Tender For Repair To Ht Electric Supply System, Ht Cables, Go/Dos, Vcbs, Transformer, Earthing And Connected Items At Rms Dholpur Under Ge Bharatpur
Tender Value
30 Lakhs
Estimated cost
Bid Submission
21 Nov 2026
21 days left
EMD
60000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Bharatpur → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair To Ht Electric Supply System, Ht Cables, Go/Dos, Vcbs, Transformer, Earthing And Connected Items At Rms Dholpur Under Ge Bharatpur
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches n.exc 1.5 metre wide and n.exc 1.5 metre in depth for foundation etc or for shafts, wells, cess pits, manholes, pier holes, laying cables errection of poles / struts/stays etc n.exe 10 Sqm on plan not exceeding 1.5 metre in depth and getting out in soft / loose soil complete all as specified. |
| 2 | All as per item No. 1.00 above but depth exc. 1.5m and n.exc. 3.0m complete all as specified. |
| 3 | Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25cm in soft/loose soil complete all as specified. |
| 4 | Removing of excavated material (soil) to a distance n.exc 50 metre and depositing where directed at a level n.exc 1.50metre above the starting point complete all as specified. |
| 5 | Supplying and laying un-reinforced precast concrete cable cover, class HVP, type 1 with peak, size 300mm x 180mm x 40mm complete all as specified. |
| 6 | M & L Sand cushioning to XLPE under ground cable with screened and washed sand and punning to provide a required cover complete all as specified. |
| 7 | Taking down ACSR over head Aluminium conductor steel reinforced of any size all as specified and directed including stringing/ dismatling through RCC/Steel tubular poles, fixing on insulators, jumpering with aluminium binding wire etc complete all as specified. |
| 8 | Taking out old u/s HT cable from trench/pole/wall/pipe etc as per site complete all as specified. |
| 9 | Supply, laying and commissioning XLPE insulated screened, PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor 11000 volts grade IS-7098 marked, suitable for HT 11 KV (E) System laid in trenches/ ducts/ encased in GI pipe/ fixed to poles including jointing & testing complete all as specified of following cross sectional area :- |
| 10 | (a) 95 Sqmm, 3 core cable complete all as specified. |
| 11 | (b) 120 Sqmm, 3 core cable complete all as specified.Note: Excavation & earth work, Sand cushioning, Bricks, GI tubing & Clamps shall be measured & paid seperately under relevent items of BOQ. |
| 12 | M/L ACSR over head Aluminium conductor steel reinforced of any size all as specified and directed including stringing/ dismatling through RCC/Steel tubular poles, fixing on insulators, jumpering with aluminium binding wire etc complete all as specified. |
| 13 | M&L for PCC (1:3:6) type C1 using 20mm grade stone aggregate in base & foundation of pole including necessary form work complete all as specified. |
| 14 | M&L for PCC 1:2:4 type B1 using 20mm graded stone aggregate in coping of existing/new poles / foundation for poles, struts, posts etc including necessary form work, finished the exposed surfaces fair and even without using extra cement complete all as specified. |
| 15 | Dismantling and taking out old unserviceable HT PCC pole 11 Mtr long complete all as specified. |
| 16 | Supplying, Errecting and fixing in replacement Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11.0 metres long) and providing 3 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2\\" wide, complete all as specified. |
| 17 | Dismantling of cross arms, bracing, support, clamps, nut & bolt of mild steel channel or angle sections etc complete all as specified. |
| 18 | M&L cross arms,bracing ,support clamps and back plate fabricated from structral steel sections including nuts bolts washers welding bending cold or hot drilling holes for bolts in any shape or size as indicated or direcxted and inclusive of one primer coat one under coat and one finishing coat of paint complete all as specified. |
| 19 | Dismantling and taking down existing HT insulators of any type and size complete all as specified. |
| 20 | M&L Disc type insulator, Porcelain, vitreous brown, white or green single disc assembly, 145mm high & 255mm dia ball & socket type, for tension clamps for conductors, working pressure 11000 volts complete all as specified. |
| 21 | M&L pin type, porcelain, vitreous brown, white or green insulator (HT), 150mm height and 150 mm dia, 11000 volts grade including one galvanised MS spindle, two GI washers and one GI nut complete all as specified. |
| 22 | Supply of post insulator single pole with GI post for holding fixed/moving contact assemby including fixing arrangment suitable for Air break gang oprated switch 400 Amps, 11000 volts grade complete all as specified. |
| 23 | M&L for Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and fixed with MS clamps, bolts and nuts of approved size, for HT, 25X20 cm size complete all as specified. |
| 24 | Supply & fixing or laying galvanised steel tubing medium grade (ISI marked) for protection of under ground cable on poles / walls under road crossing etc of 100mm bore sizes including dismantling & taking down existing pipe complete all as specified. |
| 25 | Boring of holes under road, pavement, hard standing by manually boring for laying under ground pipe up 100mm dia complete all as specified.Note :- GI pipe shall be measured and paid in concern Item |
| 26 | M&L for cable end termination, jointing kit, HT 11 KV grade, heat shrinkable, outdoor type complete with jointing material suitable for HT XLPE cable 3 core 11 KV grade incl taking down complete all as specified of following sizes :- |
| 27 | (a) 50 sqmm to 95 Sqmm x 3 core complete all as specified. |
| 28 | (b) 120 sqmm to 185 Sqmm x 3 core complete all as specified. |
| 29 | M&L for cable end termination, jointing kit, HT 11 KV grade,heat shrinkable, indoor type complete with jointing material suitable for HT XLPE cable 3 core 11 KV grade incl taking down complete all as specified of following sizes :- |
| 30 | (a) 50 sqmm to 95 Sqmm x 3 core complete all as specified. |
| 31 | (b) 120 sqmm to 185 Sqmm x 3 core complete all as specified. |
| 32 | M&L for cable, jointing kit, HT 11 KV grade, heat shrinkable, straight through type complete with jointing material suitable for HT XLPE cable 3 core 11 KV grade incl taking down complete all as specified of following sizes :- |
| 33 | (a) 50 sqmm to 95 Sqmm x 3 core complete all as specified. |
| 34 | (b) 120 sqmm to 185 Sqmm x 3 core complete all as specified. |
| 35 | Dismantalling of Air break, gang operated, , outdoor, horizonal mounting type complete all as specified. |
| 36 | Supply, installing, testing and commissioning of Air break, gang operated, triple pole switch, outdoor, horizonal mounting type (ISI marked) , mechanically operated, mounted on 15 insulators with 9 insulator for moving contact of GOD and 6 insulator for fuse unit with operating mechanism worked from ground level with locking arrangments including Godrej pattem 65mm pad locks with two keys, complete suitable for HT 11 KV, 50 Hz AC supply including necessary electric connections complete including taking down old U/S complete all as specified of following rating :- |
| 37 | (a) 200 amp rating complete with fuse carriers and HT fuse elements. |
| 38 | (b) 400 amp rating complete with fuse carriers and HT fuse elements. |
| 39 | Supply and fix lightening arrestor expulsion type complete with all fittings Distribution class discharge capacity 65 KA as per IS 3070 Pt-3 1993 suitable for 11000 volts incl taking down complete all as specified. |
| 40 | Dehydration / filtration of transformer oil existing transformer installed at site with portable plant to improve the dielectric strength 40 to 60 KV during filling after initial filtration including testing of dielectric strength after dehydration at site with testing and completion complete all as specified. |
| 41 | Supply & filling of transformer oil in transformer at site for toping up the level of oil having dielectric strength 60 KV at 2.5 mm gap during filling after initial filtration complete all as specified. |
| 42 | M&L for disconnecting of defective transformer (in door/out door type ) 11 KV/433 volts copper wound from power mains and dismantling the same from 2/4 pole structure/ platform mounted, uploading and transporting by using crane and vehicles the same to authorised workshop and opening the transformer cover, draining out of tranformer oil and keep safely for reuse after filtration, assembling, removing of the burnt parts i.e tape, paper insulating strings etc gently and carefully, washing of the dust, rust and dirt from all partsincluding taking out HT/LT leg coil core tank and cooling tubes, painting the inner side tank by zinc chromate paint, spray painting outside by enemelled smoke gray coloure paint and preparing the same for re-assembling after ovening of core with coil and carrying out required repair and Transporting and re-installation on existing 2/4 pole structure/ platform with neccessary fixing arrangment including connecting up electrically, commissioning and testing all as directed by Engineer-in-Charge and specified of the following capacity complete (HT/LT limb case measured and paid seperately) |
| 43 | (a) 50 KVA to 200 KVA capacity complete all as specified. |
| 44 | (b) 250 KVA to 500 KVA capacity complete all as specified. |
| 45 | Supply only following parts for indoor/out door transformer :- |
| 46 | (a) LT limb copper coil with triple papper coated and varnish insulated complete all as specified. |
| 47 | (b) HT limb copper coil with triple papper coated and varnish insulated complete all as specified. |
| 48 | Supply only HT porecelain bushing complete with brass/tinned copper rod with nuts and gasket set complete for following cap transformer :- |
| 49 | (a) 50 KVA to 250 KVA capacity complete all as specified. |
| 50 | (b) 315 KVA to 500 KVA capacity complete all as specified. |
| 51 | Supply only LT porecelain bushing complete with brass/tinned copper rod with nuts and gasket set complete for following cap transformer :- |
| 52 | (a) 50 KVA to 250 KVA capacity complete all as specified. |
| 53 | (b) 315 KVA to 500 KVA capacity complete all as specified. |
| 54 | Supply only tap changer switch 11 KV complete with rod and gasket for following cap transformer :- |
| 55 | (a) 50 KVA to 250 KVA capacity complete all as specified. |
| 56 | (b) 315 KVA to 500 KVA capacity complete all as specified. |
| 57 | Opening of transformer cover at site for carrying out repairs such as replacment of bushing rods gasket, insulators and minor spare parts etc and re-assembling after carrying out required repair in the transformers complete all as specified. (Note :- Bushing bushing rods shall be measured and paid separately) |
| 58 | Taking out old unservisiable silica gel and fill the new silicate into the breather complete all as specified. |
| 59 | S & F in replacement of neon type indicating lamp (R Y & B) - 01 Set complete all as specified. |
| 60 | M&L for uprooting up to 30 cm deoth grass/weeds/plant by scrapping soil in order to made free ground from all sort of vegetation including supply & spray chemical (glycel 41% Sl or equivalent) for prevention of growth of weed and grass in electrical sub station with spray gun as per the manufacturer's instructions complete all as specified. |
| 61 | Supply and spread and leveling Grading 3 coarse Aggregate in loose filling over the surface of guage 20 mm nominal size in the installation yard complete all as specified. |
| 62 | Supply and spread and leveling Grading 2 coarse Aggregate in loose filling over the surface of guage 40 mm nominal size in the installation yard complete all as specified. |
| 63 | M&L for renewl of copper Earthing complete with copper plate earth electrode 60 cm x 60 cm x 3.15mm, burried directly vertically in ground in a pit of depth not less than 2.25 metres below ground level with the top edge of earth plate at a depth not less than 1.5m below normal ground level connected to and including copper strip 20x3mm dia by means of copper bolts, nuts, check nuts and washers , strip protected by galvanised iron or steel pipe 40mm bore medium grade and connected to continuous earth test point. Watering pipe shall be 20mm bore GI medium grade including excavation and earth work in any type of soil, PCC pit and RCC cover complete all as specified.Notes :- (i) The concrete pit shall be PCC (1: 3:6), 20mm thick precast cover slab of RCC (1:2:4) type B1 using 20mm graded stone aggregate with suitable mild steel handle in lieu of cast iron cover shown in electrical plate No-03 of MES SSR Part-I. Reinforcement in RCC cover shall be 8 mm dia TMT steel bar @ 150mm c/c both ways.(ii) Item includes the cost of 7.5 mtr GI pipe for protection of earth lead/strip. Any varriation in length shall be measured and paid through relevent item of schedule 'A'.(iii) Item includes the cost of 7.5 mtr earth lead strip. Any varriation in length shall be measured and paid through relevent item of schedule 'A'.(iv) Earth eletrode shall be surrounded by adequate quantity of charcoal dust and salt to packedthickness of 150mm on all sides as specified. |
| 64 | Material and labour for replacement of unserviciable existing earthing with bore well earthing with the help of mechanical boring machine of 150 mm dia-30 mtr depth supply and fix 160 mm dia (O.D), UPVC pipe 6 kg/sqcm rating -06 mtr long with the help of suitable size clamp with nut bolt and washer -01 No including charcoal dust ,salt fill in bore well for earth conductivity M&L for covering of bore well with PCC (1:2:4) type B-1 / Brick masonry pit of size 45x45x45 cm complete and give the minimum earth test result below 1 ohm complete all as specified and directed by Engineer-in-charge. Note :- (i) The earth pit shall be refilled by boulders free from vegetable soil.(ii) Earthing shall be tested by contractor in presence of Engr-in-charge. Record shall be maintained.Payment shall be admissible only after satisfactory test results. |
| 65 | Supply & fixing in replacement of GI tubng 50 mm dia medium grade incl necessary fittings for lowering in borewell of depth upto 30 mtr complete all as specified. |
| 66 | Earth continuty conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required by using galvanised iron 32x6 mm strip as earthing lead complete all as specified. |
| 67 | M & L for Repir / Maintenance of drawout type / trolly mounted HT VCB/RMUs 11 KV by cleaning the VCB/RMU by using air blower, tightening of connections / controls , checking of all fuses/,spray painting outside by enemelled smoke gray coloure paint/ sealing of VCB/RMU at bottom, repairing of mechanical parts, oiling / greesing of all moving parts and carrying out following checks for smooth functioning complete all as specified.(a) Visual Inspection.(b) Checking of functional locks, interlocks, signalling devices and auxillery devices. (c) Checking of suitability and correct operations of protections, control instruments and electrical connection of the circuit breaker operating mechnasim. (d) Checking of Tripping Mechanism Operation.(e) Spring Charging Limit Switch Operation.(f) Checking with stand voltage on the auxillary circumstances.(g) Checking of with stand voltage at power frequency. (h) Checking of Breaker ON/OFF Operation manually & electrically.(i) Testing of vacuum Bottle Integrity. (j) Relay Testing.(k) Checking of the resistance of the main circumstances.(l) Verification of wiring.Note:- (i)Work shall be executed by the authorised service center of manufacturer.(ii) Spare part if found deffective will be measured & paid seperatly as supply & fix in repair under respective item of this BOQ |
| 68 | Supply and fix in replacement battery 12V DC 17AH fixed to Metering module of VCB/RMU for auto charging of spring with compatible existing system complete all as specified.Make:- C&S/Crompton/CG/Simens/Schnider |
| 69 | Supply and fix in replacement battery 12V DC 150AH (min 2 years warranty) fixed to inverter of VCB/RMU for continuous supply to relay with compatible existing system complete all as specified.Make:- C&S/Crompton/CG/Simens/Schnider |
| 70 | Supply and fix in repair open push button fixed to SF6 type VCB/RMU of any capacity & connecting complete with compatible existing system complete all as specified.Make:- C&S/Crompton/CG/C Sec |
| 71 | Supply and fix in repair close push button fixed to SF6 type VCB/RMU of any capacity & connecting complete with compatible existing system complete all as specified.Make:- C&S/Crompton/CG/C Sec |
| 72 | Supply and fix in repair VPIS Unit, 9-15 kV fixed to SF6 type VCB/RMU of any capacity & connecting complete with compatible existing system complete all as specified.Make:- C&S/Crompton/CG/C Sec |
| 73 | Supply and fix in repair Trivector meter for VCB/RMU including disconnecting the existing and connecting the new one with necessary wiring complete with compatible existing system complete all as specified.Note : Old meter to be deposit to MES Yard for BER Process |
| 74 | Supply & fix in reapir complete GASKET rubber tube type of outdoor type VCB/Ring Main Unit any type with compatible existing system complete all as specified.Make:- C&S/Crompton/CG/C Sec/Schnider/Simmens |
| 75 | Supply, installation, testing and setting in repalacement of Digital Protection relay with Instant trip for phase and earth fault, relay to be fixed in existing 11 KV VCB drawout type, including taking down old relay. complete all as specified.(Make: ABB REJ601 or equivalent approved make) Please Enable Macros to View BoQ information |
| 76 | Supply, installation, testing and setting in repalacement of Digital Protection relay with Instant trip for phase and earth fault, relay to be fixed in existing 11 KV VCB drawout type, including taking down old relay. complete all as specified.(Make: ABB REJ601 or equivalent approved make) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 31, 2026
11:30 IST
Tender Published
Tender notice published.
TodayNov 21, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 21 daysNov 23, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 23 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender