Defence Statutory Bodies & Commissions/Committees Closing in 6 days TDR #58320733

Tender For Special Repair To A Wing P-49 Building At Naval Base, Kochi Under Ge(Nw) Kochi

Issued by Statutory Bodies & Commissions/Committees · Ernakulam, Kerala
Tender Value
42.90 Lakhs
Estimated cost
Bid Submission
23 Nov 2026
6 days left
EMD
85800
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ernakulam → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Special Repair To A Wing P-49 Building At Naval Base, Kochi Under Ge(Nw) Kochi

BOQ

Name of Work:- SPECIAL REPAIR TO A WING P-49 BUILDING AT NAVAL BASE, KOCHI UNDER GE(NW) KOCHI
Sl. No. Item Description
1Dismantling single layer mangalore pattern or similar tiles in roofing complete all as specified and as directed.
2Dismantling plain or corrugated steel sheeting any gauge, thickness complete in roofing complete all as specified and as directed.
3Dismantling battens for tiles, shingles, etc of any size exceeding 15cm spacing including tilting fillets complete all as specified and as directed.
4Dismantling timber boarding any description fixed in any position with nails complete all as specified and as directed.
5Dismantling timber scantiling 40 Sqcm and over in section unframed work in any position complete all as specified and as directed.
6Dismantling timber scantlings under 40 Sqcm in section for unframed work in fillets, rails, posts, rafters, purlins etc, in unframed works complete all as specified and as directed.
7M&L for lInd class hard wood plain fillets square, rectangular or triangular in section clean sawn secured with nails etc of sectional area exc 3 Sqcm and n.exc 6 Sqcm complete all as specified and as directed.
8M&L for 2nd class hard wood in scantling clean sawn fixed as in purlins, rafters, etc in roof complete all as specified and as directed.
9M&L for IInd class hard wood boarding clean sawn with butt joints, 20mm thick as in soffits of gutter, eves board fixed with nails, etc complete all as specified and as directed.
10M&L for 2nd class hard wood clean sawn battern for tile at 30cm centres of sectional area exc 15Sqcm and n.exc 25Sqcm complete all as specified and as directed.
11S&F 0.63 mm thick galvanised corrugated mild steel sheeting with two corrugation side lap, fixed with L-hook or cranked bolts complete all as specified and as directed.
12S&F plain aluminium sheeting 0.71mm thick, Alloy 31000H4 in ridge, hips, valley gutter, drip and straight flashings complete all as specified and as directed.
13M&L for preparing and treating tiles battens any size and spacing with one coat of creosote complete all as specified and as directed. (Measured overall in one side only spacers not deducted)
14M&L for mangalore pattern roof tiles, interlocking at side joints, laid dry complete all as specified and as directed.
15M&L for ridge or hip tiles to suit mangalore pattern of roofing tiles, bedded and jointed in cement mortar 1:6 complete all as specified and as directed.
16M&L for 6mm thick asbestoes cement plain building boards, fixed to timber framework with screws complete all as specified and as directed.
17Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
18S&F rolled sections Fe-290 (Gde E- 165) as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and as directed.
19M&L for preparation of new steel surfaces of any description, over 10cm in width or girth,not otherwise described and applying two coats of anti corrosive Epoxy paint over a coat of epoxy primer, on steel surfaces complete all as specified and as directed.
20S&F in repair 200mm dia half round or 220mm width rectangular UPVC heavy duty eaves gutter of pressure rating 6 kg/cm2 of approved make including necessary fitting like bend WC/MS clips etc complete all as specified and as directed.
21S&F in repair 110mm dia PVC (SWR) pipe single socketed in any length with rubber ring joints, laid in trenches/floor or fixed to wall including necessary clamps complete all as specified and directed.
22S&F PVC (SWR) bend any radius 110mm bore complete all as specified and directed.
23M&L for preparation of old painted surfaces of wood and wood based materials of any description including filling of holes by filler (fevicol and wooden dust) and applying one or more coats of french polish over a coat of wood filler complete all as specified and directed.
24Dismaintling wall/floor tiling/ terrazo tile/ mosaic tiles/ PCC tiles including cement mortar bedding removing serviceable tilels to store and rubbish off the premises complete all as specified and directed.
25M&L for light shade vitrified ceramic tiles 8-10mm thick (square/rectangular) area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in cement mortar 1:4 laying floor finishes, complete all as specified and directed.
26M&L for vitrified ceramic tiles 8-10mm thick (square/rectangular) area of each tiles exc exc 0.36 Sqm but not exc 0.42 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 5mm thick screed bed of cement mortar 1:3 as in skirtings floor finishes, complete all as specified and directed.
27M&L for complete removal of existing treatment and preparation of surfaces and applying two coats of oil bound distemper over a coat of 1.5 mm thick wall care putty and one coat of alkali resistant primer complete all as specified and directed.Note:- Application of paint, primer and wall care putty shall be as per manufacturer's instruction and as directed by Engineer-in-Charge. Please Enable Macros to View BoQ information
28M&L for complete removal of existing treatment and preparation of surfaces and applying two coats of oil bound distemper over a coat of 1.5 mm thick wall care putty and one coat of alkali resistant primer complete all as specified and directed.Note:- Application of paint, primer and wall care putty shall be as per manufacturer's instruction and as directed by Engineer-in-Charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58320733
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 42.90 Lakhs
LAST DATE 23-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Special Repair To A Wing P-49 Building At Naval Base, Kochi Under Ge(Nw) Kochi
Basic Detail
Tender No 8676_GE_NW
Bidding Type Tender
Location
City Ernakulam
State Kerala
Key Dates
Publish Date 31 Oct 2026
Submission Date 23 Nov 2026
Open Date 01 Dec 2026
Finance
Tender Value 42.90 Lakhs
Tender Fee 500
EMD 85800
Exemption Not Available
Document List
BOQ_893615.xls
eb998209-e8f6-40e9-8315-589ab3e60d02.html
PS8676.pdf
Tender8676.pdf
Tendernotice_1.pdf
Testing.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 31, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 23, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Dec 01, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 14 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_893615.xls

html

eb998209-e8f6-40e9-8315-589ab3e60d02.html

pdf

PS8676.pdf

pdf

Tender8676.pdf

pdf

Tendernotice_1.pdf

pdf

Testing.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender