7) PIPELINE 450 mm
23Supply and delivery of DI Pipes as per IS : 8329/2000 including cost and conveyance, excluding taxes etc. complete.including transportation charges and Loading, unloading and stacking,Lowering C.I. / D.I. Pipes (all classes) and specials (fittings) with s/s ends carefully into trenches and laying them true to alignment and gradient including all sundries but excluding cost and conveyance of pipes from source of supply (Ref to specifications. BIS No. 3114 / 1994), Jointing C.I., D.I. pipes and fittings with rubber gasket (push-on-joint), excluding the cost of the gasket but including all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete Reference to specifications IS 3114/1994/12888/1987DI (K-7) PIPELINE 500 mm
24DI SPECIALS FOR DI (K-7) PIPELINE: Providing, supplying, laying and jointing of all necessary DI Specials and fittings, including bends, tees, reducers, collars, flanged adaptors, dismantling joints, puddle flanges and other specials required for complete execution of the DI (K-7) pipeline, conforming to relevant applicable standards and approved specifications, complete as directed by the Engineer-in-Charge. The quantity/value of DI Specials shall be restricted to 2% of the total certified/billed amount under DI Pipes. For BOQ purposes, the rate shall be ₹1.00 and the quantity shall be equivalent to 2% of the total amount actually billed under DI Items.
25Manufacturing, supplying, laying in position,aligning, jointing, testing and commissioning of electric resistance welded/submerged arc welded mild steel (min Fe-410 grade) delivery pipes of specified diameter and plate thickness (as per relevant IS code) with welded endswherever required and provided one coat of 400 micron thick food grade epoxy paint for inner surface and 1000 micron PU/Epoxy or3LPE for outer surface including cost of all materials, machinery, labour, cutting, bending, welding, finishing, painting, conveying to spot,lowering, aligning, jointing, arranging water for testing, ultrasonic/hydraulic testing at fabrication site and after laying and jointing atspecified test pressure etc., complete as per specifications and approved drawings. 600mm
26Manufacturing, supplying, laying in position,aligning, jointing, testing and commissioning of electric resistance welded/submerged arc welded mild steel (min Fe-410 grade) delivery pipes of specified diameter and plate thickness (as per relevant IS code) with welded endswherever required and provided one coat of 400 micron thick food grade epoxy paint for inner surface and 1000 micron PU/Epoxy or3LPE for outer surface including cost of all materials, machinery, labour, cutting, bending, welding, finishing, painting, conveying to spot,lowering, aligning, jointing, arranging water for testing, ultrasonic/hydraulic testing at fabrication site and after laying and jointing atspecified test pressure etc., complete as per specifications and approved drawings. 700mm
27MS Specials (The quantity/value of MS Specials shall be restricted to 2% of the total certified/billed amount under MS Pipes. For BOQ purposes, the rate shall be ₹1.00 and the quantity shall be equivalent to 2% of the total amount actually billed under MS Items.
28Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc.complete.50mm
29Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc.complete.65 mm.
30Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc.complete.80 mm.
31Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc.complete.100 mm.
32Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc.complete.125 mm.
33Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc.complete.150 mm.
34Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc.complete.200 mm.
35Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc.complete.(Rate for all class of valves.)50mm
36Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc.complete.(Rate for all class of valves.)65 mm.
37Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc.complete.(Rate for all class of valves.)80 mm.
38Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc.complete.(Rate for all class of valves.)100 mm.
39Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc.complete.(Rate for all class of valves.)125 mm.
40Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc.complete.(Rate for all class of valves.)150 mm.
41Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc.complete.(Rate for all class of valves.)200 mm.
42Providing and supplying Kinetic Double Orifice type Air Valves confirming to IS 14845 as per MJP’s standard specifications combined with screw down isolating valve,small orifice elastic ball resting on a gun metal orifice nipple,large orifice vulcanite ball seating on moulded seat ring, inlet face and drilled,including insurance, third party inspection charges, loading, unloading, transportation upto departmental stores, excluding GST levied by GOI & GOM in all respect etc.complete.Kinetic Air Valve Flanged Type - PN - 150 mm
43Providing and supplying Kinetic Double Orifice type Air Valves confirming to IS 14845 as per MJP’s standard specifications combined with screw down isolating valve,small orifice elastic ball resting on a gun metal orifice nipple,large orifice vulcanite ball seating on moulded seat ring, inlet face and drilled,including insurance, third party inspection charges, loading, unloading, transportation upto departmental stores, excluding GST levied by GOI & GOM in all respect etc.complete.Kinetic Air Valve Flanged Type - PN - 165 mm
44Providing and supplying Kinetic Double Orifice type Air Valves confirming to IS 14845 as per MJP’s standard specifications combined with screw down isolating valve,small orifice elastic ball resting on a gun metal orifice nipple,large orifice vulcanite ball seating on moulded seat ring, inlet face and drilled,including insurance, third party inspection charges, loading, unloading, transportation upto departmental stores, excluding GST levied by GOI & GOM in all respect etc.complete.Kinetic Air Valve Flanged Type - PN - 180 mm
45Providing and supplying Kinetic Double Orifice type Air Valves confirming to IS 14845 as per MJP’s standard specifications combined with screw down isolating valve,small orifice elastic ball resting on a gun metal orifice nipple,large orifice vulcanite ball seating on moulded seat ring, inlet face and drilled,including insurance, third party inspection charges, loading, unloading, transportation upto departmental stores, excluding GST levied by GOI & GOM in all respect etc.complete.Kinetic Air Valve Flanged Type - PN - 1100 mm
46Providing and supplying Kinetic Double Orifice type Air Valves confirming to IS 14845 as per MJP’s standard specifications combined with screw down isolating valve,small orifice elastic ball resting on a gun metal orifice nipple,large orifice vulcanite ball seating on moulded seat ring, inlet face and drilled,including insurance, third party inspection charges, loading, unloading, transportation upto departmental stores, excluding GST levied by GOI & GOM in all respect etc.complete.Kinetic Air Valve Flanged Type - PN - 1150 mm
47Providing and supplying Kinetic Double Orifice type Air Valves confirming to IS 14845 as per MJP’s standard specifications combined with screw down isolating valve,small orifice elastic ball resting on a gun metal orifice nipple,large orifice vulcanite ball seating on moulded seat ring, inlet face and drilled,including insurance, third party inspection charges, loading, unloading, transportation upto departmental stores, excluding GST levied by GOI & GOM in all respect etc.complete.Kinetic Air Valve Flanged Type - PN - 1200 mm
48Lowering, laying and fixing in proper alignment and position all types of C.I. air valves as directed by Engineer-in-charge including cost of conveyance from stores to site of work, cost of all material and giving satisfactory hydraulic testing, etc. complete.(for all class of valves). 50mm
49Lowering, laying and fixing in proper alignment and position all types of C.I. air valves as directed by Engineer-in-charge including cost of conveyance from stores to site of work, cost of all material and giving satisfactory hydraulic testing, etc. complete.(for all class of valves). 65 mm.
50Lowering, laying and fixing in proper alignment and position all types of C.I. air valves as directed by Engineer-in-charge including cost of conveyance from stores to site of work, cost of all material and giving satisfactory hydraulic testing, etc. complete.(for all class of valves). 80 mm.
51Lowering, laying and fixing in proper alignment and position all types of C.I. air valves as directed by Engineer-in-charge including cost of conveyance from stores to site of work, cost of all material and giving satisfactory hydraulic testing, etc. complete.(for all class of valves). 100 mm.
52Lowering, laying and fixing in proper alignment and position all types of C.I. air valves as directed by Engineer-in-charge including cost of conveyance from stores to site of work, cost of all material and giving satisfactory hydraulic testing, etc. complete.(for all class of valves). 125mm
53Lowering, laying and fixing in proper alignment and position all types of C.I. air valves as directed by Engineer-in-charge including cost of conveyance from stores to site of work, cost of all material and giving satisfactory hydraulic testing, etc. complete.(for all class of valves). 150mm
54Lowering, laying and fixing in proper alignment and position all types of C.I. air valves as directed by Engineer-in-charge including cost of conveyance from stores to site of work, cost of all material and giving satisfactory hydraulic testing, etc. complete.(for all class of valves). 200mm
55Providing, double flanged short body pattern type manually operated Butterfly Valve having body, disc and end cover in graded cast iron to IS-210 Gr.CF 200 generally confirming to IS-13095-1991, Synthetic rubber faced ring secured on disc by retaining ring with stainless steel screw stub shaft of stainless steel riding in teflon bearing including inspection charges, transportation up to departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. excluding C.C. foundation/structural steel support. 200 mm
56Providing, double flanged short body pattern type manually operated Butterfly Valve having body, disc and end cover in graded cast iron to IS-210 Gr.CF 200 generally confirming to IS-13095-1991, Synthetic rubber faced ring secured on disc by retaining ring with stainless steel screw stub shaft of stainless steel riding in teflon bearing including inspection charges, transportation up to departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. excluding C.C. foundation/structural steel support. 250 mm.
57Providing, double flanged short body pattern type manually operated Butterfly Valve having body, disc and end cover in graded cast iron to IS-210 Gr.CF 200 generally confirming to IS-13095-1991, Synthetic rubber faced ring secured on disc by retaining ring with stainless steel screw stub shaft of stainless steel riding in teflon bearing including inspection charges, transportation up to departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. excluding C.C. foundation/structural steel support. 300 mm.
58Providing, double flanged short body pattern type manually operated Butterfly Valve having body, disc and end cover in graded cast iron to IS-210 Gr.CF 200 generally confirming to IS-13095-1991, Synthetic rubber faced ring secured on disc by retaining ring with stainless steel screw stub shaft of stainless steel riding in teflon bearing including inspection charges, transportation up to departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. excluding C.C. foundation/structural steel support. 350 mm.
59Providing, double flanged short body pattern type manually operated Butterfly Valve having body, disc and end cover in graded cast iron to IS-210 Gr.CF 200 generally confirming to IS-13095-1991, Synthetic rubber faced ring secured on disc by retaining ring with stainless steel screw stub shaft of stainless steel riding in teflon bearing including inspection charges, transportation up to departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. excluding C.C. foundation/structural steel support. 400 mm.
60Providing, double flanged short body pattern type manually operated Butterfly Valve having body, disc and end cover in graded cast iron to IS-210 Gr.CF 200 generally confirming to IS-13095-1991, Synthetic rubber faced ring secured on disc by retaining ring with stainless steel screw stub shaft of stainless steel riding in teflon bearing including inspection charges, transportation up to departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. excluding C.C. foundation/structural steel support. 450 mm.
61Providing, double flanged short body pattern type manually operated Butterfly Valve having body, disc and end cover in graded cast iron to IS-210 Gr.CF 200 generally confirming to IS-13095-1991, Synthetic rubber faced ring secured on disc by retaining ring with stainless steel screw stub shaft of stainless steel riding in teflon bearing including inspection charges, transportation up to departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. excluding C.C. foundation/structural steel support. 500 mm.
62Providing, double flanged short body pattern type manually operated Butterfly Valve having body, disc and end cover in graded cast iron to IS-210 Gr.CF 200 generally confirming to IS-13095-1991, Synthetic rubber faced ring secured on disc by retaining ring with stainless steel screw stub shaft of stainless steel riding in teflon bearing including inspection charges, transportation up to departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. excluding C.C. foundation/structural steel support. 600 mm.
63Providing, double flanged short body pattern type manually operated Butterfly Valve having body, disc and end cover in graded cast iron to IS-210 Gr.CF 200 generally confirming to IS-13095-1991, Synthetic rubber faced ring secured on disc by retaining ring with stainless steel screw stub shaft of stainless steel riding in teflon bearing including inspection charges, transportation up to departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. excluding C.C. foundation/structural steel support. 700 mm.
64Providing, double flanged short body pattern type manually operated Butterfly Valve having body, disc and end cover in graded cast iron to IS-210 Gr.CF 200 generally confirming to IS-13095-1991, Synthetic rubber faced ring secured on disc by retaining ring with stainless steel screw stub shaft of stainless steel riding in teflon bearing including inspection charges, transportation up to departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. excluding C.C. foundation/structural steel support. 750 mm.
65Providing, double flanged short body pattern type manually operated Butterfly Valve having body, disc and end cover in graded cast iron to IS-210 Gr.CF 200 generally confirming to IS-13095-1991, Synthetic rubber faced ring secured on disc by retaining ring with stainless steel screw stub shaft of stainless steel riding in teflon bearing including inspection charges, transportation up to departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. excluding C.C. foundation/structural steel support. 800 mm.
66Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. (Rate for all class of valves.) 200mm
67Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. (Rate for all class of valves.) 250 mm.
68Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. (Rate for all class of valves.) 300 mm.
69Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. (Rate for all class of valves.) 350 mm.
70Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. (Rate for all class of valves.) 400 mm.
71Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. (Rate for all class of valves.) 450 mm.
72Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. (Rate for all class of valves.) 500 mm.
73Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. (Rate for all class of valves.)600 mm.
74Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. (Rate for all class of valves.). 700 mm.
75Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. (Rate for all class of valves.). 750 mm.
76Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. (Rate for all class of valves.) 800 mm.
77Construction of Control Room and Operational Infrastructure
78Earthwork in excavation trenches of walls, retaining walls, footing of columns, steps and septic tank including refilling (return filling) the quantity as necessary after completion of works, breaking clods in return filling, dressing, ramming, watering etc. and removal of surplus earth with all lead and lift upto 2 metre as directed and specified in following classification of soils, including bailing out of water where necessary upto depth below the existing groundlevel as mentioned in the approved drawing andcomplete as directed and specified.(A) In ordinary soil
79Soling in foundation at all levels including filling intersides, ramming etc complete as directed and ofspecified thickness with 9 cm brick on flat including sand packing.
80CC Work in proportion 1:3:6 in foundation /abutment/ pier/wing walls etc. with hard broken stone aggregate of size 13 to 38 mm including curing with necessary shuttering , Scafolding etc. where necessary, complete as directed. (shuttering where necessary shall be measured and paid separately).
81Brick work in cement mortar with 1st class brick as directde in foundation, retaining walls, plinth & steps including recking out joints & curing
82Earthwork in filling in all soils in plinth, canal embankment and bed filling as per design section and grade by truck carriage for a minimum distance of 4 KM including paying compensation of earth obtained from private land if any loading, unloading, spreading the same including light jungle, removing trees upto 15 cm dia and uprooting roots and stumps etc. from the seat of the embankment, breaking clods not more than 10 mm cube, ramming, profiling etc. with all lift, complete as directed. (Payment will be made after deduction of 12.50 % shrinkage allowance from the gross quantity).
83Supplying fitting fixing and laying reinforcement (TATA) in position in RCC work including cutting, bending, cranking with two piles 0.91 M (20 BWG) annealed wire hooking tying complete as directed.
84Form work : Centering and shuttering including propping etc where necessary and removal of forms after completion of CC and RCC works as directed complete. (Measurement to be taken on the face area timbered).Shuttering (Column)
85Form work : Centering and shuttering including propping etc where necessary and removal of forms after completion of CC and RCC works as directed complete. (Measurement to be taken on the face area timbered).Tie beam
86Form work : Centering and shuttering including propping etc where necessary and removal of forms after completion of CC and RCC works as directed complete. (Measurement to be taken on the face area timbered).Lintel
87Form work : Centering and shuttering including propping etc where necessary and removal of forms after completion of CC and RCC works as directed complete. (Measurement to be taken on the face area timbered).Chajja
88Form work : Centering and shuttering including propping etc where necessary and removal of forms after completion of CC and RCC works as directed complete. (Measurement to be taken on the face area timbered).Ceiling Beam
89Form work : Centering and shuttering including propping etc where necessary and removal of forms after completion of CC and RCC works as directed complete. (Measurement to be taken on the face area timbered).Slab
90RCC work in slab, abutment cap and above abutment, pier cap, pedestals, dirt wall etc. in proportion 1:1½:3 with hard broken stone aggregate of size 6 mm to 20 mm with proper reinforcement as per design including necessary curing, dewatering etc. complete as directed with necessary timber shuttering, scaffolding etc. where necessary, complete as directed. (Shuttering, scaffolding cost will be paid separately)
91Brick work 7 cm thick with common burnt clay F.P.S. (non modular) brick of class designation 7.5 in cement mortar 1:3 (1 cement : 3 coarse sand) in superstructure above plinth level and upto floor five level.(a) In cement mortar in proportion 1:4.(1 cement:4 sand)
9212 mm cement plastering including clearing surface and curing complete as directed.(ii) In proportion 1:4
93Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece
94Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Old works (one or more coats).
95Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work
9665 mm thick traced flooring with cement concrete in prop 1:2:4 with broken stone agg. of size 6 mm to 20 mm over one 1st class brick flat soling including sand packing of the voids in between the bricks, watering, ramming properly where necessary etc. complete and 12 mm thick cement plastering. Finishing on top trowelling altering curing complete as directed. (Brick soling to be paid seperately).
97Establishment of Communication network and cloud-based Automation Command Centers
98Design, Supply, Erection and Commissioning of Automation System for Pumping Station including PLC, Instruments,Flowmeters etc. And System –Distribution Connectivity in the Distribution Network
99Design, Supply, Erection and Commissioning of Village Management System (VMS) in Village for Flow Control/Pressure Control/Metering/ON-OFF from Remote as and when required for Isolation of downward Network and ease of commissioning.
100Design, Supply, Erection and Commissioning of Air Management System consist of Air Valve with Isolation Valves along with AMS Control Unit for Burst Monitoring by Pressure Monitoring at Air Valve Location in Distribution Network
101Design, Supply, Erection and Commissioning of Outlet Management System (OMS) with Rotation for 5 Ha at 30 Ha for Flow/Pressure Control/Metering/ON-OFF from Remote as and when required for equitable distribution of water.
102Construction of RCC Chambers and Associated Structures for Pressurized Pipe Irrigation Network (RCC Chambers / Structures in the Pipe Network)
103Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
104Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 40 mm nominal size derived from natural sources)
105Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
106Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
107CEMENT PLASTER (IN FINE SAND) 12 mm cement plaster of mix: 1:4 (1 cement: 4 fine sand)
108Construction of RCC Chambers and Associated Structures for Pressurized Pipe Irrigation Network (Spout Chambers in the Pipe Network)
109Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
110Soling in foundation at all levels including fillingSoling in foundation at all levels including filling intersides, ramming etc complete as directed and of specified thickness with 9 cm brick on flat including sand packing.
111C.C work in proportion 1:3:6 in foundation / abutment / piers / wing walls etc.with hard broken stone agg. of size 13 mm to 38 mm including curing with necessary timber shuttering, scaffolding etc.where necessary complete as directed. (Shuttering, scaffolding cost will be paid separately).
1121st class brick work in cement mortar in abutment and wing wall, parapet wall etc.including racking out joints and curing etc. complete. (In proportion 1:4)
113CEMENT PLASTER (IN FINE SAND) 12 mm cement plaster of mix: 1:4 (1 cement: 4 fine sand)
114Supplying, fitting, fixing 110 mm dia PVC Rising pipe from the toe of main line including local carriage, testing leakage etc. complete as directed.
115Supplying, fitting, fixing PVC bend pipe size joining with pipes with solvent cement, testing leakages etc. complete as directed.
116Supplying, fitting, fixing PVC Pipes (IS 12818, 4 kg/cm2), joining pipes with relevant cement, levelling, testing leakages etc. complete as directed. (Cost of E/W foundation trenches will be paid separately).
117Construction of Site Infrastructure and Associated Project Facilities ( Assam Type Operator Rest House)
118Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. In all types of soil.
119Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
120P.C.C WORKS:Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. Concrete of M20 grade with minimum cement content of 270 kg /cum
121R.C.C WORKS:Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
122R.C.C WORKS: In super structure from plinth level up to 1st floor level ii) column , lintel,Chajjah,Roof tie
123DPC works:Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) ncluding manufactured sand derived from Recycled Concrete Aggregate (RCA) upto 25% : 4 graded stone aggregate 20mm nominal size (Recycled Concrete Aggregate (RCA) upto 25%))
124Formworks Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
125Lintels, beams, plinth beams, girders, bressumers and cantilevers
126Columns, Pillars, Piers, Abutments, Posts and Struts
127Lintels, beams, plinth beams, girders, bressumers and cantilevers
128Suspended floors, roofs, landings, balconies and access platform
129BRICKWORKS:Soling in foundation and under floor including filling interstices, ramming etc, complete as directed and asspecified thickness.(i) 9 cm brick on flat including sand packing.
130Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : (b) in prop. 1:4
131Brick work 7 cm thick with common burnt clay F.P.S. (non modular) brick of class designation 7.5 in cement mortar 1:3 (1 cement : 3 coarse sand) in superstructure above plinth level and upto floor five level.
132Tile work in skirting, risers of steps and dado up to 2 m height over 12 mm thick bed of cement mortar 1:3 (1 cement :3 coarse sand) and jointed with grey cement slurry @ 3.3 kg/sqm, including pointing in white cement mixed with pigment of matching shade complete.
133PLASTERING AND POINTING WORKS:18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge.
134Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position with necessary stainless steel screw etc.Kiln seasoned and chemically treated hollock wood
135Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneeringwith vertical grains or cross bands and face veneers on both faces ofshutters.35 mm thick including ISI marked Stainless Steel butt hingeswith necessary screws
136Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISI marked M.S.pressed butt hinges bright finished of required size with necessary screws.30 mm thick
137IRON AND STEEL WORKS:Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Mild steel and Medium Tensile steel bars
138Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete 9.48.2 Fixed to openings /wooden frames with rawl plugs screws etc.
139Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
140PAINTING WORKS:Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification.
141ROOFING WORKS:Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should besupplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
142Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete 12.51.1 Ridges plain (500 - 600mm)
143PLINTH PROTECTION WORKS/DRAIN/ SANITARY Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
144Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 19.1.2 150 mm diameter
145Constructing brick masonry manhole in cement mortar cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : 19.7.1 Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : 19.7.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.51:4 ( 1
146Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:17.1.1 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
147Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 17.10.1 Kitchen sink with drain board 17.10.1.1 510x1040 mm bowl depth 250 mm
148Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of requiredthickness, leveling system and rubber mallet for placing the tiles gently .and easily.
149Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
150Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.
151Providing and fixing insulating board ceiling of approved quality with necessary nails etc. complete ( frame work to be paid separately): Natural colour insulating board.1 12mm thick
152Drilling of Vertical Borewell, Supply & Lowering of Pipe of 100 mm dia UPVC pipe 5 mm to 6.5 mm, Shrouding & Developing of the Tubewell, Supply and Installation of 1 HP Submersible Pump set for 4\\" [100mm dia borewell] including 42mm dia (OD) CPVC 20Kgf column pipe, PVC Insulated cable and MS Controller with Digital Panel for 1 HP Submersible Pump set
153Supply and Installation of Polyethylene water storage tank (1000 L) with cover and suitable locking arrangement including fabrication of MS Stand and erection of the MS Stand with the construction of RCC footing with supportive column
154Plumbing,Sanitary & Electrification
155Construction of Site Infrastructure and Associated Project Facilities ( Boundary Wall )
156Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
157Soling in foundation at all levels including filling intersides, ramming etc complete as directed and of specified thickness with 9 cm brick on flat including sand packing.
158CC work in proportion 1:3:6 inwork in proportion 1:3:6 in foundation / abutment /piers / wing walls etc. with hard river shingles of size 13 mm to 38 mm including curing, dewatering with necessary timber shuttering, scaffolding etc. where necessary, complete as directed. (Shuttering, scaffolding cost will be paid separately
159Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
160Centering and shuttering including propping etc where necessary and removal of forms after completion of CC and RCC works as directed complete. (Measurement to be taken on the face area timbered).Shuttering (Column)
161Centering and shuttering including propping etc where necessary and removal of forms after completion of CC and RCC works as directed complete. (Measurement to be taken on the face area timbered).Shuttering (Beams) with out props
1621st class brick work in cement mortar in abutment and wing wall, parapet wall etc.including racking out joints and curing etc. complete.
163CEMENT PLASTER (IN FINE SAND) 12 mm cement plaster of mix: 1:4 (1 cement: 4 fine sand)
164Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
165Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying apriming coat of approved steel primer usingstructuralsteel etc.as required.
166Construction of Site Infrastructure and Associated Project Facilities ( Approach Road )
167Earthwork in filling in all soils in plinth, canal embankment and bed filling as per design section and grade by cart carriage for a minimum distance of 1 KM including paying compensation of earth obtained from private land if any loading, unloading, spreading the same including light jungle, removing trees upto 15 cm dia and uprooting roots and stumps etc. from the seat of the embankment, breaking clods not more than 10 mm cube, ramming, profiling etc. with all lift, complete as directed. (Payment will be made after deduction of 12.50 % shrinkage allowance from the gross quantity).
168Collection and supply of sand gravel (40% sand and 60% gravel of size 25 mm to 60 mm) free from dust and dirt including stacking in measurable stacks at quarry site and making payment of forest royalty etc. as directed complete. (Quarry distance = 50.00 Km)
169Labour charge for spreading of hard river gravel or broken stone of size 13 mm to 38 mm to the required thickness including dressing and ramming the seat before laying the materials as directed with a lead upto 30 M and lift upto 1.5 M complete as directed.
170Construction of Site Infrastructure and Associated Project Facilities ( Sign Board )
171Supply of sign board made of 1.60mm thick MS iron sheet fitted with steel frame of size 1.05 m x 0.75m fixed with 2 Nos. 50mm dia GI (medium) pipes 2.10m above and 0.60m below ground fitted with C.C. work in proportion 1:3:6 and size 0.45m x 0.45m x 0.60m below ground including painting with approved paint including writing letters complete as directed.
172Riverbank Protection, Stabilization and Erosion Control Works
173Collection and supply of blasted boulder of size 25 cm to 30 cm including stacking at quarry site, complete as directed.
174Labour charge for pitching with one man size boulder including dressing and ramming the seat to proper size and slope, pitching etc. with local carriage of boulders from a distance of 60 M with lift upto 3 M, complete as directed.
175Construction of 1.50 M x 1.00 M rectangular boulder sausage including supplying of materials with 25 cm to 30 cm size boulders collecting from a lead of 25 KM encased in 15 cm mesh of 8G hexagonal wire netting and filling the voids between the boulders with stone not exceeding 18 cm in size tied with 8G galvanized tying wire at 30 cm apart, laid in position as directed including necessary local carriage of materials, paying necessary forest royalty including providing 1 (one) no. of jati bamboo horizontal runner along the top of the sausage with vertical bhaluka bamboo post 1.20 M apart driven at least 0.60 M below ground and tying with sausage etc, all complete as directed.
176Earthwork in cutting in river bank etc. to the design section and grade and removing the spoils to a safe distance including cutting, uprooting and removing trees upto 15 cm dia, uprooting and removing roots and stumps etc, including excavating the earth boulder sausages of 1.00 M dia, 50 cm under river bed shape, size and grade etc. with all lead and lift, complete as directed.
177Plain CC work in 40% plum hard blasted boulder of 15 cm to 23 cm size and filled interstices with 60% cement concrete in proportion 1:3:6 with 13 mm to 38 mm size river shingles including curing, shuttering etc, complete as directed. (Cost of shuttering will be paid separately).
178Labour charge for loose dumping boulder of 23 cm. to 30 cm. size in loose in eroded portion of river bank/ bed including handling charge and including site carriage of boulder from stack yard/ dump site within a distance of 150 m etc. complete as directed. Without Boat
179Electro-Mechanical Works comprising Pumping Arrangement, Pumping Machinery, Primary Filtration System and Surge Protection System
180Installation testing and commissioning of 33/0.433 KV, 500 KVA, ONAN Type, Dyn 11, OUTDOOR Transformer along with OLTC, HV side Cable Box, LV side Cable box. Work including required tools, tackles, consumables, etc. complete in all respects as per direction of Engineer-in-Charge.
181Oil filtration, if required of 33/0.433 KV, 500 KVA, ONAN Type, Dyn 11, Outdoor Transformer along with OLTC including tools, tackles, consumables, etc. complete in all respects as per direction of Engineer-in-Charge.
182Supply, installation, testing, and commissioning of 30 kVAr APFC panel, 415V, 3- phase, APFC relay, contactors, and MCBs. Panel shall be fabricated from CRCA sheet, IP42 enclosure, powder coated. Includes voltmeter, ammeter,indicators, and internal wiring. Complete in all respects for indoor mounting and smooth automatic power factor correction.
183Installation, Testing and Commissioning of 415 V Main PMCC Panel including 3 no. 145 kW VFD, 3 no. 630A MCCB, 3 nos. 300 A MCCBs, complete in all respects as per SLD.
184Supply, Installation, Testing and Commissioning of LPBS (Industrial type, indoor/outdoor, powder coated, ON- push button, mushroom type OFF push button with NO and NC contacts) including tools, tackles, consumables, etc. complete in all respects as per direction of Engineer-in-Charge.
185Supply, installation and commissioning of Outdoor Type Lighting Distribution Board with double door arrangement for 1 Nos.with incomer 32 Amp FP RCBO Type Incomer with 6 no Outgoing of 10 Amp 10 KA DP MCB as per drawing including tools, tackles, consumables, etc. complete in all respects as per direction of Engineer-in-Charge.
186Supply, installation and commissioning of Indoor Type Lighting Distribution Board (LDB-l) with double door arrangement for 1 no I/C 32A FP RCBO & O/G 6 NO 10 Amp 10KA SP MCBS and 2 no 16Amp 10 KA TPN MCB Outgoing as per drawing including tools, tackles, consumables, etc. complete in all respects as per direction of Engineer-in-Charge.
187Supply, testing, tagging, laying and commissioning following sizes of 3300 Volt grade, XLPE / FRLS insulated multistrand Al. / Cu. Conductor armoured / unarmoured cables (As Per IS 1554 & IS 7098) in readymade RCC trench, in provided PVC pipe, RCC pipe hume pipe, on provided cable trays / ladders etc. as. required complete with clamps, hardware for fixing tagging, identification.3C x 300 Sq.mm. A2XFY FRLS cable.
188Supply, Installation, Testing & Commissioning of readymade hot dip galvanized 14/16 SWG perforated trays. Perforated trays shall have support of 75mm 'C' shaped side channels and rungs at 200 mm cc.50 mm perforated tray (16 SWG).
189100 mm perforated tray (16 SWG).
190150 mm perforated tray (16 SWG).
191200 mm perforated tray (16 SWG).
192Supply and installation of readymade powder coated tray covers fabricated from 16/18 SWG CRCA sheets with readymade accessories. e.g. Bend, Tee's,Rightangles etc. with RAL 7032 shade for all vertical runs.50 mm perforated tray
193100 mm perforated tray
194150 mm perforated tray
195200 mm perforated tray
196GI Conduit-50 mm dia required for cable laying
197PVC Conduit-50 mm dia required for cable laying
198Fabrication and erection of structural steel for support of tray , panels and oter electrical items.Work includes provide paint and redoxide ( each two coat), all tools, tackles, consumables, etc.for erection are in contractor scope. complete in all respects as per direction of Engineer-in Charge.
199Fabrication and erection of 6 mm thick chequered plate and work include supply of paint and red oxide( each two coat) all tools, tackles, consumables, etc. for erection are in vendor scope . complete in all respects as per directionof Engineer-in-Charge.
200Supply & Erection, fabrication and testing including excavation earth pit of 600 X 600 X 6 mm GI Plate, 40 mm Dia. 4.5 m. long GI Pipe type earthing,(for Transformer and DG neutral and Instrument earthing) GI Strip, Funnel, Clamp, GI nutbolts, CI cover, etc. for plate Earthing material including preparation of (450 mm X 450 mm) Earth Pit with supply of Bricks, sand, charcoal, salt etc. including tools, tackles, consumables, etc. complete, Printing, Numbering and marking i.e. Pit no., DOT and Ohm value in all respects as per direction of Engineer-in-Charge.
201Supply & Erection, fabrication and testing including excavation earth pit of 40 mm Dia. 4.5 m. long GI Pipe type earthing(For Grid and Body earthing), Funnel, Clamp, GI nutbolts, CI cover etc. for pipe Earthing, material including preparation of (450 mm X 450 mm) Earth Pit with supply of Bricks, sand, charcoal, salt etc. including tools, tackles, consumables, etc. complete, Printing, Numbering and marking i.e. Pit no., DOT and Ohm value in all respects as per direction of Engineer-in-Charge.
202Supply & Laying and fabrication of 50 mm X 6 mm GI Flat, nut bolt for Earthing including tools, tackles, consumables etc. complete in all respects as per direction of Engineer-in-Charge.
203Supply & Laying and fabrication of 25 mm X 3 mm GI Flat, nut bolt for Earthing including tools, tackles, consumables etc. complete in all respects as per direction of Engineer-in-Charge.
204Supply & Installation of Earth Bus of GI-Earth BUS-50 mm X 5 mm 300mm length
205Supply & Laying and fabrication of 8 SWG Wire for earthing with nut bolt for Earthing including tools, tackles, consumables etc. complete in all respects as per direction of Engineer-in-Charge.
206Supply & Laying and fabrication of 8 mm CU conductor for earthing of instrument system with nut bolt for Earthing including tools, tackles, consumables etc. complete in all respects as per direction of Engineer-in-Charge.
2073 meter long vertical air terminal with mounting accessories (Lightning Arrestor).
208Supply & Erection, fabrication and testing including excavation earth pit of ( 3 m long Copper Bonded Mild steel OF DIA 14.2MM IN PIT FOR Lightning - Protection., Funnel, Clamp, GI nutbolts, CI cover etc. for pipe Earthing, material including preparation of (450 mm X 450 mm) Earth Pit with supply of Bricks, sand, charcoal, salt etc. including tools, tackles, consumables, etc. complete, Printing, Numbering and marking i.e. Pit no., DOT and Ohm value in all respects as per direction of Engineer-in-Charge.
209Supply, Installation,Testing, Commissioning of 5 kVA -1 Nos. Online UPS (--- VDC - With Isolation Transformer ) Pure sine wave Double conversion 400V AC In/400 V AC out UPS 30 minutes back up ( Battery set with Interlinks set & battery rack) Suitable to operate from Grid & DG set .And with all standard features & accessories. Static bypass IGBT advance rectifier charger with built in APFC for >0.93 to Unity 6 IGBT PWM DSP inverter with step load 100%, RS 485 port for BMS Factory testing to ISO 62040 part III Battery for UPS 1/2 hr discharge as the per case, comprising 12 V AGM-SMF cells placed on structural steel multitier battery stand, duly epoxy primer +intermidiate +final coat of epoxy paint in dry film thickness of 100 micron & finished in polyeurathane paint in 30 micron complete with intercell connectors, Insulating mat, spanner,thermometer etc.
210Supply, installation, testing, and commissioning of 1 No. 110V DC Nickel- Cadmium battery bank of minimum 75Ah capacity , suitable for substation protection, control, and emergency operations, complete with interconnecting links, stands, vent plugs, electrolyte (if applicable), and accessories.
211Supply, installation, testing, and commissioning of 1 No. automatic float-cum- boost charger for 110V DC battery system, suitable for continuous float and boost charging modes, with necessary meters, alarms, protections, and control panel, complete in all respects.
212Supply, installation, testing, and commissioning of 1 No. 110V DC Distribution Board with incomer and multiple outgoing feeders, equipped with MCBs, indication lamps, terminals, and proper labeling, suitable for protection andcontrol applications in substation environments.
213Miscleneous item including safety items
214Fabrication and erection of structural steel for support of tray , panels and other electrical items.Work includes provide paint and redoxide ( each two coat), all tools, tackles, consumables, etc.for erection are in contractor scope.complete in all respects as per direction of Engineer-in-Charge.
215Fabrication and erection of 6 mm thick chequered plate and work include supply of paint and red oxide( each two coat) all tools, tackles, consumables, etc. for erection are in vendor scope . complete in all respects as per direction of Engineer-in-Charge.
216Supplying, laying , testing & commissioning of R.C.C. NP3 Hume pipe with spigot and rubber rings including all accessories, jointing material, laying tolevel etc. complete.300 mm diameter
217Supplying, Erecting, testing & commissioning of B.B. masonry inspection chambers of following sizes with cement concrete bedding 150 mm thick in cement mortar 1:6 and benching from inside with 1:2:4 CC and plastering with cement mortar 1:3 from inside and outside and fixing air tight pre-cast coversas per the size.750mm x 750mm x 750mm
2184 Pole Structure with Isolators, Lightning Arresters, DO Fuse, Earth Mats with CTs, PTs, Metering panel for 33kV system
219Supply of Main 33KV HT Panel comprising of 1 no. 630A VCB I/C & 2 Nos VCB O/G with all accessories & necessary indications metering and protection
220Supply, Installation, Testing and commissioning of 25KVA DG Set
221Mechanical Works for Pump StationDesign, Supply, Installation, Testing & Commissioning of VT Pump Set suitable for inclined intake well — SS impeller, CI/WCB casing, 132 kW (415 V 3-Phase ) submersible motor, with discharge bend, rising column, strainer, cable, chain,mechanical seals & fittings complete. (5W + 1S)
222PLC-HMI control panel, metering, auto/manual/remote operation, SCADA interface, cabling & earthing. For PH-01
223Electrically Operated Hoist (EOT)Design, Drawing, fabrication, supply, erection, testing and commissioning of EOT crane consisting of double girder box type construction, rail mounted end carriages with long and cross travel arrangement, main and auxiliary hoists of specified capacity, rails, pendant control, gear boxes, electric motors, brakes, rope drums, wire ropes, sheaves, end buffer stoppers, pendant operated DSL bus bars with all accessories for main and auxiliary hoists for handling pumps and accessories in pump house including cost of all materials, machinery, labour, cutting, aligning, welding, finishing, cleaning, greasing, applying two coats of zinc chromate red oxide primer and three coats of synthetic enamel paint etc., complete as per specifications and approved drawings with all lead and lifts, including packing & forwarding transportation charges for structural steel components and other materials for PH-01
224Electrically Operated Butterfly Valve (BFV) - 300mmProviding, double flanged short body pattern type electrically operated Butterfly Valve of PN10 rating having body, disc andend cover in graded cast iron to IS-210 Gr.CF 200 generally confirming to IS-13095-1991, Synthetic rubber face dring secured on disc by retaining ring with stainless steel screw stub shaft of stainless steel riding inteflonbearing including inspection charges,transportation up to departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. excluding C.C. foundation /structural steel support.
225Dismantling Joint (DJ) 300mmSupplying and fixing Mild Steel (MS) fabricated Dismantling joint confirming to IS 2062 E250 BR including all lead and lifts etc. complete.
226Non Return Valve (NRV) 300mmSupplying, installing, testing and commissioning (SITC) Cast steel double flanged dual plate Check valve of PN10 rating Class 150 conforming to API 594 of approved make of specified diameter and to withstand specified pressure with all accessories true to line and perfect linking with pipes on either side including loading, unloading, lifting and placing in correct position, cleaning ends, inserting gaskets into correct position, jointing pipes and valve to form water tight joints, cost of all jointing materials, machinery, labour including all lead and lifts etc. complete.
227Flow Meter (FM) 300mmSupplying, installing and commissioning electro-magnetic type flow meter of approved make with all accessories including display panel in the pump house including all lead and lifts.
228Air valve (AV) 80mmProviding and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid separately) :
229Pressure Gauge
230Pressure Transmitter
231Design, Supply, Erection and Commissioning of Surge Protection System.
232Design,Supply,Erection and Commissioning of Self Cleaning Primary Filtration Systemof 200 Micron at Intake or Suitable Pumping Station.
233Electrical Works comprising HT Line, Substation and Associated Electrical Installations
234Surveying and finalising the suitable tapping point in existing nearby 11 kV line in consultation with APDCL and Departmental Officers, marking the alignment of the line considering Right of Way, Feasibility etc. as required and as directedFor first 500Mtrs.
235For every subsequent 100 M beyond 500 M Length
236Jungle cutting including cutting of branches of trees and reclining Bamboos along the alignment of the overhead line providing clearance 1.5M either side and above the line as directed. Clearance must be ensured at the time of charging the line
237Supplying & Erection of PSC Pole conforming to IS 1678 of Standard Dimension and of following lengths for overhead Electric Lines including digging of Earth Pit (0.75m × 0.5m) to a depth ⅕th of the Pole Length with a PCC Base Plate of size 60 cm × 60 cm × 12 cm at the bottom, refilling as specified with hard ramming as directed(B).POLE LENGTH 9.75 Metres (i) Refilling with Hard Soil (a) for 6 or more poles
238Supplying and erection of GI Channel Cross Arm of following sizes for 11 kV Line on PSC/ Steel Poles along with GI Clamps, GI Nuts & Bolts including drilling of necessary holes as directed100 mm X 50 mm X 6 mm X 3200 mm
239Supplying and erection of GI T Cross Arm for 11 kV Line on PSC Poles along with Clamps, Nuts & Bolts including drilling of necessary holes as directed
240Supplying and erection of Cross Bracing Sets for 11 kV Line on DP (Double Pole) Structure comprising of 2(two) Nos. of G I Angle of size 50 mm × 50 mm × 6 mm × 2200 mm fitted horizontally and other 2 Nos. 3200 mm long fitted diagonally along with G I Pole Clamps, Nuts Bolts and washer duly painted with Anti Corrosive Primer and Aluminium Paint including drilling of necessary holes as directed
241Supplying and Erection of 11 kV HT Stay Set comprising of Stay Rod, Anchor Plate, Thimble etc. in 1:3:6 CC foundation including supply and erection of 7/10 SWG G I Stay Wire and Guy Insulator complete including excavation, refilling with hard soil and hard ramming as directed
242Supply and erection of G I Stay Wire 7/10 SWG along with 11 kV Guy insulator, binding to existing 11kV Stay Set and the GI Pole Clamp, tightening to required extent as directed.
243Supplying and Erection of 11 kV Polymeric Pin Insulator 5 kN on T Cross Arm/ Channel along with GI Pin, GI Nuts & Bolts including Drilling of Holes as directed
244Supplying and Erection of Hardware Fittings (3u bolt) on existing MS / GI Channel Cross Arm with GI Nuts and Bolts for mounting 11 kV Disc Insulator 45 kN as directed
245Supplying and Erection of 11 kV Polymeric Disc Insulator 45 kN on existing Hardware Fitting on Cross Arm as directed
246Supplying, Laying and Erection of Conductors offollowing size and specification for Overhead Line,binding to Insulators and Tensioning with UniformStandard Sag including Jumpering connection asdirectedAAA Raccoon Conductor - 7/3.81 mm
247Supplying, Fitting and Erection of 3-φ 11 kV Gang Operated (G.O.) Air Break Switch having nominal System Voltage of 12 kV, rated Voltage 11 kV, rated Frequency 60 Hz, and peak current in closed position 46 kA, conforming to IS 2544, IS 5340(Part-III) and IS 9921(Part I to V) suitable to opearate in all climatic condition of following current ratings on existing Channels complete with Operating Pipe and Handle including making of necessary Electrical Connections as directed. 400 Amps
248Supplying and Erection of 3-φ 11kV Drop Out (D.O.) Fuse Unit rated voltage 11 kV R.M.S. To 12 kV R.M.S., highest System Voltage 12 kV, each pole consisting of Polymericinsulator, all current carrying parts made of a highly conductive copper alloy and contact portion are silver plated for corrosion resistance and efficient current flow and the fuse tube made of fibre glass coated with ultraviolet inhibitr on the outer surface and having Arc Quenching bone fibre liner inside conforming to IS 9385/1983 of following current ratings on existing Channels complete with Barrel Fuse and making of necessary Electrical Connections as directed. (400 Amps)
249Supplying and Erection of Metal Oxide gapless Lightning Arrestor of following specification on MS Channel with Clamps, Nuts & Bolts including drilling of holes and making of necessary connection with Line Conductors as directed. 9 kV, 10 kA with Polymeric body
250Supply & Erection of C.I. Earth Pipe 100 mm dia × 2.5 Metre long perpendicular to the ground including digging of Earth Pit, putting Salt and Charcoal in alternate layers surrounding the pipe along with fitting of hinged CI top Cover Plate and necessary C.C. work as directed
251Supply including Erection of 5 Star ON-AN (Oil Natural, air Natural) Cooled Al/ CU-wound Distribution Transformer conforming to IS specifications 2026 (with latestamendments)withallstandardaccessorieserected on double pole structure/ transformer pad including transportation and handling, loading and unloading etc,, securing it on existing Channel firmly with necessary clamps, nuts & bolts .as required, andmaking necessary connections on HV and LV sides as directed (Cost of DP structure /Pad extra ) Capacity : 500 kVA, 11 kV/0.433 kV(Dyn), (as per CEA Guideline) (Cu-wound) with OLTC
252Erection & Commissioning of H T metering unit comprising of 11 kV/110V, 3-Ph CT/PT etc., Meter Cabinet, Electronic HT Energy Meter, making connection through Control Copper Cable to be laid through 20 mm dia G.I. Pipe complete including making necessary payment for Meter Security, cost of CT/PT Set etc. to APDCL as required and as directed
253Supply & Erection of Anti Climbing Barbed Wire on Poles at a height of about 3 Metres and covering a length of 1.5 Metre as directed
254Supplying including erection of powder coated LT Feeder Panel /Metering Panel for 500 kVA DTR of size (800mm × 1200mm × 400mm) made of 16 SWG CR sheet and 40mm × 40mm × 6mm MS angle having CR sheet roofing containing Cu Busbar and 1 no 500 A FP MCCB, (50kA) making necessary connection through copper cable complete as directed..
255Supply and Laying of Single Core PVC/ XLPE Insulated Armoured LT Power Cable 1.1 kV Grade with Al Conductor in existing open trench/ in air including fixing with necessary clamps etc. in wall/ pole/ other support including End Termination with Brass Compression Gland and Cable Lug as required and as directed Size of Cable : 400 Sq mm × 1 core(4 line)
256Supply and Laying of 3½(Three and half) Core PVC/ XLPE Insulated Armoured LT Power Cable 1.1 kV Grade with Al Conductor in existing open trench/ in air including fixing with necessary clamps etc. in wall/ pole/ other support including End Termination with Brass Compression Gland and Cable Lug as required and as directed Size of Cable : 400 mm2 × 3.5 Core ( Single Line)
257Supply and Laying of 3½(Three and half) Core PVC/ XLPE Insulated Armoured LT Power Cable 1.1 kV Grade with Al Conductor in existing open trench/ in air including fixing with necessary clamps etc. in wall/ pole/ other support including End Termination with Brass Compression Gland and Cable Lug as required and as directed Size of Cable : 300 mm2 × 3.5 Core ( Single Line)
258Supply and Laying of 3(Three) Core PVC/ XLPEInsulated Armoured LT Power Cable 1.1 kV Gradewith Al Conductor in existing open trench/ in airincluding fixing with necessary clamps etc. in wall/pole/ other support including End Termination withBrass Compression Gland and Cable Lug as requiredand as directedSize of Cable : 70 mm2 × 3 Core ( Single Line)
259Testing and commissioning of the 11kV line including making payment for necessary Inspection Fee and obtaining charging approval from competent authority (Electrical Inspectorate) as directed a) upto 1 kM
260Danger plate suitable for 11KV line conforming to IS:2552/1963 of size 200mmX200mm
261Providing Security fencing around the S/S with GI chain link net, woven with 10 SWG wire with mesh 7.5cm × 7.5cm to be erected on GI angle 40 mm × 40mm × 5mm, with necessary C C grouting, with a fencing height of 1.8 mtr, having a hinged door, fabricated with flat GI strip boundary and cross bracing, complete including supply of all materials, excavation refilling etc as reqd and as directed.
262Testing and commissioning of the Substation alongwith obtaining necessary approval for charging from competent authority including payment of Inspection Fee, Arranging for Test Report etc. as required and as directed for following kVA Capacity. Capacity : 500 kVA, 11 kV/0.433 kV
263LiaisoningwithAPDCL,ForestDepartment,Electrical Inspectorate etc. right from start till Commissioning of the HT Line/Substation, Preparation of all necessary documents like Agreement and Affidavit required for new Power Connection, obtaining No Objection Certificate from Forest Department where necessary complete all arrangement for charging the Installation as required and as directed.
264Erection & Commissioning LT Whole Current Electronic Energy Meter includingmaking necessary payment to APDCL for Meter Cabinet, Meter Security etc as reqd and as directed.
265Load Security to be paid to APDCL (Approx.)
266Internal Electrification
267External IlluminationSupplying & Erection of Swaged Type Steel Tubular Pole of following lengths and specifications for overhead Electric Lines with necessary Base Plate and Top Cap including digging of Earth Pit to a depth ⅕th of the Pole Length, refilling and necessary CC work (45cm x 45 cm) in 1:3:6 proportion from bottom upto 45 cm above the Ground Level with hard ramming including painting of the pole as directed (for lighting purpose)a) 8 m long
268Supply & erection of Street light luminaries with 2x36w CFL Lamp, Bajaj Make on existing pole bracket alongwith supply fitting fixing of necessary pole box and making connection from pole box to the lamp with 2.5mm sq single core unsheathed PVC insulated Copper cable 1100volt Grade including supply of Cable as required and as directed
269Laying of PVC/XLPEe insulated Armourd LT Power Cable 1.1Kv Grade with Al Conductor Direct in ground including digging of trench of 0.75 m deep including Sand Cushing and refilling alongwith brick protection every 20cm apart as directed. Size of Cable 6mmsq x 2 core .
270Construction of Pump House
271Earthwork in excavation trenches of walls, retaining walls, footing of columns, steps and septic tank including refilling (return filling) the quantity as necessary after completion of works, breaking clods in return filling, dressing, ramming, watering etc. and removal of surplus earth with all lead and lift upto 2 metre as directed and specified in following classification of soils, including bailing out of water where necessary upto depth below the existing groundlevel as mentioned in the approved drawing andcomplete as directed and specified.(A) In ordinary soil
272Earthwork in excavation trenches of walls, retaining walls, footing of columns, steps and septic tank including refilling (return filling) the quantity as necessary after completion of works, breaking clods in return filling, dressing, ramming, watering etc. and removal of surplus earth with all lead and lift upto 2 metre as directed and specified in following classification of soils, including bailing out of water where necessary upto depth below the existing groundlevel as mentioned in the approved drawing andcomplete as directed and specified.(C)Extra for lift beyond 2.00 M upto 3.00 M for all classification of soils.
273Earthwork inback fillingof structures, obtained fromoutsideborrowpits filling in15 cmlayers, ramming,dressing, watering, including paying compensation ofland if any (with lead up to 30 M and lift 1.5 M)
274Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap).20.2.1 450 mm dia piles
275Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap).20.2.3 600 mm dia piles
276Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge
277Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering-All work up to plinth level: 4.1.8: 1:4:8(1Cement:4coarse sand (zone- ll) derived from natura lsources:8 graded stone aggregate 40 mm nominal size derived from natural sources)
278Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources,Portland Pozzolana/Ordinary Portland /Portland Slagcement, admixtures in recommended proportions as per IS:9103 to accelerate Iretard setting of concrete,to improve durability and workability without impairings trength;including pumping of concrete to site of laying, curing, carriage for all leads;bu texcluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to10% of the minimum specified cement content in design mix shall be payable separately.In case the cement content in design mix is more than 110%of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or be arthe cost of extra cement.4.20.2 All works above plinth and up to floor level4.20.2.4: Concrete of M25 grade with minimum cement content of 300kg/cum
279Centering and shuttering including propping etc where necessary and removal of forms after completion of CC and RCC works as directed complete. (Measurement to be taken on the face area timbered).Shuttering (Column)
280Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources,Portland Pozzolana/Ordinary Portland /Portland Slagcement, admixtures in recommended proportions as per IS:9103 to accelerate Iretard setting of concrete,to improve durability and workability without impairings trength;including pumping of concrete to site of laying, curing, carriage for all leads;bu texcluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to10% of the minimum specified cement content in design mix shall be payable separately.In case the cement content in design mix is more than 110%of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or be arthe cost of extra cement. 4.20.1 All works up to plinth level: 4.20.1.4 Concrete of M25 grade with minimum cement content of 300kg/cum
281Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources,Portland Pozzolana/Ordinary Portland /Portland Slagcement, admixtures in recommended proportions as per IS:9103 to accelerate Iretard setting of concrete,to improve durability and workability without impairings trength;including pumping of concrete to site of laying, curing, carriage for all leads;bu texcluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to10% of the minimum specified cement content in design mix shall be payable separately.In case the cement content in design mix is more than 110%of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or be arthe cost of extra cement.4.20.2 All works above plinth and up to floor level4.20.2.4: Concrete of M25 grade with minimum cement content of 300kg/cum
282Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources,Portland Pozzolana/Ordinary Portland /Portland Slagcement, admixtures in recommended proportions as per IS:9103 to accelerate Iretard setting of concrete,to improve durability and workability without impairings trength;including pumping of concrete to site of laying, curing, carriage for all leads;bu texcluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to10% of the minimum specified cement content in design mix shall be payable separately.In case the cement content in design mix is more than 110%of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or be arthe cost of extra cement.4.20.2 All works above plinth and up to floor level4.20.2.4: Concrete of M25 grade with minimum cement content of 300kg/cum
283Centering and shuttering including propping etc where necessary and removal of forms after completion of CC and RCC works as directed complete. (Measurement to be taken on the face area timbered).Shuttering (Column)
284Centering and shuttering including propping etc where necessary and removal of forms after completion of CC and RCC works as directed complete. (Measurement to be taken on the face area timbered).Shuttering (Beam)
285Centering and shuttering including propping etc where necessary and removal of forms after completion of CC and RCC works as directed complete. (Measurement to be taken on the face area timbered).Shuttering (Slab)
286Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.5.22.6: Thermo-Mechanically Treated bars of grade Fe-500D or more.
287M.S Pipe of dia 1000 mm
288M.S Pipe of dia 1000 mm (Charges of laying by pushing method)
289Header pipe of 1200 mm dia ( below pump house)
290M.S Pipe for pumping Verical 1200 mm dia
291Outlet Header pipe 1200 mm dia
292Brick work in cement mortar with 1st class brick as directde in foundation, retaining walls, plinth & steps including recking out joints & curing
293Rolling Shutter ( 2 nos) (3.1x2.50m)
294Gantry crane of 8 tonn capacity and span (8.0 m)
295Valves and Fitting
296Railway crossing, Road crosing & River Crossing
297River (Stream) Crossing ABS HDPE-250 mm Dia.
298Road Crossing ABS HDPE-250 mm Dia.
299River (Stream) Crossing ABS HDPE-315 mm Dia.
300Road Crossing ABS HDPE-315 mm Dia.
301River (Stream) Crossing ABS DI-350 mm Dia.
302Road Crossing ABS DI-350 mm Dia.
303Railway Crossing Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58323506
AUTHORITY Government Departments
TENDER VALUE 48.72 Crore
LAST DATE 23-11-2026
Authority
Authority Name Irrigation Department
Work Description Tender for Electrically Lifted Irrigation Scheme From Kopili River, Extending From Village Mantabori, Uttar Dharamtul, Bhalukaguri, Chanuabori To Domal Under Jagiroad Lac In Morigaon District Morigaon- Laharighat-Jagiroad Division (I) Under Ridf-Xxxii (Nabard) For The Year 2026-27 (Pkg 2)
Basic Detail
Tender No ACEIMPMIT168Pt-XV2026-27 08 Dt_22_10_2026
Bidding Type Tender
Location
City Marigaon
State Assam
Key Dates
Publish Date 12 Nov 2026
Submission Date 23 Nov 2026
Open Date 01 Jan 0001
Finance
Tender Value 48.72 Crore
Tender Fee 20000
EMD 97.44 Lakhs
Exemption Available
Document List
5196696c-157e-4b5c-a226-5faeda70a641.html
Bid2.pdf
BOQ_85728.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 12, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 23, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 4 days
Nov 23, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
html

5196696c-157e-4b5c-a226-5faeda70a641.html

pdf

Bid2.pdf

xls

BOQ_85728.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender