Tender For Repair/Maint Of Lt Panel, Feeder Pillar And Other Connected Items Under Ge(South) Bangalore
Tender Value
30 Lakhs
Estimated cost
Bid Submission
21 Nov 2026
19 days left
EMD
60000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Bengaluru Urban → Karnataka
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Maint Of Lt Panel, Feeder Pillar And Other Connected Items Under Ge(South) Bangalore
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling of old unserviceable feeder LT Panel/Feeder pillar box any size any capacity |
| 2 | Supply and fixing in replacement LT Panel board outdoor type fabricated out of 3.15mm thick CRCA Sheet steel factory made vermin proof duly painted with two coat of synthetic enamelled paint over a coat of red oxide primer or powder coated, double door, water proof dust and vermin proof hinged and lockable doors inlcuding rain protection cover on top and complete with interconnections, with copper wires, tapes, opening from both sides with cable entry from bottom, with cable alley and bus bar chamber, bonding to earth and painting, including angle iron frame of size minimum 40x40x6mm having 4 legs 0.60 mtr long including grouting in PCC 1:4:8, to the reqd depth all as specified and directed by Engineer-in-Charge. (LT Panel should be able to accommodate Items as mentioned below, MCCB, Change Over, Multifunction meters will be measured and paid seperately under respective item of work) INCOMING(a) MCCB 250 amps 4 pole 35 KA adjustable thermal and fixed magnetic setting - 01 NoBusbar : - Aluminium busbar 3 phase 4 wire of 400 Amps supported with ebonite insulators -1setOUTGOING(b) MCCB 160 Amps 4 pole 25 KA with adjustable thermal and fixed magnetic setting – 03 Nos(c) Star delta Starter - 02 Nos(d) Chageover switch, 250 Amps, 4 pole - 1 No(e) Multifuction meter suitable to display voltage, current, frequency, power factor and other relavent parameters for three phase 4 wire 415 Volts System including three nos CTs of appropriate ratio – 01 No(f) LED indicator RYB – 03 Nos |
| 3 | Supply and fixing in replacement of old unserviceable LT feeder pillar outdoor type made out of 14 SWG CRCA Sheet steel factory made vermin proof duly painted with two coat of synthetic enamelled paint over a coat of red oxide primer having 04 Nos aluminum bus bar 400 Amps mounted on post insulators with holes in bus bar for fixing of LT Cables minimum four nos, water proof dust and vermin proof hinged and lockable doors inlcuding rain protection cover on top and bonding to earth and painting, fixed on angle iron frame and having 4 legs 1.0 mtr long including grouting in PCC 1:4:8, 0.5mtr depth, complete all as specified and directed by Engineer-in-Charge. (Note:This panel shall be a FRONT operated, with cable entry from the bottom.) |
| 4 | M&L for repairing of LT Panel by fixing broken hinges, welding , greasing , internal MCCB/Bus bar cubicle 10 nos repairing , tightining of earthing including new hinges , locks welding /brazing , greasing including if reqd for complete LT Panel off up to size 1.7x1.2x0.4mtr Complete all as specified and as directed by Engr-In-Charge. |
| 5 | M&L for fixing in repair locking arrangement of external doors of LT Panel by providing proper lock proper lock mechanism , including replacement of lock if reqd at site Complete all as specified and as directed by Engr-In-Charge. |
| 6 | M&L for Preparaton of old surfaces for painting of existing LT Panel/feeder pillar size up to 1.7x1.2x0.4mtr by peeling existing paint layer and dust , cleaning of surface , and applying to coats of sytnhetic enamel paint of colour as decided over one coat of red oxide primer on all outdoor of LT panel including inner side of gates complete all as specified and directed by Engr-in -Charge. |
| 7 | Supply and fixing in replacement of Multifunction meter digital type suitable for displaying Voltage, Current, Power factor, Frequency and other relevant parameters of three phase four wire 415 Volts system prewired, operates on 230/415 Volts Auxiliary supply having accuracy class-1 including making provision for mounting in existing LT Panel and taking down existing complete all as specified and directed by Engr-In-Charge. |
| 8 | Supply and fixing in replacement of Voltmeter Digital Type suitable for displaying Single phase/Three phase Voltage of three phase four wire 415 Volts system with selector switch prewired, operates on 230/415 Volts Auxiliary supply having accuracy class-1 including making provision for mounting in existing LT Panel complete all as specified and directed by Engr-In-Charge. |
| 9 | Supply and fixing in replacement of Ammeter Digital Type suitable for displaying Single phase/Three phase Current of three phase four wire 415 Volts system with selector switch prewired, operates on 230/415 Volts Auxiliary supply having accuracy class-1 including three nos CT's of appropriate ratio and making provision for mounting in existing LT Panel complete all as specified and directed by Engr-In-Charge. |
| 10 | Supply and fixing in replacement RYB indicator lamps set of three with mounting provision on existing panel board complete all as specified and directed by Engr-In-Charge. |
| 11 | Material & Labour for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundation, mass concrete for road crossing etc. complete all as specified and as directed by Engr-In-Charge. |
| 12 | Material & Labour for PCC 1:3:6 type D2 (using 20mm graded stone aggregate) as in foundation, mass concrete for road crossing etc.,complete all as specified and as directed by Engr-In-Charge. |
| 13 | Material & Labour for PCC 1:2:4 type B2 (using 40mm graded stone aggregate) as in foundation, mass concrete for road crossing etc. complete all as specified and as directed by Engr-In-Charge. |
| 14 | S&F in replacement of MCCB 3/4 pole 415 volt fixed type of capacity 400 Amps with breaking capacity 36 KA Make- Matching with existing complete all as specified and directed by Engr-In-Charge |
| 15 | S&F in replacement of MCCB 3/4 pole 415 volt fixed type of capacity 250 Amps with breaking capacity 25 KA Make- Matching with existing complete all as specified and directed by Engr-In-Charge |
| 16 | S&F in replacement of MCCB 3/4 pole 415 volt fixed type of capacity 200 Amps with breaking capacity 25 KA Make- Matching with existing complete all as specified and directed by Engr-In-Charge |
| 17 | S&F in replacement of MCCB 3/4 pole 415 volt fixed type of capacity 160 Amps with breaking capacity 25KA Make- Matching with existing complete all as specified and directed by Engr-In-Charge |
| 18 | S&F in replacement of MCCB 3/4 pole 415 volt fixed type of capacity 125 Amps with breaking capacity 16 KA Make- Matching with existing complete all as specified and directed by Engr-In-Charge |
| 19 | S&F in replacement of MCCB 3 pole 415 volt fixed type of capacity 100 Amps with breaking capacity 16 KA Make- Matching with existing complete all as specified and directed by Engr-In-Charge |
| 20 | S&F in replacement of MCCB 3/4 pole 415 volt fixed type of capacity 63 Amps with breaking capacity 16 KA Make- Matching with existing complete all as specified and directed by Engr-In-Charge |
| 21 | S&F in replacement MCB TPN 63 Amp 9 kA , 'C' curve 415 volts complete all as specified and directed by Engr-In-Charge. |
| 22 | S & F of Onload front handle change over switch of capacity 100Amp 415 volt 50 Hz 4P with encloser, handle matching with existing including taking down of unserviceable change over complete all as specified and as directed by Engr-InCharge. Make- Indoasian/havells/Legrand |
| 23 | S & F of Onload front handle change over switch of capacity 200 Amp 415 volt 50 Hz 4P with encloser, handle matching with existing including taking down of unserviceable change over complete all as specified and as directed by Engr-InCharge. Make- Indoasian/havells/Legrand |
| 24 | Taking down old unserviceable service cable 10/6 sqmm 2 core |
| 25 | Supplying and fixing 1100 volts grade heavy duty cable PVC insulated multi stranded aluminum conductor, 6 Sqmm twin core served with inner sheathing of PVC tape and overall PVC sheathed in service connections complete all as specified and directed by Engr-In-Charge |
| 26 | Supplying and fixing 1100 volts grade heavy duty cable PVC insulated multi stranded aluminum conductor, 10 Sqmm twin core served with inner sheathing of PVC tape and overall PVC sheathed in service connections complete all as specified and directed by Engr-In-Charge |
| 27 | Excavation in trenches in Hard/dense soil not exceeding 1.5 M wide and not exceeding 1.5 M in depth for laying of UG cables and LT Panel board foundation etc and complete all as specified and directed . |
| 28 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cms in any type of soil. |
| 29 | Removing excavated soil to a distance not exceeding 50 mtrs and depositing where directed at a level not exceeding 1.5 M above the starting point all as directed. |
| 30 | M&L for M & L Sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180 mm thickness, complete all as specified and as directed. Note : For the purpose of Payment, Punned thickness of Sand Cushioning only shall be measured and paid for.sand cushioning in trenches for bricks of u/g cable with coarse sand laid dry in trenches with uniform thickness. |
| 31 | Supply and lay burnt bricks of sub class 'B' laid dry across in trenches for cable protection all as specified and directed. |
| 32 | Relaying of serviceable Bricks retrieved from taking down in trenches for cable protection over sand cushioning complete all as specified and directed by Engr-In-Charge |
| 33 | Taking down/out unserviceable LT Cables of any Cross Sectional Area and Connections and joints including Pipes, Bricks, etc of any description laid in trenches or fixing with Walls/Poles, segreating serviceable Pipes, Cables etc and keep serviceable cable and Bricks in safe custody for reuse, complete all as specified and as directed.Note : Earthwork will be measured and paid under appropriate Items. |
| 34 | Supply, laying and testing cable XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 Sqmm x 2 core including thimbles at ends/strraight through ferrules as reqd for connection duly insulated including taking down unserviceable UG cable complete all as specified and directed. (Make- Havells/Polycab/Paragon/Gloster/KEI) |
| 35 | All as per Item No 34 but of size 16 Sqmm x 4 Core complete all as specified and directed by Engr-In-Charge |
| 36 | All as per Item No 34 but of size 25 Sqmm x 3.5 Core complete all as specified and directed by Engr-In-Charge |
| 37 | All as per Item No 34 but of size 35 Sqmm x 3.5 Core complete all as specified and directed by Engr-In-Charge |
| 38 | All as per Item No 34 but of size 50 Sqmm x 3.5 Core complete all as specified and directed by Engr-In-Charge |
| 39 | All as per Item No 34 but of size 70 Sqmm x 3.5 Core complete all as specified and directed by Engr-In-Charge |
| 40 | All as per Item No 34 but of size 95 Sqmm x 3.5 Core complete all as specified and directed by Engr-In-Charge |
| 41 | All as per Item No 34 but of size 120 Sqmm x 3.5 Core complete all as specified and directed by Engr-In-Charge |
| 42 | All as per Item No 34 but of size 185 Sqmm x 3.5 Core complete all as specified and directed by Engr-In-Charge |
| 43 | Labour only for Re-Laying fixing or passing through pipe only LT 1100 Volts grade cable of any size incl connections from LT panel board of any size Complete all as specified and directed by Engr-in-Charge. Please Enable Macros to View BoQ information |
| 44 | Labour only for Re-Laying fixing or passing through pipe only LT 1100 Volts grade cable of any size incl connections from LT panel board of any size Complete all as specified and directed by Engr-in-Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 31, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 21, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysNov 23, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender