Tender For Provn Of Solid Waste Management Plant At Kalka Mil Stn Under Ge (I) Jutogh
Tender Value
63.02 Lakhs
Estimated cost
Bid Submission
28 Nov 2026
2 days left
EMD
1.69 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Panchkula → Haryana
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provn Of Solid Waste Management Plant At Kalka Mil Stn Under Ge (I) Jutogh
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 12-Nov-2026 | Changes in PS | Other | 28-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in any type of soil complete all as specified and directed. |
| 2 | Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out in any type of soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all as specified and directed. |
| 3 | Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m depth for foundation, laying of cable, pipes and getting out in any type of soil including dressing/trimming of sides and leveling, grading and ramming of bottom of excavation complete all as specified and directed. |
| 4 | M&L for Plain cement concrete 1:4:8, type D-2, using 40mm graded crushed stone aggregate as in foundation filling and mass concrete complete all as specified and directed. |
| 5 | M&L for old size brick work with sub class 'B' briick straight or curved on plan exc 6m mean radius built in Cement Mortar 1:6 complete all as specified and directed |
| 6 | M&L for old size brick work with sub class 'B' briick straight or curved on plan to any radius in half brick thick built in Cement mortar 1:4 complete all as specified and directed. |
| 7 | M&L for old size brick work with sub class 'B' briick in one brick thick honey comb walling, built in Cement mortar 1:4 complete all as specified and directed. |
| 8 | S&F Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips , complete all as specified and directed. |
| 9 | S&F Mild steel TMT bars 5mm and over upto and including 10mm dia in stirrups spaces and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips , complete all as specified and directed. |
| 10 | M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc., complete all as specified and directed. |
| 11 | M&L for Reinforced cement conctrete 1:2:4, Type B-1, using 20mm graded crushed stone aggregate as in beams, cantilevers, bressumers, lintels over 1.5m span etc., complete all as specified and directed. |
| 12 | M&L for 40mm thick Damp proof course in plain cement concrete 1:2:4, type B-0, using 12.5mm graded crushed stone aggregate to horizontal or vertical surfaces including necessary formwork complete all as specified and directed. |
| 13 | M&L for rendering 15mm thick wall plaster in cement mortar 1:4 on fair faces of brick work or concrete surfaces including finished even & smooth without using extra cement with WPC, complete all as specified and directed.Note : WPC shall be measured and paid separately. |
| 14 | M&L for rendering 15mm thick wall plaster in cement mortar 1:6 on other than fair faces of brick work or concrete surfaces including finished even & smooth without using extra cement all as specified and directed. |
| 15 | Supply only Water proofing compound complete all as specified and directed. |
| 16 | M&L for preparation of newly plastered wall surfaces and applying two coats of Acrylic smooth exterior weather coat paint of required shade, new work applied @1.67ltr/10 sqm over and including priming coat of primer with alkali resistant priming paint applied @ 2.2kg/10Sqm) complete all as specified and directed. |
| 17 | M&L for preparing new plastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed. |
| 18 | S&F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979, grade St-240, complete all as specified and directed |
| 19 | S&F mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc complete drilled for fixing of steel sheeting or other covering. Doors, etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings ( inclusive of steel, sheeting or other covering, running rails and guides) and hanging also fastening and fixing complete Fe-290 (Gde E-165), complete all as specified and directed. |
| 20 | S&F Green PVC coated Hexagonal hard drawn steel wire fabric cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9 mm in dia in reinforcement exc 4 Kg/sqm complete all as specified and directed. |
| 21 | S&F mild steel plates (plain) channels, square cut or notched (ordinery and counter sunk) forming holes, without any attachment complete all as specified and directed. |
| 22 | S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm but n.exc 10cm long, complete all as specified and directed. |
| 23 | S&F pre-coated galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 mpa as in roof covering / cladding to wall, fixed with cranked hook bolt with washer self tapping screws, complete all as specified and directed. |
| 24 | S&F pre-coated galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 mpa as in roof covering / cladding to wall, fixed with cranked huck bolt with washer self tapping screws as in ridge eves, gutter etc., complete all as specified and directed. |
| 25 | S&F 0.63mm thick mild steel, plain, black sheet in wall cladding, steel gates and similar works, cut to size holes punched including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40mm lap joints with riveted or welded seams, incl bending or turning up, mitred angles, etc. as required, complete all as specified and directed. |
| 26 | M&L for preparation of new steel surfaces and applying two coats of synthetic enamel paint on steel & iron surfaces of any description, not otherwise, described, over 10cm width or girth over one coat of red oxide, zinc chrome complete all as specified and directed. |
| 27 | S&F for Anodised aluminium snap grid frame work for false ceiling with 6 mm dia GI suspender upto 1200 mm length adjusting level fixed to roof slab by means of ceiling clip made out of GI flat 40x3 mm size, 60mm long and expansion hold fasteners 12.5 mm dia 40 mm long, complete all as specified and directed. |
| 28 | M&L for 4mm thick non asbestos fibre cement building boards white/ off white (E board designer) fixed or laid /inserted to timber/ GI/ Aluminium frame work with screws in ceiling flat or sloping complete all as specified and directed. |
| 29 | S&F 75mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints laid in trenches or in floor, complete all as specified and directed. |
| 30 | S&F 75mm bore PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed. |
| 31 | Cutting into existing manholes for connecting new drains, making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4, type B-1, smooth finished and forming benching as required , complete all as specified and directed. |
| 32 | M&L for plain cement concrete 1:3:6, type C-2, using 40mm graded crushed stone aggregate as in surface channel/ drains incl fair finishes & necessary formwork, complete all as specified and directed. |
| 33 | M&L for hardcore of broken stone or boulders gauge n. exc 63 mm deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/ rammed to a true surfac, complete all as specified and directed. |
| 34 | M&L for 75mm thick plain cement concrete 1:4:8, type D-2, using 40mm graded crushed stoneb aggregate as in sub base, complete all as specified and directed. |
| 35 | M&L for 25mm thick plain cement concrete 1:2:4, type B-1, using 20mm graded crushed stone aggregate as in under layer for laying floor finish complete all as specified and directed. |
| 36 | M&L for coloured non skid ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tiles exceeding 0.11 sqm but n. exc 0.18 sqm in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in cement mortar 1:6, complete all as specified and directed. |
| 37 | M&L for non skid ceramic coloured tile of approved shade and pattern 7mm to 8mm thick area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm in skirting/dado and riser to steps etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 10mm thick backing coat plaster with cement mortar (1:4), complete all as specified and directed. |
| 38 | M&L for PCC 1:2:4, type B-1, using 20mm graded crushed stone aggregate as in coping and the like including weathering, slightly rounded or chamferred angles and throating, use of formwork straight or curved complete all as specified and directed. |
| 39 | M&L for 100mm thick plain cement concrete 1:4:8, type D-2, using 40mm graded stone aggregate as in sub base finished the surface even and smooth without using extra cement, complete all as specified and directed. |
| 40 | M&L for providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand, complete all as specified and directed. |
| 41 | M&L for chequered cement concrete tiles pre-polished 30cmx30cmx25mm thick, set, jointed and pointed in neat cement slurry with grey cement and pigment in floors incl 15mm thick screed bed or bedding layer in Cement mortar 1:6, complete all as specified and directed. |
| 42 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed. |
| 43 | M&L for Plain cement concrete 1:3:6, type C-2, using 40mm graded crushed stone aggregate, 75mm thick as in plinth protection with necessary formwork complete all as specified and directed. |
| 44 | M&L for precast cement concrete 1:2:4, type B-1, using 20mm graded crushed stone aggregate as in landings, cover slab (for manholes etc.), chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces including chamfers, weatherings, throating etc. and setting in cement mortar 1:4 complete with joints to match, complete all as specified and directed.Note :- Reinforcement and handles shall be measured and paid seperately. |
| 45 | Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25cm thick in each layers complete all as specified and directed. |
| 46 | Removing excavated material n exc 50m and depositng where directed at a level n.exc 1.5m above the starting point (ncl filling in floor) for any type of soil complete all as specified and directed. |
| 47 | S&F Factory made single extruded WPC (Wood Polymer Composite) Solid door/ window/ Ceosetory window & other Frames/ Chowkhat of size 45x85mm comprising of virgin PVC polymer of K value 58-60(Suspension Grade) calcium carbonate and nature fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screwed having minimum frame density of 750kg/cum, screw withdrawal strength of 2200 N(Face) & 1100 N/mmSq, modules of elasticity 900N/mmsq and resistance to spread of flame of class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete all as specified and directed. Note: 1.For WPC Solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 48 | S&F factory made single extruded WPC (wood polymer Composite) solid decorative type flush door shutter of 30mm size comprising of virgin polymer of k value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650kgcum and screw withdrawal strength of 1800N (Face) & 900 N (Edge) Minimum compressive strength 50N/Sqmm and resistance to spread of flame of class A category with property of being termite /borer proof, water/moisture proof and fire retardant and fixing with stainless steel but hinges of required size with necessary full body threaded star headed counter sunk SS screws, complete all as specified and directed. Note: Stainless steel but hinges shall be paid separately. |
| 49 | S&F Butt hinges, 100 mm long stainless steel with galvanized mild steel hinge pin, anodized and fixed, 1.6 to 2mm thick complete all as specified and directed. |
| 50 | S&F 150mm extruded aluminium alloy handles frabricated type, anodized complete all as specified and directed. |
| 51 | S&F 200mm aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and directed. |
| 52 | S&F 300mm aluminium alloy anodised sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed. |
| 53 | S&F steel windows of profile rectangular tube section with side hung shutters incl projecting type hinges with steel handles, MS peg stay with glazing bars, complete all as specified and directed. |
| 54 | S&F steel windows of profile rectangular tube section with side hung shutters including projecting type hinges with steel handles, MS peg stay without glazing bars, complete all as specified and directed. |
| 55 | S&F stainless steel wire cloth 0.36mm nominal dia or wire and average width or aperture 1.40mm and fixed with stainless steel wire staple in complete all as specified and directed. |
| 56 | S&F 3mm thick figured glass, pin headed type and fixed with wooden beads in squares not exceeding 0.5 Sqm in each pane complete all as specified and directed. |
| 57 | S&F mild steel Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes, framed guard bars, barred iron doors; ladders, framed balusters, walk ways; railings, framework of water tanks and similar work conforming to Fe 290-0 or Gde E-165, complete all as specified and directed. |
| 58 | M&L for 20mm thick granite (of any type) tiles machine cut, in counter top laid over cement screed and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete & including 15mm thick (average thickness) cement mortar 1:6 screed, complete all as specified and directed. |
| 59 | S&F granite tiles (of any type) 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete in cupboard shelfs, steps, jambs, pillars, window cills, cookings platforms including 10mm thick backing coat plater with CM 1:4, complete all as specified and directed. |
| 60 | M&L for point wiring with 1.5 Sqmm (nominal area), PVC insulated, FRLS multistranded, single core unsheathed, copper conductor cable drawn through and including new PVC rigid conduit medium grade not less than 20 mm dia with all accessories concealled in wall / fitted with rafter & column etc. etc. with and including 1.5 Sqmm (nominal area) PVC insulated, unsheathed,multi stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth dolly including sunken boxes of suitable size with 3 mm thick hylam sheet top cover fixed with suitable size of brass screws for mounting switches, sockets, regulators etc complete for one light/ fan /bell point controlled by one, single pole one way switch, complete all as specified and directed. |
| 61 | S&F Switch piano flush type 6 amps, single pole one way, white in colour, duly ISI marked complete all as specified and directed. |
| 62 | S&F Ceiling rose surface type, 240 volts, 50 Hz, 6A, Pilot 3 plate, white in colour, bakelite 65 x 50mm, 3 terminals duly ISI marked complete all as specified and directed. |
| 63 | S&F LED light fitting 1x20 Watt, 6500K, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed |
| 64 | S&F LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, complete all as specified and directed. |
| 65 | M&L for submain wiring with 1100 volt grade two single core FRLS Wire PVC insulated and unsheathed cable with stranded copper conductor 2.5 sqmm drawn into and including electrical grade PVC conduit not less than 25 mm dia with IS 9537 (Part-III) 1983 mark, or relevant ISI mark with all accessories fixed concealed including chase cutting in brick/ stone masonry for fixing conduit and making good the disturb surfaces of wall as per existing including 2.5 sqmm multi - stranded copper conductor as earth wire in green colour complete all as specified and directed.Note: Two Runs of 2.5 Sqmm single core and one run of 2.5 sqmm single core cable shall be measured as one unit. |
| 66 | S&F factory made sheet metal enclosures double door type made out of CRCA 1.2 mm thick M.S sheet, powder coated, SPN DB with 200 Amps rated bus bar, 8 way, IP-42 protection surface mounting, 240 volts, dust and vermin proof, suitable for incorporation of MCBs duly cocealled in wall/ fixed to columns, factory made, including making good distrubbed surfaces with matching colour, complete all as specified and directed. |
| 67 | S&F factory made sheet metal enclosures double door type made out of CRCA 1.2 mm thick M.S sheet,powder coated, SPN DB with 200 Amps rated bus bar, 4 way, IP-42 protection surface mounting, 240 volts, dust and vermin proof, suitable for incorporation of MCBs duly cocealled in wall/fixed to columns, factory made, including making good distrubbed surfaces with matching colour, complete all as specified and directed. |
| 68 | S&F MCB SPN, 32 Amps, 240 volts, \\"B\\" series, 10KA duly ISI marked, complete all as specifiedand directed. |
| 69 | S&F MCB SP, 6-32 Amps, 240 volts, \\"B\\" series, 10KA duly ISI marked, complete all as specifiedand directed. |
| 70 | Supply, installation, testing & commissioning of Wall mounted/ Standalone Incinerator having capacity 80 pads per cycle/ 1200 pads per day made up of stainless steel SS 304 1 mm with external dimensions 750x480x390 mm operated on Voltage 220V, Wattage 2600W peak. Incorporated with Quick Burn Induction Heater of 2000W, Flue gas pipe of 1 mtr SS pipe with 3 inch dia, Safety MCB i.e. 25 Amp RCCB + 16 Amp MCB, Ash collection tray shall be easily openable and disposable, complete all as specifiedand directed. |
| 71 | Supply, installation, testing & commissioning of Organic waste converter OWC Gaia 800 litre composter (Aerobic composting type), Compost output time approx 20 days, Capacity 800 litres, Material UV Stabilized, roto moulded plastic, Compost output Qty 120-140 Kg from each Gaia, complete all as specified and directed. |
| 72 | Supply, installation, testing & commissioning of Falcon Bio Shredder cum chipper Fbs 520 (Electric oprated) having power consumption 5HP, weight 90 kg, production cap 3-4 Cum/Hr, branch diameter 70mm, steel body, complete all as specified and directed. |
| 73 | S&F 3 Phase 5 HP DOL Starter in sheet metal enclosure suitable for 5 HP shredder motor with relay range 8.9 A - 13.5 A in sheet metal enclouser with contactor, Volt/AmmeterCT's , short circuit protection, single phase preventer, FRLS (Fire retardant low smoke) Internal wiring, IP54 degree of protection, class H insuation, complete all as specifiedand directed. |
| 74 | M&L for cocopeat used in Gaia composter to absorb excess moisture released during waste decomposition process and support the growth of benefitial microbes and improves aeration within the compost, resulting in well nitrated and nutrient rich compost, complete all as specified and directed. |
| 75 | M&L for Microbes for decomposition of organic waste efficiently and naturally and conversion of biodegradable waste into nutrient rich compost, complete all as specified and directed. |
| 76 | M&L for Leaf composting accelerator to accelerate the natural breakdown of dry leaves, enhance microbial activity, improves aeration for generation of rich organic leaf compost that can be used as a natural fertilizer and soil conditioner, complete all as specified and directed. |
| 77 | S&F fully retro reflective sign board 1.5x1.2 Mtr board made out of 3 mm thick ACP (aluminum composite panel) sheet framed with 40 mm dia and wall thickness 3.0 mm stainless steel pipe having all sides and entire surface fully bonded with retro reflective sheeting of HIP (High Intesity Prismatc) grade having pressure sensitive adhesive. Borders and messages as indicated cut out. Background in blue and matter in white colour tape having two posts of 50mm dia wall thickness 3.0 mm stainless, steel pipe 4.50 mtr long any shape, size, design as a vertical supports and embedded in ground with PCC 1:2:4, type B-1, using 20mm graded crushed stone aggregate of size 450x450x600mm incl necessary excavation and earth work, complete all as specified and as directed. Note: One side with slogan and other side with indication by Engr-in-Charge. |
| 78 | Supply, laying, jointing and testing of cable XLPE insulated, screened, PVC bedded ,galvanized steel strip or wire armoured heavy duty electric cable with multistranded aluminium conductor, 1100 volts grade of size 16 Sqmm 4 core confirming to IS : 7098 (Part - I) laid in trenches, under road or passing through pipes/ducts or fixed to walls/poles complete with proper thimbles all as specified and directed. Loc :- From Existing LT panel to new LT panel (SWM Plant). |
| 79 | All as per Srl item No 78.00 above but size 10 sqmm 4 core, complete all as specified and directed. Loc :- From Existing LT panels to Shredder Machine Starters |
| 80 | All as per Srl item No 78.00 above but size 10 sqmm 2 core, complete all as specified and directed. Loc :- From Existing LT panels to new Sheds at two diff locations |
| 81 | S&F flat three core PVC Insulated & PVC Sheathed Industrial Cable of Voltage Grade 1100 Volt, Conforming to IS 694 of size 6 Sqmm complete all as specified and directed.Loc :- New LT Panel to Incinerator |
| 82 | Supply, installation, testing and commissioning factory made, LT bus bar panel board cubical, Outdoor type, floor/ground mounted double door, 3 phase 4 wire, 50 cycles, 415 Volts.The panel board shall be made of 3.15 thick CRCA sheet (Min size 0.6 m x 0.5 m x 0.35 m ), the panel shall be painting with powder coated finish with RAL 7032 SIEMENS GRAY Structure after seven tank phosphate treatment front & back opening type and fixing 2 Nos danger notice plate with letter figures and conventional skull bones in signal red colour and fixed front & back door to LT Panel with voltage and danger indicated in Hindi and English with double door shutter and shall have louvers and air vent gasket for natural flow of air Neoprene adhesive type gasket shall be used to make panel vermin proof. The panel have to provide proper compartment as per IS specification and wiring of panel with suitable size of copper conductor FRLS cable not less than 2.5 sqmm,gaskets thimbles including cable entry glands ,all as directed. Base frame of the panel shall be made of angel iron of size 50x50x5mm of upto 1/2 mtr hight from GL& 1/2 mtr for below GL in PCC (1:3:6) type C-2 using 40 mm stone aggregates comparising of following:- |
| 83 | (i) Panel having common aluminium bus bar of capacity 200 Amp TPN each and suitable capacity size TPN bus bar for outgoing MCCB's, including aluminium lugs to connect the cable and cable gland for each cable entry as per cable size (ii) Incomming :- Adjustable Thermal Magnetic release MCCB 100 Amp 16 KA rating TPN 415 volts - 01 No (Incomer) (iii) Outgoing :- (a) Adjustable Thermal Magnetic release MCCB 63 Amp 16 KA rating TPN 415 volts - 01 No (out going) (b) MCB TPN 40 amps -01 Nos (outgoing)(iv) Volt Meter 0-500 Volts digital type Square shape Flush mounted with selector switch -1 No (v) Ammeter 0 - 200 Amps digital type square shape 96mm flush mounted with selector switch and CT's 200/5 A - 1 No.(vi) Indicator lamp RYB : 01 Set with suitable CT coil complete.Note : The LT Panels and Bus bar shall be manufactured by OEM only. Please Enable Macros to View BoQ information |
| 84 | (i) Panel having common aluminium bus bar of capacity 200 Amp TPN each and suitable capacity size TPN bus bar for outgoing MCCB's, including aluminium lugs to connect the cable and cable gland for each cable entry as per cable size (ii) Incomming :- Adjustable Thermal Magnetic release MCCB 100 Amp 16 KA rating TPN 415 volts - 01 No (Incomer) (iii) Outgoing :- (a) Adjustable Thermal Magnetic release MCCB 63 Amp 16 KA rating TPN 415 volts - 01 No (out going) (b) MCB TPN 40 amps -01 Nos (outgoing)(iv) Volt Meter 0-500 Volts digital type Square shape Flush mounted with selector switch -1 No (v) Ammeter 0 - 200 Amps digital type square shape 96mm flush mounted with selector switch and CT's 200/5 A - 1 No.(vi) Indicator lamp RYB : 01 Set with suitable CT coil complete.Note : The LT Panels and Bus bar shall be manufactured by OEM only. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Nov 12, 2026
11:30 IST
Tender Published
Tender notice published.
Completed
Nov 28, 2026
18:00 IST
Corrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 2 daysNov 28, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender