Tender For Repair/Maint Of Summer & Cooling Appliances In Txr And Technical Area At Af Stn Sonegaon.
Tender Value
8.10 Lakhs
Estimated cost
Bid Submission
21 Nov 2026
0 days left
EMD
16200
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Nagpur → Maharashtra
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Maint Of Summer & Cooling Appliances In Txr And Technical Area At Af Stn Sonegaon.
BOQ
| Sl. No. | Item Description |
| 1 | S & F MCB, Single pole, 6 to 32 amps, 240 volts, ‘C’ curve, 10 KA complete all as specified and as directed. |
| 2 | S & F in replacement single pole and neutral enclosure with a two pin and earth plug and socket complete with single pole MCB 20 amps capacity complete all as specified and directed. |
| 3 | S & F in replacement metal clad plug two pin and earth complete all as specified and directed. |
| 4 | M & L for sub main wiring with 2 run of 4 Sqmm (Nominal cross-sectional area) PVC insulated unsheathed single core flame retardant low smoke cable (FRLS) of working voltage 1100 volts grade with stranded copper conductor including one run of 2.5 Sqmm (Nominal cross sectional area) PVC insulated unsheathed flame retardant cable (FR) with stranded copper conductor as continuous earth wire connected to main switches DBs or in common earth dolly drawn with and including 20 mm dia PVC rigid non- metallic conduit after and including taking down / dismantling old sub main wiring including old conduit / casing capping / wooden batten etc of any description complete all as specified and as directed. |
| 5 | Taking down and supply and fix new compressor including pumping out oil, cleaning the refrigeration system with Co2 and charging refrigerant gas (R-22/R-32) providing NRV for further topping up of gas and re-fixing in the position including complete testing and commissioning suitable for 1.5 TR capacity split type Air conditioner inverter / non inverter type complete all as specified and as directed. |
| 6 | Taking down and supply and fix new compressor including pumping out oil, cleaning the refrigeration system with Co2 and charging refrigerant gas (R-22/R-32) providing NRV for further topping up of gas and re-fixing in the position including complete testing and commissioning suitable for 2 TR capacity split type Air conditioner inverter / non inverter type complete all as specified and as directed. |
| 7 | All as per item No. 5.00 here in before but suitable for refrigerator 180 to 310 ltrs capacity. |
| 8 | All as per item No.5.00 here in before but suitable for Deep freezer for 320 ltrs capacity. |
| 9 | All as per item No. 5.00 here in before but suitable for Water cooler 80/40 capacity.Note for Sl item No 5.00 to 9.00: - Rate deemed to be inclusive of filling/Gas charging. |
| 10 | Repair to voltage stabilizer for automatic low and high voltage correction boost / buck transformer by rewinding the transformer coil, replacement of selector switch, PC board, time relay, indicator lamp and three core cable cord with plug top and voltmeter for the following sizes: - |
| 11 | Voltage Stabilizer 5 KVA capacity |
| 12 | Voltage Stabilizer 3/4 KVA capacity |
| 13 | Voltage Stabilizer 01 KVA capacity |
| 14 | S & F in replacement PCB (Printed circuit board) suitable for 1.5/2.0 Ton of split type Air conditioners complete all as specified and as directed. |
| 15 | M & L for Leak test with Co2/ Nitrogen gas arrest leakage with brazing of copper pipe and charging refrigerant gas R- 410A/ R-22, R-32 for AC capacity 1.5/2 TR Split Type Air conditioner complete all as specified and as directed. |
| 16 | Material and labour for Leak test with Co2/ Nitrogen gas arrest leakage with brazing of copper pipe and charging refrigerant gas R-12 /R-134 for following cooling appliances. |
| 17 | Refrigerator |
| 18 | Water Cooler |
| 19 | Deep freezer |
| 20 | S & F for Rigid PVC flexible hose of 15 mm dia 2.5 mtr length with all accessories fixed on wall /ceiling/ roof etc with suitable GI saddles and screws for connect with split type AC/water cooler as drain pipe complete all as per specified and as directed. |
| 21 | Supply and replace with new fan leaf unit suitable for Air conditioner of capacity 1.5TR/2 TR complete all as specified and directed. |
| 22 | Supply and replace with new remote control unit suitable for Air conditioner complete all as specified and as directed. |
| 23 | Supply and replace with new condenser coil unit made of copper suitable for the following capacity split Air conditioner complete all as per specified and as directed. |
| 24 | 1.5 ton capacity |
| 25 | 2.0 ton capacity |
| 26 | Supply and fix in repair Starting capacitors for following cooling appliances: - |
| 27 | Split type Air Conditioner |
| 28 | Refrigerator |
| 29 | Deep Freezer |
| 30 | Water Cooler |
| 31 | Supply and fix in repair Running capacitors for following cooling appliances: - |
| 32 | Split type Air Conditioner 1.5/2/3 TR |
| 33 | Refrigerator |
| 34 | Deep Freezer |
| 35 | Water Cooler |
| 36 | Supply and fix in repair Thermostatic switch for following cooling appliances: - |
| 37 | Split type Air Conditioner |
| 38 | Refrigerator |
| 39 | Deep Freezer |
| 40 | Water Cooler |
| 41 | Supply and fix in repair Fan Motor for following cooling appliances: - |
| 42 | Split type Air Conditioner (Outdoor) |
| 43 | Refrigerator |
| 44 | Deep Freezer |
| 45 | Water Cooler |
| 46 | S & F in repair indoor unit blower Fan Motor for 1.5/2 Ton Split type Air conditioner complete all as specified and as directed. |
| 47 | S & F in replacement suction valve 1.5/2 TR capacity split type Air conditioner complete all as specified and as directed. |
| 48 | S & F in replacement discharge valve 1.5/2 TR capacity split type Air conditioner complete all as specified and as directed. |
| 49 | S & F in replacement flare nut of size 5/8 inch complete all as specified and as directed. |
| 50 | S & F in replacement flare nut of size 1/2 inch complete all as specified and as directed. |
| 51 | S & F in replacement flare nut of size 1/4 inch complete all as specified and as directed. |
| 52 | S & F in replacement flare nut of size 3/8 inch complete all as specified and as directed. |
| 53 | S & F in replacement mounting stand for split AC 1.5/2 TR capacity complete all as specified and as directed. |
| 54 | S & F in replacement PCB (Printed circuit board) suitable for Indoor 1.5/2.0 TR Inverter split type Air conditioners complete all as specified and as directed. |
| 55 | S & F in replacement PCB (Printed circuit board) suitable for Outdoor 1.5/2.0 TR Inverter split type Air conditioners complete all as specified and as directed. |
| 56 | S & F in replacement PCB (Printed circuit board) suitable for refrigerator any type any size complete all as specified and as directed. |
| 57 | S & F in replacement voltage stabilizer 4 KVA range 170 to 260 Volts, output voltage 230 volts AC supply 50 HZ having low and high voltage protection, intelligent time delay system, wall mounting type including mounting accessories time delay 180 seconds +/- 20 seconds as initial time delay complete all as per Volina or equivalent in AE / V - Guard complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 58 | S & F in replacement voltage stabilizer 4 KVA range 170 to 260 Volts, output voltage 230 volts AC supply 50 HZ having low and high voltage protection, intelligent time delay system, wall mounting type including mounting accessories time delay 180 seconds +/- 20 seconds as initial time delay complete all as per Volina or equivalent in AE / V - Guard complete all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 31, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 21, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
TodayNov 28, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓