Housing Urban and Rular Development Local Bodies Closing in 0 days TDR #58314629

Tender For Work Of Laying Sewer Lines, Flushing Lines And Water Supply Lines Along The 18.00 M And 30.00 M Wide Roads In Anand Kashi Township, Varanasi.

Issued by Local Bodies · Varanasi, Uttar Pradesh
Tender Value
5.02 Crore
Estimated cost
Bid Submission
20 Nov 2026
0 days left
EMD
10.05 Lakhs
Bank guarantee accepted
Document Fee
10900
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Varanasi → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Work Of Laying Sewer Lines, Flushing Lines And Water Supply Lines Along The 18.00 M And 30.00 M Wide Roads In Anand Kashi Township, Varanasi.

BOQ

Name of Work:- Work of Laying Sewer Lines, Flushing Lines and Water Supply Lines along the 18.00 m and 30.00 m Wide Roads in Anand Kashi Township, Varanasi.
Sl. No. Item Description
1EXTERNAL STORM WATER SYSTEM (18M. WIDE ROAD)
2COST OF EXTERNAL DRAINAGE WORKS Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, for all depth, inlcuding getting out the excavted materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc, stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m:Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
3Pipes, cables etc. exceeding 300 mm dia. but not exceeding 600 mm dia
4Open timbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered)Depth not exceeding 1.5 meter
5Depth 1.5 to 3.00 meter
6Depth exceeding 3 m but not exceeding 4.5 m
7Providing, supplying, laying, jointing, testing and commissioning of HDPE Double Wall Corrugated (DWC) Pipe of Ring Stiffness Class SN-8, conforming to IS 16098 (Part 2), complete with push-fit socket and elastomeric rubber ring joints, laid true to line and level on a 100 mm thick Plain Cement Concrete (PCC) bed in cement concrete 1:5:10 (1 Cement : 5 Coarse Sand : 10 Graded Stone Aggregate, 40 mm nominal size), including excavation of trenches, dressing and preparation of bed, providing PCC bedding, lowering, laying and jointing of pipes, testing for leakage, backfilling in layers with selected excavated earth, compaction, disposal of surplus excavated material within the specified lead, restoration of the surface to its original condition, and all labour, materials, tools, plant, equipment and incidental works complete as per approved drawings, technical specifications and the directions of the Engineer-in-Charge.150mm diameter
8200mm diameter
9250mm diameter
10300 mm diameter
11Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design150 mm. dia.
12200 mm. dia.
13250 mm. dia.
14300 mm. dia.
15Constructing brick masonry circular type manhole 0.91m internal dia at bottom and 0.56m dia at top in cement 1:4 (1 Cement : 4 Course Sand), inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 course sand : 6 graded stone aggregate 40mm nominal size,) and making necessary channel in cement concrete 1:2:4 ( 1 cement : 2 course sand: 4 graded stone aggregate 20 mm nominal size) finised with floating coat of neat cement, all complete as per standard design:0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete.(Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) :With common burnt clay FPS (non modular) bricks of class designation 75
16Extra for depth for manholes: Extra depth for circular type manhole 0.91m internal dia (at bottom) beyond 0.91 m to 1.67 m
17Constructing brick masonary circular manhole 1.22 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand) inside cement plaster 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 40mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, all complete as per standard design:1.68 m deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate 20mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately):With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
18Extra depth for circular type manhole 1.22m internal dia (at bottom) beyond 1.68m to 2.29mWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5
19Constructing brick masonry circular manhole 1.52 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :2.30 m deep with SFRC Cover and frame (heavy duty HD- 20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
20Extra depth for circular type manhole 1.52 m internal dia (at bottom)beyond 2.30 m :
21Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 in width as well as 10 sqm on plan) inlcuding getting out and disposal of excavated earth lead uptp 50 m and lift uptp 1.5 m, as directed byt Enineer-in-charge.All kinds of soil
22EXTERNAL SEWERAGE SYSTEM STP
23COST OF EXTERNAL SEWERAGE WORKS Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, for all depth, inlcuding getting out the excavted materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc, stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m:Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
24Pipes, cables etc. exceeding 300 mm dia. but not exceeding 600 mm dia
25Open timbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered)Depth not exceeding 1.5 meter
26Depth 1.5 to 3.00 meter
27Depth exceeding 3 m but not exceeding 4.5 m
28Providing, supplying, laying, jointing, testing and commissioning of HDPE Double Wall Corrugated (DWC) Pipe of Ring Stiffness Class SN-8, conforming to IS 16098 (Part 2), complete with push-fit socket and elastomeric rubber ring joints, laid true to line and level on a 100 mm thick Plain Cement Concrete (PCC) bed in cement concrete 1:5:10 (1 Cement : 5 Coarse Sand : 10 Graded Stone Aggregate, 40 mm nominal size), including excavation of trenches, dressing and preparation of bed, providing PCC bedding, lowering, laying and jointing of pipes, testing for leakage, backfilling in layers with selected excavated earth, compaction, disposal of surplus excavated material within the specified lead, restoration of the surface to its original condition, and all labour, materials, tools, plant, equipment and incidental works complete as per approved drawings, technical specifications and the directions of the Engineer-in-Charge.200mm diameter
29250mm diameter
30450mm diameter
31600mm diameter
32Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design200 mm. dia.
33250 mm. dia.
34450 mm dia
35600 mm dia
36Extra for depth for manholes: Extra depth for circular type manhole 0.91m internal dia (at bottom) beyond 0.91 m to 1.67 m
37Constructing brick masonary circular manhole 1.22 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand) inside cement plaster 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 40mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, all complete as per standard design:1.68 m deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate 20mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately):With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
38Extra depth for circular type manhole 1.22m internal dia (at bottom) beyond 1.68m to 2.29mWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5
39Constructing brick masonry circular manhole 1.52 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :2.30 m deep with SFRC Cover and frame (heavy duty HD- 20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
40Extra depth for circular type manhole 1.52 m internal dia (at bottom)beyond 2.30 m :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
41Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 in width as well as 10 sqm on plan) inlcuding getting out and disposal of excavated earth lead uptp 50 m and lift uptp 1.5 m, as directed byt Enineer-in-charge.All kinds of soil
42FLUSHING & IRRIGATION WATER SUPPLY SYSTEM
43External Flushing & Irrigation Water Supply Providing and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS : 8329 :100 mm dia Ductile Iron Class K-9 pipes
44150 mm dia Ductile Iron Class K-9 pipes
45Providing & Fixing C.I.sluice valve(with cap) complete with bolts,nuts,rubber insertions etc.(the tail pieces if required will be paid separately)80 mm dia
46100 mm dia
47150 mm dia
48Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore
4932 mm nominal bore
5080 mm nominal bore
51Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. (Cold Water Supply System.)25 mm nominal dia Pipes
5232 mm nominal dia Pipes
5380 mm nominal dia Pipes
54Providing and fixing brass ferrule with CI mounth cover including boring and tapping the main25 mm nominal bore
55Providing and fixing water meter flange end woltman water meter class A type. 80 MM DIA
56Providing and fixing motorized butterfly valves the valve should be able to oprate with hot/cold water medium between 20---120 degree working temperature, the nominal pressure of the valve should be PN 16, leakage rate through the valve disc should be Rate-A Bubble tight to EN1266-1 with integrated flange sealing should ensure positive connection of the valve body seat ring and valve disc and provide a complete isolation of the media from the body. The disc casting should be precision machined and should give a smooth and close disc-to-seat relationship. The stem bearing should comprise of non corrosive PTFE bushing to completely isolate the valve seat from the body, resulting in increase control of the valve disc, lower valve seating torque and longer valve life. The disc should be stainless steel to offer a good corrosion resistance, superior resistance to a broad range of chemical enviorments as well as very low co-efficient of friction and excellent resistance to impact and ultra-violet radiation. For temperatures and rust proof operation the valve disc should be stainless steel material. 150 MM DIA Basic Rate
57FRESH WATER SUPPLY SYSTEM
58External Fresh Water Supply Providing and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS : 8329 :100 mm dia Ductile Iron Class K-9 pipes
59150 mm dia Ductile Iron Class K-9 pipes
60Providing & Fixing C.I.sluice valve(with cap) complete with bolts,nuts,rubber insertions etc.(the tail pieces if required will be paid separately)80 mm dia
61100 mm dia
62150 mm dia
63Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore
6432 mm nominal bore
6580 mm nominal bore
66Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. (Cold Water Supply System.)25 mm nominal dia Pipes
6732 mm nominal dia Pipes
6880 mm nominal dia Pipes
69Providing and fixing brass ferrule with CI mounth cover including boring and tapping the main25 mm nominal bore
70Providing and fixing water meter flange end woltman water meter class A type. 80 MM DIA
71Providing and fixing motorized butterfly valves the valve should be able to oprate with hot/cold water medium between 20---120 degree working temperature, the nominal pressure of the valve should be PN 16, leakage rate through the valve disc should be Rate-A Bubble tight to EN1266-1 with integrated flange sealing should ensure positive connection of the valve body seat ring and valve disc and provide a complete isolation of the media from the body. The disc casting should be precision machined and should give a smooth and close disc-to-seat relationship. The stem bearing should comprise of non corrosive PTFE bushing to completely isolate the valve seat from the body, resulting in increase control of the valve disc, lower valve seating torque and longer valve life. The disc should be stainless steel to offer a good corrosion resistance, superior resistance to a broad range of chemical enviorments as well as very low co-efficient of friction and excellent resistance to impact and ultra-violet radiation. For temperatures and rust proof operation the valve disc should be stainless steel material. 150 MM DIA Basic Rate
72EXTERNAL STORM WATER SYSTEM (30M. WIDE ROAD)
73Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, for all depth, inlcuding getting out the excavted materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc, stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m:Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
74Open timbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered)Depth not exceeding 1.5 meter
75Providing, supplying, laying, jointing, testing and commissioning of HDPE Double Wall Corrugated (DWC) Pipe of Ring Stiffness Class SN-8, conforming to IS 16098 (Part 2), complete with push-fit socket and elastomeric rubber ring joints, laid true to line and level on a 100 mm thick Plain Cement Concrete (PCC) bed in cement concrete 1:5:10 (1 Cement : 5 Coarse Sand : 10 Graded Stone Aggregate, 40 mm nominal size), including excavation of trenches, dressing and preparation of bed, providing PCC bedding, lowering, laying and jointing of pipes, testing for leakage, backfilling in layers with selected excavated earth, compaction, disposal of surplus excavated material within the specified lead, restoration of the surface to its original condition, and all labour, materials, tools, plant, equipment and incidental works complete as per approved drawings, technical specifications and the directions of the Engineer-in-Charge.150mm diameter
76200mm diameter
77250mm diameter
78300 mm diameter
79Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design150 mm. dia.
80200 mm. dia.
81250 mm. dia.
82300 mm. dia.
83Extra for depth for manholes: Extra depth for circular type manhole 0.91m internal dia (at bottom) beyond 0.91 m to 1.67 m
84Constructing brick masonary circular manhole 1.22 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand) inside cement plaster 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 40mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, all complete as per standard design:1.68 m deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate 20mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately):With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
85Extra depth for circular type manhole 1.22m internal dia (at bottom) beyond 1.68m to 2.29mWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5
86Constructing brick masonry circular manhole 1.52 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :2.30 m deep with SFRC Cover and frame (heavy duty HD- 20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
87Extra depth for circular type manhole 1.52 m internal dia (at bottom)beyond 2.30 m :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
88Providing orange colour safety foot rests of minimum 6 mm thick plastic encapsulated as per IS:10910 on 12 mm dia steel bar conforming to IS:1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm thread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
89Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 in width as well as 10 sqm on plan) inlcuding getting out and disposal of excavated earth lead uptp 50 m and lift uptp 1.5 m, as directed byt Enineer-in-charge.
90EXTERNAL SEWERAGE SYSTEM (30M. WIDE ROAD)
91Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, for all depth, inlcuding getting out the excavted materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc, stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m.Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
92Pipes, cables etc. exceeding 300 mm dia. but not exceeding 600 mm dia
93Open timbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered)Depth not exceeding 1.5 meter
94Depth 1.5 to 3.00 meter
95Depth exceeding 3 m but not exceeding 4.5 m
96Providing, supplying, laying, jointing, testing and commissioning of HDPE Double Wall Corrugated (DWC) Pipe of Ring Stiffness Class SN-8, conforming to IS 16098 (Part 2), complete with push-fit socket and elastomeric rubber ring joints, laid true to line and level on a 100 mm thick Plain Cement Concrete (PCC) bed in cement concrete 1:5:10 (1 Cement : 5 Coarse Sand : 10 Graded Stone Aggregate, 40 mm nominal size), including excavation of trenches, dressing and preparation of bed, providing PCC bedding, lowering, laying and jointing of pipes, testing for leakage, backfilling in layers with selected excavated earth, compaction, disposal of surplus excavated material within the specified lead, restoration of the surface to its original condition, and all labour, materials, tools, plant, equipment and incidental works complete as per approved drawings, technical specifications and the directions of the Engineer-in-Charge.200mm diameter
97250mm diameter
98300 mm diameter
99Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design200 mm. dia.
100250 mm. dia.
101300 mm. dia.
102Extra for depth for manholes: Extra depth for circular type manhole 0.91m internal dia (at bottom) beyond 0.91 m to 1.67 m
103Constructing brick masonary circular manhole 1.22 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand) inside cement plaster 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 40mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, all complete as per standard design:1.68 m deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate 20mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately):With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
104Extra depth for circular type manhole 1.22m internal dia (at bottom) beyond 1.68m to 2.29mWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5
105Constructing brick masonry circular manhole 1.52 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :2.30 m deep with SFRC Cover and frame (heavy duty HD- 20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
106Extra depth for circular type manhole 1.52 m internal dia (at bottom)beyond 2.30 m :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
107Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 in width as well as 10 sqm on plan) inlcuding getting out and disposal of excavated earth lead uptp 50 m and lift uptp 1.5 m, as directed byt Enineer-in-charge.
108FLUSHING & IRRIGATION WATER SUPPLY SYSTEM (30M. WIDE ROAD)
109Providing and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS : 8329 :100 mm dia Ductile Iron Class K-9 pipes
110150 mm dia Ductile Iron Class K-9 pipes
111Providing & Fixing C.I.sluice valve(with cap) complete with bolts,nuts,rubber insertions etc.(the tail pieces if required will be paid separately)100 mm dia
112150 mm dia
113Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) 25 mm nominal bore
11432 mm nominal bore
11565 mm nominal bore
11680 mm nominal bore
117Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. (Cold Water Supply System.)25 mm nominal dia Pipes
11832 mm nominal dia Pipes
11965 mm nominal dia Pipes
12080 mm nominal dia Pipes
121Providing and fixing brass ferrule with CI mounth cover including boring and tapping the main25 mm nominal bore
122Providing and fixing water meter flange end woltman water meter class A type. 80 MM DIA
123Providing and fixing motorized butterfly valves the valve should be able to oprate with hot/cold water medium between 20---120 degree working temperature, the nominal pressure of the valve should be PN 16, leakage rate through the valve disc should be Rate-A Bubble tight to EN1266-1 with integrated flange sealing should ensure positive connection of the valve body seat ring and valve disc and provide a complete isolation of the media from the body. The disc casting should be precision machined and should give a smooth and close disc-to-seat relationship. The stem bearing should comprise of non corrosive PTFE bushing to completely isolate the valve seat from the body, resulting in increase control of the valve disc, lower valve seating torque and longer valve life. The disc should be stainless steel to offer a good corrosion resistance, superior resistance to a broad range of chemical enviorments as well as very low co-efficient of friction and excellent resistance to impact and ultra-violet radiation. For temperatures and rust proof operation the valve disc should be stainless steel material. 150 MM DIA Basic Rate
124FRESH WATER SUPPLY SYSTEM (30M. WIDE ROAD)
125External Fresh Water Supply Providing and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS : 8329 :100 mm dia Ductile Iron Class K-9 pipes
126150 mm dia Ductile Iron Class K-9 pipes
127Providing & Fixing C.I.sluice valve(with cap) complete with bolts,nuts,rubber insertions etc.(the tail pieces if required will be paid separately)100 mm dia
128150 mm dia
129Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore
13032 mm nominal bore
13165 mm nominal bore
13280 mm nominal bore
133Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. (Cold Water Supply System.)25 mm nominal dia Pipes
13432 mm nominal dia Pipes
13565 mm nominal dia Pipes
13680 mm nominal dia Pipes
137Providing and fixing brass ferrule with CI mounth cover including boring and tapping the main25 mm nominal bore
138Providing and fixing water meter flange end woltman water meter class A type. 80 MM DIA
139Providing and fixing motorized butterfly valves the valve should be able to oprate with hot/cold water medium between 20---120 degree working temperature, the nominal pressure of the valve should be PN 16, leakage rate through the valve disc should be Rate-A Bubble tight to EN1266-1 with integrated flange sealing should ensure positive connection of the valve body seat ring and valve disc and provide a complete isolation of the media from the body. The disc casting should be precision machined and should give a smooth and close disc-to-seat relationship. The stem bearing should comprise of non corrosive PTFE bushing to completely isolate the valve seat from the body, resulting in increase control of the valve disc, lower valve seating torque and longer valve life. The disc should be stainless steel to offer a good corrosion resistance, superior resistance to a broad range of chemical enviorments as well as very low co-efficient of friction and excellent resistance to impact and ultra-violet radiation. For temperatures and rust proof operation the valve disc should be stainless steel material. 150 MM DIA Basic Rate Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58314629
AUTHORITY Local Bodies
TENDER VALUE 5.02 Crore
LAST DATE 20-11-2026
Authority
Authority Name Varanasi Development Authority
Work Description Tender for Work Of Laying Sewer Lines, Flushing Lines And Water Supply Lines Along The 18.00 M And 30.00 M Wide Roads In Anand Kashi Township, Varanasi.
Basic Detail
Tender No 1543(3)/VDA/NIRMAN/2026-27
Bidding Type Tender
Location
City Varanasi
State Uttar Pradesh
Key Dates
Publish Date 31 Oct 2026
Submission Date 20 Nov 2026
Open Date 21 Nov 2026
Finance
Tender Value 5.02 Crore
Tender Fee 10900
EMD 10.05 Lakhs
Exemption Not Available
Document List
td.pdf
Tendernotice_1.pdf
8de6a6fb-877c-44c1-add6-d4afc812587d.html
BOQ_2279170.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 31, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 20, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Today
Nov 21, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 1 day

Tender Documents

Download All (ZIP) ↓
pdf

td.pdf

pdf

Tendernotice_1.pdf

html

8de6a6fb-877c-44c1-add6-d4afc812587d.html

xls

BOQ_2279170.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender