Tender For Work Of Laying Sewer Lines, Flushing Lines And Water Supply Lines Along The 18.00 M And 30.00 M Wide Roads In Anand Kashi Township, Varanasi.
Tender Value
5.02 Crore
Estimated cost
Bid Submission
20 Nov 2026
0 days left
EMD
10.05 Lakhs
Bank guarantee accepted
Document Fee
10900
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Varanasi → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Work Of Laying Sewer Lines, Flushing Lines And Water Supply Lines Along The 18.00 M And 30.00 M Wide Roads In Anand Kashi Township, Varanasi.
BOQ
| Sl. No. | Item Description |
| 1 | EXTERNAL STORM WATER SYSTEM (18M. WIDE ROAD) |
| 2 | COST OF EXTERNAL DRAINAGE WORKS Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, for all depth, inlcuding getting out the excavted materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc, stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m:Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia |
| 3 | Pipes, cables etc. exceeding 300 mm dia. but not exceeding 600 mm dia |
| 4 | Open timbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered)Depth not exceeding 1.5 meter |
| 5 | Depth 1.5 to 3.00 meter |
| 6 | Depth exceeding 3 m but not exceeding 4.5 m |
| 7 | Providing, supplying, laying, jointing, testing and commissioning of HDPE Double Wall Corrugated (DWC) Pipe of Ring Stiffness Class SN-8, conforming to IS 16098 (Part 2), complete with push-fit socket and elastomeric rubber ring joints, laid true to line and level on a 100 mm thick Plain Cement Concrete (PCC) bed in cement concrete 1:5:10 (1 Cement : 5 Coarse Sand : 10 Graded Stone Aggregate, 40 mm nominal size), including excavation of trenches, dressing and preparation of bed, providing PCC bedding, lowering, laying and jointing of pipes, testing for leakage, backfilling in layers with selected excavated earth, compaction, disposal of surplus excavated material within the specified lead, restoration of the surface to its original condition, and all labour, materials, tools, plant, equipment and incidental works complete as per approved drawings, technical specifications and the directions of the Engineer-in-Charge.150mm diameter |
| 8 | 200mm diameter |
| 9 | 250mm diameter |
| 10 | 300 mm diameter |
| 11 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design150 mm. dia. |
| 12 | 200 mm. dia. |
| 13 | 250 mm. dia. |
| 14 | 300 mm. dia. |
| 15 | Constructing brick masonry circular type manhole 0.91m internal dia at bottom and 0.56m dia at top in cement 1:4 (1 Cement : 4 Course Sand), inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 course sand : 6 graded stone aggregate 40mm nominal size,) and making necessary channel in cement concrete 1:2:4 ( 1 cement : 2 course sand: 4 graded stone aggregate 20 mm nominal size) finised with floating coat of neat cement, all complete as per standard design:0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete.(Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) :With common burnt clay FPS (non modular) bricks of class designation 75 |
| 16 | Extra for depth for manholes: Extra depth for circular type manhole 0.91m internal dia (at bottom) beyond 0.91 m to 1.67 m |
| 17 | Constructing brick masonary circular manhole 1.22 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand) inside cement plaster 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 40mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, all complete as per standard design:1.68 m deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate 20mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately):With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 18 | Extra depth for circular type manhole 1.22m internal dia (at bottom) beyond 1.68m to 2.29mWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 19 | Constructing brick masonry circular manhole 1.52 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :2.30 m deep with SFRC Cover and frame (heavy duty HD- 20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 20 | Extra depth for circular type manhole 1.52 m internal dia (at bottom)beyond 2.30 m : |
| 21 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 in width as well as 10 sqm on plan) inlcuding getting out and disposal of excavated earth lead uptp 50 m and lift uptp 1.5 m, as directed byt Enineer-in-charge.All kinds of soil |
| 22 | EXTERNAL SEWERAGE SYSTEM STP |
| 23 | COST OF EXTERNAL SEWERAGE WORKS Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, for all depth, inlcuding getting out the excavted materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc, stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m:Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia |
| 24 | Pipes, cables etc. exceeding 300 mm dia. but not exceeding 600 mm dia |
| 25 | Open timbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered)Depth not exceeding 1.5 meter |
| 26 | Depth 1.5 to 3.00 meter |
| 27 | Depth exceeding 3 m but not exceeding 4.5 m |
| 28 | Providing, supplying, laying, jointing, testing and commissioning of HDPE Double Wall Corrugated (DWC) Pipe of Ring Stiffness Class SN-8, conforming to IS 16098 (Part 2), complete with push-fit socket and elastomeric rubber ring joints, laid true to line and level on a 100 mm thick Plain Cement Concrete (PCC) bed in cement concrete 1:5:10 (1 Cement : 5 Coarse Sand : 10 Graded Stone Aggregate, 40 mm nominal size), including excavation of trenches, dressing and preparation of bed, providing PCC bedding, lowering, laying and jointing of pipes, testing for leakage, backfilling in layers with selected excavated earth, compaction, disposal of surplus excavated material within the specified lead, restoration of the surface to its original condition, and all labour, materials, tools, plant, equipment and incidental works complete as per approved drawings, technical specifications and the directions of the Engineer-in-Charge.200mm diameter |
| 29 | 250mm diameter |
| 30 | 450mm diameter |
| 31 | 600mm diameter |
| 32 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design200 mm. dia. |
| 33 | 250 mm. dia. |
| 34 | 450 mm dia |
| 35 | 600 mm dia |
| 36 | Extra for depth for manholes: Extra depth for circular type manhole 0.91m internal dia (at bottom) beyond 0.91 m to 1.67 m |
| 37 | Constructing brick masonary circular manhole 1.22 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand) inside cement plaster 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 40mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, all complete as per standard design:1.68 m deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate 20mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately):With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 38 | Extra depth for circular type manhole 1.22m internal dia (at bottom) beyond 1.68m to 2.29mWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 39 | Constructing brick masonry circular manhole 1.52 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :2.30 m deep with SFRC Cover and frame (heavy duty HD- 20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 40 | Extra depth for circular type manhole 1.52 m internal dia (at bottom)beyond 2.30 m :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 41 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 in width as well as 10 sqm on plan) inlcuding getting out and disposal of excavated earth lead uptp 50 m and lift uptp 1.5 m, as directed byt Enineer-in-charge.All kinds of soil |
| 42 | FLUSHING & IRRIGATION WATER SUPPLY SYSTEM |
| 43 | External Flushing & Irrigation Water Supply Providing and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS : 8329 :100 mm dia Ductile Iron Class K-9 pipes |
| 44 | 150 mm dia Ductile Iron Class K-9 pipes |
| 45 | Providing & Fixing C.I.sluice valve(with cap) complete with bolts,nuts,rubber insertions etc.(the tail pieces if required will be paid separately)80 mm dia |
| 46 | 100 mm dia |
| 47 | 150 mm dia |
| 48 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore |
| 49 | 32 mm nominal bore |
| 50 | 80 mm nominal bore |
| 51 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. (Cold Water Supply System.)25 mm nominal dia Pipes |
| 52 | 32 mm nominal dia Pipes |
| 53 | 80 mm nominal dia Pipes |
| 54 | Providing and fixing brass ferrule with CI mounth cover including boring and tapping the main25 mm nominal bore |
| 55 | Providing and fixing water meter flange end woltman water meter class A type. 80 MM DIA |
| 56 | Providing and fixing motorized butterfly valves the valve should be able to oprate with hot/cold water medium between 20---120 degree working temperature, the nominal pressure of the valve should be PN 16, leakage rate through the valve disc should be Rate-A Bubble tight to EN1266-1 with integrated flange sealing should ensure positive connection of the valve body seat ring and valve disc and provide a complete isolation of the media from the body. The disc casting should be precision machined and should give a smooth and close disc-to-seat relationship. The stem bearing should comprise of non corrosive PTFE bushing to completely isolate the valve seat from the body, resulting in increase control of the valve disc, lower valve seating torque and longer valve life. The disc should be stainless steel to offer a good corrosion resistance, superior resistance to a broad range of chemical enviorments as well as very low co-efficient of friction and excellent resistance to impact and ultra-violet radiation. For temperatures and rust proof operation the valve disc should be stainless steel material. 150 MM DIA Basic Rate |
| 57 | FRESH WATER SUPPLY SYSTEM |
| 58 | External Fresh Water Supply Providing and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS : 8329 :100 mm dia Ductile Iron Class K-9 pipes |
| 59 | 150 mm dia Ductile Iron Class K-9 pipes |
| 60 | Providing & Fixing C.I.sluice valve(with cap) complete with bolts,nuts,rubber insertions etc.(the tail pieces if required will be paid separately)80 mm dia |
| 61 | 100 mm dia |
| 62 | 150 mm dia |
| 63 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore |
| 64 | 32 mm nominal bore |
| 65 | 80 mm nominal bore |
| 66 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. (Cold Water Supply System.)25 mm nominal dia Pipes |
| 67 | 32 mm nominal dia Pipes |
| 68 | 80 mm nominal dia Pipes |
| 69 | Providing and fixing brass ferrule with CI mounth cover including boring and tapping the main25 mm nominal bore |
| 70 | Providing and fixing water meter flange end woltman water meter class A type. 80 MM DIA |
| 71 | Providing and fixing motorized butterfly valves the valve should be able to oprate with hot/cold water medium between 20---120 degree working temperature, the nominal pressure of the valve should be PN 16, leakage rate through the valve disc should be Rate-A Bubble tight to EN1266-1 with integrated flange sealing should ensure positive connection of the valve body seat ring and valve disc and provide a complete isolation of the media from the body. The disc casting should be precision machined and should give a smooth and close disc-to-seat relationship. The stem bearing should comprise of non corrosive PTFE bushing to completely isolate the valve seat from the body, resulting in increase control of the valve disc, lower valve seating torque and longer valve life. The disc should be stainless steel to offer a good corrosion resistance, superior resistance to a broad range of chemical enviorments as well as very low co-efficient of friction and excellent resistance to impact and ultra-violet radiation. For temperatures and rust proof operation the valve disc should be stainless steel material. 150 MM DIA Basic Rate |
| 72 | EXTERNAL STORM WATER SYSTEM (30M. WIDE ROAD) |
| 73 | Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, for all depth, inlcuding getting out the excavted materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc, stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m:Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia |
| 74 | Open timbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered)Depth not exceeding 1.5 meter |
| 75 | Providing, supplying, laying, jointing, testing and commissioning of HDPE Double Wall Corrugated (DWC) Pipe of Ring Stiffness Class SN-8, conforming to IS 16098 (Part 2), complete with push-fit socket and elastomeric rubber ring joints, laid true to line and level on a 100 mm thick Plain Cement Concrete (PCC) bed in cement concrete 1:5:10 (1 Cement : 5 Coarse Sand : 10 Graded Stone Aggregate, 40 mm nominal size), including excavation of trenches, dressing and preparation of bed, providing PCC bedding, lowering, laying and jointing of pipes, testing for leakage, backfilling in layers with selected excavated earth, compaction, disposal of surplus excavated material within the specified lead, restoration of the surface to its original condition, and all labour, materials, tools, plant, equipment and incidental works complete as per approved drawings, technical specifications and the directions of the Engineer-in-Charge.150mm diameter |
| 76 | 200mm diameter |
| 77 | 250mm diameter |
| 78 | 300 mm diameter |
| 79 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design150 mm. dia. |
| 80 | 200 mm. dia. |
| 81 | 250 mm. dia. |
| 82 | 300 mm. dia. |
| 83 | Extra for depth for manholes: Extra depth for circular type manhole 0.91m internal dia (at bottom) beyond 0.91 m to 1.67 m |
| 84 | Constructing brick masonary circular manhole 1.22 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand) inside cement plaster 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 40mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, all complete as per standard design:1.68 m deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate 20mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately):With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 85 | Extra depth for circular type manhole 1.22m internal dia (at bottom) beyond 1.68m to 2.29mWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 86 | Constructing brick masonry circular manhole 1.52 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :2.30 m deep with SFRC Cover and frame (heavy duty HD- 20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 87 | Extra depth for circular type manhole 1.52 m internal dia (at bottom)beyond 2.30 m :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 88 | Providing orange colour safety foot rests of minimum 6 mm thick plastic encapsulated as per IS:10910 on 12 mm dia steel bar conforming to IS:1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm thread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. |
| 89 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 in width as well as 10 sqm on plan) inlcuding getting out and disposal of excavated earth lead uptp 50 m and lift uptp 1.5 m, as directed byt Enineer-in-charge. |
| 90 | EXTERNAL SEWERAGE SYSTEM (30M. WIDE ROAD) |
| 91 | Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, for all depth, inlcuding getting out the excavted materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc, stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m.Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia |
| 92 | Pipes, cables etc. exceeding 300 mm dia. but not exceeding 600 mm dia |
| 93 | Open timbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered)Depth not exceeding 1.5 meter |
| 94 | Depth 1.5 to 3.00 meter |
| 95 | Depth exceeding 3 m but not exceeding 4.5 m |
| 96 | Providing, supplying, laying, jointing, testing and commissioning of HDPE Double Wall Corrugated (DWC) Pipe of Ring Stiffness Class SN-8, conforming to IS 16098 (Part 2), complete with push-fit socket and elastomeric rubber ring joints, laid true to line and level on a 100 mm thick Plain Cement Concrete (PCC) bed in cement concrete 1:5:10 (1 Cement : 5 Coarse Sand : 10 Graded Stone Aggregate, 40 mm nominal size), including excavation of trenches, dressing and preparation of bed, providing PCC bedding, lowering, laying and jointing of pipes, testing for leakage, backfilling in layers with selected excavated earth, compaction, disposal of surplus excavated material within the specified lead, restoration of the surface to its original condition, and all labour, materials, tools, plant, equipment and incidental works complete as per approved drawings, technical specifications and the directions of the Engineer-in-Charge.200mm diameter |
| 97 | 250mm diameter |
| 98 | 300 mm diameter |
| 99 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design200 mm. dia. |
| 100 | 250 mm. dia. |
| 101 | 300 mm. dia. |
| 102 | Extra for depth for manholes: Extra depth for circular type manhole 0.91m internal dia (at bottom) beyond 0.91 m to 1.67 m |
| 103 | Constructing brick masonary circular manhole 1.22 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand) inside cement plaster 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 40mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, all complete as per standard design:1.68 m deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate 20mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately):With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 104 | Extra depth for circular type manhole 1.22m internal dia (at bottom) beyond 1.68m to 2.29mWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 105 | Constructing brick masonry circular manhole 1.52 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :2.30 m deep with SFRC Cover and frame (heavy duty HD- 20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 106 | Extra depth for circular type manhole 1.52 m internal dia (at bottom)beyond 2.30 m :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 107 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 in width as well as 10 sqm on plan) inlcuding getting out and disposal of excavated earth lead uptp 50 m and lift uptp 1.5 m, as directed byt Enineer-in-charge. |
| 108 | FLUSHING & IRRIGATION WATER SUPPLY SYSTEM (30M. WIDE ROAD) |
| 109 | Providing and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS : 8329 :100 mm dia Ductile Iron Class K-9 pipes |
| 110 | 150 mm dia Ductile Iron Class K-9 pipes |
| 111 | Providing & Fixing C.I.sluice valve(with cap) complete with bolts,nuts,rubber insertions etc.(the tail pieces if required will be paid separately)100 mm dia |
| 112 | 150 mm dia |
| 113 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) 25 mm nominal bore |
| 114 | 32 mm nominal bore |
| 115 | 65 mm nominal bore |
| 116 | 80 mm nominal bore |
| 117 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. (Cold Water Supply System.)25 mm nominal dia Pipes |
| 118 | 32 mm nominal dia Pipes |
| 119 | 65 mm nominal dia Pipes |
| 120 | 80 mm nominal dia Pipes |
| 121 | Providing and fixing brass ferrule with CI mounth cover including boring and tapping the main25 mm nominal bore |
| 122 | Providing and fixing water meter flange end woltman water meter class A type. 80 MM DIA |
| 123 | Providing and fixing motorized butterfly valves the valve should be able to oprate with hot/cold water medium between 20---120 degree working temperature, the nominal pressure of the valve should be PN 16, leakage rate through the valve disc should be Rate-A Bubble tight to EN1266-1 with integrated flange sealing should ensure positive connection of the valve body seat ring and valve disc and provide a complete isolation of the media from the body. The disc casting should be precision machined and should give a smooth and close disc-to-seat relationship. The stem bearing should comprise of non corrosive PTFE bushing to completely isolate the valve seat from the body, resulting in increase control of the valve disc, lower valve seating torque and longer valve life. The disc should be stainless steel to offer a good corrosion resistance, superior resistance to a broad range of chemical enviorments as well as very low co-efficient of friction and excellent resistance to impact and ultra-violet radiation. For temperatures and rust proof operation the valve disc should be stainless steel material. 150 MM DIA Basic Rate |
| 124 | FRESH WATER SUPPLY SYSTEM (30M. WIDE ROAD) |
| 125 | External Fresh Water Supply Providing and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS : 8329 :100 mm dia Ductile Iron Class K-9 pipes |
| 126 | 150 mm dia Ductile Iron Class K-9 pipes |
| 127 | Providing & Fixing C.I.sluice valve(with cap) complete with bolts,nuts,rubber insertions etc.(the tail pieces if required will be paid separately)100 mm dia |
| 128 | 150 mm dia |
| 129 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore |
| 130 | 32 mm nominal bore |
| 131 | 65 mm nominal bore |
| 132 | 80 mm nominal bore |
| 133 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. (Cold Water Supply System.)25 mm nominal dia Pipes |
| 134 | 32 mm nominal dia Pipes |
| 135 | 65 mm nominal dia Pipes |
| 136 | 80 mm nominal dia Pipes |
| 137 | Providing and fixing brass ferrule with CI mounth cover including boring and tapping the main25 mm nominal bore |
| 138 | Providing and fixing water meter flange end woltman water meter class A type. 80 MM DIA |
| 139 | Providing and fixing motorized butterfly valves the valve should be able to oprate with hot/cold water medium between 20---120 degree working temperature, the nominal pressure of the valve should be PN 16, leakage rate through the valve disc should be Rate-A Bubble tight to EN1266-1 with integrated flange sealing should ensure positive connection of the valve body seat ring and valve disc and provide a complete isolation of the media from the body. The disc casting should be precision machined and should give a smooth and close disc-to-seat relationship. The stem bearing should comprise of non corrosive PTFE bushing to completely isolate the valve seat from the body, resulting in increase control of the valve disc, lower valve seating torque and longer valve life. The disc should be stainless steel to offer a good corrosion resistance, superior resistance to a broad range of chemical enviorments as well as very low co-efficient of friction and excellent resistance to impact and ultra-violet radiation. For temperatures and rust proof operation the valve disc should be stainless steel material. 150 MM DIA Basic Rate Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 31, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 20, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
TodayNov 21, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 1 dayTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender