Project Description

Tender for Repair/Maintenance Of Transformer And 11 Kv Network With Allied Works At Mil Stn Kanasar Under Ge(N) Bikaner

BOQ

Name of Work:- REPAIR/MAINTENANCE OF TRANSFORMER AND 11 KV NETWORK WITH ALLIED WORKS AT MIL STN KANASAR UNDER GE(N) BIKANER
Sl. No. Item Description
1Disconnecting supply of transformer HT oil cooled aluminium/copper wound of capacity 63 KVA to 200 KVA, 11 KV graded from installed position on sub station, after disconnecting complete electric supply from HT and LT sides including earthing strips for transporting to factory/ workshop/ authorised service centre and back, draining out complete transformer oil and keeping in safe custody in clean and dry containers for re-use of transformer oil, opening top cover for checking the serviceability of coil winding, conditiong of body after repair/rewinding to carry out necessary repairs as on required basis, providing all insulating material like sleeves, tapes, kerb tapes, cork sheet etc, after checking and make functional of tap changer including replacement of unserviceable items (where required) as directed and installing in its original position and making all electric connections with thimbles & PG clamps and testing complete all as specified and as directed.Notes:- (i) Labour component required for the replacement of unserviceable parts shall deemed to be included in the unit rate quoted against this item.(ii) Major Parts (as required) and Transformer Oil shall be measured and paid for separately as under relevant items of this Schedule.(iii) All minor parts such as nuts, bolts, washers, insulating material, copper wire for delta connection, etc. shall be arranged by the contractor and the cost thereof shall be deemed to be included in the unit rate quoted against this item.(iv) Rates are deemed to be inclusive of checking and make functional of WTI, OTI, Buchholz relay including replacement of unserviceable items fixed in Transformer.(v) All T&P required for disconnection, re-connection, loading and unloading, transportation, etc shall be arranged by contractor and rates for the same shall deemed to be included in rate quoted.(vi) Testing of transformer shall be arranged by the contractor for Type Test & Routine Test which shall be carried out in the presence of Engineer-in-Charge and contractor shall submit test certificates to this effect before processing the RAR for payment.(vii) Actual weight of each coil shall be measured and paid seperately under under relevant items of this Schedule.
2All as per serial item No. 1.00 above here-in-before but transformer capacity 630 KVA ,11 KV graded complete all as specified and directed.
3All as per serial item No. 1.00 above here-in-before but transformer capacity 1500 KVA, 11 KV graded complete all as specified and directed.
4Supply only HV side copper winded coil of existing type size and gauge 11 KV complete with insulation material for transformer upto 1.5 MVA complete all as specified and as directed.
5Supply only LV side copper winded coil of existing type size and gauge 415V complete with insulation material for transformer upto 1.5 MVA complete all as specified and as directed.
6M&L for opening the oil cooled copper wound Transformer capacity 63 KVA to 200 KVA, 11 KV graded from installed position on existing platform/sub station/ two pole/ four pole structure after disconnecting electric supply from HV and LV sides on site necessary repairs like replacement of washers, replacement of sleeves, valves, taps, kerb tapes, cork sheet, refilling of oil, HV bushing, LV bushing and copper terminal stud both end threaded etc after checking and make fully functional the Winding Temparature Indicator (WTI) and Oil Temparature Indicator (OTI) including replacement of unserviceable item (if required) as directed and installing in its original position and making all electric connections with thimble & PG clamps, commissioning including refilling of transformer oil after dehydration with dielectric strength (min 60 KV) and testing complete all as specified and as directed. Notes : (i) Labour component required for the replacement of unserviceable parts shall be deemed to be included in the unit rate quoted against this item. (ii) HV/LV bushes, breather assembly, copper terminal stud both end threaded, Transformer oil, valve, cork sheet shall be measured & paid separately under relevant item. (iii) T&P and minor parts will be arranged by the contractor and the cost thereof shall be deemed to be included in the unit rate quoted against this item.(iv) Container for keeping the transformer oil safe for reuse shall be arranged by contractor.
7All as per serial item No. 6.00 above here-in-before but transformer capacity 630 KVA, 11 KV graded complete all as specified and directed.
8All as per serial item No. 6.00 above here-in-before but transformer capacity 1500 KVA, 11 KV graded complete all as specified and directed.
9Supply only HV bushing assembly with heat resistance gasket including insulation etc with accessories for outdoor / indoor type transformer of capacity 63 KVA to 200 KVA, 11 KV graded complete all as specified and as directed.
10Supply only HV bushing assembly with heat resistance gasket, including insulation etc with accessories for outdoor / indoor type transformer of capacity 630 KVA, 11 KV graded complete all as specified and as directed.
11Supply only HV bushing assembly with heat resistance gasket, including insulation etc with accessories for outdoor / indoor type transformer of capacity 1500 KVA, 11 KV graded complete all as specified and as directed.
12Supply only brass terminal stud, both end threaded complete with double nuts & washers including distance piece both sides and heat resistance gasket suitable for HV outdoor / indoor type transformer of capacity 63 KVA to 200 KVA, 11 KV graded complete all as specified and as directed.
13Supply only brass terminal stud, both end threaded complete with double nuts & washers including distance piece both sides and heat resistance gasket suitable for HV outdoor / indoor type transformer of capacity 630 KVA, 11 KV graded complete all as specified and as directed.
14Supply only brass terminal stud, both end threaded complete with double nuts & washers including distance piece both sides and heat resistance gasket suitable for HV outdoor / indoor type transformer of capacity 1500 KVA, 11 KV graded complete all as specified and as directed.
15Supply only LV bushing assembly with heat resistance gasket, including insulation etc with accessories for outdoor / indoor type transformer of capacity 63 KVA to 200 KVA, 11 KV graded complete all as specified and as directed.
16Supply only LV bushing assembly with heat resistance gasket, including insulation washer etc with accessories for outdoor / indoor type transformer of capacity 630 KVA, 11 KV graded complete all as specified and as directed.
17Supply only LV bushing assembly with heat resistance gasket, including insulation washer etc with accessories for outdoor / indoor type transformer of capacity 1500 KVA, 11 KV graded complete all as specified and as directed.
18Supply only brass terminal stud, both end threaded complete with double nuts & washers including distance piece both sides and heat resistance gasket suitable for LV outdoor / indoor type transformer of capacity 63 KVA to 200 KVA, 11 KV graded complete all as specified and as directed.
19Supply only brass terminal stud, both end threaded complete with double nuts & washers including distance piece both sides and heat resistance gasket suitable for LV outdoor / indoor type transformer of capacity 630 KVA, 11 KV graded complete all as specified and as directed.
20Supply only brass terminal stud, both end threaded complete with double nuts & washers including distance piece both sides and heat resistance gasket suitable for LV outdoor / indoor type transformer of capacity 1500 KVA, 11 KV graded complete all as specified and as directed.
21Supply only cork sheet gasket transformer of capacity 63 KVA to 200 KVA, 11 KV graded complete all as specified and as directed.
22Supply only cork sheet gasket transformer of capacity 630 KVA, 11 KV graded complete all as specified and as directed.
23Supply only cork sheet gasket transformer of capacity 1500 KVA, 11 KV graded complete all as specified and as directed.
24Supply only sundry items viz cover bolts, plug cap screw, washers, insulation materials etc suitable transformer of capacity 63 KVA to 200 KVA, 11 KV graded complete all as specified and as directed.
25Supply only sundry items viz cover bolts, plug cap screw, washers, insulation materials etc suitable transformer of capacity 630 KVA, 11 KV graded complete all as specified and as directed.
26Supply only sundry items viz cover bolts, plug cap screw, washers, insulation materials etc suitable transformer of capacity 1500 KVA, 11 KV graded complete all as specified and as directed.
27Dehydration & filtration of transformer oil through stream line oil filtration plant, extracting the moisture contents and carbon deposits from oil and bringing it to 60 KV (minimum) dielectric strength including carrying out acidity test /dielectric test before and after filtration at site of any installation in Cantt area of any capacity/make of transformer installed on pole mounted, indoor/outdoor type plinth mounted complete all as specified and as directed.Notes: (i) All necessary T&P / testing equipment shall be provided by the contractor at his own cost. No extra payment shall be made to the contractor. (ii) Contractor shall ensure that there shall be no wastage of transformer oil. (iii) Contractor shall ensure that conservator tank is full to its level before starting the dehydration. (iv) New Transformer Oil required for topping up shall be measured and paid for separately under relevant item of this Schedule. (v) Testing of dielectric strength of dehydrated transformer oil of each transformer shall be carried out in the presence of Engineer-in-Charge and cost thereof shall be borne by the contractor.
28Supply and filling in replacement with new mineral grade transformer oil (ISI marked) EHV type conforming to IS-335 of 1993 in transformer duly filtered with filtration plant to obtain high dielectric strength 60 KV (minimum) complete all as specified and as directed.Note : Transformer oil shall be supplied in sealed barrels with test certificate. Cost of barrel shall be deemed to be included in the unit rate quoted by the contractor and empty barrel will be the property of the Department and same shall be deposited to the AGE E/M Store Yard. Nothing extra shall be paid on this account.
29Supply and filling new mineral grade transformer oil (ISI marked) EHV type conforming to IS-335 of 1993 for topping up only in transformer duly filtered with filtration plant to obtain high dielectric strength 60 KV (minimum) complete all as specified and as directed.Note : Transformer oil shall be supplied in sealed barrels with test certificate. Cost of barrel shall be deemed to be included in the unit rate quoted by the contractor and empty barrel will be the property of the Department and same shall be deposited to the AGE E/M Store Yard. Nothing extra shall be paid on this account.
30M&L for cleaning sprinkled transformer oil and all other foreign material and preparation of pained surface of transformer (Exposed external surface only) installed at site of any installation in Kanasar cantt area, capacity 63 KVA to 315 KVA transformer installed on pole mounted, indoor/outdoor plinth mounted, by using coarse cloth/sore brush and painting with one coat of synthetic enamel grey paint with the help of spray gun, including writing SM No./MES No. with paint on black base complete all as specified and as directed.
31Supply and fixing in replacement of breather assembly with silica gel for transformer of capacity 63 KVA to 200 KVA, 11 KV graded complete all as specified and as directed.
32M&L Silica Gel blue in crystal complete all as specified and as directed.
33Supply and fixing in replacement of Temperature gauge/dial thermometer of 0 degree Celcius to 120 degree Celcius for transformer of capacity 63 KVA to 1500 KVA, 11 KV graded complete all as specified and as directed.
34Supply and fixing in replacement of oil level indicator complete all as specified and directed.
35S&F in replacement of Earthing continuity conductor or main earthing lead fixed to wall or batten or recess or buried in ground or drawn in conduit /pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32x6mm galvanized iron strip complete all as specified and directed.
36Supply, installation, testing of advanced maintenance free environment friendly CPRI approved earthing 10 feet long 50 mm dia earth electrode made high tensile low carbon steel circular rods, molecular bonded copper on outer surface (minimum copper bonded thickness 250 micron) with terminal to connect incoming Copper 25 x4mm earthing strips with the equipment/transformer including 02 bags (30 Kg each) of environment friendly backfill compound with ROHS test certificate for each. The remaining space will be filled with soil and top of earth pit covered with high density polymer.Earth pit chamber cover with locking seal as to achieve the desired ohmic value complete all as specified and directed.
37M&L for cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core HT XLPE armoured aluminium conductor cable of size 95 sqmm including dismantling & taking out old unserviceable jointing kit complete all as specified & as directed.
38M&L for cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core HT XLPE armoured aluminium conductor cable of size 150 sqmm including dismantling & taking out old unserviceable jointing kit complete all as specified & as directed.
39M&L for cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core HT XLPE armoured aluminium conductor cable of size 95 sqmm including dismantling & taking out old unserviceable jointing kit complete all as specified & as directed.
40M&L for cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core HT XLPE armoured aluminium conductor cable of size 150 sqmm including dismantling & taking out old unserviceable jointing kit complete all as specified & as directed.
41M&L for cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core HT XLPE armoured aluminium conductor cable of size 95 sqmm including dismantling & taking out old unserviceable jointing kit complete all as specified & as directed.
42M&L for cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core HT XLPE armoured aluminium conductor cable of size 150 sqmm including dismantling & taking out old unserviceable jointing kit complete all as specified & as directed.
43M&L for cable jointing kit for 11 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core HT XLPE armoured aluminium conductor cable of size 95 sqmm including dismantling & taking out old unserviceable jointing kit complete all as specified & as directed.
44Supply only megger (digital type) insulation and continuity tester upto 5000 volts pressure range complete all as specified and as directed
45Supply and laying in replacement of synthetic Rubber insulated mats 3mm thick for voltage upto 33 KV for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and as directed.
46S&F in replacement of Danger notice plate of 25x20cm size, 1.6mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour for HT 11000 Volts and fixed with suitable MS clamps made out of flat iron 25x5mm, bolts and nuts of approved size, fixed complete all as specified & as directed.
47M&L for cable route indicator made of Jodhpur stone of finished size 120cm x 20cm x 15cm with round top and all finished surfaces duly marked with ‘HT’ lettering of size 6cm x 6cm engraved on two sides of the stone and letters painted with thick synthetic enamel paint of suitable colour including necessary excavation & earthwork complete all as specified and as directed.Notes : (i) These shall be fixed along the route of cable at 50 meter interval & on every turning & cable joint as directed.
48M&L for cleaning, removing dust, pigeon poo and other foreign materials on external surface of transformers, LT Panels etc at various sub station/ E&M installation with required chemical and rubbing by micro amren paper and making surface rust free and aesthetic look cleaning away of all cable trenches for relaying/repositioning of cable in systematic manner complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58320588
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 20 Lakhs
LAST DATE 21-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Maintenance Of Transformer And 11 Kv Network With Allied Works At Mil Stn Kanasar Under Ge(N) Bikaner
Basic Detail
Tender No CA No CWE BKN-Token No 71/2026-2027
Bidding Type Tender
Location
City Bikaner
State Rajasthan
Key Dates
Publish Date 31 Oct 2026
Submission Date 21 Nov 2026
Open Date 28 Nov 2026
Finance
Tender Value 20 Lakhs
Tender Fee 500
EMD 40000
Exemption Available
Document List
0443c3bf-03fc-46a6-9bcc-3153be32ee17.html
BOQ_893589.xls
Tender71.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 31, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 15 days
Nov 28, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 22 days

Tender Documents

Download All (ZIP) ↓
html

0443c3bf-03fc-46a6-9bcc-3153be32ee17.html

xls

BOQ_893589.xls

pdf

Tender71.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender