Tender For Periodical Service And B/R Repairs To E/M Installations Under Aor Of Ge (Af) E/M Chakeri.
Tender Overview
Project Description
Tender for Periodical Service And B/R Repairs To E/M Installations Under Aor Of Ge (Af) E/M Chakeri.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 19-Nov-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 26-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Material and labour for preparation of old decorated surfaces of walls, cornices etc. including brooming down or steel wire brushing, scraping down smoke, soot, moulds, moss and efflorescent salts and treating oil and greasy spots etc. and applying one coat of white wash on walls complete all as specified and directed by Engineer-in-Charge. |
| 2 | All as per item No. 1 above but applying two coats of white wash on walls complete all as specified and directed by Engineer-in-Charge. |
| 3 | All as per item No. 1 above but on ceiling complete all as specified and directed by Engineer-in-Charge. |
| 4 | Material and labour for preparation of old decorated surfaces of walls including brooming down or steel wire brushing, scraping down smoke, soot, moulds, moss and efflorescent salts and treating oil and greasy spots etc., levelling the disturbed places and edges by necessary filling with wall care putty to obtain a smooth and even finish using sand paper and applying one coat of oil bound distemper conforming to IS 428 of shade approved by Engineer-in-Charge complete all as specified and directed by Engineer-in-Charge. |
| 5 | Material and labour for complete removal of existing treatment i.e. white wash, colour wash, cement paint etc. on walls and ceiling with hand operated sander or manually where feasible, preparing the surfaces smooth including applying a coat of plaster of paris 1 mm thick and two coats of oil bound distemper conforming to IS 428 complete all as specified and directed by Engineer-in-Charge. |
| 6 | Material and labour for complete removal of existing treatment i.e. white wash, colour wash, cement paint etc. on walls and ceiling with hand operated sander or manually where feasible, preparing the surfaces smooth including necessary repair to depressions and cracks with waterproof wall care putty or plaster of paris, applying one coat of exterior water based primer and two coats of exterior weatherproof anti-algal 100% acrylic emulsion paint conforming to IS 15489 complete all as specified and directed by Engineer-in-Charge. |
| 7 | Material and labour for preparation of old painted surfaces of wood and wood based materials of any description not otherwise described, over 10 cm width or girth, and applying one coat of synthetic enamel paint conforming to IS 2932 complete all as specified and directed by Engineer-in-Charge. |
| 8 | All as per item No. 7 above but on steel surfaces complete all as specified and directed by Engineer-in-Charge. |
| 9 | Material and labour for preparation of old decorated surfaces of walls, cornices etc. including brooming down or steel wire brushing, scraping down smoke, soot, moulds, moss and efflorescent salts and treating oil and greasy spots etc. and applying one coat of cement paint conforming to IS 5410 on walls with brush complete all as specified and directed by Engineer-in-Charge. |
| 10 | Demolition of brick work built in cement mortar complete all as specified and directed by Engineer-in-Charge. |
| 11 | Material and labour for brick work with sub-class 'B' bricks conforming to IS 1077, straight or curved on plan exceeding 6 m mean radius, built in cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge. |
| 12 | All as per item No. 11 above but except bricks, using serviceable bricks recovered from the demolition under item No. 10 complete all as specified and directed by Engineer-in-Charge. |
| 13 | Taking down cement plaster from brick walls and RCC surfaces including raking out joints, hacking for key and scrubbing down with water where existing complete all as specified and directed by Engineer-in-Charge. |
| 14 | Material and labour for 15 mm thick rendering in cement mortar 1:4 on fair faces of concrete or brick surfaces, finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge. |
| 15 | Material and labour for 15 mm thick rendering in cement mortar 1:6 on other than fair faces of concrete or brick surfaces, finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge. |
| 16 | Material and labour for 10 mm thick cement plaster in cement mortar 1:3 on ceiling, finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge. |
| 17 | Material and labour for preparation of newly plastered surfaces of walls including cornices etc., applying a coat of plaster of paris 1 mm thick including rubbing with sand paper to achieve a smooth surface and sharp straight edges, one coat of alkali-resistant primer and two coats of oil bound distemper conforming to IS 428 complete all as specified and directed by Engineer-in-Charge. |
| 18 | Material and labour for preparation of newly plastered surfaces of walls and applying three coats of white wash complete all as specified and directed by Engineer-in-Charge. |
| 19 | Material and labour for preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed by Engineer-in-Charge. |
| 20 | Material and labour for preparation of newly plastered surfaces of walls and applying one coat of white wash and two coats of cement paint conforming to IS 5410 complete all as specified and directed by Engineer-in-Charge. |
| 21 | Material and labour for preparation of newly plastered surfaces of walls including cornices etc., preparing the surfaces smooth including necessary repair to depressions and cracks with waterproof wall care putty or plaster of paris, applying one coat of exterior water based primer and two coats of exterior weatherproof anti-algal 100% acrylic emulsion paint conforming to IS 15489 complete all as specified and directed by Engineer-in-Charge. |
| 22 | Material and labour for washing existing efflorescence on walls with acid or alkali solution as directed by Engineer-in-Charge, drying the wall for a minimum of 3 days and checking for any further efflorescence, washing the surface with clean water and leaving it to dry for 3 to 4 hours before application of further treatment complete all as specified and directed by Engineer-in-Charge. |
| 23 | Supply and application of one component penetrative-cum-film forming interior waterproofing solution with negative hydrostatic resistance up to 4 bar, at a minimum coverage of 350 ml per Sqm in a single coat using brush or roller complete all as specified and directed by Engineer-in-Charge. |
| 24 | Supply and application of two component acrylic polymer modified cementitious coating on masonry surfaces without plaster, with hydrostatic resistance up to 5 bar, at a minimum coverage of 1.75 Kg per Sqm in two coats using roller or brush with a gap of 4 to 6 hours between coats, the coats being applied perpendicular to each other complete all as specified and directed by Engineer-in-Charge.Note: The coverage shall be strictly maintained for film formation. |
| 25 | Dismantling floor, hearth or wall tiling including cement mortar bedding, removing serviceable material to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge. |
| 26 | Material and labour for glazed ceramic coloured tiles 300 x 450 mm, 6 to 7 mm thick, conforming to IS 15622 on vertical surfaces such as dado, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles, over and including 10 mm thick rendering in cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge. |
| 27 | Material and labour for 7 to 8 mm thick non-skid ceramic coloured tiles conforming to IS 15622, square or rectangular, area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc., laid and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the shade of tiles, over and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge. |
| 28 | Material and labour for 25 mm thick cement concrete type B-0 1:2:4 using 12.5 mm graded stone aggregate as in levelling or sub-base of flooring complete all as specified and directed by Engineer-in-Charge. |
| 29 | Dismantling of concertina coil 600 mm diameter of any shape including six lines of razor wire complete all as specified and directed by Engineer-in-Charge.Note: Concertina coil and six lines of razor wire together shall be measured as one Rm. |
| 30 | Re-straining and re-securing existing galvanised 2 strand steel barbed wire fencing of any description including making good staples etc. complete all as specified and directed by Engineer-in-Charge. |
| 31 | Supply and fixing of 600 mm diameter punched tape concertina coil with two handles and spikes at both ends of the coil, with dovetail clips of 18 SWG, including 7 razor wires of 6 m length each with medium size barbs of 20 mm length and 14 mm width, 51 pins and 128 clips in each coil, and zinc coating of 230 g/Sqm on core wire, weight of coil not less than 1.5 Kg per Rm complete all as specified and directed by Engineer-in-Charge. |
| 32 | Supply and fixing in repairs of mild steel lath section in single piece 1.25 mm thick with interlocking curls at both edges complete all as specified and directed by Engineer-in-Charge. |
| 33 | Supply and fixing in repairs of mild steel clips riveted at either end and fitted on the ends of lath section complete all as specified and directed by Engineer-in-Charge. |
| 34 | Supply and fixing in repairs of mild steel sheet 1.00 mm thick as hood cover of any shape with flat iron stiffeners at both edges, fixed to the bracket plate complete all as specified and directed by Engineer-in-Charge. |
| 35 | Supply and fixing in repairs of mild steel spring of size to suit the existing rolling shutter complete all as specified and directed by Engineer-in-Charge. |
| 36 | Taking down rolling shutters of any description not exceeding 10 Sqm area, straightening of springs, guide channels, hood cover etc. and refixing in the original position including greasing and oiling, i.e. complete servicing to make the shutter fully functional complete all as specified and directed by Engineer-in-Charge.Note: Replacement laths, clips, hood cover and springs shall be measured and paid separately under item Nos. 32 to 35. |
| 37 | Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by Engineer-in-Charge. |
| 38 | Supply and fixing of steel rolling shutter, gear operated type with bevel gear box and crank handle, laths 1.25 mm thick, with safety lever lock of mild steel with 4 levers and ball bearings, including top cover, anchoring rod, hasp and staple and one shop coat of primer, erected in position as indicated complete all as specified and directed by Engineer-in-Charge. |
| 39 | Material and labour for repair of ceilings, RCC chhajjas, roof projections and fascias with exposed reinforcement, area not exceeding 1.5 Sqm each and RCC thickness not exceeding 150 mm, applying latex acrylic based emulsion to the exposed reinforcement and one coat of cement slurry, filling with cement concrete type B-0 1:2:4 using 12.5 mm graded stone aggregate at damaged concrete surfaces, finishing the surface with 5 mm thick cement mortar 1:3 and applying two coats of cement paint conforming to IS 5410 on the finished surface complete all as specified and directed by Engineer-in-Charge. |
| 40 | Demolition of unreinforced cement concrete not exceeding 15 cm thick, below or above ground level complete all as specified and directed by Engineer-in-Charge. |
| 41 | Material and labour for 40 mm thick cement concrete type B-0 1:2:4 using 12.5 mm graded stone aggregate in floors, finished even and fair complete all as specified and directed by Engineer-in-Charge. |
| 42 | Material and labour for cement concrete type C-2 1:3:6 using 40 mm graded stone aggregate in foundations, filling, sub-base and mass concrete complete all as specified and directed by Engineer-in-Charge. |
| 43 | Material and labour for hardcore of broken stone or boulders of gauge exceeding 63 mm but not exceeding 100 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rolled or rammed to a true surface complete all as specified and directed by Engineer-in-Charge. |
| 44 | Demolition of roof treatment including padding concrete of any description and mud on roof of any thickness by hand held electric drills, cutting machines, chisels etc., including roughening old concrete surfaces by picking, sweeping clean and washing down with water to remove dust etc. complete all as specified and directed by Engineer-in-Charge.Note: Direct use of hammers on RCC roof for demolition is strictly prohibited. |
| 45 | Material and labour for cement concrete type B-0 1:2:4 using 12.5 mm graded stone aggregate in padding, coping and roof kerbs including haunching, benching etc. with non-shrink admixture and curing with curing compound complete all as specified and directed by Engineer-in-Charge. |
| 46 | Material and labour for 10 mm thick rendering in cement mortar 1:3 on fair faces of concrete surfaces and roof tops, mixed with integral liquid waterproofing compound, finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.Note: Waterproofing compound shall be measured and paid separately under item No. 47. |
| 47 | Supply only of integral waterproofing compound conforming to IS 2645 complete all as specified and directed by Engineer-in-Charge. |
| 48 | Removal of demolished material to a distance of 500 m or under, beyond the lead included in the rates, including loading and unloading complete all as specified and directed by Engineer-in-Charge. |
| 49 | Material and labour for preparation of newly plastered surfaces of roof including cleaning with wire brush or pressure hose and applying high performance polyurethane liquid membrane waterproofing coating, cold applied by spray or brush in two coats at 1.5 Kg per Sqm for two coats, with elongation of 300% to 700% and tensile strength not less than 3 N/sqmm as per ASTM D412 and ASTM D2370, crack bridging ability of 3.5 mm as per ASTM C1305 and Shore A hardness not less than 60 as per ASTM D2240, including epoxy primer at 0.15 Kg per Sqm and a 40 GSM geotextile laid over the first coat while it is still wet, as per the manufacturer's instructions complete all as specified and directed by Engineer-in-Charge. |
| 50 | Taking down wall panelling and similar work complete all as specified and directed by Engineer-in-Charge. |
| 51 | Supply and fixing of 5 mm thick plain colour PVC sheet in wall panelling, strips and channels feathered at the edges for fixing on solid wall lining and solid PVC partitions, including fillets and solvent cement complete all as specified and directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
TodayBid Submission Deadline
Online submission via eProcurement portal.
TodayBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender