Tender For special Repair To Block No. P-85 & P-92 Of Me Line Of Cod Agra Under Ge (West) Agra
Tender Value
98.04 Lakhs
Estimated cost
Bid Submission
30 Nov 2026
8 days left
EMD
1.72 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Agra → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for special Repair To Block No. P-85 & P-92 Of Me Line Of Cod Agra Under Ge (West) Agra
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling brick tiles from roof surfaces, laid bedded and pointed in mortar of any description, including removal of the tiles and debris from the site, complete all as specified and directed. |
| 2 | Demolition and removal of mud from roofs, of any thickness, including removal of plastering and leaping (whether the full thickness or only a portion thereof), complete all as specified and directed. |
| 3 | Disposal of removed/demolished soil, debris and other materials to a distance exceeding 1.50 km but not exceeding 5.00 km from the site and depositing at the location directed, complete all as specified and directed. |
| 4 | M&L for cement concrete 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges and in similar works including use of necessary form work (striaght or curved) complete all as specified and directed. |
| 5 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 6 | M&L for cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in benching, coping, roof padding and similar work including use of necessary form work (striaght or curved) complete all as specified and directed. |
| 7 | Taking down existing treatment of sunken portions, including demolition and removal of old concrete/treatment, cleaning and preparing the surface, and carrying out new sunken portion treatment in accordance with the steps specified hereunder :-(a) S&F GI drainage spout, 40 mm bore, light grade, projecting through the external/outer wall and extending approximately 450–600 mm beyond the outer face of the wall.(b) M&L for providing and laying PCC 1:1.5:3, Type A-0, using 12.5 mm graded stone aggregate, 50 mm thick, laid to slope towards the drainage spout pipe, mixed with approved waterproofing chemical of make Fosroc/Sika/Pidilite/STP, as per the manufacturer's instructions, including forming khurras of minimum 150 mm × 150 mm at appropriate locations to ensure free flow of any leaked water towards the drainage spouts. The drainage spouts shall be securely fixed and embedded integrally in the PCC using the same concrete,(c) M&L for 18 mm thick cement plaster in cement mortar 1:3) on vertical faces, mixed with approved waterproofing chemical, Make: Pidicrete URP of Dr. Fixit or equivalent product of Sika/Pidilite/Fosroc/STP, as per the manufacturer's instructions, including surface preparation, finishing and curing.(d) Item No. 7(c) shall be executed while the concrete is still green, as specified in Item No. 7(c) above. Proper curing and ponding test shall be carried out before laying the drainage/water supply pipes, to the entire satisfaction of the Engineer-in-Charge.(e) Applying two coats of SikaTop Seal-107 of Sika or other equivalent waterproofing coating of Fosroc/Pidilite/Dr. Fixit/STP on prepared vertical as well as horizontal surfaces, including surface preparation, in accordance with the manufacturer's instructions.(f) Drainage and water-supply pipes, including sanitary pipes, where required, shall be laid to the required gradient and tested for leakage before being concealed/covered. A clear gap shall be maintained beneath the pipes by providing suitable cement concrete supports/blocks Description of item contd.. Please Enable Macros to View BoQ information |
| 8 | Taking down existing treatment of sunken portions, including demolition and removal of old concrete/treatment, cleaning and preparing the surface, and carrying out new sunken portion treatment in accordance with the steps specified hereunder :-(a) S&F GI drainage spout, 40 mm bore, light grade, projecting through the external/outer wall and extending approximately 450–600 mm beyond the outer face of the wall.(b) M&L for providing and laying PCC 1:1.5:3, Type A-0, using 12.5 mm graded stone aggregate, 50 mm thick, laid to slope towards the drainage spout pipe, mixed with approved waterproofing chemical of make Fosroc/Sika/Pidilite/STP, as per the manufacturer's instructions, including forming khurras of minimum 150 mm × 150 mm at appropriate locations to ensure free flow of any leaked water towards the drainage spouts. The drainage spouts shall be securely fixed and embedded integrally in the PCC using the same concrete,(c) M&L for 18 mm thick cement plaster in cement mortar 1:3) on vertical faces, mixed with approved waterproofing chemical, Make: Pidicrete URP of Dr. Fixit or equivalent product of Sika/Pidilite/Fosroc/STP, as per the manufacturer's instructions, including surface preparation, finishing and curing.(d) Item No. 7(c) shall be executed while the concrete is still green, as specified in Item No. 7(c) above. Proper curing and ponding test shall be carried out before laying the drainage/water supply pipes, to the entire satisfaction of the Engineer-in-Charge.(e) Applying two coats of SikaTop Seal-107 of Sika or other equivalent waterproofing coating of Fosroc/Pidilite/Dr. Fixit/STP on prepared vertical as well as horizontal surfaces, including surface preparation, in accordance with the manufacturer's instructions.(f) Drainage and water-supply pipes, including sanitary pipes, where required, shall be laid to the required gradient and tested for leakage before being concealed/covered. A clear gap shall be maintained beneath the pipes by providing suitable cement concrete supports/blocks Description of item contd.. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 02, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 30, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysDec 07, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 15 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender