Tender For special Repair / Replacement Of Lt Over Head Acsr Conductor, Reinforced Cement Concrete Poles, Under Ground Cable And Lt Panels At Otm And Perimeter Area Of Manesar Army C Under Ge (South), Delhi Cantt-10.
Tender Overview
Project Description
Tender for special Repair / Replacement Of Lt Over Head Acsr Conductor, Reinforced Cement Concrete Poles, Under Ground Cable And Lt Panels At Otm And Perimeter Area Of Manesar Army C Under Ge (South), Delhi Cantt-10.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 09-Nov-2026 | Corrigendum 01 | BOQ | 21-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Taking out old unserviceable ACSR conductor of any size from existing poles at various locations of OTM and perimeter of Manesar Army Camp tree distribued area incl aluminium binding wires,jumpering,bindings, insulators cross arms, bracings, supports , clamps and back plate stay wire etc complete all as specified and as directed. |
| 2 | Supply laying jointing and testing of XLPE insulated, armoured, heavy duty LT under ground cable 10 sqmm 2 core 1100 Volts grade with aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area for following sizes complete all as specified and as directed. |
| 3 | All as per srl item No 2.00 here-in-before but 16 Sqmm 4 Core. |
| 4 | All as per srl item No 2.00 here-in-before but 25 Sqmm 3.5 Core. |
| 5 | All as per srl item No 2.00 here-in-before but 35 Sqmm 3.5 Core. |
| 6 | All as per srl item No 2.00 here-in-before but 50 Sqmm 3.5 Core. |
| 7 | All as per srl item No 2.00 here-in-before but 70 Sqmm 3.5 Core. |
| 8 | All as per srl item No 2.00 here-in-before but 95 Sqmm 3.5 Core. |
| 9 | All as per srl item No 2.00 here-in-before but 120 Sqmm 3.5 Core. |
| 10 | Supply, install and testing of LT feeder piller panel outdoor type, floor mounted, weather vermin proof factory made, CPRI approved, facricated of 3.15 mm thick CRCA sheet, on frame of mild steel angle iron 40 mm x 40 mm x 6 mm, 45 cms above the ground level duly supported with mild steel angle iron 50 mm x 50 mm x 6 mm thick in PCC foundation (1:2:4), type B-I, using 20 mm graded crushed stone aggregate, LT panel shall be totally enclosed with front double door and rear opening with IP-54 protection as per IS/8623 duly powder coated for 433 volts, 3 phase, 4 wire having TPN Aluminium bus bars suitable for 250 Amps to supply load and 1 Phase + Neutral SPN Aluminium bus bars suitable for 100 Amps to security lights load duly drilled holes for connections, RYB insulated with different colour code and sleeved insulators complete prewired and cable connection with copper conductor wire upto copper bus bars including all incoming and outgoing cable connection with suitable size of copper lugs and cable glands complete all as specified and directed and also comprissing of following:- Incoming:- (i) MCCB 200 A 04 pole - 35 kA 01 Nos, ICS=100%=ICU (ii) MCCB 63 A 04 pole - 25 K 01 Nos, ICS=100%=ICU (iii) Copper bus bar suitable of capacityas per above description. (iv) Digital Voltmeter (v) Digital Ammeter- 01 No (vi) R-Y-B Neon indicator lamp panel mounting type (set of 03 ) = 01 Set (vii) Current Transformer as per suitable capacity (set of 03) (viii) Control wiring of suitable 4/6 sqmm copper wire for connecting above accessories-each job (ix) PCC Work for Panel foundation -Each job |
| 11 | Taking out old unserviceable LT Panel and supply installation, commissioning and testing of LT panel, outdoor type, floor mounted, weather vermin proof factory made, CPRI approved, facricated out of 3.15 mm thick CRCA sheet, on frame of mild steel angle iron 40 mm x 40 mm x 6 mm, 45 cms above the ground level duly supported with mild steel angle iron 50 mm x 50 mm x 6 mm thick in PCC foundation (1:2:4), type B-I, using 20 mm graded crushed stone aggregate, LT panel shall be totally enclosed with front double door and rear opening with IP-54 protection as per IS/8623 duly powder coated for 433 volts, 3 phase, 4 wire having TPN Aluminium bus bars suitable for 400 Amps load duly drilled holes for connections, RYB insulated with different colour code and sleeved insulators complete prewired and cable connection with copper conductor wire upto copper bus bars including all incoming and outgoing cable connection with suitable size of copper lugs and cable glands complete all as specified and directed and also comprissing of following:- Incoming:- (i) MCCB 200 A 04 pole - 35 kA 01 Nos, ICS=100%=ICU Make - L&T/C&S/Schneider Ougoing:-(ii) MCCB 100 A 04 pole - 25 kA 01 Nos, ICS=100%=ICU Make - L&T/C&S/Schneider (ii a) MCCB 63 A 04 pole - 25 K 01 Nos, ICS=100%=ICU Make - L&T/C&S/Schneider (iii) Copper bus bar suitable of capacity 480 A - set of 4 (iv) Digital Voltmeter (v) Digital Ammeter. Make: HPL/SEIMENS/L&T- 01 No (vi) R-Y-B Neon indicator lamp panel mounting type (set of 03 ) = 01 Set (vii) CT as per suitable capacity (set of 03) (viii) Control wiring of suitable 4/6 sqmm copper wire for connecting above accessories-each job (ix) PCC Work for Panel foundation -Each job Please Enable Macros to View BoQ information |
| 12 | Taking out old unserviceable LT Panel and supply installation, commissioning and testing of LT panel, outdoor type, floor mounted, weather vermin proof factory made, CPRI approved, facricated out of 3.15 mm thick CRCA sheet, on frame of mild steel angle iron 40 mm x 40 mm x 6 mm, 45 cms above the ground level duly supported with mild steel angle iron 50 mm x 50 mm x 6 mm thick in PCC foundation (1:2:4), type B-I, using 20 mm graded crushed stone aggregate, LT panel shall be totally enclosed with front double door and rear opening with IP-54 protection as per IS/8623 duly powder coated for 433 volts, 3 phase, 4 wire having TPN Aluminium bus bars suitable for 400 Amps load duly drilled holes for connections, RYB insulated with different colour code and sleeved insulators complete prewired and cable connection with copper conductor wire upto copper bus bars including all incoming and outgoing cable connection with suitable size of copper lugs and cable glands complete all as specified and directed and also comprissing of following:- Incoming:- (i) MCCB 200 A 04 pole - 35 kA 01 Nos, ICS=100%=ICU Make - L&T/C&S/Schneider Ougoing:-(ii) MCCB 100 A 04 pole - 25 kA 01 Nos, ICS=100%=ICU Make - L&T/C&S/Schneider (ii a) MCCB 63 A 04 pole - 25 K 01 Nos, ICS=100%=ICU Make - L&T/C&S/Schneider (iii) Copper bus bar suitable of capacity 480 A - set of 4 (iv) Digital Voltmeter (v) Digital Ammeter. Make: HPL/SEIMENS/L&T- 01 No (vi) R-Y-B Neon indicator lamp panel mounting type (set of 03 ) = 01 Set (vii) CT as per suitable capacity (set of 03) (viii) Control wiring of suitable 4/6 sqmm copper wire for connecting above accessories-each job (ix) PCC Work for Panel foundation -Each job Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 8 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender