Tender For Repair/Maint Of Siren And Crush Bell And Allied Works In Technical And Domestic, Repair/Maint Of Motorized Door Of Hangers Door Of Hangers Blast Pens And Runway Links, Repair/Maint Of Fire Alarm System, Cleaning Of Bpi Tanks And Allied Wor
Tender Overview
Project Description
Tender for Repair/Maint Of Siren And Crush Bell And Allied Works In Technical And Domestic, Repair/Maint Of Motorized Door Of Hangers Door Of Hangers Blast Pens And Runway Links, Repair/Maint Of Fire Alarm System, Cleaning Of Bpi Tanks And Allied Works In Technical Area At Af Stn Hasimara
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 10-Nov-2026 | CORRIGENDUM TO BOQ | BOQ | 21-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver4.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority:GE (AF) HASIMARA Name of Work : REPAIR/MAINT OF SIREN AND CRUSH BELL AND ALLIED WORKS IN TECHNICAL AND DOMESTIC, REPAIR/MAINT OF MOTORIZED DOOR OF HANGERS DOOR OF HANGERS BLAST PENS AND RUNWAY LINKS, REPAIR/MAINT OF FIRE ALARM SYSTEM, CLEANING OF BPI TANKS AND ALLIED WORKS IN TECHNICAL AREA AT AF STN HASIMARA Contract No: GE/HAS/ /2026-27 Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE 'A' (BoQ)(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of Item Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Servicing and repair of electronic type single/double tone siren AC, 220/415 volts of range not less than 1 to 3 KM including control box with control wiring from junction box to siren with suitable size copper/aluminium conductor cable as per manufacturer's instruction, complete all as specified and directed. |
| 3 | S&F in repair LED based traffic signal 'Go' or 'No Go' (bicolour) light of size 300mm dia 230 V AC, 50 Hz and having polycarbonate body suitable for extreme condition including fixing to poles with clamps of suitable size, complete all as specified and directed. |
| 4 | Servicing and repair of LED based traffic signal 'Go' or 'No Go' (bicolour) light of size 300mm dia 230 V AC, 50 Hz and having polycarbonate body suitable for extreme condition including replacement of mosfet and PCB card with new one, complete all as specified and directed. |
| 5 | S&F in repair transformer of traffic light (red and green signal traffic light) for extreme condition including refixing in traffic light fitting with suitable size clamps, complete all as specified and directed. |
| 6 | Supply and laying or fixing or passing through pipe PVC insulated and PVC sheathed with electolytic grade annealed copper conductor suitable upto 1100 volts grade, confirming IS 694, size 2.5 Sqmm 7 core including taking down old unserviceable cable, complete all as specified and directed. |
| 7 | M&L for painting electronic type single/double tone siren AC, 220/415 volts of range not less than 1.0 KM including control box by two coats of synthetic enamel paint (1st grade quality) as per existing colour over a coat of red oxide primer after preparation, cleaning and removing dust, rust & dirt, complete all as specified and directed. |
| 8 | S & F “Weatherproof” Thermoplastic Polycarbonate PC - GFS junction box of size 205 x 255 x 112mm IP 66 protection with 7 Nos copper stud type terminal along with multi level knockouts as well as from rear side also for cable entries in different sizes for unprotected outdoor (UV resistance) with internally embedded gasket technology (Polyurethane). Lid fasteners shall have captivetype thermoplastic screws with quarter turn knob option. The box shall be rust proof, water proof, dust proof, U/V Rays protected and 100% Shock proof. The junction box shall fulfill the following standards IEC 60670-22 : Particular requirements for connecting boxes and enclosures. IEC 60695 – 2 – 11 : Glow Wire tested at minimum 960 deg C. Impact Resistant : IK 09 (10 joule) Halogen Free in accordance with IEC 60754-2 .with necessary supporting insulators fixed on hylem sheet ,MS sheet steel fixed inside the bottom portion of box to connect the cable gland complete, entire assembly fixed to 40x5 mm MS structure frame 600mm height grouted on PCC base including necessary earth work, complete all as specified and directed. Note (i) Earth work shall deemed to be included in unit quoted rate (ii) PCC base and MS structure work shall be measured and paid seperately against respective items. |
| 9 | M&L for compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases,splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc. Fe-410-W (Gde-E-250), complete all as specified and as directed. |
| 10 | M&L for PCC (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in coping of poles, etc. including necessary formwork, complete all as specified and directed. |
| 11 | Dismantling and taking up unserviceable electric induction motors of capacity 3/5 HP from foundations after disconnecting electric connections and transportation from site to work shop for carrying out repairs/rewinding of motors, as required, incluidng re-fixing in position, connecting and testing, complete all as specified and directed. |
| 12 | S&F terminal connector for motors of capacity 3 to 5 HP, complete all as specified and directed. |
| 13 | S&F aluminium empeller with housing for motors of capacity 3 to 5 HP, complete all as specified and directed. |
| 14 | S&F in repair to squirrel cage induction motor shaft by welding/grinding, polishing to required sizes for motors of the capacity 3/5 HP, complete all as specified and directed. |
| 15 | S&F in repair of ball bearing suitable for capacity 3 to 5 HP, complete all as specified and directed. |
| 16 | S&F in repair 12 Volt 18 Ah sealed maintenace free battery, complete all as specified and directed. |
| 17 | S&F in repair UPS printed circuit board/ UPS control card for 2 KVA to 5 KVA UPS, complete all as specified and directed. |
| 18 | S&F in repair UPS Printed circuit board/ UPS control card for 600/650 VA UPS, complete all as specified and directed |
| 19 | S&F in repair 12 volt DC battery for 600/650 VA UPS, complete all as specified and directed. |
| 20 | S&F in repair UPS of capacity 600/650 VA with input range 140 V - 300 V AC and output 230 V AC and having DC backup of 12 volt, complete all as specified and directed. |
| 21 | S&F in repair roller door controller compatible with input and output voltage 230 volt AC and 50 Hz, complete all as specified and directed. |
| 22 | S&F in repair wireless door remote contol unit for Hangar rolling shutter, complete all as specified and directed. |
| 23 | Supply only battery/cell of 27 Amp and 12 volt for wireless door remote contol unit, complete all as specified and directed. |
| 24 | Servicing of electric operated iron gate by cleaning of path of gate wheel groove with the help of wire brush and air compressor, applying CRC spray on wheel and applying of petroleium jelly on pulley, shaft of the motor and travelling chain for free movement, including reducing size of metal chain, tightening of all connection of wheel, replacement of damaged dead load and other connetced work for automatic / manual operation of gate, complete all as specified and directed. |
| 25 | Servicing/repairing of electric operated MS rolling shutter by cleaning of path of shutter groove with the help of wire brush and air compressor, applying CRC spray on groove and applying of petroleium jelly on shutter groves, shaft of the motor for free movement, including alligment of grear tooth, tightening of all connection, replacement of damaged dead load and other connetced work for automatic / manual operation of Rolling shutter, complete all as specified and directed. |
| 26 | S&F in replacement Lever Type Limit Switch to changeover (NO/NC) contacts of motor of a moving equipment, IP-55, confirming to IS-13947 (Part)-1993, made out of powder coated aluminium dia cast, thermal test current 10 Amps, including connected control wiring from motor starter panels, complete all as specified and directed. |
| 27 | S&F in replacement of PVC cable carrier trolley clamp, suitable for movement on 8/10mm dia steel wire rope, carrage wire 2.5/4 sqmm 4 core, complete all as specified and directed. |
| 28 | S&F in replacement of travelling / control cable, flexible, of size 4 sqmm 4 core, un-armoured, solid copper conductor, PVC innersheathed, complete all as specified and directed. |
| 29 | S&F in replacement of travelling / control cable flexible of size 6sqmm 4 core, un-armoured, solid copper conductor, PVC innersheathed, complete all as specified and directed. |
| 30 | M & L for re-winding of electric motor with super enamelled copper wire, including varnishing, sheathing, complete all as specified and directed |
| 31 | M & L for replacement of push and pull type emergency stop switch, complete all as specified and directed. |
| 32 | M & L for replacement of 3 pole 10 Amp AC contactor with 2 NO & 2 NC with aux contact, complete all as specified and directed. |
| 33 | S&F in replacement forward and reverse push start swtich, complete all as specified and directed. |
| 34 | S&F in replacement of indicator lamp LED, any colour, as per site, including connected control wiring, complete all as specified and directed. |
| 35 | S&F in replacement steel wire rope of dia 8 mm upto 1770 N/mm sq tensile strength, ungalvanised, complete all as specified and directed. |
| 36 | S & F junction box made from SMC/FRP sheet ready made of size 370 x 270 x 210mm with aluminium bus bar of 100 Amp capacity for RYB and half for neutral, made in suitable size, fixed inside the junction box with necessary supporting insulators, fixed on hylem sheet ,MS sheet steel fixed inside the bottom portion of box to connect the cable gland complete, entire assembly fixed to pole /Wall with MS clamp 25 x 5mm and nuts & bolts or inside the copping of pole /Post top including MCB SP 6 Amp 10 KA 240 V - 1 Nos, with suitable size copper lugs for connecting cables from junction box to fittings including taking out the existing, complete all as specified and directed |
| 37 | Dismantling and taking up unserviceable electric motors of capacity 2HP from foundations of door Hangar after disconnecting electric connections and transportation from site to work shop for carrying out repairs / rewinding of motors as required incluidng re-fixing in position and connecting and testing, complete all as specified and directed |
| 38 | S&F terminal connector for motors of capacity 2 HP, complete all as specified and directed |
| 39 | S&F PVC fan blade for motors of capacity 2 HP, complete all as specified and directed |
| 40 | Repairs to squirrel cage induction motor shaft by welding / grinding, polishing to required sizes for motors of capacity 2 HP, complete all as specified and directed |
| 41 | S&F in replacement of ball bearing suitable for capacity 2HP, complete all as specified and directed |
| 42 | M&L for opening and carrying out repair to Gear Mechanism, mounted on shaft of 2HP motor of hangar doors after dismantling the assembly complete for replacement of worn out spares such as Gear Tooth Profile, Gear shaft, sleeves, bushes etc. including filling, turning & polishing works to Gear shaft, as necessiated, reassembling the Gear moving mechanism after repairs and testing, complete all as specified and directed. |
| 43 | S&F in replacement of gear tooth system profile with bushes as per existing at site, suitable for 2HP motor, complete all as specified and directed. |
| 44 | S&F in repair shaft steel of surface door opener with key and bushes suitable for 2 HP motor, complete all as specified and directed. |
| 45 | S&F bearing & bush of surface door opener with key and bushes suitable for 2 HP motor, complete all as specified and directed . |
| 46 | S & F motor coupler sleeve with key of surface door opener of Hangar of capacity 2 HP capacity, complete all as specified and directed. |
| 47 | S&F in replacement MS, joists of motor, bracings, supports, clamps, straps D-clamps, back plates and MS frames fabricated from structural steel sections such as MS channel, angle iron and flats of suitable size etc including nuts, bolts, washers eye hooks, welding, bending cold or hot drilling holes for bolts in any shape or size including applying two coats of synthetic enamel paint over a coat of red oxide primer after preparation of steel surfaces, complete all as specified and directed. |
| 48 | M & L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm buried directly in ground vertically to depth not less than 2.25 mtr below ground level with top edge earth plate at a depth not less than 1.5 mtr below ground level, connected to earth lead of 32 x 6mm dia by means of nuts, bolts, check nuts & washers made of galvanised iron protection pipe light grade of 20mm dia and watering pipe medium grade of 15 mm dia and filled alternate layer of charcoal or coke and salt , watering funnel with wire mesh, earth pit chamber and cover CI frame PCC (1:3:6) type C-2 all as shown in electrical plate No 3 of SSR Part I of 2009 connected to earthing test point or as directed by Engr-in-charge all specified and indicated including necessary excavation and earth work in hard / dense soil, complete all as specified and directed. |
| 49 | Attending of breakdown in Fire Fighting System consisting of a team of one engineer, one electrician and two helper in technical area, detection nature of defects including carry out minor repairs, repair of water leakage from gland and hydrant system, loose connection of fire fighting pumps, including cleaning the system properly replacement of copper wire of required size to make the machine/equipment functional, opening of switch board / panel board and refixing the same after necessary repair including testing on completion, all as specified and directed.Notes: - (a) The unit rate quoted shall deemed to be included the elements of labour only for rectifying and making the machine functional with minor repair. If replacements of major parts / spares required to make the equipment/machine functional, the cost of labour and material for the same shall be measured and paid for as \\" S & F in repairs/M & L for under relevant items.(b) If breakdown not attended & rectified in same day as received except rewinding of Motor and other major spares as specified, the recovery shall be made for not attending breakdown @ Rs.1000/- per breakdown per day. And after 15 days of nonfunctional of any machine, as specified for any reason due to the contractors, the recovery sall be made @ Rs. 300/- per day till the machine made functional.(c) Cost of new components shall be paid for separately under relevant items as'supply only'. |
| 50 | Comprehensive Service/Repair/maintenance and monthly visit for regular maintenance of the automation of intelligent addressable fire alarm control panel and flowchart based programmable RTU at 101 Sqn (Annex -I & II), ACFTRW, ERS/APU, Parachute Bay & DWR building (total 6 systems) by proving a team of one engineer, one electrician and two helper for each system once a month including checking, testing and cleaning of Loop card, Main board, LCD display, Printer Panel, AC filter,Transformer, Lead acid batteries, Invertor, multisensor, sounder, MCP, Beam Detector, Repeater Panel, Zone monitor Module, UV & IR detector, Remote Response indicator, Loop Isolator, Amplifier and Loud speakers, carrying out normal repairs for trouble free and efficient functioninig of the entire fire alarm system including cleaning the system properly and testing on completion, all as specified and directed.Note:- Cost of new components shall be paid for separately under relevant items as'supply only'. |
| 51 | Dismantling, Servicing of all multisensor detector with heat and smoke combination photoelectric as per exact locations as per manufacturer's instructions and testing for exact locations of fault including cleaning through air blower then reinstalling with a gap of every six month till completion of the contract, complete all as specified and directed. |
| 52 | Servicing and testing of beam detector and its transmitter and receiver alignment with testing kit as per speicified guideline in tender particular specifications once in every month till completion of the contract, complete all as specified and directed. |
| 53 | Servicing and testing of UV & IR flame detector and its alignment to detect flame with Testing Kit as per speicified guideline in tender particular specifications once in every month till completion of the contract, complete all as specified and directed. |
| 54 | Supply and Fixing in repair of indoor addressable detectors complying with and type certified to EN-54 Addressable type multisensor detector with heat and smoke combination photoelectric/ optical with base with self built intelligence, complete all as specified and directed. |
| 55 | Supply only of electronically addressable intelligent resettable type manual call point with mounting base complying with EN 54 standard and LPCB approved with the specifications as appended below:- a) Power- 24V, ≤ 0.6 mA (Standby Current) ≤1.8mA (Alarm Current) b) Class A ,c) Initiating Mode- Pressing the action plate manually Resuming Mode-Manually Resumed by a special Key, d) Ingress Protection IP-43 & Material-ABS |
| 56 | Supply only annunciating device Remote response indicator, complete all as specified and directed. |
| 57 | Supply only fire alarm sounder cum strobe electronic type horizontal single stage continous normal operation for atleast 50 minutes with sound level 65db to 120db measured at 1.5 m with sound output variation of +/- 5 dB, 500m range, complete all as specified and directed. |
| 58 | Supply, Install, Testing & Commissioning of Wireless modem suitable for GSM based communication system to be mounted in RTU, enclosure shall be installed at all proposed buildings, complete all as specified and directed. |
| 59 | Supply only 24 V, DC Power Supply Unit of RTU, complete all as specified and directed. |
| 60 | Supply only MCB SP 6 to 32 Amps, 10 KA, 'C' curve, complete all as specified and directed. |
| 61 | Supply only Relay card 8 relay 1 c/o for RTU panel, complete all as specified and directed. |
| 62 | Supply only Isolation transformer 300 VA for RTU panel, complete all as specified and directed. |
| 63 | Supply only two core copper conductor of size 1.5sqmm, FRLS flexible shielded cable, complete all as specified and as directed. |
| 64 | Supply only sealed lead acid SFM battery 12 volt, 7 AH for RTU panel, complete all as specified and directed. |
| 65 | M & L for draining of existing underground BPI tank and cleaning of sludge of BPI tanks of capacity 35 KL including replacement of filter and other accessories and following work services :- (a) Scraping inner surface of the tank with brushes taking out complete waste diesel /kerosene or any other foreign material & replacement of un serviceable nuts bolts washers of reqd size. (b) Epicoating of the tank to be carried out by using light coloured epoxy-phenolic resin free from zinc, cadmium and copper alloys minimum one coat to be done. (c) After recoating the tank is to be filled with soft water mixed with the accurate ratio of underground tank inhibitor/anti corrosive agent remidol-4000 in the ratio of 1 Ltr remidol 4000/1000Ltr of water for preservance upto 8 hrs.(d) Cleaning of surrounding area of BPI tank carefully and filling of sand above tank completely.Note : Cost of pumping of DHPP(N) and filling of sand shall be measured and paid seperately. |
| 66 | Dismantling of main cover and taking out diesel from BPI tank which remain in the tank and contractor shall make arrangement and refill it into the tank after cleaning, complete all as specified and directed. |
| 67 | S&F in relacement of gun metal gate valve with iron wheel head, screwed both ends for iron pipes and fixed of size 40mm dia, complete all as specified and directed. |
| 68 | S&F in relacement of gun metal gate valve with iron wheel head, screwed both ends for iron pipes and fixed of size 50mm dia, complete all as specified and directed |
| 69 | S&F in repair 40mm bore GI tubing medium grade, including all connected fittings and accessories etc, complete all as specified and directed |
| 70 | S&F in repair 50mm bore GI tubing medium grade, including all connected fittings and accessories etc, complete all as specified and directed |
| 71 | S&F in repair 40mm dia PVC pipe having sufficient pressure rating for filling pumping of DHPP(N) etc, complete all as specified and directed. |
| 72 | Note: An amount of Rs.41,539.00 on account of Credit Schedule for schedule 'A' part - II shall be deducted from the total amount of BOQ to arrive at the contract sum. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 2 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender