Tender For Repairing And Replacement Of Street Lighting System At Strand Bank Road, Kvv Avenue And Other Places In View Of Safety Under Ward No-7,Br-I,Kmc
Tender Value
2.92 Lakhs
Estimated cost
Bid Submission
14 Nov 2026
9 days left
EMD
6000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kolkata → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repairing And Replacement Of Street Lighting System At Strand Bank Road, Kvv Avenue And Other Places In View Of Safety Under Ward No-7,Br-I,Kmc
BOQ
| Sl. No. | Item Description |
| 1 | SCHEDULE OF RATES FOR EARTHINGINSTALLATIONS.Earthing Installation ... with Pipe Electrode.Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (HOT Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipeprotection (1 Mts. long) to be filled with bitumen partly under the tly above ground level driven to an averagedepth of 3.65 Mts. below the ground level as below:(a)By ISI Medium GI pipe. |
| 2 | SCHEDULE OF RATES FOR EARTHING INSTALLATIONS.Soil Excavation.Excavation of soil FOR installation of Earth Electrode and filling & ramming.FOR Morrum Soil. |
| 3 | SCHEDULE OF RATES FOR OVERHEAD LINE INSTALLATION - REPAIR 13. Providing CC (6:3:1) muffing 450x450x600 mm in size or equivalent size of cylindrical muffing above ground level around thepole base complete with 3 mm thick neatly finished cement plaster all round after dismantling the unserviceable muffing if any incl. fixingonly loop box if necessary (a) Without Loop Box |
| 4 | A N N E X U R E - I Basic Rate of Materials: (All Rates of materials from K-1 to K-14 are excluding VAT) 130. 150mm GI pipe (ISI-Medium) |
| 5 | BUILDING WORKS (F) STRUCTURAL STEEL WORKS, GRILLS, GATES ETC. A. ORIGINAL WORKS 3. Cutting to requisite length or shape departmental R.S. joists,channels, angles, tees, plates etc.(Payment to be made on area of cut surface) |
| 6 | BUILDING WORKS (F) STRUCTURAL STEEL WORKS, GRILLS, GATES ETC. B. REPAIRING 2. Welding in M.S. structural work with gas or electric: (a) Tack weld |
| 7 | SCHEDULE OF RATES FOR OH LINE INSTALLATION (LTDISTRIBUTION).Erection of Poles.Erection of Single Steel tubular pole of length as given below with/without sole plate & Cap etc. in CC foundation (Proportion and dimension indicated below), having 600x600x150 mm thick CC (4:2:1) base block below sole plate/polewith hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented finish and GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work(site including fillingup the excavated earth pit with shifted soil and ramming properlyUpto 9.0 mtr. Size 0.6x0.6x1.70 mts |
| 8 | SINTEX FRP (FIBRE-REINFORCED PLASTIC) JUNCTION BOX FOR LIGHTING - IT FEATURES 4-WAY CABLE ENTRY (2 BOTTOM, 2 TOP) AND HOLDS AN IP66 WEATHER PROTECTION RATING, DIMENSIONS: 300 MM (H) X 200 MM (W) X 125 MM (D) WITH A 4 MM WALL THICKNESS. EQUIPPED WITH A 1100V GRADE TERMINAL BLOCK (4 CONNECTORS SUPPORTING UPTO 16 SQ MM CONDUCTORS) AND INCLUDES 1 MCB. RATED AS FIRE-RETARDANT (CLASS FV-0) AND FLAME-PROOF. DESIGNED FOR WALL MOUNTING WITH A FRONT COVER SECURED BY 4 STAINLESS STEEL FASTENERS .HIGH-VOLTAGE CAPABILITY: SUCCESSFULLY CLEARED THE HIGH-VOLTAGE WITHSTAND TEST AT 2 KV (RMS) FOR 1MINUTE BETWEEN LIVE COMPONENTS AND THE MAINCHASSIS. MATERIAL TESTING COMPLIANCE: FIRERETARDANCY ADHERES TO CLASS FV-0 STANDARDS (UNDER IS:11731 PART-II), ALONGSIDE FLAME-PROOF IIA, T6 TEMPERATURE CLASS VALIDATIONS UNDER STANDARD IS/IEC 60079-0 & 1: 2007 AS PER GEM PORTAL RATE |
| 9 | Fixing only TPN MCBDB in Sheet Steel enclosure (4 to 12 way) on flat iron frame on wall 415V TP/TPN |
| 10 | Outdoor Lighting Installation, Steel Tubular Pole/ M.S Pipe/ G.I. Pipe, Pole CAP etc. Supplying & Fixing of G.I pole cap for suitable size |
| 11 | Supplying Al.conductor PVC insulated and sheathed unarmoredcable (1.1KVgrade, Gloster/Havells/Polycab).10sqmm x 4core |
| 12 | Supply and drawing of 7/14 SWG galvanised stranded wire for drawing unarmored cable (supply of cable is not included in the scope) by catenary system of wiring with 3nos. reel insulator per mtr. and binding with binding wires etc,as reqd. for drawing |
| 13 | Drawing of unarmoured cable of suitable size (supply of cable is not included in the scope)on existing Galvanized stranded wire for centenary system with reel insulators and binding wires. |
| 14 | Erection of Galv. (HOT Dip) Cross arms/ `D... Iron Clamp8).M Supplying & Erection of Galv. `D... iron complete with suitable pole clamp 100mmx114mm porcelain shackle insulator & 19 mm dia Galv.bolts & nuts. incl. painting |
| 15 | SCHEDULE OF RATES FOR OVERHEAD LINE INSTALLATION -REPAIR 6. Replacing Galv. (Hot Dip) MS earth clamp 380x40x6 mm size complete with bolts and nuts etc. as required on pole (as per specification) FOR fastening stay wire incl. painting |
| 16 | A N N E X U R E - I Basic Rate of Materials: (All Rates of materials from K-1 to K-14 are excluding VAT) 145. Galv. Straining screw 12\\"x5/8\\" dia |
| 17 | Supply and Fixing of fuse unit complete with base and bridge on existing Board and necessary connection, for the following range.60 Amp. / 63 Amp., 415 V |
| 18 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand(approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required 3 x 22/0.3 (1.5 sqmm) |
| 19 | SUPPLY, INSTALLATION & COMMISSIONING OF FINDER MAKE, THREE-PHASE, TWO-PORT INDOOR SURGE PROTECTOR PANEL (SPD), 3 PHASE, TWO-PORT INDOOR SURGE PROTECTOR PANEL, IS 16463 (PART 11) : 2016 OR IEC 61643-11 : 2011, MAX. CONTINUOUS OPERATING VOLTAGE 320 V (RMS), INGRESS PROTECTION RATING, IP-20, VOLTAGE PROTECTIONLEVEL UPTO 1.5 KV, PROTECTION CLASSIFICATION CLASS I + CLASS II (TYPE 1 + TYPE 2 COMBINED), WARRANTY PERIOD -MINIMUM 2 YEARS FROM THE DATE OF COMMISSIONING, SCOPE OF WORK SUPPLY, INSTALLATION, TESTING, AND COMMISSIONING AT THE DESIGNATED INDOOR SITE AS PER GEM PORTAL RATE |
| 20 | Sub Total |
| 21 | GST 18% |
| 22 | CESS 1% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 31, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 14, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysNov 14, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓
Disclaimer