Public Administrative Department Local Bodies Closing in 12 days TDR #58307551

Tender For Implementation Of Interlocking Arrangement Between Bus Coupler And Incomers At Ht Panel With Other Related Work At Daspara Bps

Issued by Local Bodies · Kolkata, West Bengal
Tender Value
4.06 Lakhs
Estimated cost
Bid Submission
14 Nov 2026
12 days left
EMD
9000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kolkata → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Implementation Of Interlocking Arrangement Between Bus Coupler And Incomers At Ht Panel With Other Related Work At Daspara Bps

BOQ

Name of Work:- IMPLEMENTATION OF INTERLOCKING ARRANGEMENT BETWEEN BUS COUPLER AND INCOMERS AT HT PANEL WITH OTHER RELATED WORK AT DASPARA BPS
Sl. No. Item Description
1Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection Legrand 6-32 A SP
2SUPPLY AND DELIVERY LOCKABLE LOCAL REMORT SELECTOR SWITCH 660V 25A AC/DC. ( RATE APPROVED BY DG WS 30/01/19 )
3AUXILIARY CONTRACTOR WITH 2NO+2NC FOR LOWER & RASIE . ( SCHEDULE OF RATES (2024-25)(ELECTRICAL & MECHANICAL ) DELHI JOL BOARD , ITEM 8.5.9,PAGE 593 )
4Supply and delivery of Mushroom Actuators (40 mm ...) push to trip, key to release(with plastic front ring) for Emergency Stop Specifications (Make: L&T/ABB/ Schneider/Simence/ GE)
5INDICATING LAMPS. (SCHEDULE OF RATES (2024-25)(ELECTRICAL & MECHANICAL ) DELHI JOL BOARD , ITEM 8.5.26,PAGE 593)
6AUX CONTRACTOR. ( SCHEDULE OF RATES (2024-25)(ELECTRICAL & MECHANICAL ) DELHI JOL BOARD , ITEM 8.4.25,PAGE 591)
7TERMINAL BLOCK 10 AMP . ( SCHEDULE OF RATES (2024-25)(ELECTRICAL & MECHANICAL ) DELHI JOL BOARD , ITEM 7.3.9 ,PAGE 584 )
8MULTIFUNCTIONAL METER . ( SCHEDULE OF RATES (2024-25)(ELECTRICAL & MECHANICAL ) DELHI JOL BOARD , ITEM 7.3.4 ,PAGE 584 )
9COMPLETE PANEL WIRING BY SUPPLY & INSTALLATION OF 1.1 KV GRADE UNSHEATHED COPPER PVC INSULATION WIRE 7/.029 OR 2.5SQ.MM LAYING INSIDE CONTROL CIRCUIT PANEL THROUGH PVC FRONT COVER CABLE TRAY WITH ALL NECESSARY INCLUDING NUMBERING.FERULES, SOCKETING, CRIMPING JOINTS FOR MEASURING INSTRUMENT RELAY, POWER PACK FROM C.T & P.T INCLUDING SUPPLY & FIXING OF 2 NOS.PUSH BUTTON, 16NOS 6-10AMPS HRC FUSE CARTIDGE, BINDING TAPE, NUMBERING FERULES, FLEXIBLE PVC PIPE ETC.THE C.T\\"S SECONDARY CONNECTION SHOULD BE SHORT CIRCUITED & PROPER GROUND EARTH.RECONNECTION OF H.T CABLE TERMINAL JOINT. ( RATE APPROVED BY DG WS 30/01/19 )
10SUPPLYING AND MAKING INDOOR CABLE END TERMINATION WITH HEAT SHRINKABLE JOINTING KIT COMPLETE WITH ALL ACCESSORIES INCLUDING LUGS SUITABLE FOR FOLLOWING SIZE OF 3 CORE , XLPE ALUMINIUM CONDUCTOR CABLE OF 11KV GRADE AS REQUIRED : 3M /RAYCHEM MAKE (A) 240 - 300 SQ. MM. [UNIFIED SCHEDULE OF RATES (ELECTRICAL & MECHANICAL ) IW DEPT , ITEM 5.3C/1,PAGE 104]
11SUPPLY ,DELIVERY & FIXING OD 11KV HEATSHRINK TUBE FOR HEAT SHRINKABLE ANTI TRACKING HIGH VOLTAGE BUSBAR PER METER.RATE ANALYSIS APPROVED BY DG (WS ) ON 31/01/2019
12FITTING FIXING OF CURRENT TRANSFORMER AT HT SWITCH GEAR. RATE ANALYSIS APPROVED BY DG (WS ) ON 31/01/2019
13HIGH VOLTAGE TEST BY 9 KV D.C. (RECTIFIED A.C.)BY PARTY FOR THE FITNESS OF THE SWITCH GEARS FOR FURTHER OPERATION RATE ANALYSIS APPROVED BY DG(WS) ON DATED 31/01/19.
14SERVICING, TESTING, CALIBRATION OF OVERCURRENT, EARTH FAULT C.D.G TYPE RELAY . FAIR RATE APPROVE BY C.E.O. & EX.OFFICIO DG(WS) ON DATED 25/05/19
15SERVICING, TESTING, CALIBRATION OF V.A.A/V.A.X/V.A.G.M/V.A.J/V.A.G TYPE RELAY. FAIR RATE APPROVE BY C.E.O. & EX.OFFICIO DG(WS) ON DATED 25/05/19
16DRAWING OUT THE VACUUM CIRCUIT BREAKER AFTER RACKING DOWN & DISCONNECTING ALL THE CONNECTION OF VCB'S AT 6 KV PANEL .FAIR RATE APPROVE BY C.E.O. & EX.OFFICIO DG(WS) ON DATED 25/05/19
17CLEANING OF THE INSIDE & OUTSIDE OF THE BREAKER ASSEMBLY FAIR RATE APPROVE BY C.E.O. & EX.OFFICIO DG(WS) ON DATED 25/05/19
18CHECKING OF TRIP MECHANISM, TRIP COIL ASSEMBLY, CONNECTION & CONNUTI OF AUXILIARY SWITCH ASSEMBLY FAIR RATE APPROVE BY C.E.O. & EX.OFFICIO DG(WS) ON DATED 25/05/19
19CHECKING OF OPERATION OF BREAKER CHARGING HANDLE, BREAKER TERMINALS, IT'S MOUNTING ARRENGEMENT & MOVEMENT OF IT AND ALSO SUPPORT INSULATOR (BUSBAR) FAIR RATE APPROVE BY C.E.O. & EX.OFFICIO DG(WS) ON DATED 25/05/19
20CHECKING OF CONTINUTY OF PINS OF SECONDARY PLUG & SOCKET ASSEMBLY THROUGH 110V D.C IS SUPPLIED TO BREAKER. FAIR RATE APPROVE BY C.E.O. & EX.OFFICIO DG(WS) ON DATED 25/05/19
21CLEANING CHECKING, TIGHTENING OF ISOLATING EPOXY SPOUTS FOR DRAWOUT VCB (MALE & FEMALE) & BREAKER CHARGING MECHANISM. FAIR RATE APPROVE BY C.E.O. & EX.OFFICIO DG(WS) ON DATED 25/05/19
22CHECKING THE GEAR BOX ASSEMBLY FOR DRAWOUT VCB WITH PROPER GREASING & OILING OF THE PARTS AS REQUIRED FAIR RATE APPROVE BY C.E.O. & EX.OFFICIO DG(WS) ON DATED 25/05/19
23CHECKING , ADJUSTMENT OF PUSH TO TRIP ASSEMBLY, SPRING CHARGE INDICATOR, EARTHING ASSEMBLY WITH FLEX, BOTTLE WITH BOTTLE ASSEMBLY & TENSION OF CONTRACT SPRING, CLOSING SPRING FOR VCB . FAIR RATE APPROVE BY C.E.O. & EX.OFFICIO DG(WS) ON DATED 25/05/19
24CLEANING THE BREAKER CHARGING MOTOR ASSEMBLY AND CHEACKING THR I.R VALUE OF THE MOTOR . FAIR RATE APPROVE BY C.E.O. & EX.OFFICIO DG(WS) ON DATED 25/05/19
25CHECKING THE ADJUSTMENT OF BREAKER LOCKING DEVICE AND OPERATION OF ANYI-PUMPING RELAY ASSEMBLY . FAIR RATE APPROVE BY C.E.O. & EX.OFFICIO DG(WS) ON DATED 25/05/19
26CHECKING, ADJUSTMENT OF AUTOMATIC SHAFT SHUTTER OPERATION OF VCB . FAIR RATE APPROVE BY C.E.O. & EX.OFFICIO DG(WS) ON DATED 25/05/19
27CHECKING, TIGHTENING OF THE LEVEL MECHANISM OF VCB . FAIR RATE APPROVE BY C.E.O. & EX.OFFICIO DG(WS) ON DATED 25/05/19
28CHECKING ELECTRICAL & MECHANICAL 'ON-OFF' OPERATION OF THE VCB IN TEST POSITION. FAIR RATE APPROVE BY C.E.O. & EX.OFFICIO DG(WS) ON DATED 25/05/19
29SUPPLY DELIVERY & FIXING OF POWER PACK 600 WATTS / 800 WATTS 110 V AC TO 110 V DC 3 PHASE FOR PROTECTION SYSTEM, INDICATION SYSTEM, SPRING CHARGING MOTOR , CLOSING , TRIPPING AND INTERLOCKING SYSTEM PROTECTION RELAY, PUSH BOTTOMS, FUSES AND TRANSFORMER. RATE ANALYSIS APPROVED BY DG WS DATED 31.01.2019
30Sub Total
31GST 18%
32CESS 1% Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58307551
AUTHORITY Local Bodies
TENDER VALUE 4.06 Lakhs
LAST DATE 14-11-2026
Authority
Authority Name Kolkata Municipal Corporation
Work Description Tender for Implementation Of Interlocking Arrangement Between Bus Coupler And Incomers At Ht Panel With Other Related Work At Daspara Bps
Basic Detail
Tender No KMC/WS/DSPBPS/26-27/07
Bidding Type Tender
Location
City Kolkata
State West Bengal
Key Dates
Publish Date 31 Oct 2026
Submission Date 14 Nov 2026
Open Date 17 Nov 2026
Finance
Tender Value 4.06 Lakhs
Tender Fee Ref. Documents
EMD 9000
Exemption Not Available
Document List
3f4e287c-a8e5-4dc8-a872-884661c95533.html
BOQ_2566372.xls
Techbid.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 31, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 14, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 12 days
Nov 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 15 days

Tender Documents

Download All (ZIP) ↓
html

3f4e287c-a8e5-4dc8-a872-884661c95533.html

xls

BOQ_2566372.xls

pdf

Techbid.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender