Tender For Repair To Roof, Chajja, Facia, Joinery, Plastering And Allied Works In Command Colony, Madhumati Colony, Kpq/ Csq Colony At Chandimandir Mil Stn Under Ge Chandimandir.

Issued by Statutory Bodies & Commissions/Committees · Panchkula, Haryana
Tender Value
75 Lakhs
Estimated cost
Bid Submission
02 Dec 2026
10 days left
EMD
1.37 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Panchkula → Haryana
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair To Roof, Chajja, Facia, Joinery, Plastering And Allied Works In Command Colony, Madhumati Colony, Kpq/ Csq Colony At Chandimandir Mil Stn Under Ge Chandimandir.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 21-Nov-2026 Revision of BOQ and schedule of credit BOQ 02-Dec-2026
2 21-Nov-2026 Amdt1 Date 02-Dec-2026

BOQ

Name of Work:- REPAIR TO ROOF, CHAJJA, FACIA, JOINERY, PLASTERING AND ALLIED WORKS IN COMMAND COLONY, MADHUMATI COLONY, KPQ/ CSQ COLONY AT CHANDIMANDIR MIL STN UNDER GE CHANDIMANDIR.
Sl. No. Item Description
1Note all items of BOQ: The work shall be carried out to the 2 storey building (height upto 8 metres). Necessary arrangement for carrying out the work including labour, equipment, scaffolding, safety appliances transportation of materials shall be provided by the contractor within overall rate quoted against the items of this schedule and no claim whatsover shall be admissible on this account at later stage. Contractors are requested to quote their rates accordingly keeping this aspect in mind.
2Demolition of brick or stone masonry, built in cement mortar including all quoins, arches, pillars etc., but excluding ashlar facings, dressed stone complete all as specified and as directed by Engineer-in-Charge.
3Material and labour for brick work with sub class ‘B’ bricks (old size bricks), straight or curved on plan, exceeding 6.00 metre mean radius, built in cement mortar 1:4 complete all as specified and as directed by Engineer-in-Charge.
4All as per Serial item No 2.00 here-in-before but except bricks (using old serviceable bricks obtained from demolition of brickwork here-in-above) complete all as specified and as directed by Engineer-in-charge.
5M&L for Brickwork with sub-class ‘B’ bricks (old size bricks), straight or curved on plan to any radius in half brick thick walls, for partition wall, parapet in balcony and other similar work built in Cement Mortar 1:4 complete all as specified and as directed by Engineer-in-Charge.
6Taking down cement plaster of any description on brick, concrete or stone walls including raking out joints, hacking for key, scrubbing down with water, etc including removing all debrish from defence land arrangement complete all as specified and as directed by Engineer-in-Charge.
7M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces at any height including walls, cornices, chajjas, sun shades etc., in cement mortar 1:4, finished even and smooth without using extra cement including necessary scafolding or shuttering complete all as specified and directed by Engineer-in-Charge.
8M&L for rendering 15 mm thick on fair faces of brick work or concrete surface in cement mortar 1:6, surface finished even and smooth without using extra cement at any height, including
9M&L for 10 mm thick rendering in cement mortar 1:3 as in ceiling, chajja, facia at any position on concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed By Engineer-in-Charge.
10M&L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper (Ist quality) over a coat of primer, complete all as specified and as directed by Engineer-in-Charge.
11M&L for preparing newly plastered wall surfaces and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm / litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, paint applied @ 1.43 litre/ 10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surface complete all as specified and directed by Engineer-in-Charge.
12M&L for preparation of plastered or unplastered new decorated surfaces of ceiling and applying three coat of white lime wash complete all as specified and as directed by Engineer-in-Charge.
13M&L taking down, chipping and removing the loose, spailt, damaged cement concrete, cement mortar surfaces of RCC columns, beams, walls, Chajjas etc and exposing the reinforced cement, wire brushing and cleaning the exposed steel reinforced bars, apply rust remover over the cleaned re-bar surface wash the re-bar with clean water for removing all rusts from the old re-bar surfaces, fixing new reinforcement for strenthen the members as required, applying two coats of epoxy zinc primer on new and old steel surfaces, saturate the substrate with water applying one coat of polymer modified cement and quartz sand mortar in cement mortar 1:3 mix 40mm average thick in two coats, with and including polymer @ 10% by weight of cement complete all as specified and as directed by Engineer-in-Charge.
14M&L for preparation of old plastered surfaces of wall and applying one coat of Oil Bound Distemper of any tint, as ordered complete all as specified and as directed by Engineer-in-Charge.
15M&L for complete removal of existing treated surfaces of wall and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm / litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, paint applied @ 1.43 litre/ 10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surface complete all as specified and directed by Engineer-in-Charge.
16M&L for preparation of old treated surface of ceiling & applying one coat of white wash complete all as specified and as directed by Engineer-in-Charge.
17S&F welded steel wire fabric, weight not exceeding 4 kg per square metre, cut to length, fixed to steel members/ resistance steel complete all as specified and as directed by Engineer-in-Charge.
18Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exceeding 1.50 sqm each including making good the disturbed surfaces complete all as specified and as directed by Engineer-in-Charge.
19Taking down chowkats or frames with shutters (without taking off shutters from the frames) exceeding 1.5 sqm and not exceeding 4.00 sqm each including making good the disturbed surfaces complete all as specified and as directed by Engineer-in-Charge.
20Taking down shutters exceeding 1 sqm but not exceeding 2 sqm each & removing from site complete all as specified and as directed by Engineer-in-Charge.
21Resecuring or easing & adjusting in the same opening, shutters of any description of size exceeding 1.00 sqm and not exceeding 2.00 sqm complete all as specified and as directed by Engineer-iin-Charge.
22S&F Flush shutters, 30 mm thick for door shutter, solid core construction, with block board core and plywood face panels, commercial type on both side complete all as specified and as directed by Engineer-in-Charge.
23Supply and fixing 200 mm size aluminium anodised barrel tower bolts (ISI marked) of extruded section fixed complete all as specified and as directed by Engineer-in-Charge.
24Supply and fixing aluminium alloy, anodised, sliding door bolt (ISI Marked) 250 mm long hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy, fixed complete all as specified and directed.
25S&F 100mm size butt hinges, extruded aluminium alloy with galvanised mild steel hinges pin, type B-21, ISI marked complete all as specified and as directed by Engineer-in-Charge.
26S&F extruded aluminium alloy handles with plates, fabricated type, anodised 150 mm size, ISI marked, complete all as specified and as directed by Engineer-in-Charge.
27M&L for preparation of new wooden surfaces of any description, not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed by Engineer-in-Charge.
28M&L for preparation of new steel surfaces of any descripetion over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces of any description complete all as specified and as directed by Engineer-in-Charge.
29S&F 15 mm bore tubes, medium grade, galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete including taking down old GI pipe with all fittings complete all as specified and directed by Engineer-in-charge.
30S&F 20 mm bore tubes, medium grade, galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete including taking down old GI pipe with all fittings complete all as specified and directed by Engineer-in-charge.
31M&L for Cutting chases, pinning in, of brick walls or concrete surfaces, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of inserting sheets, landings, steps, sills, sunshades, shelves, lintels, etc.; for concealed water tubing, concealed conduit wiring etc., and making good, cutting not exceeding 10 cm girth complete all as specified and directed by Engineer-in-Charge.
32S&F framed work such as grills, grating, etc., with ends of bars shouldered and/ or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work for water tanks and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed by Engineer-in-Charge.
33Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan necks etc. including cleaning or refixing or removal to store complete all as specified and as directed by Engineer-in-charge.
34Supply and fixing PVC (SWR) pipes, 110 mm bore, single socketed, in any length with rubber ring joints, of pressure rating 6 kgf/cm2, fixed to walls, with MS/ GI clamps made out of flat iron of size 25 mm x 3 mm including nuts, bolts etc., complete all as specified and as directed by Engineer-in-Charge.
35S&F PVC (SWR) Bend, 110 mm bore complete all as specified and as directed by Engineer-in-Charge.
36Supply and fixing PVC (SWR) pipes, 75 mm bore, single socketed, in any length with rubber ring joints, of pressure rating 6 kgf/cm2, fixed to walls, with MS/ GI clamps made out of flat iron of size 25 mm x 3 mm including nuts bolts etc., complete all as specified and as directed by Engineer-in-Charge.
37S&F PVC (SWR) Bend, 75 mm bore complete all as specified and as directed by Engineer-in-Charge.
38S&F Rotational moulded PVC, Triple layered, water storage tanks of capacity 1000 litre (cylindrical vertical with closed top), ISI Marked, hoisted and fixed in position all as specified in SSR Part I, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etc., and including 20 mm size Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe including dismantling existing water tank complete all as specified and as directed by Engineer-in-Charge.
39S&F Rotational moulded PVC, Triple layered, water storage tanks of capacity 500 litre (cylindrical vertical with closed top), ISI Marked, hoisted and fixed in position all as specified in SSR Part I, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etc., and including 20 mm size Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe including dismantling existing water tank complete all as specified and as directed by Engineer-in-Charge.
40Disconnecting existing tanks of capacity exceeding 500 litres and not exceeding 1000 litres, setting aside (or lowering if required) including cleaning and removing all scale and dirt, etc. from tanks and from mouths of circulating pipes, reconnecting and re-fixing in position after cleaning complete all as specified and as directed by Engineer-in-Charge.
41Disconnecting existing tanks of capacity exceeding 250 litres and not exceeding 500 litres, setting aside (or lowering if required) including cleaning and removing all scale and dirt, etc. from tanks and from mouths of circulating pipes, reconnecting and re-fixing in position after cleaning complete all as specified and as directed by Engineer-in-Charge.
42Dismantling Plain or corrugated sheeting, any gauge, thickness, including Nainital or similar pattern roof covering including stacking properly complete all as specified and as directed by Engineer-in-Charge.
43Supply and fixing Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet, 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and as directed by the Engineer-in-Charge.
44Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed by Engineer-in-Charge.
45S&F Rolled/ Tubular sections as in main and cross beams, hip and jack rafters; purlins, posts where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates, Fe-410-W (Gde-Fe-250) quality-B complete all as specified and as directed by Engineer-in-Charge.
46Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed by Engineer-in-Charge.
47M&L for Providing cement concrete 1:2:4, type B-0 (using 12.5 mm graded aggregates) as in roof kerbs or mud stops, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs including weathering, slightly rounded or chamfered angles and throating on edges complete all as specified and as directed by Engineer-in-Charge.
48M&L for 75mm thick cement concrete 1:3:6, type C-2 (using 40mm graded crushed stone aggregate) as in plinth p[rotection finished the concrete surface even and smooth without using extra cement including bitumen mastic in grooves with 80/25 bitumen and coarse sand mixture 1:3 by weight complete all as specified and as directed by Engineer-in-Charge.
49Dismantling of existing brick tiles or terracing tiles single layer on roof, grouted in cement mortar complete all as specified and as directed by Engineer-in-Charge.
50Demolition of mud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof) including removal of rubbish off the premises complete all as specified and as directed by Engineer-in-Charge.
51M&L for Plain cement concrete 1:2:4, type B-1 (using 20 mm gaded stone aggegate) in roof kerbs, roof padding or mud stops, rounded or chamfered on edges complete all as specified and as directed by Engineer-in-Charge.
52M&L for cement concrete tiles 25 cm x 25 cm x 22 mm thick with grey cement, machine pressed; set jointed and pointed in neat cement slurry on roof, laid over and including 15 mm thick screed bed or bedding layer in Cement Mortar 1:4 for laying floor finishes complete all as specified and as directed by Engineer-in-Charge.
53M&L for cutting/ uprooting of trees/ plants upto 25 cm girth from mumty/ roof/ walls/ parapet and sprinkling anti-vegetative chemical/ acid growth and making good to surface including arrangement of necessary scaffolding and safety measures complete complete all as specified and as directed by Engineer-in-Charge.
54Demolition of existing RCC Water Tanks upto 500 litres capacity including removing debrish from site complete all as specified and as directed by Engineer-in-Charge.
55Demolition of Reinforced Concrete (reinforcement cut as required to facilitate demolition) of roofs, beams, staircases, landing, chajjas, balcony, parapets and similar suspended work including removal of rubbish to any lead outside MD land, complete all as specified and as directed by Engineer-in-Charge.
56Material and labour for waterproofing treatment to roof complete in the following stages including removal of existing APP membrane from roof:- (a) SURFACE PREPARATION: Cleaning top surface of roof/ RCC slab using electric wire cup grinder to remove surface imperfections, sharp edges or protrusions at the junctions to achieve a uniform surface profile. Cleaning thoroughly the concrete surface using a high-pressure water jet to eliminate all dirt, dust, oil spillage, laitance, and other contaminants. (b) SURFACE CRACK REPAIR: Cracks on top surface/ RCC slab wider than 1 mm required to be cut and open in V-groove manner (8 mm wide x 6 mm deep) by using mechanical cutter, clean the same and fill with high modulus, moisture curing, silyl modified polymer (hybrid)/Poly sulphide base sealant and allow sealant to air cure for 3 days.Make:- Pidilte Dr. Fixit feviseal HY300 or FOSROC Nitoseal-300 or equivalent product in STP
57(c) ANGLE FILLET TREATMENT: Providing and preparing angle fillet at all vertical up stands and junctions/ corners. Moist the surface with water, apply bond coat prepared by mixing universal repair polymer (URP) and cement in 1:1 ratio by volume and apply using brush, preparing PMM by mixing 1 kg of URP, 5 kg fresh cement and 15 kg graded quartz sand, (i.e. in the ratio of 1:5:15 or as specified as per manufacturer's instructions and preparing angle fillet (gola) of size 50 mm x 50 mm over the wet bond coat and finishing the same followed by moist curing the surface for 48-72 hours complete.Make:-Pidilite Dr. Fixit Pidicrete URP/FOSROC Nitobond SBR Latex/ STP Shali SBR Latex.
58(d) RAINWATER OUTLET TREATMENT: Hacking and chipping the surface around the rainwater drain outlet up to 25 mm in depth, applying bond coat of universal repair polymer (URP), in ratio of 1:1 (URP 1 : cement 1) by volume, over the corners and pipe insert outlet gaps, filling the gaps around drain mouth with PMM (Polymer Modified Mortar), mixed with universal repair polymer (URP) 10% by weight of cement, in the ratio 1:3 or as specified as per manufacturer's instructions. Providing and fixing 100 mm width, 225 GSM, fiber glass chopped strand mat around the periphery of drain mouth of rainwater outlet, sandwiched with two-component UV resistant poly urethane waterproof top coat. Applying two thick coats of two-component UV resistant poly urethane waterproof coating to completely cover the mesh/ fabric and surrounding area.
59(e) WATERPROOFING APPLICATION: Preparing premix of two-component high-strength poly urethane waterproofing coating using an polyelectric double paddle mixer at low speed for 2-3 minutes until a uniform blend is achieved without dilution. Applying the waterproofing coating on an SSD (Saturated Surface dry) condition, apply first coat mix at the rate 0.8-0.9 kg/sqm using a lamb's wool roller or as specified as per manufacturer's instructions. While the coating is still wet, roll and embed a 225 gm fiberglass chopped strand mat ensuring full bonding without air bubbles or wrinkles and overlap joints by at least 5 cm at end points & allow the first coat to dry for 3-4 hours. Applying the second coat at 90 degrees angle to the first coat at 0.9 kg/sqm or as specified as per manufacturer's instructions, once the surface is dry enough to walk on. Additional coats may be applied as required to achieve a forced material consumption to obtain a DFT of 1000 to 1200 microns with minimum material consumption of 1.8 kg/sqm over 2-3 undiluted coats or as specified as per manufacturer's instructions. The coating should terminate below the drip mold on vertical surface. Make: Two components UV resistant Poly Uretherane elastomeric water proof of Pidilite Dr. Fixit Wonder Proof 100/ STP Shaliuretherane LHM 2K80 or equivalent in FOSROC
60M&L for Expansion joints complete all as specifified as under:-Prepare the joint/crack by thoroughly removing all loose material, dust, laitance, and debris from the substrate. Ensure that the substrate moisture content is less than 4% prior to application.Mix the two-component, solvent-free, high-performance thixotropic epoxy adhesive in the manufacturer's recommended proportions and mechanically stir for 2–3 minutes until a uniform and homogeneous mixture is obtained.Apply the mixed adhesive on both sides of the prepared crack/joint to a thickness of approximately 1–2 mm using a notched trowel or suitable spatula. Select a flexible seal tape of width 50–75 mm, or as required depending upon the joint/crack width. Ensure that the central portion of the tape remains unbonded by placing a foam backer rod and applying masking tape over the joint prior to adhesive application. Remove the masking tape from the joint centre immediately before positioning the seal tape.
61Contd.Place the seal tape within the adhesive open time and firmly press it into position using a suitable roller to eliminate air pockets and ensure full contact with the adhesive. After the base adhesive layer has sufficiently set, apply a second adhesive coat approximately 1 mm thick over the entire width of the seal tape. Remove any remaining masking tape immediately to obtain a neat and uniform finish.At tape terminations and end laps, clean the overlapping surfaces thoroughly and heat-weld the overlaps for a minimum length of 100 mm using a hot-air welding gun. Allow the completed system to cure for a minimum period of 7 days or as recommended by the manufacturer.The finished crack-bridging system shall exhibit an elongation at break of not less than 500%, tensile strength of not less than 12 N/mm², and high tear resistance, complete in all respects and in accordance with the manufacturer's specifications and directions.
62Supply and laying non-woven geotextile membrane of minimum 100 GSM, laid loosely over the completed waterproofing membrane including all necessary cutting, alignment, and positioning, with minimum 100 mm overlap at all joints, complete in accordance with the manufacturer's specifications and directions as approved by the Engineer-in-Charge
63M&L for repair of damaged roof screed and formation of slope Removing all loose, damaged, and deteriorated concrete/screed from the roof surface in required pockets using mechanical cutters and suitable tools. Clean the prepared surface thoroughly with high-pressure water jetting to remove dust, dirt, laitance and all loose particles. Applying a bonding coat comprising Universal Repair Polymer (URP) mixed with cement in the ratio of 1:1 by volume or as specified as per manufacturer's instructions to form a lump-free slurry. The bonding coat shall be applied uniformly on the pre-wetted substrate immediately before placing the repair mortar/concrete,
64contd.. laying roof screed to the required slopes and gradients using M20 grade polymer-modified concrete/mortar prepared in the proportion of 1 : 1.5 : 3 (cement : sand : coarse aggregate) or as specified as per manufacturer's instructions. Universal Repair Polymer shall be added at 10% by weight of cement. Placing, compacting, levelling and finishing the screed to the required line, level, and gradient using suitable trowels and finishing tools. The repaired surface shall be kept continuously moist and cured for 7 days, followed by air curing for 4-5 days or as recommended by the manufacturer before application of the waterproofing system. The work shall be carried out complete in all respects in accordance with the manufacturer's specifications and the directions of the Engineer-in-Charge.
65Note for Srl item No. 55 to 61: 1. The work shall be carried out to the 2 storey building (height upto 8 metres). Necessary arrangement for carrying out the work including labour, equipment, scaffolding, safety appliances transportation of materials shall be provided by the contractor within overall rate quoted against the items of this schedule and no claim whatsover shall be admissible on this account at later stage. Contractors are requested to quote their rates accordingly keeping this aspect in mind.2. The work pertaining to water proofing treatment shall be executed as per MoU among contractor, manufacturer of waterproofing material and applicator as per MoU performa attached at Serial page No. 132 to 138. Authorized applicator of the company with trained/ skilled worker will only be allowed to execute the work and the applicator will submit the authorization and experience certificate from the company. 3. The Contractor shall upload with the documents under cover I \\"Memoradum of Understanding\\" (MoU) with at least one of the manufacturers (Pidilite/ Fosroc/ STP) failing which the bid shall not be opened and shall liable to be rejected. Also, all the materials shall be procured from single manufacturer and accordingly MoU shall also be signed with one Manufacturer only.
664. The entire quantity of material will be calculated and brought on site as decided by Engineer-in-Charge and will be accepted only post-verification of PVs and challan from company through mail. 5. Material will be kept in the custody of MES rep and will be issued to the authorized applicator as per requirement. 6. Each stage will be properly executed under supervision of company rep and stage passing register will be properly maintained. 7. The contractor shall submit manufacturer generated 10 years warranty card during submission of final bill
678. A guarantee amount @10% against water proofing treatment will be kept as a reserve till completion of warranty period and will be released thereafter.9. Any deterioration during warranty period will be rectified by the contractor from the manufacturer with whom the MoU is signed, without any financial effect. 10. Ponding tests shall be carried out for 72 hours after completion of roof treatment and ponding shall be done by applicator with company technical rep as per manufacturer's instructions and finally passed as directed by GE.11. The technical data sheet incorporated in the MOU specifies various parameters of the chemical waterproofing system. Particular emphasis will be given on values of parameter for tear strength, tensile strength, DFT, crack bridging capability, permeability, and the overall guarantee period. The values specified by the original manufacturer shall not be less than the corresponding stipulated values for the above mentioned parameters. However, a variation in any other parameter may be considered, provided that such variation does not result in any significant deficiency or adversely affect the overall performance and effectiveness of the waterproofing system. Such variation in other parameters shall not, by itself, constitute a ground for rejection of the material. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58320636
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 75 Lakhs
LAST DATE 02-12-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair To Roof, Chajja, Facia, Joinery, Plastering And Allied Works In Command Colony, Madhumati Colony, Kpq/ Csq Colony At Chandimandir Mil Stn Under Ge Chandimandir.
Basic Detail
Tender No CWE/CHM-75/2026-27
Bidding Type Tender
Location
City Panchkula
State Haryana
Key Dates
Publish Date 21 Nov 2026
Submission Date 02 Dec 2026
Open Date 01 Jan 0001
Finance
Tender Value 75 Lakhs
Tender Fee 1000
EMD 1.37 Lakhs
Exemption Not Available
Document List
Additional75.pdf
BOQ_893591.xls
cc8a5cd8-62b5-407d-b802-d3090abb807b.html
Tenderdocuments75.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 21, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 02, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 10 days
Dec 02, 2026
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 10 days
Dec 02, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days