Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #58320649

Tender For External Periodical Services Incl Connected B/R Services, Repairs To Chajja And External Plastering Works Etc In The Area Of Age B/R-Ii Under Ge (East) Delhi Cantt-10

Issued by Statutory Bodies & Commissions/Committees · New Delhi, Delhi
Tender Value
48 Lakhs
Estimated cost
Bid Submission
21 Nov 2026
0 days left
EMD
96000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for External Periodical Services Incl Connected B/R Services, Repairs To Chajja And External Plastering Works Etc In The Area Of Age B/R-Ii Under Ge (East) Delhi Cantt-10

BOQ

Name of Work:- EXTERNAL PERIODICAL SERVICES INCL CONNECTED B/R SERVICES, REPAIRS TO CHAJJA AND EXTERNAL PLASTERING WORKS ETC IN THE AREA OF AGE B/R-II UNDER GE (EAST) DELHI CANTT-10
Sl. No. Item Description
1M&L for preparation of New/old decoreated external wall/Ceiling surface of existing treatment by scrapping with TruCare Wall Sander : L-01/H-01 (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7”/9” to make the surface free from dust, loose paint etc. or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible and applying two coats of weather proofing exterior acrylic emulsion paint over suitable priming coat premium quality over wall/ceiling, complete all as specified and as directed by Engr-in-Charge. Note: The work shall be exicuted in G+ 8th floor Height. (Make : BERGER (WEATHER COAT ALL GUARD), ASIAN (APEX ULTIMA), NEROLAC (EXCEL TOTAL) BIRLA (OPUS PRIME E70))
2M&L for applying of 1 mm thick wall care putty over prepared surfaces of new/old walls/ceiling including sanding of putty surface properly with regmar to make the surface free from dust or loose particles, complete all as specified and as directed by Engr-in-Charge. Note: The work shall be exicuted in G+ 8th floor Height.
3M&L for preparation of old decoreated external wall surface by mechanised sander of Berger paints or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible, and applying two coats of cement base paint over coat of primer on walls complete all as specified and as directed by Engr- in-charge.
4Demolition of brick work built in cement mortar including all quoins, arches, pillars etc complete all as specified and as directed.
5M&L for brick work with sub class 'B' straight or curved on plan exc 6m mean radius and built in CM 1:4 complete all as specified and directed.
6Taking down grit / cement plaster on brick walls etc including raking out joints hacking for key scrubbing down with water etc all as directed.
7M&L for rendering 15 mm thick in cement mortor 1:4 on brick/ concrete surfaces and finishing the surface even and fair without using extra cement complete all as specified directed.
8M&L for prepration of newly plastered surfaces of wall and applying two coats of cement base paint over a coat of Primer complete all as specified and directed .
9M&L for washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement 4 coarse sand) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement 1/2 coarse sand and 2 stone chipping 10mm nominal size) in pannels wih grooves all aroud as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chipping complete all as specified and directed.
10M&L 10-12mm thick polymer modified readymix cement base plaster as per manufacturer instruction on fair / unfair faces of brick work or concrete surfaces & finishing the surface even & smooth as per manufacturer instruction complete all as specified & directed.
11M&L for prepration of new/Old plastered surfaces of wall and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new/ Old surfaces. complete all as specified and directed.
12Chipping off existing loose, damaged Concrete from RCC members of all affected RCC Columns, Beams, Slabs and Chajjas on External and internal facades, etc beyond main reinforcement. (if required in the opinion of the Consultant), carefully with chisel and hammer Providing and applying ‘Rusticide SS’ Rust passivator or equivalent as specified in the Brand Names to existing reinforcement. bars Including wire brushing of reinforcement, cleaning washing of concrete etc complete as directed. Providing and applying two coats of rust preventor slurry made out of “Polyalk Fixoprime” or equivalent as specified in the Brand Names and cement in proportion 1:1.5 to existing reinforcement bars as directed complete. Providing and applying bonding coat of slurry made out of “Polyalk EP” or equivalent as specified in the Brand Names and cement in proportion 1:1 to concrete and r/f substrates complete as directed Providing and applying “Polyalk EP” or equivalent as specified in the Brand Names. Polymer modified cement mortar in Required proportions (1:5:15) to RCC members Including Hand packing, curing and making the surface rough for plastering.
13Taking down existing bitumen felt roof treatment/mud phuska including cement mortar bedding or roof tile and cleaning the surface by brooming, wire brushing, removing grass and removing debris, grass etc, complete all as specified and directed by Engineer-in-Charge. Note :- Rate of this item is inclusive of disconnect fitment of water tank /solar heater/ E&M installation etc and refixing in the same position after compeleting of roof treatment.
14M&L for 40mm thick PCC (1:2:4) type B-1, using 20 mm graded mechanically crushed stone aggregates as in padding to roof to maintain the required slope and finished the surface even and smooth without using extra cement, complete all as specified and directed.
15Material and labour, 10mm thick cement plaster over roof in CM (1:4) mixed with WPC as per manufacturer’s instructions on concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed. Note : WPC shall be measured and paid separately.
16M&L water proofing treatment of roof consisting as under:- (a) Applying evenly a coat of bituminous primer conforming to IS-3384:1986 @ 0.30 litre/sqm including preparation of roof surfaces (b) Applying evenly a tack coat of industrial bitumen 85/25 @ 1.2 kg/Sqm on plaster surface all as specified.(c) A layer of 3mm thick APP polymeric membrane of weight not less than 3.60 kg/sqm, reinforced with polyester non-woven fabric (weight not less than 160gm/sqm), duly sealed at over laps & joints with end laps of the 10cm and side over laps of 7.5cm by flame (by torch application) all as per manufacturer’s instructions, complete all as specified and directed.
17Supply only water proofing liquid compoundcomplete all as specified and directed by Engr-in-Charge.
18M&L Appling two coat Bitumen water proofing aluminium heat resistance paint over the APP as per manufacture instructions complete all as specified and directed by Engr-in-Charge.
19Supply and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner complete all as specified & directed by Engr-in-charge.
20M&L for providing and applying smart care Dampproof, a fibre reinforced elastometric liquid water proofing membrane formulated with reinforced acrylic fibres having Sun Reflective Index (SRI) of 105 on horizontal/ vertical surfaces of roof/ wall/ chajjas in multiple costs @2.0 litre/ sqm. Primary coat is self-priming coat of elastomeric waterproofing liquid (Dilition with water in the ratio of 3:1, damp proof : Water) and other coat to be applied undiluted. The coating needs to be reinforced with 40GSM Geotextile, to sandwiched between 2nd & 3rd coat of coating. The application shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes complete in all respect as per the direction of Engineer-in-Charge. Make : SmartCare Damp Proof of Asian or equivelent in Berger/ Nerolac/ STP only.Notes:(1) The work shall be executed through authorised appplicatot of manufacturer only.(2) Authorised Applicator shall be approved by GE befor starting the work.(3) All materials shall be produced directly from manufacturer. The purchase voucher shall be produced to the Engineer-in-Charge for his verification of material. Engineer-in-Charge shall deface the original purchase voucher/
21Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
22M&L for Mild Steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc. of Gde Fe-290, complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing including one shop coat of zinc chromate primer paint (including preparation of surface) at Contractor’s workshop before fabrication complete all as specified and directed.
23S&F 1.00 mm thick plain black steel sheet in hearths; covering to door shutters; covering to doorchowkats (frames); chullah hoods; water tanks; water troughs; ducts; urinal troughs and funnels, etc. cut to size edges beaded if directed, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel members, etc., with plain 40 mm lap joints or welded/ riveted seams including bending, turning up, mitred angles, stopped ends, outlets, etc. as required incl priming complete all as specified and directed.
24Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering complete all as specified and as directed.
25S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour as approved having tensile strength of 550 Mpa as in roof covering/cladding to wall as view cutter, fixed with self tapping screws as specified and including cutting chasing of wall, complete all as specified and directed.
26Excavating in any type of soil in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface.
27Demolition in cement concrete of cement concrete in ground floor and paving not exc. 15 cm thick below or above ground level complete all as specified and as directed.
28M&L 75mm thick PCC 1:4:8 type D-2 (40 mm graded stone agg) as in Sub base to receve floor finishes etc complete all as specified and directed.
29M&L for Rubber moulded PU coated Chequered cement concrete tiles 300mmx300mm and 25mm thick, set, jointed with grey cement and pigments and pointed in neat cement slurry icluding screed bed or bedding layer of cement mortar 1:6, 15mm thick for laying floor finished complete all as specified and directed.
30M&L 100mm thick Cement concrete type D-2,1:4:8 (using 40 mm gradd aggregate) graded stone aggregate in sub base of floor complete all as specified and directed by Engr-in-Charge.
31S&F Machine pressed precast concrete interlocking glazed paver block with grey/ colour cement and pigment of any shape and size conforming to IS 15658 - 2006 of 60 mm thickness and M-35 grade including 50 mm sand cushion including packing joints etc complete all as specified and directed.
32M&L for cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate as in coping and similar works including necessary form work complete all as specified.
33M&L for 100mm thick Ready Mixed Cement Concrete ( M-25) as stamp concerting in floors, sub base, base etc & preparing a concrete floor with a textured, imprinted finish to resemble natural materials like stone or brick. The process includes preparing a base, pouring concrete, applying color hardener, and using release agents and stamps to create the desired pattern. Finally, the surface is sealed for protection and enhanced color including formwork to edges of concrete flats, breaks in floors, openings in concrete floors ,horizontal or sloping complete all as specified and directed by Engr-in-charge.
34M&L for hard core using broken stone or boulders of gauge not exc 63mm, deposited, spread, levelled, watered and well rammed to a true surface, complete all as specified and directed by Engineer-in-Charge.
35M&L for Parking tile/Out Door coloured ceramic tiles (desired pattern) 10 to 12mm thick (square/ rectangular) area of each tiles exceeding 0.09 sqm but not exceeding 0.36 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over with 15mm thick screed bed in CM 1:6 inculding dismantling of tile complete all as specified.
36M&L for providing PMM (Polymer modified cementitious mortar):- (i) Dry sub strate surface and free of debris & dust. (ii) Applying Epoxy bond coat on the sound substrate using approved spray machine & ensuring that no pin holes are visible. (In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes. (iii) Immediately after application of epoxy bond coat as above apply PMM (Polymer modified cementitious mortar) of 25 mm thickness. Note : Application of PMM shall be pre packed ready to use. (iv) PMM surface to be moist cured for three days followed by air curing in temperature as recommended by manufacturer complete all as specified and directed.(Note: The work shall be exicuted in G+ 8th floor Height)
37M&L two coats of Damp Proof application shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge. (Note: The work shall be exicuted in G+ 8th floor Height)
38M&L preparation of new/old steel surface and apply two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
39M&L for preparation of new/old stone/ concrete surface of any description over 10cm girth or width, not otherwise described and applying two coat of synthetic enamel paints over priming paint plaster complete all as specified and directed.
40Disposal of building rubbish/malba, similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading and disposal at an approved Municipal dumping ground outside Defence land (MoD land), for all leads and all lifts, complete all as specified and as directed by the Engineer-in-Charge.Notes:1. Photographic Evidence: The contractor shall submit clear photographic evidence in support of disposal of building rubbish/malba, similar unserviceable, dismantled or waste materials, indicating the condition of the site before loading, during transportation and after unloading at the approved Municipal dumping ground. The photographs shall preferably be geo-tagged and date-stamped and shall form part of the record for verification and payment purposes. 2. Certification by Engineer-in-Charge: Completion of whole work in this BOQ shall be deemed to have been achieved only after certification by the Engineer-in-Charge that no building rubbish/malba, similar unserviceable, dismantled or waste materials have been left at the site and that the site has been thoroughly cleared and cleaned to his satisfaction. 3. Each load shall comprise a minimum carrying capacity of 5.00 cubic metres (Cum). Payment under this item shall be made on a per-load basis for loads conforming to the above minimum capacity and duly verified by the Engineer-in-Charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58320649
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 48 Lakhs
LAST DATE 21-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for External Periodical Services Incl Connected B/R Services, Repairs To Chajja And External Plastering Works Etc In The Area Of Age B/R-Ii Under Ge (East) Delhi Cantt-10
Basic Detail
Tender No GE/DE-187/2026-27
Bidding Type Tender
Location
City New Delhi
State Delhi
Key Dates
Publish Date 31 Oct 2026
Submission Date 21 Nov 2026
Open Date 23 Nov 2026
Finance
Tender Value 48 Lakhs
Tender Fee 500
EMD 96000
Exemption Available
Document List
0f0da61c-3631-4fd9-92a8-e2ee2de31c6e.html
BOQ_893595.xls
Tender187.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 31, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Nov 23, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 1 day

Tender Documents

Download All (ZIP) ↓
html

0f0da61c-3631-4fd9-92a8-e2ee2de31c6e.html

xls

BOQ_893595.xls

pdf

Tender187.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender