Housing Urban and Rular Development Government Departments Closing in 7 days TDR #58322303

Tender For Rate Contract For Various Electrical Work Including Repair And Maintenance Etc. Under The Jurisdiction Of Pwd Electrical Sub Division-V, Jaipur And Other Area, Jaipur.

Issued by Government Departments · Jaipur, Rajasthan
Tender Value
50 Lakhs
Estimated cost
Bid Submission
12 Nov 2026
7 days left
EMD
1 Lakhs
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jaipur → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Rate Contract For Various Electrical Work Including Repair And Maintenance Etc. Under The Jurisdiction Of Pwd Electrical Sub Division-V, Jaipur And Other Area, Jaipur.

BOQ

Name of Work:- Rate Contract for various Electrical work including repair and maintenance etc. under the Jurisdiction of PWD Electrical Sub Division-V, Jaipur and other area, Jaipur.`
Sl. No. Item Description
1Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, Aluminum round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 6 A Modular switch, Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required.
2Short point (up to 3 mtr.)
3Medium point (up to 6 mtr.)
4Long point (up to 10 mtr.)
5Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, Aluminium round tiles, 2 Nos Hot Dipped Galvanized M.S Modular box of 1.2 mm thick with earth terminal,2 Nos 6 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate, screws, making connections, testing etc. as required.
6Short point (up to 3 mtr.)
7Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal, 6 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.
8On board
9Short point (up to 3 mtr.)
10Medium point (up to 6 mtr.)
11Long point (up to 10 mtr..)
12S&F following sizes (dia.) of ISI marked MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including making jhiri in the wall,clamps at suitable spacing, covering conduit and making good the same as required.
1320 mm
1425 mm
1532 mm
1640 mm
17Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, Aluminium round tiles, 1.2 mm thick Hot dipped Galavanized MS box with earth terminal, 6 A switch, 3 pin ceiling rose/holder / 3 way connector , 3.0 mm thick ISI marked (IS:2036-1995) phenolic laminated sheet, Al.alloy / Cadmium plated iron/ brass screws, cup washers, making connections, testing etc. as required.
18Short point (up to 3 mtr.)
19Medium point (up to 6 mtr.)
20Long point (up to 10 mtr.)
21Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, Aluminium round tiles, 2 Nos 1.2 mm thick Hot dipped Galavanized MS box with earth terminal, 2 Nos 6 A two way switch,3 pin ceiling rose / holder/ 3 way connector, 3.0 mm thick ISI marked (IS:2036-1995) phenolic laminated sheet, Al.alloy / Cadmium plated iron/ brass screws, cup washers, making connections, testing etc. as required.
22Short point (up to 3 mtr.)
23Medium point (up to 6 mtr.)
24Long point (up to 10 mtr..)
25Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, 1.2 mm thick Hot dipped Galavanized MS box with earth terminal of required size, 6 A switch, 3/5 pin 6 A socket, 3.0 mm thick ISI marked (IS:2036-1995) phenolic laminated sheet, Al.alloy / Cadmium plated iron/ brass screws, cup washers, making connections, testing etc. as required.
26On board
27Short point (up to 3 mtr.)
28Medium point (up to 6 mtr.)
29Long point (up to 10 mtr..)
30Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) on surface ISI marked ( IS:14927 P - II ) uPVC trunking & it's accessories, Hot Dipped Galvanized Modular box 1.2 mm thick with earth terminal/ Surface mounted UPVC molded modular box, 6 A Modular switch, Modular face plate with grid plate, 3 pin ceiling rose/holder /3 way Connector, screws, making connections, testing etc. as required.
31Short point (up to 3 mtr.)
32Medium point (up to 6 mtr.)
33Long point (up to 10 mtr.)
34Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) of approved make on surface ISI marked ( IS:14927 P - II ) uPVC trunking & it's accessories, 2 No. Hot Dipped Galvanized Modular box 1.2 mm thick with earth terminal/ 2 No. Surface mounted UPVC molded modular box, 2 Nos 6 A two way Modular switch, 3 pin ceiling rose / holder/3 way Connector , Modular face plate with grid plate, screws, making connections, testing etc. as required
35Short point (up to 3 mtr.)
36Medium point (up to 6 mtr.)
37Long point (up to 10 mtr..)
38Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade(IS:694) on surface ISI marked ( IS:14927 P - II ) uPVC trunking & it's accessories, Hot Dipped Galvanized Modular box 1.2 mm thick with earth terminal/Surface mounted UPVC molded modular box, modular 6 A switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required
39On board
40Short point (up to 3 mtr.)
41Medium point (up to 6 mtr.)
42Long point (up to 10 mtr..)
43S&F following sizes of ISI marked ( IS:14927 P - II ) uPVC trunking along with accessories like coupler, inner, outer, elbow, square box, tee, end cap etc. on surface with screws, expansion fasteners etc. as required.
4420 mm x 12 mm
4525 mm x 12 mm
4632 mm x 12 mm
4725 mm x 16 mm
4838 mm x 16 mm
4938 mm x 25 mm
5038 mm x 38 mm
5150 mm x 16 mm
5250 mm x 50 mm
5375 mm x 50 mm
5475 mm x 75 mm
55100 mm x 50 mm
56100 mm x 100 mm
57Supplying and laying FR PVC insulated & unsheathed flexible copper conductor of following nominal sizes with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from copper, stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required.
581 x 1.5 sq.mm
592 x 1.5 sq.mm
603x 1.5 sq.mm
614 x 1.5 sq.mm
621 x 2.5 sq.mm
632 x 2.5 sq.mm
642 x 2.5 sq. mm. + 1x1.5sqmm
653 x 2.5 sq.mm
664 x 2.5 sq.mm
671 x 4.0 sq.mm
682 x 4.0 sq.mm
693 x 4 sq. mm.
704 x 4.0 sq.mm
712 x 4.0 sq. mm. + 1 x 2.5 sq. mm.
721 x 6.0 sq.mm
732 x 6.0 sq.mm
743 x 6.0 sq. mm.
754 x 6.0 sq.mm
762 x 6.0 sq. mm. + 1 x 2.5 sq. mm.
772 x 6.0 sq. mm. + 1 x 4.0 sq. mm.
781 x 10.0 sq.mm
792 x 10.0 sq.mm
804 x 10.0 sq.mm
811 x 16.0 sq.mm
822 x 16.0 sq.mm
83Supplying and Laying coaxial cable 75 ohm impedance with foam PE insulated solid bare copper inner conductor, and Ist outer conductor of bonded alum. tape and second outer conductor of alum. alloy braid in existing surface or recessed conduit/casing capping including making connections as required.
84RG - 6
85RG -11
86Supplying and Laying PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 & confirming to TEC specification GR / WIR/06-03 March 2002 in existing surface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required.
872 pair
884 pair
895 pair
9010 pair
9120 pair
9250 pair
93100 pair
94200 pair
95100 pair
96200 pair
97Supply and Laying of PE Insulated, PVC Inner Sheathed, armoured & PVC Sheathed Telephone Cable. with 0.5 mm thick Solid Annealed Bare Copper Conductor as per IS: 8130/84 telephone cable confirming to TEC specifications GR/WIR 06/03, Mar.-2002 in existing pipe / open trench / Cable tray / on surface including making necessary connection, testing etc. as required of size.
985 pair
9910 pair
10020 pair
10150 pair
102100 pair
103200 pair
104Supply and Laying of PE Insulated jelly filled Armoured Telephone Cable. with 0.6 mm thick Solid Annealed Bare Copper Conductor and confirming to TEC specifications confirming. to DOT GR/CUG-01/Aug.2003 in existing pipe / open trench / Cable tray / on surface including making necessary connection, testing etc. as required of size.
1055 pair
10610 pair
10720 pair
10850 pair
109100 pair
110200 pair
111Supply & laying service connection with ISI marked (IS:694) 1100 Volts grade PVC insulated flat twin core sheathed solid aluminium conductor with 10 SWG G.I. Support wire duly clipped etc. as required.
1122.5sq.mm
1134.0 sq.mm
1146.0 sq.mm
11510.0 sq.mm
116Supply and Laying ISI marked P.V.C. insulated submersible cable confirming to(IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from copper, stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, existing pipe / open trench / Cable tray / on surface including making connection etc. as required.
1171.5 Sq.mm 3 core flat / Round
1182.5 Sq.mm 3 core flat / Round
1194.0 Sq.mm 3 core flat / Round
120Supply and laying following size twin parallel type Speaker cables made with multi wire, bright annealed flexible bare electrolytic grade copper conductor, insulated with specially formulated transparent grade PVC compound, red strip for identification in existing conduit etc. as required.
1210.75 sq.mm
1221.0 Sq. mm
1231.5 Sq.mm
1242.5 Sq.mm
125Supply and laying speaker cable of following size 2 core twin twisted multi stranded electrolytic grade copper conductor, overall PVC insulated and armoured cable (Blue colour) on surface/ above false ceiling including cost of GI spacers, saddles etc. as required.
1260.75 sq.mm
1271.0 Sq. mm
1281.5 Sq.mm
1292.5 Sq.mm
130Supply and laying PVC Insulated and PVC Round Sheathed Multi Core copper conductor (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from copper, stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing pipe / open trench / Cable tray / on surface including making connection etc. as required.
1311.5 sq.mm x 3 core
1321.5 sq.mm x 4 core
1331.5 sq.mm x 6 core
134Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanism , energy limiting of class 3 as per IEC, minimum phase termination capacity of 25 sq.mm., conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating, 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required.
135Single pole MCB (With B / C curve tripping characteristics)
1360.5 A to 5 A rating
1376 A to 32 A rating
13840 A rating
13950/63 A rating
14080 A rating
141100 A rating
142125 A rating
143Double pole MCB (With B / C curve tripping characteristics)
1440.5 A to 5 A rating
1456 A to 32 A rating
14640 A rating
14750/63 A rating
14880 A rating
149100 A rating
150125 A rating
151Triple pole MCB (With B / C curve tripping characteristics)
1520.5A to 5 A rating
1536 A to 32 A rating
15440 A rating
15550/63 A rating
156Four pole MCB (With B / C curve tripping characteristics)
1570.5A to 5 A rating
1586 A to 32 A rating
15940 A rating
16050/63 A rating
161Triple pole MCB (With D curve tripping Characteristics)
1620.5 A to 5 A rating
1636 A to 32 A rating
16440 A rating
16550/63 A rating
166Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door (Metal / Glazed / Acrylic) Distribution board with Metal end box made out from Galvanized steel / CRCA sheet, powder coated conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, complete with 100 amp. insulated copper bus bar/shorting link , brass neutral link with shrouds, brass earth link , door earthing arrangement, color coded interconnecting wire set of minimum 10.0 sqmm size and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required.
167Metal door (single phase) IK-09 and IP-43 with Metal end box
1684 Way
1696 Way
1708 Way
17112 Way
17216 Way
173Glazed / Acrylic door (single phase) IK-09 and IP-43 with Metal end box
1744 Way
1756 Way
1768 Way
17712 Way
17816 Way
179Metal door (Three phase) IK-09 and IP-43 with Metal end box
1804 Way (8 incomer + 12 Outgoing)
1816 Way (8 incomer + 18 Outgoing)
1828 Way (8 incomer + 24 Outgoing)
18312 Way (8 incomer + 36 Outgoing)
184Glazed / Acrylic door (Three phase) IK-09 and IP-43 with Metal end box
1854 Way (8 incomer + 12 Outgoing)
1866 Way (8 incomer + 18 Outgoing)
1878 Way (8 incomer + 24 Outgoing)
18812 Way (8 incomer + 36 Outgoing)
189Providing & Fixing of Recessed/surface mounting heavy duty Flexi / Row type Distribution board with Metal end box made out from Galvanized steel / CRCA sheet , powder coated conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3 complete with 100 Amp. copper shorting link , brass neutral link with shrouds, brass earth link , color coded interconnecting wire set of suitable rating and din bar, door earthing arrangement, masking sheet, making internal DB terminations with copper lugs, ferrules detachable gland plate, including making connections, testing etc. as required.
190Double door IK-09 & IP-43 with metal End box
1914 Row 32 Module(8 module per row)
1924 Row 40 Module(10 module per row)
1934 Row 56 Module(14 module per row)
1943 Row 42 Module(14 module per row) with provision of 160 Amp. MCCB
195Providing & Fixing of Recessed/surface mounting heavy duty Flexi / Row type Distribution board with Metal end box made out from Galvanized steel / CRCA sheet , powder coated conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3 complete with 100 Amp. copper shorting link , brass neutral link with shrouds, brass earth link , color coded interconnecting wire set of suitable rating and din bar, door earthing arrangement, masking sheet, making internal DB terminations with copper lugs, ferrules detachable gland plate, including making connections, testing etc. as required.
196Double door IK-09 & IP-43 with metal End box
1974 Row 32 Module(8 module per row)
1984 Row 40 Module(10 module per row)
1994 Row 56 Module(14 module per row)
2003 Row 42 Module(14 module per row) with provision of 160 Amp. MCCB
201Glazed / Acrylic door IK-09 & IP-43 with Metal End Box
2024 Row 32 Module(8 module per row)
2034 Row 40 Module(10 module per row)
2044 Row 56 Module(14 module per row)
205P&F metal clad / Polyamide industrial plug top & socket unit with pin and sleeve type contact on porcelain/ bakelite base in Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet , powder coated conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. (without MCB) including making connections, testing etc.as required.
20620 amp, (2P + E), 1 Module
20720 amp, (2P + E), 2 Module
20820 amp, (2P + E), 3 Module
20932 amp, (3P + E), 3 Module
21032 amp, (3P + N + E) 8 Module (with Polyamide Plug & Socket)
21163 amp, (3P + N+ E), 8 Module (with Polyamide Plug & Socket)
212P & F of Industrial plug and socket conforming to IEC 60309-1/2 made out of self extinguishing engineering polymer / polyamide, nickel plated brass sleeve and pins, socket with shutter including making connection etc as reqd.
213IP -67, IK - 09 Panel mounted socket
21416 A (2P+E)
21532 A (2P+E)
21632 A (3P+N+E)
21763 A (3P+N+E)
218IP -67, IK-09 Surface/Wall mounted socket
21916 A (2P+E)
22032 A (2P+E)
22132 A (3P+N+E)
22263 A (3P+N+E)
223IP -66, Surface/Wall mounted Interlocked switched socket Outlet with Provision of MCB
22416 A (2P+E) 250 V
22532 A (2P+E), 250 V
22632 A (3P+E), 415 V
227IP - 67 Plug top
22816 A (2P+E)
22932 A (2P+E)
23032 A (3P+E)
23132 A (3P+N+E)
232Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box with provision of incomer suitable for MCB / RCCB/ RCBO up to 63 Amp and SP / TP MCB upto 32 Amp. as outgoing ,made out from Galvanized steel / CRCA sheet, powder coated conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3 complete with insulated 100 A rating copper bus bar, brass neutral bars with shrouds, brass earth bar , color coded interconnecting wire set of suitable rating and din bar, door earthing arrangement, masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required.
233Double door IK-09 & IP-43 with Metal end box
2344 Way (8 Incomer +12 Outgoing)
2356 Way (8 Incomer +18 Outgoing)
2368 Way (8 Incomer +24 Outgoing)
23712 Way (8 Incomer + 36 Outgoing)
238Double door IP-43 & IK-09 with Provision of Incomer MCCB up to 125 A Rating with Metal end box
2394 Way
2406 Way
2418 Way
24212 Way
243Double door IP-43 & IK-09 with Provision of Incomer MCCB 160 A Rating with Metal End Box
2444 Way
2456 Way
2468 Way
24712 Way
248Double door IP-43 & IK-09 with Provision of Incomer MCCB 200/250 A Rating with metal End Box
2494 Way
2506 Way
2518 Way
25212 Way
253P & F Surface mounting IP-65, IK-09 Class-II self extinguishing insulating material weather proof cabinets confirming to EN60439-3 with IP-65 Key lock, fully reversible door and cabinet, removable chasis and face plates, of following size.
2543/4 module
2556 module
2568 module
2571 row 12 module
2582 row 24 module
2593 row 36 module
260P & F ISI marked (IS:3854) 6 amp. flush type non modular switch with CM/L no. printed and made out from industrial grade Polycarbonate material including cutting hole in tile and making connection testing etc. as required.
261P & F ISI marked (IS :3854) 16 amp. flush type non modular switch CM/L no. printed and made out from industrial grade Polycarbonate material including cutting hole in tile and making connection testing etc. as required.
262Providing & Fixing of 6 amp. Combined flush type non modular socket and switch set made out from industrial grade Polycarbonate material including cutting hole in tile and making connection testing etc. as required.
263Providing & Fixing of 16 amp. Combined flush type non modular socket and switch set with indicator and fuse set, made out from industrial grade Polycarbonate material including cutting hole in tile and making connection testing etc. as required.
264Providing & Fixing of ISI marked (IS :3854) non modular 6A bell push surface type CM/L no. printed and made out from industrial grade Polycarbonate material including making connection testing etc. as required.
265Providing & Fixing of ISI marked (IS :3854) twin control non modular 6A switch surface type, CM/L no. printed and made out from industrial grade Polycarbonate material, brass terminal & captive screws including making connection testing etc. as required.
266Providing & Fixing of ISI marked (IS :3854) non modular 6A bell push flush type CM/L no. printed and made out from industrial grade Polycarbonate materialincluding cutting hole in tile and making connection testing etc. as required.
267Providing & Fixing of ISI marked (IS :3854) twin control non modular 6A switch flush type CM/L no. printed , made out from industrial grade Polycarbonate material, including cutting hole in tile and making connection testing etc. as required.
268Providing & Fixing of non modular 6A hanging bell push/one way switch made out from industrial grade Polycarbonate material including making connection testing etc. as required.
269Providing & Fixing of IS:1293 marked of 3 pin 6 amp. flush type non modular socket CM/L no. printed and made out from industrial grade Polycarbonate material, brass terminal with Porcelain based back cover & captive screws including cutting hole in tile and making connection testing etc. as required.
270Providing & Fixing of IS:1293 3/6 pin 16 amp flush type non modular socket CM/L no. printed and made out from Industrial grade Polycarbonate material, brass terminal with Porcelain based back cover & captive screws including cutting hole in tile and making connection testing etc. as required.
271Providing & Fixing of ISI marked (IS:371) 6 amp surface type 3 pin ceiling rose with CM/L no. printed and made out from industrial grade Polycarbonate material, brass terminal & captive screws including making connection testing etc. as required.
272Providing & Fixing of ISI marked (IS:1258) batten/angle lamp holder with CM/L no. printed and made out from industrial grade Polycarbonate material, brass terminal & captive screws including making connection testing etc. as required.
273Providing & Fixing of ISI marked (IS:1293) 6 amp unbreakable 3 pin plug top having lamp indicator with CM/L no. printed and made out from industrial grade Polycarbonate material, brass terminal including making connection testing etc. as required.
274Providing & Fixing of ISI marked (IS:1293) 16 amp unbreakable 3 pin plug top having lamp indicator with CM/L no. printed and made out from industrial grade Polycarbonate material, brass terminal including making connection testing etc. as required.
275Providing & Fixing of flush type non modular 2 pin telephone socket with plug top made out from industrial grade Polycarbonate material, brass terminals including making connection testing etc. as required.
276Providing & Fixing of flush type non modular single line telephone jack made out from industrial grade Polycarbonate material, including making connection testing etc. as required.
277Providing & Fixing of flush type non modular double line telephone jack made out from industrial grade Polycarbonate materialincluding making connection testing etc. as required.
278Providing & Fixing of flush type non modular coaxial T.V. socket made out from industrial grade Polycarbonate material,including making connection testing etc. as required.
279Providing & Fixing of IS 11037 marked non modular socket size flush type 100 watt rotary minimum 5 step fan regulator with CM/L no. printed and made out from industrial grade Polycarbonate material including making connection testing etc. as required.
280P & F ISI marked 32 A D.P. switch with fuse and indicating lamp including making connection testing etc. as required.
281Providing & Fixing of ISI marked (IS:302) gong bell with CM/L no. printed including making connection testing etc. as required.
282Providing & Fixing of single / multi tone electronic call bell / remote bell including making connection testing etc. as required.
283Providing & Fixing of ISI marked (IS:302) ding dong/musical chime bell including making connection testing etc. as required.
284Providing & Fixing of modular type switch/ bell push duly ISI marked (IS :3854) with CM/L no. printed and made out of unbreakable and fire retardant virgin UV Stabilized Polycarbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating ,minimum width of switch toggle( PUSH PART ) should not less then 20mm, including making connections, testing etc as required.
28510 A one way switch
28610 A two way switch
28716 A one way switch 1M
28820 A one way switch 1M
28920 A one way switch 2M
29016 Amp. 2 Module switch With Led Indicator
29132 Amp. 2 Module switch With Led Indicator
292Providing & Fixing of IS:1293 marked modular type lockable feature socket with CM/L no. printed duly made out of unbreakable and fire retardant virgin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating, including making connections, testing etc as required.
2936 A 3 pin shuttered socket
2946/16 A shuttered socket
29513 A flat pin international socket (Non ISI)
296Providing & Fixing of modular type 100W Step Fan regulator duly ISI marked (IS 11037) with CM/L no. printed made out of unbreakable and fire retardant virgin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , including making connections, testing etc as required.
2975 step fan regulator 2 Module
298Providing & Fixing of following modular accessories, made out of unbreakable and fire retardant virgin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating, including making connections, testing etc as required.
299RJ-11 telephone jack single line
300RJ-11 telephone jack Double line
301USB Charger 2 A - 1 M with BIS mark
302RJ-45, Cat 6 computer jack with shutter
303T.V. coaxial socket
304Blanking plate
30525 Amp. 2 Module Motor Starter with on / off Push button
306LED Skirting /Foot Light 2 Module
307Electronic Chime/Buzzer 2M
308Modular MCB 6 A to 32 A SP
309Modular MCB 6 A to 32 A DP
310Providing & Fixing of following size mounting grid plates with cover plates made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect.
3111/2 Module
3123 Module
3134 Module
3145 Module
3156 Module
3168 Module
31710 Module
31812 Module
31916/18 Module
320Providing & Fixing of Hot dipped Galvanized metal box of 1.2 mm thick with earthing terminal and adjustable floating clamp in recess/ surface suitable for modular accessories as required.
3211-2 Module
3223 Module
3234-5 Module
3246-8 Module
32510-12 Module
32616/18 Module
327Providing & Fixing of Wiring Accessories OEM fabricated following size virgin material UPVC modular boxes on surface suitable for modular accessories as required.
3281-2 Module
3293 Module
3304/5 Module
3316 / 8 module
33210 / 12 module
333Providing & Fixing of Multiple socket with surge and spikes protection cartridge not less then 5 KV with minimum four nos. universal 6 A sockets, one 6 A switch and 3 pin company fitted plug top and 3 core multistrand copper lead minimum 1.5 mtr. including making connection etc as required.
334Providing & Fixing of DLP PVC adaptable trunking system for cable management including finishing accessories like corners, tees, adjustable angles, junction etc. as required . The trunking system shall have adaptable system for modular type RJ 45 data socket/ wiring accessories/ power sockets and shall be covered with peal off plastic cover. OEM have to submit NABL accrediated /CPET lab test reports /EN 50085-2-1 complaince certificate.
33580mm x 50mm
336100/105mm x 50mm
337150/160mm x 50mm
338195/200mm x 50mm
339Providing and fixing of power plug point with non modular accessories with Galvanized box of 1.2 mm thick with earth terminal with suitable size 3.0 mm thick phenolic laminated sheet (IS : 2036 - 1995) cover including cost of 16 amp. Switch (IS :3854) and 3/6 pin 16 amp. socket outlet making connection , testing , etc. as required.
340Supplying and fixing of power plug point with Modular accessories on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost of ISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required.
341P & F Krone module with base frame in the recess / surface made out of 1.2 mm thick sheet steel box, front openable, having locking arrangements duly powder coated ,including dressing, ferruling and punching of telephone cable with krone tool etc. as required.
34210 Pairs
34320 Pairs
34450 Pairs
345100 Pairs
346200 Pairs
347SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and Other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-
348(a) Thickness of CRCA sheet shall not be less than 1.6 mm upto 450 mm length/ width of any compartment and be 2.0 mm above 450 mm, load bearing structure shall be 2.0 mm thick sheet supported by base M.S. channel if required, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided
349(b) complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side(Inner & Outer side) of panel. The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.
350[c) Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only. All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar / Flexible wire for Interconnection between Main busbar and Switchgear is to be Paid Extra )
351(d) Wiring between components within switchgear and Incoming / outgoing cable shall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram.
352(e) All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.
353(f) Floor mounted panel shall be mounted on Base frame of ISMC channel size 100 x 50 x 5 mm ( to be paid Extra )
354(g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out.
355(h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI type Test certificates for Temp. rise test, Short circuit test for 50 kA and IP test is to be submitted)
356Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulator, with short circuit withstand capacity of 31 MVA for 1 Sec. , high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves.
357Electrolytic grade Aluminium bus bar 6010 grade
358Electrolytic grade (Cu+ETP) Tin Coated annealed copper bus bars IACS 100% grade.
359Providing & Fixing of IS: 13875 & IEC :61326/IEC:62053-22 confirming LED Digital type (up to 500) V range Volt meter / Direct- Ammeter / CT opertated ammeter/ Frequency meter / KWH meter / Multi Function Meter / Power analyzer of class 1 accuracy of size 96mm x 96 mm including making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required.
360Single Phase Ammeter
361Single Phase Voltmeter
362Three phase Ammeter with Inbuilt Selector Switch
363Three phase Voltmeter with Inbuilt Selector Switch
364Three phase KWH Meter
365Three phase KWH Meter Dual Source
366Frequency Meter
367Three phase AMP+HZ+PF+KW+KVA+KVAR+T.ENERGY+THD-I, THD-V & RUN HRS Meter
368Three phase AMP + HZ + PF + KW + KVA + KVAR + KVARH+KWH+DUAL ENERGY+ ENERGY+THD-I, THD-V & RUN HRS Meter
369Three phase with universal Auxiliary supply + AMP + HZ + PF + KW + KVA + KVAR + KVARH + KWH + DUAL ENERGY+ ENERGY+THD-I, THD-V & RUN HRS + MD with RS485 Meter
370Providing & Fixing of Current Transformer confirming IS 2705-I (1992) with secondary terminal and shorting Block , with all necessary support in existing panel including connection etc. as required Current transformer Ring Type Tape Wound/Resin Cast Wound Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required .
371Ring type tape wound CT
372C T Class 1, Ratio up to 150/5, Burden 5 VA
373C T Class 1, Ratio 200/5 to 600/5, Burden 10 VA
374C T Class 1, Ratio 800/5 to 1200/5, Burden 15 VA
375C T Class 1, Ratio 1500/5 to 3000/5, Burden 15 VA
376C T Class 1, Ratio 3200/5 to 5000/5, Burden 15 VA
377Resin cast wound type CT
378C T Class 1, Ratio up to 150/5, Burden 5 VA
379C T Class 1, Ratio 200/5 to 600/5, Burden 15 VA
380C T Class 1, Ratio 800/5 to 1200/5, Burden 15 VA
381C T Class 1, Ratio 1600/5 to 3000/5, Burden 15 VA
382C T Class 1, Ratio 4000/5 to 5000/5, Burden 15 VA
383Providing & Fixing of selector switch of 10 A for voltmeter using high grade engineering material to international standards with cam assembly insulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided . contact assembly is of operating temp range 25 degree C to 55 degree C, frequency upto 10 KHz. Switch life under standard operating conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour including making connection etc. as required .
384Voltage Between Phases with OFF ( 4 Position )
385Voltage Between Phases & Individual Phases to Neutral with OFF ( 7 Position )
386Providing & Fixing of CT linked selector switch of 10 A for Ampere meter (4 position ) using high grade engineering material to international standards with cam assembly insulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided . contact assembly is of operating temp range 25 degree C to 55 degree C, frequency upto 10 KHz. switch life under standard operating conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour , including making connection etc. as required .
387Providing & Fixing of 10 A Cam operated rotary (Local- Remote, Auto - manual) switches on existing panel with 1 pole 2 way and off position using high grade engineering material to international standards with cam assembly insulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided . contact assembly is of operating temp range -25 degree C to 55 degree C, frequency upto 10 KHz. switch life under std. op. conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour including making connection etc. as required .
388All in all comprehensive maintenance of mono block / submersible motor pump set with starter panel etc. complete in all respect
389Sub mersible Motor pump set
390Rewinding of ceiling fan motor (starting and running winding) including all necessary material. The motor is to be wound taking no. of coils, turns and pitch as it was originally wound with required size super enamelled wire with 'E' class insulation material and making connections etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. (New model ceiling fan)
391900/1200 mm sweep (New model ceiling fan)
392Labour charges for removing and refixing of Ceiling fan/ Exhaust fan from site
393Providing & Fixing of Electrical insulating rubber matts confirming to IS: 15652 / 2006 with one side anti skid aberration marks and pasting the mat with synthetic rubber adhesive as required.
3943.3 KV, class A 2 mm thick with proof voltage 10 KV AC (rms) and Break Down Voltage 30 KV AC (rms)
39511 KV, Class B 2.5 mm thick with proof voltage 22 KV AC (rms) and Break Down Voltage 45 KV AC (rms)
396Providing & Fixing of self healing IP20 MPP type shunt capacitor (banks) conforming to IS:13340-41 / IEC :831-1&2 OR IEC : 60831-1& 2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( PSD ) and shall have dissipation factor less than 0.0025 at 50 Hz, Operating loss less than 0.30 Watt per KVAR. Min over current capacity 1.8 times rated current & peak inrush current min. 300 times of rated current, life expectancy greater than 100000hrs (temp class - 25 D) in 440 V including making connections, testing etc. as required.
397Heavy duty Three phase 440 V, 50 Hz cylindrical type capacitor (Bank)
398Heavy duty Three phase 525V, 50 Hz cylindrical type capacitor (Bank)
399Providing & Fixing of 3-Phase 415/440 V , 7 % / 14 % Detuned Reactors conforming to IEC 61558-2-20 & IEC 60076-6 Aluminium wound for harmonics filter with 180% to 200 % Linearity, H - Class Insulation ( 180 degree C), high temp. Disconnection above 155 deg C., ambient temperature: +60 deg C. with thermal cut off switch in existing panel with following Capacitor ratings. including making connections, testing etc. as required.
4007 % (189 Hz) Aluminium wound Reactors
401For 1 to 5 KVAR capacitor
40210 KVAR
40312.5 KVAR
40415 KVAR
40520 KVAR
40625 KVAR
40750 KVAR
408100 KVAR
40914 % (133 Hz) Aluminium wound Reactors
410For 1 to 5 KVAR capacitor
41110 KVAR
41212.5 KVAR
41315 KVAR
41420 KVAR
41525 KVAR
41650 KVAR
417100 KVAR
418Providing & Fixing of microprocessor based 3 CT’s for all 3 phase sensing compensation power factor correction relay with Approx. Size 139 mm x 139 mm, Operating Voltage 415/440 V , IEC / EN 61000-6-(2&4) having 3 CT sensing, sensitivity up to 50 milli amp secondary current , self analyzing auto c/k setting according to targeted power factor setting, the relay shall have digit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, High voltage, THD-I & THD-V insufficient compensation, communication interface with RS 485, indication of switching on units, auto/manual status, and shall have over load protection, no volt release , having multi Built in MFM with PF Controller LCD Display, CT polarity auto correction % THD up to 30 harmonics level, step switching time 2 sec to 1800 sec. Lead & Lag parameters, metering facility and 3 no. Class- 0.5 Cast Resin CT for sensing the relay including making connection with 1.5 Sq.mm copper wire etc. as required.
4196 to 8 stage
42012 to 16 stage
421Providing & Fixing of AC operated heavy duty 230 /440 Volt power contactor confirming to IS/IEC 60947-4-1 : 2000 having provision of mechanical interlocking, auxilary contacts, Din rail mounting type including making connections, testing etc. as required.
4224 pole Power contactors with following AC 1 Rating
42316 Amp.
42425/32 Amp.
42540 Amp
42650/55 Amp
42763 Amp
428100/105 Amp
429160 Amp
430200 Amp
431250 Amp
432325 Amp
433Providing & Fixing of 440 Volt 3 pole capacitor (AC 6 B ) duty contactor with 3 no. early make and post break auxiliary contacts in series with quick discharge damping resistors/ reactors to limit the inrush current as per IS/IEC 60947-4-1 : 2000, insulation voltage 1000V, impulse withstand voltage 8 KV,Din rail mounting type including making connections, testing etc. as required. suitable for following capacity capacitor bank.
434up to 6 KVAR
4358.5 KVAR
43610 KVAR
43712.5 KVAR
43815.0 KVAR
43920.0 KVAR
44025.0 KVAR
44130.0 KVAR
44240.0 KVAR
44350.0 KVAR
44460.0 KVAR
44575.0 KVAR
44685 KVAR
447100 KVAR
448P & F of Control relays (Auxiliary Contactor) for AC control standard. 24 V Coil 110, 240 V, 415 V, 50 Hz conforming to IS:13947-4-1/IEC:60947-4-1 with required NO & NC combination including making connections, testing etc. as required.
449P & F of Front / Side mounting Add on Auxiliary Contact Block with required NO & NC combination including making connections, testing etc. as required.
450Providing & Fixing of thermal over load relay with built in single phase protection and having at least 1NO & 1NC contacts, manual /auto reset facility including making connection testing etc. as required.
451Up to 14 Amp
45214 to 23 Amp
45320 to 33 Amp
45424 to 40 Amp
455P & F of 240 / 415 V Electronic ON - OFF Timer 3 -30 Sec / 12 - 120 Sec including making Connection etc. as required.
456Providing & Fixing of Electromechanical / digital time switch having following day / week programme and minimum 100 hours reserve and AC1 rating of 16-20 amperes including making connection, programming conforming to IEC 60730-1 and 60730-2-7 etc. as required.
457One day reserve (Electromechanical type )
458One day & week reserve (digital type )
459Providing & Fixing of 110 - 240 V, AC, 1 ph. , 2 W Astronomical time switch with surge suppressor, memory card, Sunrise / Sunset selectable, software for programming including making connection, etc. as required.
460Providing & Fixing of IP54 direct or CT operated, 1x240 / 3x240 volts , 50 Hz static watt-hour meter (kwh) , having resolution 0.1 / 0.01 kwh , confirming to IS:13779/ IS:15959, LED indicators for tamper operation ( Reverse &/or earth connection) , pulsating LED indicator for meterology , LCD Display, cover plate for body and terminal sealing , push button for all standard parameters, including making connection ,testing etc. as required.
461up to 30 ampere single phase meter acc. Cl 1
46210 A to 60 ampere Single phase meter acc. Cl 1
4633ph, 4W KWh CT Operated Base mounting 240 V-/5A acc. Cl 0.5s
4643ph, 4W KWh Direct Base mounting 240 V 10-60 Amp acc. Cl 1
4653ph, 4W Trivector Meter,240 V(L-N) 5A acc. Cl 0.5
466P & F of Direct on line (DOL) / Star - Delta Starter as per IEC type-2 Co-ordination chart of OEM in Existing Panel with circuit breaker having inbuilt overload protection or separate thermal Overload relay , Short circuit, phase loss protection, suitable Contactors, including wiring between switchgears, Indicating lamps for R,Y,B,ON,OFF, Push button for ON, OFF, Volt meter, Ammeter, selector switch for local/remote, auto/manual/OFF operation. Cast resin CT's, provision for potential free contacts making connection, testing etc. as required.
467Direct on line (DOL) Starter with following Motor rating
468Motor rating 0.55 KW
469Motor rating 0.75 KW
470Motor rating 1.5 KW
471Motor rating 2.2 KW
472Motor rating 4.0 KW
473Motor rating 5.5 KW
474Motor rating 7.5 KW
475SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation from 50 to 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 690V. provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle ( to be paid extra) , including making connections etc. as required. OEM shall have submit NABL / CPRI / ERDA/ Intertek accrediated lab type test certificate.
4763 pole MCCB With Thermal Magnetic release
477up to 100 Amp , 10 kA, fixed O/L & fixed S/C setting
478up to 100 Amp , 25 kA, adjustable O/L & Fixed S/C setting,
479125 Amp , 25 kA, adjustable O/L & fixed S/C setting,
480160 Amp , 25 kA, adjustable O/L & fixed S/C setting,
481200 Amp , 25 kA, adjustable O/L & fixed S/C setting,
482250 Amp , 25 kA, adjustable O/L & adjustable S/C setting,
483250 Amp , 35 kA, adjustable O/L & adjustable S/C setting,
484400 Amp , 35 kA, adjustable O/L & adjustable S/C setting,
485Providing & Laying XLPE insulated & P.V.C. sheathed Armoured Aluminium cable confirming to IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing commissioning etc. as required of following size.
4864.0 Sq. mm
4872 core
4883 core
4894 core
4906.0 Sq. mm
4912 core
4923 core
4934 core
49410.0 Sq. mm
4952 core
4963 core
4974 core
49816.0 Sq. mm
4992 core
5003 core
5014 core
50225.0 Sq. mm
5032 core
5043 core
5053.5 core
50635.0 Sq. mm
5072 core
5083 core
5093.5 core
51050.0 Sq. mm
5112 core
5123 core
5133.5 core
51470.0 Sq. mm
5151 core
5162 core
5173 core
5183.5 core
51995.0 Sq. mm
5201 core
5213.5 core
522120.0 Sq. mm
5233.5 core
524185.0 Sq. mm
5253.5 core
526240.0 Sq. mm
5273.5 core
528Excavation of trench of size 75 cm (Depth) x 35 cm(Width) for laying of suitable no. of LT cables (Inter spacing between cables should not be less than 2 D) in ground with following procedure :- (a) Make a river sand bed of height 100 mm along the trench, (b) Lay the cable in the middle of the trench, (c) Provide river sand bed of height 100 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thickness and 225 mm wide just above the sand bed vertically across the cable, (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth.
529Add Extra in Item no.11.5 if Excavation done in Hard Rock / CC road / TAR Road and making Good the same
530Excavation of trench of size additional 20 cm in width, with procedure as per following points :- (a) Make a river sand bed of height 100 mm along the trench, (b) Lay another cable in middle of trench in such manner that spacing between another cable is 20 cm., (c) Provide river sand bed of height 100 mm on top of the cable. (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 /Sand stone slabs of 50 mm thickness and 225 mm wide just above the sand bed vertically (Longest side is vertical to cable) along the cable , (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth
531Add Extra in Item no. 11.7 if Excavation done in Hard Rock / CC road / TAR Road and making Good the same
532Add Extra in item no. 11.1 to 11.4 for Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
533Up to 35 Sq.mm fixed with 25 mm x 2 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps.
534Above 35 sq. mm and upto 95 sq. mm fixed with 40 mm x 3 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps.
535Above 95 sq. mm and upto 185 sq. mm fixed with 40 mm x 4 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps.
536Above 185 sq. mm and upto 400 sq. mm fixed with 50 mm x 5 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps.
537Add extra in item no. 11.1 to 11.4 for Laying Charges for cable through Manual Boggi by making pit at regular interval and repairing the pit after laying of cable with PCC/ Bitumin as required.
538Add Extra in item no. 11.1 to 11.4 for Laying Charges for cable through Vermeer machine by making pit at regular interval and repairing the pit after laying of cable with PCC/ Bitumin as required.
539Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring, Compression Nut, heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape as per IS 8337-1976 of following size of PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required.
5402 x 4.0 sq.mm
5412 x 6.0 sq.mm
5422 x 10.0 sq.mm
5432 x 16.0 sq.mm
5442 x 25.0 sq.mm
5452 x 35.0 sq.mm
5462 x 50.0 sq.mm
5472 x 70.0 sq.mm
5483 x 4.0 sq.mm
5493 x 6.0 sq.mm
5503 x 10.0 sq.mm
5513 x 16.0 sq.mm
5523 x 25.0 sq.mm
5533 x 35.0 sq.mm
5543 x 50.0 sq.mm
5553 x 70.0 sq.mm
5563.5 x 25.0 sq.mm
5573.5 x 35.0 sq.mm
5583.5 x 50.0 sq.mm
5593.5 x 70.0 sq.mm
5603.5 x 95.0 sq.mm
5613.5 x 120.0 sq.mm
5623.5 x 150.0 sq.mm
5633.5 x 185.0 sq.mm
5643.5 x 240.0 sq.mm
5653.5 x 300.0 sq.mm
5663.5 x 400.0 sq.mm
567Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring, Compression Nut, heavy duty Copper lugs (IS 8337- 1976) duly crimped with crimping tool, PVC tape for following size of PVC insulated & PVC sheathed/ XLPE copper conductor cable of 1100 volt grade as required.
5681 x 16.0 sq.mm
5691 x 25.0 sq.mm
5701 x 35.0 sq.mm
5711 x 50.0 sq.mm
5721 x 70.0 sq.mm
5731 x 95.0 sq.mm
5741 x 120.0 sq.mm
5752 x 4.0 sq.mm
5762 x 6.0 sq.mm
5772 x 10.0 sq.mm
5782 x 16.0 sq.mm
5792 x 25.0 sq.mm
5802 x 35.0 sq.mm
5812 x 50.0 sq.mm
5822 x 70.0 sq.mm
5832 x 95.0 sq.mm
5842 x 120.0 sq.mm
5853 x 1.5 sq.mm
5863 x 2.5 sq.mm
5873 x 4.0 sq.mm
5883 x 6.0 sq.mm
5893 x 10.0 sq.mm
5903 x 16.0 sq.mm
5913 x 25.0 sq.mm
5923 x 35.0 sq.mm
5933 x 50.0 sq.mm
5943 x 70.0 sq.mm
5953 x 95.0 sq.mm
5963 x 120.0 sq.mm
5974 x 1.5 sq.mm
5984 x 2.5 sq.mm
5994 x 4.0 sq.mm
6004 x 6.0 sq.mm
6014 x 10.0 sq.mm
6024 x 16.0 sq.mm
6034 x 25.0 sq.mm
6044 x 35.0 sq.mm
6054 x 50.0 sq.mm
6064 x 70.0 sq.mm
6074 x 95.0 sq.mm
6084 x 120.0 sq.mm
6096 x 1.5 sq.mm
6106 x 2.5 sq.mm
6118 x 1.5 sq.mm
6128 x 2.5 sq.mm
61310 x 1.5 sq.mm
61410 x 2.5 sq.mm
61512 x 1.5 sq.mm
61612 x 2.5 sq.mm
617Supplying and making end termination with heavy aluminium lugs ( Pin / ring type ) confirming to IS 8309 -1993 duly crimped with crimping tool, PVC tape etc of following size.
6181.5 Sq.mm
6192.5 Sq.mm
6204.0 Sq.mm
6216.0 Sq.mm
62210.0 Sq.mm
62316.0 Sq.mm
62425.0 Sq.mm
62535.0 Sq.mm
62650.0 Sq.mm
62770.0 Sq.mm
62895.0 Sq.mm
629120.0 Sq.mm
630150.0 Sq.mm
631185.0 Sq.mm
632240.0 Sq.mm
633300.0 Sq.mm
634400.0 Sq.mm
635500.0 Sq.mm
636630.0 Sq.mm
637800.0 Sq.mm
6381000.0 Sq.mm
639Supplying and making end termination with heavy duty Copper lugs ( ANY type ) confirming to IS 8309 -1993 duly crimped with crimping tool, PVC tape etc of following size.
6401.5 Sq.mm
6412.5 Sq.mm
6424.0 Sq.mm
6436.0 Sq.mm
64410.0 Sq.mm
64516.0 Sq.mm
64625.0 Sq.mm
64735.0 Sq.mm
64850.0 Sq.mm
64970.0 Sq.mm
65095.0 Sq.mm
651120.0 Sq.mm
652Supply, Fabricating & installing following sizes of perforated Hot dipped Galvanized iron cable tray ( Galvanized thickness not less then 50 microns) with perforation not more then 17.5% in convenient section including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with GI suspenders including GI bolts & nuts , fastners, supports etc. as required.
653100mm x 50mm x 1.6mm
654150mm x 50mm x 1.6mm
655225mm x 50mm x 1.6mm
656300mm x 50mm x 1.6mm
657Supply, Fabricating & installing following sizes of perforated Powder coated MS cable tray with perforation not more then 17.5% in convenient section including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with GI suspenders including GI bolts & nuts , fastners, supports etc. as required.
658100mm x 50mm x 1.6mm
659150mm x 50mm x 1.6mm
660225mm x 50mm x 1.6mm
661300mm x 50mm x 1.6mm
662375mm x 50mm x 2.0mm
663S & Making Heat shrinkable type Tubular sleeve version outdoor straight through joint for following size of PVC/ XLPE insulated aluminium conductor cable of 1.1 KV grade as required.
6641 x 25 sq.mm-50 sq.mm
6651 x 70 sq.mm-150 sq.mm
6661 x 185 sq.mm-300 sq.mm
6671 x 400 sq.mm
6681 x 500 sq.mm
6691 x 630 sq.mm
6701 x 800 sq.mm
6711 x 1000 sq.mm
6722 x 1.5 sq.mm-6 sq.mm
6732 x 10.0-16.0 sq.mm
6742 x 25.0 sq.mm-50 sq.mm
6752 x 70.0 sq.mm-150 sq.mm
6762 x 185.0 sq.mm-300 sq.mm
6772 x 400 sq.mm
6782 x500 sq.mm
6793/3.5/4 x 1.5 sq.mm-6 sq.mm
6803/3.5/4 x 10.0-16.0 sq.mm
6813/3.5/4 x 25.0 sq.mm-50 sq.mm
6823/3.5/4 x 70.0 sq.mm-150 sq.mm
6833/3.5/4 x 185.0 sq.mm-300 sq.mm
6843/3.5/4 x 400 sq.mm
6853/3.5/4 x500 sq.mm
686S/F cable route marker with 10cm x 10cm x 5mm thick or 10 cm dia. G.I.plate with inscription thereon, bolted/welded to 35mm x 35mm x 5mm angle iron, 60cm long and fixing the same in ground in C C ( 1:3:6 ) as required
687P / L of Double wall corrugated HDPE pipe confirming to IS : 16205 P-24, Stiffness Class 750 N, Externally corrugated and having smooth surface inside with HDPE Coupler, Elbow, Tee at required Depth below the ground for laying cable of following Nominal Outer dia. MFR Test report from NABL accrediated is to be submitted.(Excavation of trench, CC Haunching, Back filling of Earth with compaction is to be Paid Extra).
68850 mm
68963 mm
69075 mm
69190 mm
692110 mm
693120 mm
694160 mm
695200 mm
696Providing & Laying XLPE insulated three core Armoured Aluminium cable for working voltage 11 K.V.(E) confirming IS :7098 P - 2 with H4- Grade electrolytic aluminium conductor confirming to IS: 8130 class-2 of purity >99.6 %, Insulation Screening: Extruded Semiconducting Compound followed by helically wrapped Copper Tape, round / flat strip armouring of cables , Inner / outer sheath PVC type ST-2 confirming to IS:5831 in existing RCC pipe / Hume Pipe/ Stoneware Pipe/ PVC pipe/ open duct/cable trench / Cable tray (with cable tie) including testing etc. as required of following size.
6973 core 95.0 Sq.mm
6983 core 120.0 Sq.mm
6993 core 150.0 Sq.mm
7003 core 185.0 Sq.mm
7013 core 240.0 Sq.mm
7023 core 300.0 Sq.mm
703Providing & Laying XLPE insulated three core Armoured Aluminium cable for working voltage 33 K.V.(E) confirming IS :7098 P - 2 with H4- Grade electrolytic aluminium conductor confirming to IS: 8130 class-2 of purity >99.6 %, Insulation Screening: Extruded Semiconducting Compound followed by helically wrapped Copper Tape, round / flat strip armouring of cables , Inner / outer sheath PVC type ST-2 confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray (with cable tie) including testing etc. as required of following size.
7043 core 150.0 Sq.mm
7053 core 185.0 Sq.mm
7063 core 240.0 Sq.mm
7073 core 300.0 Sq.mm
708Excavation of trench of size 120 cm (Depth) x 35 cm(Width) for Laying of suitable no. of HT cable( Inter spacing between cables should not be less than 2 D) in ground with following procedure:- (a) Make a river sand bed of height 125 mm along the trench, (b) Lay the cable in the middle of the trench, (c) Provide river sand bed of height 125 mm on top of the cable. (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thickness and 225 mm wide just above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth
709Add Extra in Item no. 13.3 if Excavation done in Hard Rock / CC road / TAR Road and making Good the same
710Add Extra for Laying of one number additional XLPE power cable of 11/33 KV (Earthed) voltage grade direct in ground in the same trench in one tier horizontal formation including excavation of trench of size additional 20 cm in width, with procedure as per following points:- (a) Make a river sand bed of height 125 mm along the trench, (b) Lay another cable in middle of trench in such manner that spacing between another cable is 20 cm, (c) Provide sand bed of height 125 mm on top of the cable. (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thickness and 225 mm wide just above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.) (e) Backfill the excavated soil leaving 300 mm from the Ground level. (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth
711Add Extra in Item no. 13.5 if Excavation done in Hard Rock / CC road / TAR Road and making Good the same
712Providing & making heat shrinkable type indoor/outdoor/straight through terminations/ joint kit suitable for 11 KV / 33 KV (Earthed) cable with required components, prepration of cable ends. Type test report should be as per IS13573:2011 including testing etc. as required of following sizes.
71311 KV End Termination Kit Indoor type
7143 core up to 35 Sqmm
7153 core 50/70/95 Sq.mm
7163 core 120/150/185 Sq.mm
7173 core 240/300 Sq.mm
7183 core 400 Sq.mm
71911 KV End Termination Kit Outdoor type
7203 core up to 35 Sqmm
7213 core 50/70/95 Sq.mm
7223 core 120/150/185 Sq.mm
7233 core 240/300 Sq.mm
7243 core 400 Sq.mm
72511 KV Straight Through Joint Kit
7263 core up to 35 Sq.mm
7273 core 50/70/95 Sq.mm
7283 core 120/150/185 Sq.mm
7293 core 240/300 Sq.mm
7303 core 400 Sq.mm
731Pipe Earthing as per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. ' B ' class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS : 1387 with perforated holes of 12 mm dia ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, Heavy duty weather proof poly-propylene earth inspection chamber as per requirement of IS/IEC 62305 and tested as per IEC 62561-5 with lockable Jam free lid suitable for safe working load 60 kN of round / square size 250 mm, and Height 250 to 300 mm and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required.
732Plate Earthing as per IS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, Heavy duty weather proof poly-propylene earth inspection chamber as per requirement of IS/IEC 62305 and tested as per IEC 62561-5 with lockable Jam free lid suitable for safe working load 60 kN of round / square size 250 mm, and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required.
733Plate Earthing as per IS:3043 with copper Earth plate of purity >95% of size 600mm x 600mm x 3.0mm by embodying 3 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, Heavy duty weather proof poly-propylene earth inspection chamber as per requirement of IS/IEC 62305 and tested as per IEC 62561-5 with lockable Jam free lid suitable for safe working load 60 kN of round / square size 250 mm, and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required.
734SITC of Copper Bonded rod Earthing with high tensile strength (more than 600 N / sq.mm low carbon steel rod molecularly bonded with Copper thickness (250 microns) and confirming to UL 467 of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :-
735(a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole
736(b)Earth enhancing compound to ensure the moisture content and electrical conductivity, 25 kg for 3000 mm. The compound shall be tested form NABL accredited lab for low resistivity (less than 0.12 Ohm - meter) & high conductivity in nature with carbon as a major content in accordance with IEC 62561-7
737© Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt
738(d) Place Heavy duty weather proof poly-propylene earth inspection chamber as per requirement of IS/IEC 62305 and tested as per IEC 62561-5 with lockable Jam free lid suitable for safe working load 60 kN of round / square size 250 mm, and Height 250 to 300 mm.
739(e) Testing of earth resistance for value of 5 ohms or less as required.
740(f) Test certificates for confirming above standards from OEM is mandatory.
74117.2 mm thick and 3 Mtr. Long
74225 mm thick and 3 Mtr. Long
743Supply & Laying following size earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/ soldering/ welding, Jointing shall be done by overlapping double the width of strip and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.
74420mm x 3mm copper strip
74525mm x 3mm copper strip
74620mm x 3mm G.I. ( Hot Dipped ) Strip
74725mm x 3mm G.I. ( Hot Dipped ) Strip
748Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu purity purity >95% thimble etc. as required.
7496 SWG tinned copper Wire
7508 SWG tinned copper Wire
75110 SWG tinned copper. Wire
7526 SWG copper Wire
7538 SWG copper Wire
754Supply & Laying following size' B ' class , G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with accessories like bend, socket etc. for laying earth conductor/ strip / cable in ground/ surface/ recess as required. (Earth Excavation will be Paid Extra)
75515 mm dia.
75620 mm dia.
75725 mm dia.
75832mm dia
759Making of hole in wall (brick/stone) of required and placing NP-2 RCC pipe ring of required size for housing exhaust fan and making good the same, with cement plaster required of following size.
760Up to 457 mm size
761more than 457 mm & up to 610 mm
762Supply & Fixing of phenolic laminated board of 6.0 mm thick for fresh air fan/exhaust fan up to size of 300 mm on existing window frame including cost of board, cutting of hole , Nut bolts etc. as required.
763Providing & Fixing of BEE Star rated copper wounded with class of Insulation 'F', double ball bearing capacitor start, aluminium body & aluminium blade ceiling fan conforming to all the performance requirements laid down in IS 374:2019 with down rod up to 30 cm with secondary support safety cable ( steel rope) , cotter pin, shackle kit with 3 x 1.5 sq.mm pvc insulated flexible copper conductor and making connection testing etc. as required.
7641200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 )
765Providing & Fixing of shackle (iron hook) made from 2mm nominal thick CRCA sheet and bolts (2nos) of 6mm with spring washer nut, checknut & split pin as required.
766Providing & Fixing of of M.S. J- hook of standard design made out of 16 mm dia. M.S. round bar and fixed with cement concrete mortar with required support as required.
767P & F 1.2 mm thick M.S. Recessed fan box and top lid screwed on Box, hexagonal/ round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 150 mm length extended on each side as required.
768Providing & Fixing of of Double ball bearing, copper wounded capacitor start single phase metallic blade fresh air fan, in existing opening including cost of hardware , flexible 3 core 1.5 Sq.mm copper conductor ,making connections, testing etc. as required.
769230 mm sweep, Minimum air delivery 750 Cum / hour
770300 mm sweep Minimum air delivery 1600 Cum / hour
771Providing & Fixing of Heavy duty capacitor start, copper wound Double ball bearing 900/1400 RPM single phase Exhaust fan conforming to IS:2312 marked in existing opening including making connections testing etc. as required.
772300 mm sweep(900 RPM)
773380 mm sweep(900 RPM)
774450 mm sweep(1400 RPM)
775Providing & Fixing of ventilating fans Capacitor start, copper wounded, single phase with PVC impeller, ABS body, automatic openable louver shutter in existing opening including making connection, testing etc. as required.
776150 mm sweep Minimum Air Delivery 150 Cum / hour
777200 mm sweep Minimum Air Delivery 450 Cum / hour
778250 mm sweep Minimum Air Delivery 750 Cum / hour
779Providing & Fixing of Wall mounting / Pedestal type Heavy duty Air Circulator , Double ball bearing and with metal sturdy mesh guard; Aluminium alloy one piece blade and conforming to IS:2997, including fixing with anchor bolts, making connection testing etc. as required.
780450 mm sweep Wall mounting and three speed regulator with Minimum Air Delivery 150 Cum. / Minute
781600 mm sweep Wall mounting with Minimum Air Delivery 270 Cum. / Minute
782Providing & Fixing of 450 mm Sweep Oscillating type Wall mounting / Pedestal type fans with Three speed, ON and OFF position, Sintered Iron bush oil impregnated, with metal front and back 120 or more ribs guard; Three no. Aluminium blades, minimum Air delivery 100 Cum. / Minute , Minimum Service Value 1.11 Cum./min/watt, noise level should be <= 75 dB, power consumption <= 120 watts, motor protection through thermal overload protection device, including fixing with anchor bolts, making connection testing etc. as required.
783Wall mounting type with Adjustable Vertical Angle
784Pedestal Type with Adjustable Height
785Providing & Fixing of extra down rod of 15 mm dia . ERW (Electrical resistance welded ) of 1.6mm nominal thick medium duty steel pipe including cutting, threading, drilling, fixing quarter pin etc as required.
786Providing & Fixing of 400 mm Sweep BLDC technology Oscillating type Wall mounting / Pedestal type fans with Three speed, ON and OFF position, Double Wall bearing with front and back 120 or more ribs guard; Three no. blades, noise level should be <= 75 dB, including fixing with anchor bolts, making connection testing etc. as required. ( With Remote )
787Wall mounting type with Service value 2.0 CMM /W, Min. Air Delivery 71 CMM
788P & F of Gravity Louver shutter of superior quality made out of frame of 18 swg M.S. sheet & Louvers made from 24 swg MS Sheet with enamel paint including cost of nuts, bolts, etc as required.
789Up to 380 mm size
790above 380 mm size
791Providing & Fixing BLDC technology step regulator compatible ceiling fan, with aluminium body & aluminium blade, power factor not less then 0.9 , following service value (CMM/W) , with following air delivery , speed 350 RPM ( tolerance as per IS:374 2019 ) THD less then 10%, copper winding with class of Insulation 'F' complete with with secondary support safety cable ( steel rope), down rod up to 30 cm, cotter pin, shackle kit with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required.
7921200 mm sweep with Air delivery >/= 230 CMM and Service Value 8.20
793S & F Extruded Aluminium Fresh Air / External Weather Louver, Small Format type with 38 mm flange width & 50 mm depth. finish - powder coated off white with aluminium mesh of required size.
794Providing & Fixing of Vertical(BEE 5 star rated) / Horizontal( BEE 3 star rated) storage water heater with outer casing made of Engineering Plastic sheet (Upto 25 Ltr) / Metal rust proof Body (35 & 50 Ltr), Glass - line / Titanium Enamel coated Pressure Pump Compatible 8 bar pressure Inner tank, Glass Line Coated , mineral filled heating element, stem type, snap action adjustable thermostat , Dual indicating lamps Injected PUF insulation, Multi Function Valve etc. as required held in position with 2/4 no. 10/12 mm anchor Fastener, duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top , including making inlet, outlet Flexible alloy connection, testing etc. as required.
7956 Ltr.
79610 Ltr.
79715 Ltr.
79825 Ltr.
79935 Ltr.
80050 Ltr.
801Providing & Fixing of stem type ISI marked (IS 3017 / 85) snap action adjustable thermostat for storage water heater including making connection testing etc. complete in all respect.
802Providing & Fixing of stem type ISI marked (IS 3017 / 85) , snap action bipolar adjustable thermostat with built in auto thermal cut out for storage water heater including making connection testing etc. complete in all respect.
803Providing & Fixing 2 / 3 KW nickle plated, mineral filled heating element including making connection testing etc complete in all respect.
804Providing & Fixing of 2 / 3 KW Glass Line Coated , mineral filled heating element including making connection testing etc complete in all respect.
805Providing & Fixing of Multi safety valve of 8.5 bar capacity with built in drain, NRV, Vacuum release, Pressure release etc. as required complete in all respect.
806Providing & Fixing of Twin neon indicating lamp of superior quality for storage water heater complete in all respect.
807Providing & Fixing of 13 mm Brass with C.P. finished ISI marked angle valve for storage water heater as required complete in all respect.
808Providing & Fixing of heavy duty flexible alloy pipe for storage water heater for inlet and outlet of suitable length including the cost of nuts, washers etc complete in all respect.
809450 mm
810600 mm
811Charges for descaling of storage water heater including replacement of Multi Function Valve as required.
812Charges for Fixing of storage water heater including 10/12 mm Anchor fasteners of suitable size, testing, carrying from store to site,etc. as required.
813Providing & Fixing of 2.0 KW twin ceremic cartridge, Withstands temperatures up to 1000 C long lasting even in hard water including making connection testing etc complete in all respect.
814SITC of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminium housing with in built driver , System lumen efficacy ≥ 110 lm/Watt output only at CW (5700K to 6500K) , internal surge protection of 4.0 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required.
8151170mm(+/-10%) LED batten with min. lumen output 2200 lm
816570mm (+/-10%) batten with min. lumen output 1000 lm
8171170mm(+/-10%) LED batten with min. lumen output 4400 lm
818SITC of IP20 SMD Mid Power LED batten with integrated box (min.1200mmx40mmx60mm including reflector) with replacable driver fixture made from Powder coated Extruded aluminium housing ,Min. lumen output 4800 lm, System lumen efficacy ≥ 120 lm/Watt output nly at CW (5700K to 6500K), internal surge protection of 4.0 KV with Short & Open circuit protection,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required.
819SITC of IP-20 LED Recessed / Surface Mounted, Round / Square backlit & SMD Mid Power LED Downlight with power coated die-cast aluminum housing with UV Stabilized non yellowish Diffuser with BIS compliance 4.0 KV surge protected Isolated driver, with Short & Open circuit protection input 320VAC-48 hr protection, input 350VAC-2 hr protection), having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt,at CW (5700K to 6500K) , THD < 10 % , Pf.≥0.95, CRI >80, life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) as required.
820Recessed Mounting
821Minimum lumen output 600 lm (lumen efficacy ≥ 100 lm / watt)
822Minimum lumen output 1300 lm
823Minimum lumen output 1600 lm
824Minimum lumen output 1950 lm
825Minimum lumen output 2400 lm
826Surface Mounting (with extruded alumn. Housing )
827Minimum lumen output 600 lm (lumen efficacy ≥ 100 lm / watt)
828Minimum lumen output 1300 lm
829Minimum lumen output 1600 lm
830Minimum lumen output 1950 lm
831Minimum lumen output 2400 lm
832SITC of IP20, 2'x2' LED Surface/ Recessed mounting backlit & SMD Mid power type LED Light fixture not less than 35 mm housing depth made from CRCA sheet steel housing, high purity / transmissivity UV stabilized Non -yellowish diffuser for uniform light distribution. operating voltage range 140-285 V, HV cutoff - LV cutoff should be 300-100V . High efficiency with 4 KV internal surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection ( input 320VAC-48 hoursprotection,input 350VAC-2 hours protection) (Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required.
833Recessed Mounting
834Minimum lumen output 4320 lm
835Minimum lumen output 4800 lm
836Surface Mounting (Driver should be Inside the Luminaire)
837Minimum lumen output 4320 lm
838Minimum lumen output 4800 lm
839SITC of IP20, 1'X1' LED Surface/ Recessed mounting backlit & SMD Mid power type LED Light fixture not less than 35 mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution.operating voltage range 140-285 V, HV cutoff - LV cutoff should be 300-100V High efficiency with 4 KV internal surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection (Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required.
840Recessed Mounting
841Minimum lumen output 2880 lm
842Minimum lumen output 3600 lm
843Surface Mounting (Driver should be Inside the Luminaire)
844Minimum lumen output 2880 lm
845Minimum lumen output 3600 lm
846SITC of IP65 IK08 rated Integrated High power LED ( each LED between 3 to 5 watt power with secondary lencs on each LED) Highbay light fixture made from Pressure Die Cast Aluminium housing, UV stabilized PC Cover/ Toughened glass diffuser, potted driver, Eye bolt for mounting, system lumen efficacy ≥150 lm/Watt output , THD < 10% ,p.f.≥0.95,CRI >70 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and . surge protection 4 KV inbuilt & 10 KV external inside fixture as required.
847Minimum lumen output 12000 lm
848Minimum lumen output 15000 lm
849SITC of energy efficient /energy saving IP 20 LED direct retrofit Bulb in existing holder or fixture as required with system lumen efficacy ≥100 lm/Watt output ,pf 0.95 , CRI >70, minimum life time of minimum 25000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required.
8509 Watt
85115 Watt
85218/20 Watt
853SITC of IP 20 box made out from 1.0 mm thick CRCA sheet steel with depth of minimun 30 mm and finished with powder coating and suitable for mounting LED tube including side covers, holders , internal wiring to illuminate the single sided connection LED tube. ( Without tube).
854Suitable for 2' LED Tube shape fixture for single rod
855Suitable for 4' LED Tube shape fixture for single rod
856Suitable for 4' LED Tube shape fixture for double rod
857Supply and Fixing of Pole OEM fabricated hot dipped galvanised M.S. Overhang (48.3 X 3.25 mm) with cap ( 250x 88.9 / 114.3 x 3.25 mm) over the existing poles.
858Single arm overhang
859Double arm overhang
860Supply and erection of Galvanized Iron pole with galvanizing done in single dipping (Average coating thickness Minimum 65 Microns) continuously tapered poles having Octagonal / Circular/ Conical cross-sections designed to withstand the maximum wind speed as per IS 875, The pole shaft shall be made from sheet steel (HT Steel Conforming to grade S355JO) and confirming to BSEN 10025 and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. The welding of pole shaft shall be done by Submerged Arc Welding (SAW) process. pole shafts shall be provided with the rigid flange plate of suitable thickness (Fe 410 conforming to IS 226 / IS 2062) with provision for fixing 4 no. foundation bolts, The base plate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside.The octagonal Poles shall have hinged lockable door of approximate 500 mm length at the elevation of 500 mm from the Base plate with bakelite sheet having 6A SP MCB and 16 sqmm stud type connector ( 4 nos) inside the pole at door opening for cable connection of following length and dimension as per table P-01 for Octagonal & P-02 for Conical with base plate and foundation bolt on the Existing cement concrete foundation. To ensure quality of product it's entire manufacturing process starting from sheet cutting to galvanization sould be done under one premises.
861Poles with Octagonal/Conical Cross Section
8623 Mtr.
8637 Mtr.
864Add for supply and fixing of Pole OEM fabricated Galvanized Overhang of following size over the existing poles.
86588.9 mm OD x 3.25 mm thickness
866Supply installation testing & Commissioning of high mast lighting system (as per PLG 07 of ILP UK techinical report no 7 of ILE UK /IS:875 Part-1 – 2015//BSEN10025/and IS:2062 )consisting of totally hot dip galvanised by piecewise single dipped method high mast, lantern carriage suitable for up to 18 nos luminaries with welded arm (excluding luminares), mast head frame assembly with full cover, including 1 No. LED 15 Watts aviation obstruction light, double drum type self sustaining winch, integral power tool accessible from door with padlocking arrangement (winch motor with control circuit) hot dipped galvanised heavy duty pipe lightening finial, Stainless steel 6 mm dia. wire ropes (AISI 316, 7 / 19 costruction 3 no. rope for lantern carrage & 2 no. rope for winch assembly ) foundation bolt, torque limiter,EPR insulated PCP sheathed 5 core x 2.5 Sq.mm trailing cable, including outdoor type control panel for auto on / off, reverse / forward motor operation. The mast is constructed from mild steel plates (as per IS 5986 Gr. 510 ) cut and folded to form a polygonal section, telescopic jointed and welding as per BS 5135.etc. as required including cost of RCC Foundation as per OEM Design & Drawings . ( See table P - 04 for specs.) To ensure quality of the product, OEM Must have Type test certificate for wind tunnel test from IIT. Entire manufacturing process starting from sheet cutting to galvanization should be done under one premises Inhouse galvanizing plant shall have bath length not less then 12.0 mtr to ensure the quality of galvanization .
86712.5 Mtr HM (in 2 section) suitable for 6 No. Luminaries 2 no. rope for lantern carrage & 2 no. rope for winch assembly
86816.0 Mtr HM (in 2 section)
86920.0 Mtr Hm (in 2 section)
870Providing and Laying RCC Foundation for Octagonal / Conical Street Light poles as per Drawing attach at Table P-05 with Following Procedure
871A) Excavation of Pit for Foundation Size upto required depth from Ground level
872B) Dressing of Pit and Dry stone pitching 200 mm thick including supply of stones and preparing surface complete.
873C) Providing and laying in position cement concrete of M-10 grade of 75 mm thickness
874D) Reinforcement for R.C.C. work with TMT bars including straightening, cutting, bending, placing in position and binding all complete.
875E) Centring and shuttering including strutting , propping etc. and removal of form work for Footing and Pedestal
876F) Providing & Fixing of 2 no. Required Size PLB HDPE Pipe & Foundation Bolt with template as per OEM Recommendations.
877G) Providing and Laying Reinforce cement Concrete of M-20 grade in Footing and Pedestal including Curing the foundation for minimum 7 days.
878H) Providing and Fixing Nosing Angle 25 mm x 25 mm x 3mm with 2 no. of 100 mm long, 6 mm dia fastener
879Pole Foundation for Octagonal pole from 3 Mtr. To 6 Mtr.
880Pole Foundation for Octagonal pole from 7 Mtr. To 9 Mtr.
881Providing & Fixing of IK07 IP65 protected Top/Bottom mounted LED Post top Luminarie top & bottom made of single piece construction powder coated die cast alluminium housing with UV stabalized Clear / frosted Polycarbonate diffuser and Aluminium anodised with powder quoted reflector. The System level Luminous efficacy ≥ 80 Lumen/W. SMD LEDs is to be used, System CRI>70, CCT: 3000/4000/6500 K. The integral electronic driver must be potted & has a unique BIS R number constant current and Internal/external surge protection device of min. 4KV(L-N) and efficiency > 85%, PF>0.9, THD<10% and input Voltage range of 140-270V AC at 50Hz. System life of 50000 Burning hours with 70% of Initial Lumens maintained . LED Driving output current <750mA as required.
882Minimum lumen output 2800 lm Post top Luminarie
883Minimum lumen output 3200 lm Post top Luminarie
884Minimum lumen output 3600 lm Post top Luminarie
885Providing & Fixing of IK08 IP-66 protected high power LED flood light system with single piece Pressure diecast aluminium housing, toughened glass with suitable lenses on LED / integrated lens diffuser to achieve various beam angles, of high power LED of 3 to 5 watt each . Integrated metal case potted driver as a unique BIS R number (as per IS 15885) having efficiency more than 85 % and in compliance to BIS certified and Trade mark certificate(Fitting & driver both have separate BIS R number). The System level Luminaire efficacy >=130 lm/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC & Low Voltage cutoff @>=90 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10% , LED driving output current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector , Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K ±355K as required.
886High Power LED Flood Light Minimum lumen outpu 3900 lm
887High Power LED Flood Light Minimum lumen output 6500 lm
888High Power LED Flood Light Minimum lumen output 10400 lm
889High Power LED Flood Light Minimum lumen output 13000 lm
890High Power LED Flood Light Minimum lumen output 15600 lm
891High Power LED Flood Light Minimum lumen output 19500 lm
892High Power LED Flood Light Minimum lumen output 23400 lm
893High Power LED Flood Light Minimum lumen output 26000lm
894High Power LED Flood Light Minimum lumen output 32500 lm
895Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED/ integrated lens diffuser & should be High power LED of 3 to 5 watt each . The System efficacy >=125 lm/ wt and integrated metal case potted driver & has a unique BIS R number ( as per IS 15885) with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC & Low Voltage cutoff @>=90 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . LED driving output current <750mA. The luminaire shall be BIS certified (Fitting & driver both have separte BIS R number) and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs as required.
896LED Street Light fixture with Minimum lumen output 2500 lm
897LED Street Light fixture with Minimum lumen output 3750 lm
898LED Street Light fixture with Minimum lumen output 5625 lm
899LED Street Light fixture with Minimum lumen output 7500 lm
900LED Street Light fixture with Minimum lumen output 8750 lm
901LED Street Light fixture with Minimum lumen output 11250 lm
902LED Street Light fixture with Minimum lumen output 12500 lm
903LED Street Light fixture with Minimum lumen output 15000 lm
904Providing & Fixing of IK08 IP65 protected 600-800 mm height LED Bollard Luminarie with base plate made of powder coated die cast aluminium housing with UV stabalized PC diffuser. The System level Luminous efficacy ≥ 80 Lumen/W. SMD LEDs is to be used, System CRI>70, CCT: 3000/4000/6500 K. The integral electronic driver must be potted & has a unique BIS R number constant current and Internal/external surge protection device of min. 4KV(L-N) and efficiency > 85%, PF>0.9, THD<20% and input Voltage range of 90-270V AC at 50Hz. System life of 30000 Burning hours with 70% of Initial Lumens maintained Light output in Cool white or Warm White Colour as per engineers choice. LED driving output current <750mA. as required.
905Minimum lumen output 800 lm Bollard
906Minimum lumen output 980 lm Bollard
907Providing & Fixing of IK08 IP66 / IP67 protected Rectangular shape LED Step Luminarie made of powder coated die cast alluminium housing with UV stabalized PC diffuser. The System level Luminous efficacy ≥ 60 Lumen/W. SMD LEDs is to be used, System CRI>70, CCT: 3000/4000/6500 K. The integral electronic driver must be potted & has a unique BIS R number constant current and Internal/external surge protection device of min. 4KV(L-N) and efficiency > 85%, PF>0.9, THD<20% and input Voltage range of 140-270V AC at 50Hz. System life of 50000 Burning hours with 70% of Initial Lumens maintained . driver current <750mA as required.
908Minimum lumen output 450 lm Step light
909Minimum lumen output 630 lm Step light
910Minimum lumen output 800 lm Step light
911Providing & Fixing of IK08 IP65 / IP66 protected LED Up - Down Luminarie Wall / Surface mounting made of powder coated die cast alluminium housing with with UV stabalized PC diffuser. The System level Luminous efficacy ≥ 80 Lumen/W. COB LEDs is to be used, System CRI>70, CCT: 3000/4000/6500 K. The integral electronic driver must be potted & has a unique BIS R number constant current and Internal/external surge protection device of min. 4KV(L-N) and efficiency > 85%, PF>0.9, THD<10% and input Voltage range of 140-270V AC at 50Hz. System life of 50000 Burning hours with 70% of Initial Lumens maintained Light output in Cool white or Warm White Colour as per engineers choice. LED driving output current <750mA. as required.
912Minimum lumen output 800 lm Up-Down Luminary
913Minimum lumen output 1300 lm Up-Down Luminary
914Minimum lumen output 2150 lm Up-Down Luminary
915Providing & Fixing of Street light bracket made out from following size of ' B ' class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required.
91620 mm Dia.
91725 mm Dia.
91832 mm Dia.
91940 mm Dia.
920Providing & Fixing of IP - 65 protected impact resistant polycarbonate / Polysterene enclosures with knock out for cable entry/out including fixing with nut, bolt, fatner etc as required complete in all respect of following sizes.
921180 x 180 x 91 mm
922250 x 200 x 115 mm
923300 x 450 x 132 mm
924320 x 440 x 179 mm
925320 x 640 x 179 mm
926Supply and erection of PU coated , 6 to 7 mm thick Glass / Fibre Reinforced Pole (GRP /FRP) made by CNC filament winding machine using thermoset resin polyester/epoxy resin system) having minimum 62% glass content. designed to withstand the maximum wind speed as per IS 875, and Tested for deflection not more than 15% length of pole as per ASTM D 4923, The pole should be in one piece and tapered round in shape, pole shafts shall be provided with FRP Anchor with suitable MS cated Base with provision for fixing 4 no. foundation bolts( Including cost of Foundation Bolt), The Pole shall have lockable door of approximate 500 mm length at the elevation of 500 mm from the Base plate with bakelite sheet having 6A SP MCB and 16 sqmm stud type connector ( 4 nos) inside the pole at door opening for cable connection of following length and dimension on Existing cement concrete foundation .
9273 Mtr. Long, Top/ Bottom OD Dia 89/126mm ± 2mm approx. With Base 250X250 X 10mm
928Providing & Fixing of IK10/ IP66 protected pole mount LED Post top Luminarie top & bottom made of single piece construction powder coated pressure die cast alluminium housing with High purity PC diffuser, downward illumination to control light pollution. The System level Luminous efficacy ≥ 120 Lumen/W. SMD LEDs is to be used, System CRI>/=70, CCT: 4000/5700 K. Driver must be potted & has a unique BIS R number constant current and Internal/external surge protection device of min. 4KV(L-N) and efficiency > 85%, PF>0.95, THD<10% and with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety, driver should be Phase to phase protection of 440 V for 4 Hrs. System life of 50000 Burning hours with 70% of Initial Lumens maintained . LED driving current <750mA. Mounting pole diameter 060mm, The Luminaire dimension min Dia 450mm x 200mm(H). including making connections etc. as required.
929Minimum lumen output 5000 lm Post top Luminaire
930Minimum lumen output 6000 lm Post top Luminaire
931Labour charges for installation of submersible motor pump set including lowering/ delowering of pipes, cables, accessories etc. in tube-well/ open well complete including T&P, transportation of tripod, chain pulley block & any other material required for this purpose complete in all respect.
932Lowering only
933Delowering only
934Delowering and Lowering
935SITC of Radial / mixed flow water and anti-corrosive liquid filled submersible motor pump sets suitable for 100/150mm dia borewell. The size of adopter fixed on top of the motor should exceed the top of coupler , for safegaurd the coupler. The job includes labour part of lowering of riser pipe G.I./ H.D.P.E. with rope, cables & pump, installation of complete fitting and accessories, jointing of electrical cables up to Starter. All labour for testing of submersible pumps set and supply of water to water mains, complete in all respect.
936100 mm diameter Submersible pump shall have following HP Rating, phase, Head range, Discharge range respectively.
9371.0 HP, 1-Ø, (10 - 83)Mtr, (40- 10) LPM
9381.5HP, 1-Ø, (11 - 94)Mtr, (40 - 10) LPM
9392.0 HP, 1-Ø, (7- 95)Mtr, (55-22) LPM
9403.0 HP, 1-Ø, (40 -170)Mtr, (60- 20) LPM Copper Wound
9415.0 HP, 1-Ø, (56 - 236)Mtr, (90 - 25) LPM Copper wound
942SITC of Monoblock closed coupled motor pump set with TEFC motor, motor should be IP55-F class and IE2 efficiency for monobloc, with carbon steel /SS-410 shaft, Mechanical seal, Single/Three phase Including cost of hardware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively and Dynamically balanced rotating parts to ensure min. vibration etc. complete in all respect.
9435.0 HP, 3-Ø, (19-44)Mtr, (550-300) LPM ( Bronze impeller & CI Body)
944SITC of Pressure boosting pump with MS Tank, pressure switch, pressure gauge, and all standard fittings fully automatic ON / OFF system, 2900 RPM with stainless steel casing, & impellor suitable for following capacity complete in all respect.
9450.5 HP ( 12 - 26 ) Mtr, (50 - 10 ) with 8 Ltr tank
9460.75 HP -0.90 HP ( 10 - 34 ) Mtr, (72 - 5 ) LPM with 24 Ltr Tank
9471.0 HP ( 10 - 38 ) Mtr, (76 - 8 ) LPM with 24 Ltr Tank
948Providing & Fixing of CI foot valve complete in all respect as required.
94950/ 60 mm
95080/ 100 mm
951Supply & fixing of GI pipes confirming to IS : 1239 P - 1 ( 2004 ) with socket,elbow,tee, flanges duly screwed & welded including rubber washer, nuts & bolts of 8mm dia complete in all respect. ( If Pipe Laid Underground Excavation and refilling cost will be paid extra)
95232mm dia
95340 mm dia.
95450 mm dia.
95565 mm dia.
95680 mm dia.
957100 mm dia.
958SITC of IP 54 OEM Fabricated DOL/Star-Delta Starter panel with switchgear selection as per Type-2 Coordination Chart and made out from 1.6 mm thick powder coated CRCA sheet, enclosure comprising of over load protection relay, short circuit & single phasing protection(for three phase pumps), Illuminated ON / OFF push buttons, ammeter, voltmeter, indicating lamps, 2P/4P MCB etc. suitable for following rating motors complete in all respect.
959For single phase Submersible / Monoblock pump
9600.5 HP to 1.5 HP (DOL starter)
9612.0 HP to 3.0 HP (DOL starter)
9625.0 HP (DOL starter)
963For Three phase Submersible / Mono block pump
964Upto 3.0 HP ( DOL starter )
9653.0 HP to 5.0 HP ( DOL starter )
9667.5 HP to 10.0 HP ( DOL starter )
9673.0 HP to 5.0 HP ( Star / Delta starter )
9687.5 HP to 10.0 HP ( Star / Delta starter )
969SITC of Interconnecting refrigerant copper pipe for split/Ductable/ Casseette AC of DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink Mark Brand Printing on Hard Tubes should be present. Piping between each set of indoor & outdoor units of different sizes as per OEM requirement & specifications including class 'O' Nitrile rubber sleeves (size as per item no. 22.43),7 mil Glass Cloth with 3 coats of anti UV paint (on area which is exposed to weather) chase cutting, supports, making good the same with sand cement plaster etc. as required.
970Charges for oiling, overhauling of ceiling fan, table fan, pedestal fan irrespect to the size of fan including removing,refixing of fan from site and testing etc. as required.
971Fans w/o Removing & Refixing
972Fans with Removing & Refixing at Suitable Location
973Providing and Replacement of ball bearing of ceiling/ exhaust fan and refixing the same at suitable location as requiredand as per OEM recommendations. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material shall be retained by the contractor.
974Replacement of existing transformer oil confirming to IS: 335 after removing of old oil and remove from site (old oil shall be retained by the contractor)
975Charges for Collection , Filtration and dehydration of existing transformer oil with the help of high vaccum filtration machine and cleaning of core-coil assembly by hot oil for removal of sludge / dust particles etc. as required.
976Supplying and charging of fresh refrigerant and testing of performance of air conditioner/ fridge/ water cooler of following capacity including capallary and strainer/ filter.
9771.5 TR Window/ Split A.C.
978S & F of capacitor of 230V/ 275V, 50Hz rating of plastic casing and terminals -Lugs or copper wire.
979Running capacitor
9802.5/3.15 micro farad
981Rewinding of single phase/3phase submersible motor including all necessary material and of the same characteristics as original with required size of super enamelled wire 'E' class insulation material and testing etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
9820.5 H.P. To 1.0 H.P.
9832.0 H.P.
984Above 3.0 HP to 5.0 HP
985From7. 5 HP to 10.0 HP
986Repairing of submersible pump of with replacement of broken impellers ,diffuser,bush/bearing set , oil seal complete with testing etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
9870.5 H.P. To 1.0 H.P.
9882.0 H.P.
989Above 3.0 HP to 5.0 HP
990From7. 5 HP to 10.0 HP
991Repairing of LT/HT bushings of Distribution Transformers including replacement of brass studs , porcelain insulators , nut bolts , oil seals , gaskets etc. complete as required complete in all respect. .
992LT Bushing Set
99363 KVA
994100 KVA
995160 KVA
996200 KVA
997250 KVA
998315 KVA
999400 KVA
1000500 KVA
1001630 KVA
1002800 KVA
10031000 KVA
10041250 KVA
10051600 KVA
1006HT Bushing Set
100763 KVA to 500 KVA
1008630 KVA to 1600 KVA
1009Replacement of Silica gel Breather of Distribution Transformers of following capacities complete in all respect. .
101063 KVA
1011100 KVA
1012160 KVA
1013200 KVA
1014250 KVA
1015315 KVA
1016400 KVA
1017500 KVA
1018630 KVA
1019800 KVA
10201000 KVA
10211250 KVA
10221600 KVA
1023Replacement of gasket of Distribution Transformers of following capacities complete in all respect. .
102463 KVA to 500 KVA
1025630 KVA to 1600 KVA
1026Earth work in excavation/ by mechanical means (Hydraulic Excavator) / Manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sum on plan) including disposal of excavated earth, lead upto 50 m and lift upto 1.5 m, disposed earth to be levelled and neatly dressed:
1027Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with Cement Mortar 1:6 ( 1-Cement : 6-Sand).
1028Rewinding of Heavy duty Exhaust fan motor including all necessary material,The motor is to be wound taking no. of coils,turns and pitch as it was originally wound with required size super enamelled wire with 'E' class insulation material and making connections etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
1029300/ 380 mm sweep
1030450 mm sweep
1031Hire charges for Cable fault locator machine with manpower for detecting fault in underground cable of LT 1.1 KV grade or 11/33KV HT cable
1032for 1st day
1033All in all comprehensive maintenance of 11/0.415 KV or 33/0.415 KV Distribution sub station including 11 KV circuit Breaker , Transformer and its complete accessories , Auto transfer switch ,repairing of LT/HT cables with terminations, LT panel with complete accessories , Sub station Earthings etc with maintaining of Log Books complete in all respect but excluding of transformer oil as and when required.
1034Substation Up to 500 KVA rating Transformer
1035Substation Above 500 KVA Transformer
1036Substation with 33/11 KV Transformer
1037All in all comprehensive maintenance including servicing , replacement of fuel - filter, coolant , lubricating oil etc of Diesel Generating set including auto mains failure (AMF) panel , change over switch , earthing etc as per OEM guidelines and maintenance manual complete in all respet. (Excluding replacement of batteries as and when required.)
1038Up to 62.5 KVA D. G. Set
1039Above 62.5 KVA
1040OEM approved liquid urea for BS-IV type DG Set
1041All in all comprehensive maintenance of Automatic power factor correction panel including repair / replacement of defective componenets to maintain the power factor as per Discom's permissible limit and without any penalty or surcharge.
1042Up to 125 KVAR APFC Panels
1043Above 125 kvar APFC Panels
1044Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level
10451:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
1046Plaster on new surface on wall in cement sand mortar 1:4 including racking of joints etc. complete fine finish :
104720mm thick
104812mm thick
1049Providing and fixing welded mesh/expanded metal mesh 25 mmx 25 mm x 3mm in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. including two coat of red oxide and two coat of enamel paint or more required complete with frame work with 50 X 50 X 6mm angle iron post 30 cm in ground embeded in cement concrete 1:3:6 (30X30X45cm) at corner and every three mtr including painting with one coat of primer and two coat of enamel paint work will be done as per direction of engineer incharge of size complete in all respect. .
1050Gravelling of Transformer / RMU Yard with 100 mm Height Gravels of Size 20 to 25 mm including leveling, Dressing etc. as Required.
1051SITC of 11kV 630 Amps 21KA for 3 Sec. SF6 insulated, outdoor duty (IP54) , Extensible / Non extensible type Ring main unit (RMU) manually operated in combination of VCB modules and Load Break switch consisting of Copper busbar in SF6 insulated stainless steel Outdoor enclosure of thickness of 2 mm and tank of stainless steel Outdoor enclosure of thickness 3mm with manometer. The HV switchgear and control gear should be confirming to IEC-62271-100, IEC-62271-200-2003 & IEC-60694-1996. The RMU should be internal arc tested for 21KA for 1Second with IAC-AFL classification for both Cable chamber and gas tank as per IEC 62271-200 and LBS to be rated for class E3 as per IEC 62271 - 103. Vacum Interrupter should be same as used during type test of RMU. Each feeder of RMU should have voltage presence indicator. and VCB feeder should consist of 1 no. microprocessor based Self powered numerical relay with over Current/ earth fault & short circuit protection with each VCB feeder, 3 Nos. Protection CT shall be of Burden 2.5VA, ratio 50/1A, Class of Accuracy class 5P10 for O/C and E/F protection for each VCB.Load break switch feeder shall have Fault Passage indicator, Right angle boots for all the feeder Modules, Remote trip, Emergency Stop, Cable cover interlocking, Trasnformer protection tapo card etc. All the type test certificates as per IEC and CEA from Third party NABL / CPRI / ERDA accrediated lab to be submitted. (Cost of RCC Foundation / Steel Structure to be paid Extra)
1052Extensible 3 way RMU with 1 no. VCB & 2 No. Load Break Switch
1053Extensible 2 way RMU with 1 no. VCB & 1 No. Load Break Switch
1054Extensible 1 way RMU with 1 No. VCB & Direct Cable Entry.
1055Coupling Assembly to connect two different RMUs.
1056S I T C of star rated Aluminium wound distribution Transformer of following rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11,ONAN Cooled & as per BEE star - 1 ( Correspnding level as per BIS amended upto date of receipt of tender) & BIS approved as per IS 2026- 1977 & losses as defined as per 2014 (Fourth Revision) Level-1 including standard accessories like conservator, silica gel breather, radiator, fins, HT cable box & LT cable boxes, temperature rise in winding/oil 35-40 degree C upto 200 KVA & 40-45 degree C for above 200 KVA, ISI marked drain valve, Dial type Temperature gauge, first filling of transformer oil as per IS :335-1953, Epoxy based paint, undirectional rollers as required including carrying of pre-commission Testing & Charging of Transformer complete in all respect . Factory Tests : The Transformer shall be subjected to routine factory tests (as per IS:2026 and IS:1180) in OEM's own lab and same shall be witnessed by Department engineer. Site Tests : Following tests shall be carried out on each transformer at site by OEM engineer in presence of department's site engineer:- a) Ratio test on each tapping.b) Resistance of windings at principal and all tapings.c) Insulation resistance of the winding between HV to earth / HV to LV / LV to earth.d) Vector group test.e) Magnetic Balance test. Transformer shall be tested from CTL of discom before charging of transformer & complete installaion must be certified from Electrical Inspectorate office as per Indian Electricity rule, (CTL testing charges and Electrical Inspection charges shall be reimbursed by the department to the contractor)
1057Note :Manufacturer's testing laboratory should be certified by NABL and have an in house core cutting facility to ensure proper control & monitoring of quality. This is crutial to prevent the mixing of prime core materials with Second grade or defective materials. The core should be constructed from high grade, non ageing, PRIME GRADE CRGO steel with M4 Grade or Better, using silicon steel laminations, and should be of boltless design. The core and coil assembly should be undergo drying process using a highly efficient vacuum drying autoclave to remove moisture through heating and drying.
1058315 KVA with Off -LTC (+5% to - 10% @ 2.5%) with % impedance 4.5
1059Add: GST@18% EXTRA Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58322303
AUTHORITY Government Departments
TENDER VALUE 50 Lakhs
LAST DATE 12-11-2026
Authority
Authority Name Public Works Department
Work Description Tender for Rate Contract For Various Electrical Work Including Repair And Maintenance Etc. Under The Jurisdiction Of Pwd Electrical Sub Division-V, Jaipur And Other Area, Jaipur.
Basic Detail
Tender No NIT NO 18 of 2026-27 EE PWD E-I Jaipur
Bidding Type Tender
Location
City Jaipur
State Rajasthan
Key Dates
Publish Date 02 Nov 2026
Submission Date 12 Nov 2026
Open Date 13 Nov 2026
Finance
Tender Value 50 Lakhs
Tender Fee 500
EMD 1 Lakhs
Exemption Available
Document List
3Condition.pdf
695d0ce4-5fe1-4fb0-a61a-bc3f2f709e30.html
BOQ_1073273.xls
Cover3.pdf
Tendernotice_1.pdf
Tendernotice_2.pdf
Tendernotice_3.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 02, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 12, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Nov 13, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
pdf

3Condition.pdf

html

695d0ce4-5fe1-4fb0-a61a-bc3f2f709e30.html

xls

BOQ_1073273.xls

pdf

Cover3.pdf

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

pdf

Tendernotice_3.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender