Defence Statutory Bodies & Commissions/Committees Closing in 8 days TDR #58306892

Tender For special Repair / Replacement Of Lt Over Head Acsr Conductor, Reinforced Cement Concrete Poles, Under Ground Cable And Lt Panels At Otm And Perimeter Area Of Manesar Army C Under Ge (South), Delhi Cantt-10.

Issued by Statutory Bodies & Commissions/Committees · New Delhi, Delhi
Tender Value
46.50 Lakhs
Estimated cost
Bid Submission
21 Nov 2026
8 days left
EMD
93000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for special Repair / Replacement Of Lt Over Head Acsr Conductor, Reinforced Cement Concrete Poles, Under Ground Cable And Lt Panels At Otm And Perimeter Area Of Manesar Army C Under Ge (South), Delhi Cantt-10.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 09-Nov-2026 Corrigendum 01 BOQ 21-Nov-2026

BOQ

Name of Work:- SPL REPAIR / REPLACEMENT OF LT OVER HEAD ACSR CONDUCTOR, RCC POLES, UNDER GROUND CABLE AND LT PANELS AT OTM AND PERIMETER AREA OF MANESAR ARMY C UNDER GE (SOUTH), DELHI CANTT-10.
Sl. No. Item Description
1Taking out old unserviceable ACSR conductor of any size from existing poles at various locations of OTM and perimeter of Manesar Army Camp tree distribued area incl aluminium binding wires,jumpering,bindings, insulators cross arms, bracings, supports , clamps and back plate stay wire etc complete all as specified and as directed.
2Supply laying jointing and testing of XLPE insulated, armoured, heavy duty LT under ground cable 10 sqmm 2 core 1100 Volts grade with aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area for following sizes complete all as specified and as directed.
3All as per srl item No 2.00 here-in-before but 16 Sqmm 4 Core.
4All as per srl item No 2.00 here-in-before but 25 Sqmm 3.5 Core.
5All as per srl item No 2.00 here-in-before but 35 Sqmm 3.5 Core.
6All as per srl item No 2.00 here-in-before but 50 Sqmm 3.5 Core.
7All as per srl item No 2.00 here-in-before but 70 Sqmm 3.5 Core.
8All as per srl item No 2.00 here-in-before but 95 Sqmm 3.5 Core.
9All as per srl item No 2.00 here-in-before but 120 Sqmm 3.5 Core.
10Supply, install and testing of LT feeder piller panel outdoor type, floor mounted, weather vermin proof factory made, CPRI approved, facricated of 3.15 mm thick CRCA sheet, on frame of mild steel angle iron 40 mm x 40 mm x 6 mm, 45 cms above the ground level duly supported with mild steel angle iron 50 mm x 50 mm x 6 mm thick in PCC foundation (1:2:4), type B-I, using 20 mm graded crushed stone aggregate, LT panel shall be totally enclosed with front double door and rear opening with IP-54 protection as per IS/8623 duly powder coated for 433 volts, 3 phase, 4 wire having TPN Aluminium bus bars suitable for 250 Amps to supply load and 1 Phase + Neutral SPN Aluminium bus bars suitable for 100 Amps to security lights load duly drilled holes for connections, RYB insulated with different colour code and sleeved insulators complete prewired and cable connection with copper conductor wire upto copper bus bars including all incoming and outgoing cable connection with suitable size of copper lugs and cable glands complete all as specified and directed and also comprissing of following:- Incoming:- (i) MCCB 200 A 04 pole - 35 kA 01 Nos, ICS=100%=ICU (ii) MCCB 63 A 04 pole - 25 K 01 Nos, ICS=100%=ICU (iii) Copper bus bar suitable of capacityas per above description. (iv) Digital Voltmeter (v) Digital Ammeter- 01 No (vi) R-Y-B Neon indicator lamp panel mounting type (set of 03 ) = 01 Set (vii) Current Transformer as per suitable capacity (set of 03) (viii) Control wiring of suitable 4/6 sqmm copper wire for connecting above accessories-each job (ix) PCC Work for Panel foundation -Each job
11Taking out old unserviceable LT Panel and supply installation, commissioning and testing of LT panel, outdoor type, floor mounted, weather vermin proof factory made, CPRI approved, facricated out of 3.15 mm thick CRCA sheet, on frame of mild steel angle iron 40 mm x 40 mm x 6 mm, 45 cms above the ground level duly supported with mild steel angle iron 50 mm x 50 mm x 6 mm thick in PCC foundation (1:2:4), type B-I, using 20 mm graded crushed stone aggregate, LT panel shall be totally enclosed with front double door and rear opening with IP-54 protection as per IS/8623 duly powder coated for 433 volts, 3 phase, 4 wire having TPN Aluminium bus bars suitable for 400 Amps load duly drilled holes for connections, RYB insulated with different colour code and sleeved insulators complete prewired and cable connection with copper conductor wire upto copper bus bars including all incoming and outgoing cable connection with suitable size of copper lugs and cable glands complete all as specified and directed and also comprissing of following:- Incoming:- (i) MCCB 200 A 04 pole - 35 kA 01 Nos, ICS=100%=ICU Make - L&T/C&S/Schneider Ougoing:-(ii) MCCB 100 A 04 pole - 25 kA 01 Nos, ICS=100%=ICU Make - L&T/C&S/Schneider (ii a) MCCB 63 A 04 pole - 25 K 01 Nos, ICS=100%=ICU Make - L&T/C&S/Schneider (iii) Copper bus bar suitable of capacity 480 A - set of 4 (iv) Digital Voltmeter (v) Digital Ammeter. Make: HPL/SEIMENS/L&T- 01 No (vi) R-Y-B Neon indicator lamp panel mounting type (set of 03 ) = 01 Set (vii) CT as per suitable capacity (set of 03) (viii) Control wiring of suitable 4/6 sqmm copper wire for connecting above accessories-each job (ix) PCC Work for Panel foundation -Each job Please Enable Macros to View BoQ information
12Taking out old unserviceable LT Panel and supply installation, commissioning and testing of LT panel, outdoor type, floor mounted, weather vermin proof factory made, CPRI approved, facricated out of 3.15 mm thick CRCA sheet, on frame of mild steel angle iron 40 mm x 40 mm x 6 mm, 45 cms above the ground level duly supported with mild steel angle iron 50 mm x 50 mm x 6 mm thick in PCC foundation (1:2:4), type B-I, using 20 mm graded crushed stone aggregate, LT panel shall be totally enclosed with front double door and rear opening with IP-54 protection as per IS/8623 duly powder coated for 433 volts, 3 phase, 4 wire having TPN Aluminium bus bars suitable for 400 Amps load duly drilled holes for connections, RYB insulated with different colour code and sleeved insulators complete prewired and cable connection with copper conductor wire upto copper bus bars including all incoming and outgoing cable connection with suitable size of copper lugs and cable glands complete all as specified and directed and also comprissing of following:- Incoming:- (i) MCCB 200 A 04 pole - 35 kA 01 Nos, ICS=100%=ICU Make - L&T/C&S/Schneider Ougoing:-(ii) MCCB 100 A 04 pole - 25 kA 01 Nos, ICS=100%=ICU Make - L&T/C&S/Schneider (ii a) MCCB 63 A 04 pole - 25 K 01 Nos, ICS=100%=ICU Make - L&T/C&S/Schneider (iii) Copper bus bar suitable of capacity 480 A - set of 4 (iv) Digital Voltmeter (v) Digital Ammeter. Make: HPL/SEIMENS/L&T- 01 No (vi) R-Y-B Neon indicator lamp panel mounting type (set of 03 ) = 01 Set (vii) CT as per suitable capacity (set of 03) (viii) Control wiring of suitable 4/6 sqmm copper wire for connecting above accessories-each job (ix) PCC Work for Panel foundation -Each job Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58306892
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 46.50 Lakhs
LAST DATE 21-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for special Repair / Replacement Of Lt Over Head Acsr Conductor, Reinforced Cement Concrete Poles, Under Ground Cable And Lt Panels At Otm And Perimeter Area Of Manesar Army C Under Ge (South), Delhi Cantt-10.
Basic Detail
Tender No GE/TOKEN-66/2026-27
Bidding Type Tender
Location
City New Delhi
State Delhi
Key Dates
Publish Date 09 Nov 2026
Submission Date 21 Nov 2026
Open Date 01 Jan 0001
Finance
Tender Value 46.50 Lakhs
Tender Fee 500
EMD 93000
Exemption Available
Document List
BOQ_893645.xls
d10ac4b8-abd6-43ea-8f43-ef0a444c726a.html
SOCT66.pdf
Tendernotice_1.pdf
tenderpagesT66.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 09, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 21, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 8 days
Nov 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_893645.xls

html

d10ac4b8-abd6-43ea-8f43-ef0a444c726a.html

pdf

SOCT66.pdf

pdf

Tendernotice_1.pdf

pdf

tenderpagesT66.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender