Educational and Research Institute Government Departments Closing in 13 days TDR #58323314

Tender For Supply & Installation Of 10 Kva 3 Phase Igbt Based Transformer Isolated Ups

Issued by Government Departments · Nanded, Maharashtra
Tender Value
Ref. Documents
Estimated cost
Bid Submission
16 Nov 2026
13 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Offline

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Nanded → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Supply & Installation Of 10 Kva 3 Phase Igbt Based Transformer Isolated Ups Main Input Voltage Other Input Voltage Efficiency At Full Load Input Connection Input Frequency Output Voltage Other Output Voltage Rated Power Rated Power Output Connection Bypass Type Crest Factor Current/Voltage Thd Maximum Configurable Power Maximum Configurable Power Ups Topology Waveform Type Input Power Factor Efficiency Output Frequency Battery Type Control Panel Emergency Power Off Alarm Ups Connectivity Surge Energy Rating Number Of Rack Unit Color Height Width Depth Product Weight Mounting Location 400 V Ac 3 Phases 380/400/415 V 176...300 V (Full Load) Value 1 Hard Wire 5-Wire (3P + N + E) 40...70 Hz (Auto Sensing) 400 V Ac 3 Phases + Neutral 380/400/415 V 10,000 W 10,000 Va Hard Wire 5-Wire (3P + N + E) For 1 Zone(S) Internal Bypass (Automatic And Manual) 3:1 <5% 10,000 Va 10,000 W On-Line Sine Wave ≥0.98 ≥95% (Full Load) 50/60 Hz +/-3 Hz Sync To Mains Lead-Acid External Sold Separately Multifunction Lcd Status And Control Console Yes Alarm When On Battery: Distinctive Low Battery Alarm: Overload Continuous Tone Alarm Serial Port/ Usb Port/ Available Expansion Slot 600 J 3U Black (Ral 7010) 130 Mm 438 Mm 749 Mm 25 Kg Front No Preference Rack-Mounted With Kit Yes Horizontal Rack-Mounted With Kit Sold Separately Mounting Preference Mounting Mode Usb Compatible Mounting Position Mounting Mode Number Of Power Modules Filled Slots 0 Number Of Power Module Free Slots Redundant Range Of Product Product Or Component Type Product Certification 이 No Easy Ups On-Line Uninterruptible Power Supply (Ups) Bis, Cf, Rosh Compliance, Iso 9001 & Iso 14001 Certificate Miat 1|Page Ambient Air Temperature For Operation Ambient Air Temperature For Storage Storage Altitude Ip Protection Relative Humidity Storage Relative Humidity Acoustic Level Heat Dissipation Operating Altitude Battery Type Battery Voltage Extendable Runtime Included Battery Module Empty Battery Slot Battery Charging Power Warranty (In Months) 0...40 °C -20...60 °C 0...15000 M Ip20 0...95% Non-Condensing 0...95% Non-Condensing 60 Dba 2128 Btu/H 0...3000 M External Battery System +120 V 0 0 O

AI Tender Summary

OUR REF NO 58323314
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 16-11-2026
Authority
Authority Name shri guru gobind singhji institute of engineering and technology
Work Description Tender For Supply & Installation Of 10 Kva 3 Phase Igbt Based Transformer Isolated Ups Main Input Voltage Other Input Voltage Efficiency At Full Load Input Connection Input Frequency Output Voltage Other Output Voltage Rated Power Rated Power Output Connection Bypass Type Crest Factor Current/Voltage Thd Maximum Configurable Power Maximum Configurable Power Ups Topology Waveform Type Input Power Factor Efficiency Output Frequency Battery Type Control Panel Emergency Power Off Alarm Ups Connectivity Surge Energy Rating Number Of Rack Unit Color Height Width Depth Product Weight Mounting Location 400 V Ac 3 Phases 380/400/415 V 176...300 V (Full Load) Value 1 Hard Wire 5-Wire (3P + N + E) 40...70 Hz (Auto Sensing) 400 V Ac 3 Phases + Neutral 380/400/415 V 10,000 W 10,000 Va Hard Wire 5-Wire (3P + N + E) For 1 Zone(S) Internal Bypass (Automatic And Manual) 3:1 <5% 10,000 Va 10,000 W On-Line Sine Wave ≥0.98 ≥95% (Full Load) 50/60 Hz +/-3 Hz Sync To Mains Lead-Acid External Sold Separately Multifunction Lcd Status And Control Console Yes Alarm When On Battery: Distinctive Low Battery Alarm: Overload Continuous Tone Alarm Serial Port/ Usb Port/ Available Expansion Slot 600 J 3U Black (Ral 7010) 130 Mm 438 Mm 749 Mm 25 Kg Front No Preference Rack-Mounted With Kit Yes Horizontal Rack-Mounted With Kit Sold Separately Mounting Preference Mounting Mode Usb Compatible Mounting Position Mounting Mode Number Of Power Modules Filled Slots 0 Number Of Power Module Free Slots Redundant Range Of Product Product Or Component Type Product Certification 이 No Easy Ups On-Line Uninterruptible Power Supply (Ups) Bis, Cf, Rosh Compliance, Iso 9001 & Iso 14001 Certificate Miat 1|Page Ambient Air Temperature For Operation Ambient Air Temperature For Storage Storage Altitude Ip Protection Relative Humidity Storage Relative Humidity Acoustic Level Heat Dissipation Operating Altitude Battery Type Battery Voltage Extendable Runtime Included Battery Module Empty Battery Slot Battery Charging Power Warranty (In Months) 0...40 °C -20...60 °C 0...15000 M Ip20 0...95% Non-Condensing 0...95% Non-Condensing 60 Dba 2128 Btu/H 0...3000 M External Battery System +120 V 0 0 O
Basic Detail
Tender No SGGSIET/Store-3686/10 KVA 3 Phase UPS/Extc Department/2026-27
Bidding Type Tender
Location
City Nanded
State Maharashtra
Key Dates
Publish Date 02 Nov 2026
Submission Date 16 Nov 2026
Open Date 17 Nov 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Not Available
Document List
bdaf69c0-9f6a-46ef-9f51-ce7ad2f429b6.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 02, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 16, 2026
17:00 IST

Bid Submission Deadline

Offline submission at the designated office.

Upcoming · 13 days
Nov 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 14 days

Tender Documents

Download All (ZIP) ↓
pdf

bdaf69c0-9f6a-46ef-9f51-ce7ad2f429b6.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender