Tender For special Repair/Replacement Of Ht Cable At Garhwal Scout Area Under Ge 871 Ews.
Tender Value
37.57 Lakhs
Estimated cost
Bid Submission
21 Nov 2026
11 days left
EMD
75200
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Pithoragarh → Uttarakhand
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for special Repair/Replacement Of Ht Cable At Garhwal Scout Area Under Ge 871 Ews.
BOQ
| Sl. No. | Item Description |
| 1 | Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables earthed (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 95 sq mm complete all as specified and as directed. |
| 2 | M&L for Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 mtr in depth for foundation. (Laying of under ground cables) in hard/dense soil and getting out complete all as specified and as directed. |
| 3 | M&L for Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 mtr in depth for foundation. (Laying of under ground cables) in hard rock/PCC road/road and getting out incl making good by using existing material like PCC, inter locking tiles etc complete all as specified and as directed. |
| 4 | M&L for Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed. |
| 5 | M&L for Removing of excavted soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 6 | M&L for Sand filling in trenches for cable protection provided with layer 8cm deep before laying of cable and 15 cm after laying including spreading and leveling watering and well ramming in layer not exceeding 25mm thick complete all as specified and directed. Note: - Thickness of sand cushioning shall be measured after punning. |
| 7 | Supply and laying of Bricks; common burnt clay building bricks, sub-class ‘B’ designation 75 for cable protection cover of size 230mm x 115mm x 75mm laid across the cable (i.e width of brick along the length of cable) for cable protection complete all as specified and directed. |
| 8 | Supplying, erecting and fixing steel tubular swaged poles with cast iron base plate of size 300mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-55 (11.0 metres long) including painting with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30cm wide circular bands with black & white paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in white paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2\\" (inch) wide complete all as specified and directed. Note: Excavation, earth work, PCC in foundation and coping shall be measured and paid separately under relevant item of this schedule. |
| 9 | M&L for PCC 1:3:6 (nominal mix) type C-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete complete all as specified and directed. |
| 10 | M&L for providing concrete for Foundation for steel tubular poles (1:4:8) Type D-2 using 40 mm graded aggregate for foundation of poles including necessary frame work and finishing the exposed surface even and smooth with out using extra cement complete all as specified and directed at site. |
| 11 | M&L for providing concrete for Coping for steel tubular poles (1:2:4) Type B-1 using 20 mm graded aggregate for coping of poles including necessary farm work and finishing the exposed surface even and smooth with out using extra cement complete all as specified and directed at site. |
| 12 | Supply and fix in replacement of light grade Galvanised mild steel pipe 80mm bore complete with all fittings, laid under roads, drain, paths, fixed to poles/ walls with suitable mild steel clamps , bolts , nuts and washers complete all as specified and directed as for cable protection. . |
| 13 | Supply and fix laying & testing of Aerial bunched cable 11000 volt grade stranded and aluminium conductor 3 core x 95 Sqmm,(three phase and one nuetral), + 1 X 70 Sqmm (insulated messenger) , electric power cables (heavy duty) 11000 volts grade with stranded aluminum conductor including all fittings such as anchor clamp,suspension clamps,inline connector,cable protection and dead construction, in cluding taking down unserviceable cable all as per IS , complete all as specified & directed. |
| 14 | S&F in replacement of HT 11 KV bus bar outdoor type weather and vermin proof factory fabricated CPRI approved duly painted with two coat of enamelled paint, pedestal type made out of mild steel sheet 3.15mm thick, factory made, using angle iron 40mm x 40mm x 6mm and 500mm high, front opening double shutter weather proof , rust proof, dust proof with provision of rubber gasket and locking arrangement including HT bush, insulator & bus bar color code - 03 Nos and making connection with suitable size of thimbles, nuts, bolts and washers etc incl necessary earth work, complete all as specified & directed. |
| 15 | Supply and fix in replacement cable end jointing kit for 11 KV grade cable for indoor termination heat shrink type joint complete with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 to 95 Sqmm complete all as specified & directed. |
| 16 | Supply and fix in replacement cable end jointing kit for 11 KV grade cable for outdoor termination heat shrink type joint complete with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 to 95 Sqmm complete all as specified & directed. |
| 17 | M&L for earthing (in repairs) complete with galvanised steel, earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to GI earth strip 32x6mm by means of bolts, nuts, check nuts and washers of galvanised iron/steel all as shown in in electrical plate No 5 on page 19-49 of MES schedule 1991 Part I connected to main switch board /main DBs/ earthing test point Including all necessary excavation and earth work in hard/ dense soil packed layers of common salt and charcoal dust mixed and packed 150 mm thick all-round the GI earth plate, watering pipe 40 mm dia G I medium grade . GI sheet 0.63 mm thick funnel, wire gauge, 75 mm thick RCC cover in PCC 1:2:4 type B1 duly reinforced with MS round bars 8 mm dia @ 150C/C both ways and pit/ chamber in PCC 1:3:6 type C1 with suitable lifting handle to cover, GI protection pipe 40 mm dia light grade up to 7.5m from complete all as specified, indicated on electrical plate No 5 and as directed incl testing on completion complete all as specified and as directed.NOTE: (i) Earth lead beyond 7.5 m from electrode to earth terminal GI pipe light grade 40mmdia for protection against mechanical damage to lead shall be measured separately (ii) On testing after completion if desired earth resistance is not obtained, the earthing will be redone at no extra cost. |
| 18 | M&L for earthing (in repairs) complete with galvanised steel, earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to and including GI wire of size 4 mm upto 7.5 mtr by means of bolts, nuts, check nuts and washers of galvanised iron/steel all as shown in in electrical plate No 3 on page 19-49 of MES schedule 1991 Part I connected to main switch board /main DBs/ earthing test point Including all necessary excavation and earth work in hard/ dense soil packed layers of common salt and charcoal dust mixed and packed 150 mm thick all-round the GI earth plate, watering pipe 40 mm dia G I medium grade . GI sheet 0.63 mm thick funnel, wire gauge, 75 mm thick RCC cover in PCC 1:2:4 type B1 duly reinforced with MS round bars 8 mm dia @ 150C/C both ways and pit/ chamber in PCC 1:3:6 type C1 with suitable lifting handle to cover, GI protection pipe 40 mm dia light grade up to 7.5m from complete all as specified, indicated on electrical plate No 3 and as directed incl testing on completion complete all as specified and as directed.NOTE: (i) Earth lead beyond 7.5 m from electrode to earth terminal GI pipe light grade 40mmdia for protection against mechanical damage to lead shall be measured separately (ii) On testing after completion if desired earth resistance is not obtained, the earthing will be redone at no extra cost. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 31, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 21, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysNov 28, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender