Tender For Supply, Installation, Testing & Commissioning Of Open Well Submersible Pumping Unit And Allied Works At Water Supply Scheme Planpora Naina Under M&E (Ut Capex).
Tender Value
4.50 Lakhs
Estimated cost
Bid Submission
11 Nov 2026
7 days left
EMD
9000
Bank guarantee accepted
Document Fee
200
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Pulwama → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Supply, Installation, Testing & Commissioning Of Open Well Submersible Pumping Unit And Allied Works At Water Supply Scheme Planpora Naina Under M&E (Ut Capex).
BOQ
| Sl. No. | Item Description |
| 1 | Supply, Installation, Testing & Commissioning of Non-clog Pumping Unit as per IS 5600 at Raw Water Stage.PUMP: -Type of pump : Non–clog Open well Submersible Vertical Pump• Solid Handling Capacity: 20mm (Minimum)/as specified.• Quality of water: Raw water to be handled • Discharge = 8000 GPH, Head = 20 Mtrs, • Motor Rating = Min 10 HP or as recomended by OEM.MATERIAL OF CONSTRUCTION:• Pump Casing : Cast Iron • Impeller : Stainless Steel• Pump Shaft : Stainless Steel/Chrome Steel • Motor Body : Cast Iron/SS• Sealing : Dual mech. seal The bowl plate shall be provided with name plate depicting all specificationsMotor RPM = 1450• Type : Squirrel Cage 3-Phase Induction Motor• Method of starting: Star – Delta/DOL (as specified).• Frequency : 50Hz + 3%• Voltage : 415 ± 6 %, - 15% volts or as recomended by OEM, 3 phase• Class of insulation: Suitable for above rating.• Sealing : Dual mech. seal. Provided with thermal and overload protectionThe motor shall be made of corrosion resisting materials to resist corrosion under normal conditions and the motor shall have a name plate depicting all specifications.Dual Mechanical Seals (01 No) and Bearings (02 No) for the pumping unit must be provided as spare parts for preventive maintenance by the firm for pumping unit. The motor should be sealed by radial rings to avoid mixing of well water with motor filled water.a) The job includes providing and fitting of interlocking arrangement against any failure of coupling. It must be fabricated out of MS strips of suitable size and length. b) The job includes providing and fitting of appropriate size MS nipple 2 feet long threaded on one end and welded to same size MS flange of thickness (as per Table-17) at other end for column pipe as per site requirement. The threaded portion should be as per size of pumping out let for proper fixing.The job includes providing and fitting of R. I. cloth joints/rubber washers with nuts, bolts and washers for all joints of column pipe. The job also includes lowering of pumping unit in the dugwell then proper testing and commissioning of pumping unit on full load at site. Note: Test certificate having the Serial No. of the Pumping Unit along with the performance curve in duplicate from the Manufacturer must be produced on delivery of the item and pumping unit is to be approved from the concerned Sub Divisional office before procuring.Preferred make: KSB/Kirloskar/M&P/Wilo/Darling |
| 2 | Supply, installation, testing and commissioning of Horizontal pumping unit as per IS 1520 with following specification:-Pump:-1.Type :- Horizontal split casing /Multi stage Discharge = 8000 GPH Head = 50-60 MtrsMaterial of construction1. Impeller:- Stainless steel/Bronze/ chrome steel 2. Pump Shaft:- Stainless steel/Chrome Steel3. Pump casing:- Cast Iron 4. Motor RPM:- 29005. Type of water to be handled:- Clear Water 6. Efficiency:- Not Less than 50%The pump shall confirm to IS-1520 code MOTOR :- Rating:- Suitable for above parameters but not less than 15 HPA) Type :- Horizontal squirrel cage Induction TypeB) No. of phases:- 3 phase 415 V+10%,50 Hz, AC supplyC) Winding:- Copper wound squirrel cageD) Type of enclosure:- SPDP/TEFCE) Method of cooling:- Air cooled with fan mountedF) Method of Starting: star deltaG) Efficiency:- Not Less than 90%H) RPM:- 2900The pump-motor should be mounted on a common base frame fabricated out of M.S channel of suitable size and duly fitted with T- type foundation bolts /nuts and washers to make the pumping unit vibration free. The pump and motor should be coupled through suitable coupling. The coupling faces checked for both angular and axial alignment with the help of tapered gauges/feeler gauges or dial indicator. Job includes testing and commissioning of pumping unit on full load at site.Note: Test certificate having the Serial No. of the Pumping Unit along with the performance curve in duplicate from the Manufacturer must be produced on delivery of the item and pumping unit is to be approved from the concerned Sub Divisional office before procuring.Preferred make: KSB/Kirloskar/M&P/Wilo/Darling |
| 3 | Providing and fitting of 3-Core flat submersible copper cable conforming to IS: 694 (Part 1st) – 1964 & IS: 694 (Part 2nd) - 1964 for Submersible Pumping Unit and other electrical Equipment. The cable connections terminal shall be fitted with copper thimbles of required size. The main specification of the cable is given below:Size: 16 Sqmm(Preferred Makes: L&K, Havells, Finolex, Polycab) |
| 4 | Supply, Installation, Testing & Commissioning of FASD Motor Starter with following specifications:Working Principal = Star DeltaRating = 30 HPPower Specs = 3 phase, 415±10% v, 50±3% Hz Relay Range = 30-50 AProtection = Under Voltage/Over Voltage/Single Phase/Phase Reversal/Over Current(Preferred Makes: L&K, Havells, Schneider) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 31, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 11, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysNov 12, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender