Tender For special Rep To Extension Elect Sup And Security Lights Of 515 Abw Under Ge (Central) Bangalore.
Tender Value
45.75 Lakhs
Estimated cost
Bid Submission
20 Nov 2026
16 days left
EMD
91500
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Bengaluru Urban → Karnataka
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for special Rep To Extension Elect Sup And Security Lights Of 515 Abw Under Ge (Central) Bangalore.
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches in soft/loose soil not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr in depth for laying of UG cables and LT Panel board foundation etc and getting out complete all as specified and directed |
| 2 | All as per item No 1 above but depth exceeding 1.5 Mtr and not exceeding 3.00 Mtr complete all as specified and directed |
| 3 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cms in soft/loose soil complete all as specified and directed |
| 4 | Removing excavated soil to a distance not exceeding 50 mtrs and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as specified and directed |
| 5 | M&L for sand cushioning in trenches for bricks of UG cable with coarse sand, laid dry in trenches with uniform thickness complete all as specified and directed. Note : Puned Sand will be measured and paid. |
| 6 | Supply and lay burnt bricks of sub class 'B' laid dry across in trenches for cable protection complete all as specified and directed |
| 7 | M&L for PCC 1:4:8 type D2 (using 40mm size graded stone aggregates) as in foundation filling, mass concrete for road crossing etc. complete all as specified and directed |
| 8 | M&L for PCC 1:3:6 type C2 (using 40mm size graded stone aggregates) as in foundation filling, mass concrete for road crossing etc. complete all as specified and directed |
| 9 | M&L for PCC 1:2:4 type C2 (using 40mm size graded stone aggregates) as in foundation filling, mass concrete for road crossing etc. complete all as specified and directed |
| 10 | Taking out/down old U/S cables of any size and description complete all as specified and directed.Note : Earthwork if any involved, will be measured and paid separately. |
| 11 | Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 150 Sqmm x 3.5 core complete all as specified and directed |
| 12 | Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 240 Sqmm x 3.5 core complete all as specified and directed |
| 13 | Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 Sqmm x 4 core complete all as specified and directed |
| 14 | All as per Item No-13 but of size 10 Sqmm x 2 Core complete all as specified and directed |
| 15 | S&F Aluminium thimbles for end termination of cables and straight through ferrules for suitable for cable size 150 Sqmm to 240 Sqmm tightned with suitable crimping tools along with connecting accessories i.e. nut bolt washers etc complete all as specified and directed |
| 16 | All as per Item No -15 but suitable for cable size 10 to 25 Sqmm complete all as specified and directed |
| 17 | Taking down/dismantling of Old damaged RCC/Steel Pole of any size, type and description from Site complete all as specified and directed. |
| 18 | Supply and errecting swaged steel tubular poles, 9 meter long complete with cast iron base plate, finial taper plug, bolts, nuts, screws as specified type 410 SP-22 and complete with all accessories etc complete all as specified and directed |
| 19 | Taking down old U/S GI bracket Clamp nut bolt etc.of street light from pole complete all as specified and directed |
| 20 | M&L for GI bracket for street light fittings 32mm dia 1.2Mtr length including D/C clamps for PCC/Steel pole round or square nut bolt and washers etc and painiting of bracket and clamps complete all as specified and directed |
| 21 | Taking down Old U/S Street light fittings any type any size or description complete all as specified and directed. |
| 22 | S&F LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with mpact and corrosion resistant ncluding thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed |
| 23 | S&F LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with mpact and corrosion resistant ncluding thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed |
| 24 | Taking down /dismantling of flood light fittings any size any type or description complete all as specified and directed. |
| 25 | S&F LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. |
| 26 | S&F LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. |
| 27 | S&F in replacement of LED street light fittings driver for various capacity 45/60/90Watt for various existing make i.e. Bajaj/CG/Wipro as per site requirement complete all as specified and directed. |
| 28 | Taking down /dismantling Junction Boxes GI/PVC of any type or any size complete all as specified and directed. |
| 29 | S&F of Thermoplastic IP 66/67, weather proof, corrosion free, halogen and silicon free, UV reistence, insulated and shock proof, High impact strength, flame retardant and self extinguishing, Glow wires test conducted at 960 Deg junction box suitable for terminating cable for 6Sqmm/10 Sqmm/16 Sqmm including necessary cable gland and check nut Size of M32 (incoming and out going cbles) and mounting bracket clamp suitable size as per site with nut bolt washer complete all as specified and directed. |
| 30 | Taking down old street light timer /main switch of any size and any capacity complete all as specified and directed. |
| 31 | S&F outdoor type automatic timer for street light control three phase 230 volt maximum load 20 KW, 25 Amp rating with hinged LID complete all as specified and directed |
| 32 | Taking down old un serviceable feeder pillar Box of any capacity and description complete all as specified and directed. |
| 33 | M&L for Fabrication, Supply, testing, commissioning for Feeder pillar box made of copper bus bar of 100A capacity for one incoming cable and 4 out going cable housing in sheet metal enclosure of MS sheet 3.0mm thick, CRCA sheet, angle iron frame of size is suitable including locking arrangement & painting with two coats of powder coated paint over a coats of metal primer, suitable foundation & platform etc as per manufacturer's instruction complete all as specified and directed |
| 34 | Taking down old damaged PVC conduit Pipe of any size and description complete all as specified and directed. |
| 35 | S&F PVC Conduit pipe from PVC Junction Box to street light bracket for protection of cable fixing clamp on PCC poles drilled the hole and insert a PVC gutti and screwed suitable size screw and fix the clamp complete all as specified and directed. |
| 36 | Taking down old unserviceable aluminium wire 2/3 core any size complete all as specified and directed. |
| 37 | S&F PVC 3 Core copper cable 1.5Sqmm insulated for fixing of junction box to street light fittings complete all as specified and directed |
| 38 | Dismanling old unserviceable of MCB/MCCB/ACB any type any capacity complete all as specified and directed. |
| 39 | Dismantling of old unserviceable LT Panel board from Site complete all as specified and directed. |
| 40 | (Main Panel For Transformer)Supply, installation, commissioning and testing of Panel of suitable size, factory made, CPRI type tested, outdoor, cubical compartmental type, double door, front side openable with hinged doors & locking arrangement, made out of 2 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of size 50 mm x 50 mm x 6 mm, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length size, including fixing lugs bolts, screws etc. complete all as specified and directed :-BUSBAR CHAMBER 1250Amps uniformly rated, continuous duty, 415 V AC, 3 Phase and full size Neutral Aluminium (Throughout the length) busbars with colour coded heat shrink sleeves supported on SMC type grip supports, 25 KA for 1 sec.INCOMING(i) 800 A,4pole ACB-02 Nos(ii) Digital Volt-meter flush type with selector switch-01set(iii) Digital Ammeter flush type with selector switch prewiring with appropriate size 03 Nos CTS - 01 No(iv) LED cluster indication lamp(R Y B) set of 3-1set OUT GOING(i) 800 A,4 pole ACB-01 NoBUS COUPLER(i)800 A,4 pole ACB-01 No(ACB type - Manual Drawout With microprocessor release) |
| 41 | Utility Panel For DG SetSupply, installation, commissioning and testing of Panel of suitable size, factory made, CPRI type tested, outdoor, cubical compartmental type, double door, front side openable with hinged doors & locking arrangement, made out of 2 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of size 50 mm x 50 mm x 6 mm, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length size, including fixing lugs bolts, screws etc. all complete as specified and directedBUSBAR CHAMBER 1250Amps uniformly rated, continuous duty, 415 V AC, 3 Phase and full size Neutral Aluminium (Throughout the length) busbars with colour coded heat shrink sleeves supported on SMC type grip supports, 25 KA for 1 sec.INCOMING(i) 800 A,4pole ACB-02 Nos(ii) Digital Volt-meter flush type with selector switch-01set(iii) Digital Ammeter flush type with selector switch prewiring with appropriate size 03 Nos CTS - 01 No(iv) LED cluster indication lamp(R Y B) set of 3-1set OUT GOING(i) 630 A,4 pole MCCB-02 NoBUS COUPLER(i)800 A,4 pole ACB-01 No(ACB type - Manual Drawout With microprocessor release) |
| 42 | S&F LT Panel board suitable for indoor installation , fabricated out of 3.0mm thick CRCA sheet , CPRI Approved LT Panel board of standard size with cable entry from bottom , dust and vermin proof by providing suitable gaskets , double door type , with locking arrangement , mounted on angle iron frame of size not less than 40x40x6mm at height by 450mm above ground level and 300mm below ground level including grouting in PCC 1:4:8 0.5mtr depth and 300mm width including following accessories:- Incoming(i) MCCB 630 amps,35kA, 415 Volt,50Hz, 4P - 1 No.(ii) Digital Volt-meter flush type with selector switch - 01 set(iii) Digital Ammeter flush type with selector switch prewiring with appropriate size 03 Nos CTS - 01 No(iv) LED cluster indication lamp(R Y B) set of 3 - 1 set Busbar : - Aluminium busbar 15/25mm 3 phase 4 wire of 1000 Amps supported with ebonite insulation at 20cm interval -1setOutgoing(i) MCCB 400 Amps 25KA,415 volt 50Hz, 4P - 02 No(ii) MCCB 100 Amps 25KA,415 volt 50Hz, 4P - 02 No.(iii) MCB TPN 63 Amps 230 Volt,50Hz, - 01 Nos. |
| 43 | S&F LT Panel board suitable for indoor installation , fabricated out of 3.0mm thick CRCA sheet , CPRI Approved LT Panel board of standard size with cable entry from bottom , dust and vermin proof by providing suitable gaskets , double door type , with locking arrangement , mounted on angle iron frame of size not less than 40x40x6mm at height by 450mm above ground level and 300mm below ground level including grouting in PCC 1:4:8 0.5mtr depth and 300mm width including following accessories :-Incoming(i) MCCB 400 amps,36kA, 415 Volt,50Hz, 4P - 1 No.(ii) Digital Volt-meter flush type with selector switch - 01 set(iii) Digital Ammeter flush type with selector switch prewiring with appropriate size 03 Nos CTS - 01 No(iv) LED cluster indication lamp(R Y B) set of 3 - 1 set Busbar : - Aluminium busbar 15/25mm 3 phase 4 wire of 800 Amps supported with ebonite insulation at 20cm interval - 1 setOutgoing(i) MCCB 250 Amps 25KA, 415 volt 50Hz, 4P - 02 Nos.(ii) MCCB 100 Amps 16KA, 415 volt 50Hz, 4P - 01 No.(iii) MCB 63 Amps, 415 volt 50Hz, TPN - 01 No. |
| 44 | S&F LT Panel board suitable for indoor installation , fabricated out of 3.0mm thick CRCA sheet , CPRI Approved LT Panel board of standard size with cable entry from bottom , dust and vermin proof by providing suitable gaskets , double door type , with locking arrangement , mounted on angle iron frame of size not less than 40x40x6mm at height by 450mm above ground level and 300mm below ground level including grouting in PCC 1:4:8 0.5mtr depth and 300mm width including following accessories:- Incoming(i) MCCB 400 amps,36kA, 415 Volt,50Hz, 4P -1No.(ii) Digital Volt-meter flush type with selector switch-01set(iii) Digital Ammeter flush type with selector switch prewiring with appropriate size 03 Nos CTS - 01 No(iv) LED cluster indication lamp(R Y B) set of 3-1set Busbar : - Aluminium busbar 15/25mm 3 phase 4 wire of 800 Amps supported with ebonite insulation at 20cm interval -1setOutgoing(i) MCCB 250 Amps 36KA, 415 volt 50Hz, 4P - 02 Nos.(ii) MCCB 100 Amps 16KA, 415 volt 50Hz, 4P - 01 No.(iii) MCB TPN 63 Amps, 415 volt 50Hz, - 01 No. |
| 45 | S&F LT Panel board suitable for indoor installation , fabricated out of 3.0mm thick CRCA sheet , CPRI Approved LT Panel board of standard size with cable entry from bottom , dust and vermin proof by providing suitable gaskets , double door type , with locking arrangement , mounted on angle iron frame of size not less than 40x40x6mm at height by 450mm above ground level and 300mm below ground level including grouting in PCC 1:4:8 0.5mtr depth and 300mm width including following accessories:- Incoming(i) MCCB 250 Amps, 25kA, 415 Volt, 50Hz, 4P - 1 No.(ii) Digital Volt-meter flush type with selector switch - 01 Set(iii) Digital Ammeter flush type with selector switch prewiring with appropriate size 03 Nos CTS - 01 No(iv) LED cluster indication lamp (R Y B) set of 3 - 1 Set Busbar : - Aluminium busbar 15/25mm 3 phase 4 wire of 400 Amps supported with ebonite insulation at 20cm interval - 1 SetOutgoing(i) MCCB 200 Amps 36KA, 415 volt 50Hz, 4P - 01 No.(ii) MCCB 100 Amps 16KA, 415 volt 50Hz, 4P - 01 No.(iii) MCB TPN 63Amps, 415 volt 50Hz, - 01 No. |
| 46 | S&F of MCCB 4 pole 415 volt fixed type of capacity 400 Amps with breaking capacity 36 KA complete all as specified and directed. |
| 47 | S&F of MCCB 4 pole 415 volt fixed type of capacity 250 Amps with breaking capacity 25 KA complete all as specified and directed. |
| 48 | S&F of MCCB 3 pole 415 volt fixed type of capacity 100 Amps with breaking capacity 16 KA complete all as specified and directed. |
| 49 | S&F of MCB TPN 63 Amps, 415 volt 50Hz complete all as specified and directed. |
| 50 | M&L for repairing of LT Panel by fixing broken hinges welding, greasing, internal MCCB/Bus bar cubicle 10nOs repairing, tightining of earthing including new hinges, locks welding /brazing, greasing if reqd for complete LT Panel of various sizes complete all as dpeciefied and directed |
| 51 | M&L for fixing in repair locking arrangement of external doors of LT Panel by providing proper lock and lock mechanism, including replacement of lock if reqd complete all as specified and directed |
| 52 | M&L for Preparaton of oldsurfaces for painting of existing LT Panel/feeder pillar size up to 1.7x1.2x0.4 mtr by peeling existing paint layer and dust, cleaning of surface, and applying to coats of sytnhetic enamel paint of colour as decided over one coat of red oxide primer on all outdoor sides of LT panel including inner side of gates complete all as specified and directed |
| 53 | M&L for Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the earth plate at a depth of not less than 1.5 mtr below ground level connected to galvanized iron strip 25 x 4 mm as earthing lead by means of bolts, nuts and washers made out of GI/steel earth strip protected by GI light grade pipe of 40 mm dia and connecting to main panel board/switch board/control board all shown in electrical plate No 3 of SSR Pt I incl PCC chambers in 1:2:4 and RCC cover slab with 8mm dia MS bars reinforced at 10 cm center to center both ways incl earth work like excavation, returning filling back disposal etc complete all as specified and directed. |
| 54 | S&F in repalcement earth continuity conductor or main earthing lead of 25x4mm galvanised iron strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required complete all as specdified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 31, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 20, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysNov 23, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender