Public Administrative Department Local Bodies Closing in 7 days TDR #58302518

Tender For E-Tender - Supply, Erection, Testing And Commissioning Of 1 No Of 11Kv, 25Kva, 630A Outdoor Panel Ring Main Gear, Single Panel Vaccum Circuit Breaker, Supply And Replacement Of 2 Nos Of 630A Air Circuit Breakers (Acb) With 4 Nos. Of 63A, 1

Issued by Local Bodies · Chennai, Tamil Nadu
Tender Value
31.78 Lakhs
Estimated cost
Bid Submission
13 Nov 2026
7 days left
EMD
31790
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chennai → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for E-Tender - Supply, Erection, Testing And Commissioning Of 1 No Of 11Kv, 25Kva, 630A Outdoor Panel Ring Main Gear, Single Panel Vaccum Circuit Breaker, Supply And Replacement Of 2 Nos Of 630A Air Circuit Breakers (Acb) With 4 Nos. Of 63A, 1 No. 100A, 2 Nos. Of 200A And 400A Triple Pole Neutral Switch Disconnector Fuse Units (Tpn Sdfu) And Necessary Foundation At Amma Arangam Feeder Panel In Div 102, Zone 8

BOQ

Name of Work:- E-Tender – Supply, erection, testing and commissioning of 1 no of 11KV, 25KVA, 630A outdoor panel ring main gear, single panel vaccum circuit breaker, supply and replacement of 2 nos of 630A Air Circuit Breakers (ACB) with 4 nos. of 63A, 1 no. 100A, 2 nos. of 200A and 400A Triple Pole Neutral Switch Disconnector Fuse Units (TPN SDFU) and necessary foundation at Amma arangam feeder panel in div 102, Zone 8
Sl. No. Item Description
1Supply of Copper Flat (25 x 3mm) as per technical specification
2Plastering the surface of walls with Cement Mortar 1:3 (One cement and Three plastering sand), 20mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used , curing etc., complete complying with standard specification and as directed by the departmental officers. (sump wall) as per technical specification.
3Petty iron work for truss, straps etc., (wrought & fixed) labour only as per technical specification
4Supply of I.SI.MARKED 31/2X240 SQ.MM CABLE as per technical specification
5Supply, erection, testing and commissioning of 11 KV, 25 KA, 630 A, HT Outdoor Three Panel Ring Main Gear complete as per specification
6Supply 240 sq.mm. 3 core HT XLPE 11KV (E) cable as per technical specification
7Supply and installation of 63A TPN switch SWITCH DISCONNECTOR FUSE UNITS in sheet steel enclosure with HRC fuses double break as per technical specification
8Supply and installation of 100A TPN switch SWITCH DISCONNECTOR FUSE UNITS in sheet steel enclosure with HRC fuses double break as per technical specification
9Supply and installation of 630Amps 4pole 50KVA Microprocessor Base EDO Breaker as per technical specification
10Supply and installation of 200A TPN switch SWITCH DISCONNECTOR FUSE UNITS in sheet steel enclosure with HRC fuses double break as per technical specification
11Supply of 240-300 sq.mm. 3 core HT Cable Outdoor Terminations XLPE 11KV (E) - EPKT 3372 (HEAT SHRINKABLE HT CABLE JOINT KIT CONSISTS OF RIGHT ANGLE / STRAIGHT BOOTS, WRAP AROUND SLEEVES, INSULATION TAPE, BUTYL SEALANT, CONSTANT FORCE SPRING, CLAMPS, TINNED COPPER BRAIDS ETC.,) as per technical specification
12Providing and laying in position, Standardised Concrete Mix M- 25 Grade using In-situ Concrete batching plant/ Ready Mix Concrete (RMC) adopting weigh batch method in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 350 kg/m3 and maximum water cement ratio of 0.50, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m’) 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including Conveyance of concrete from batching plant to Work site, Electricity charges and other works & labour cost involved for concrete production, laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials). as per technical specification.
13Laying of following size Copper Flats & Wires with necessary fastners - 25x6mm Copper flat for Transformer, MV Panel body earthing as per technical specifications
14LT CABLES: Laying of 31/2 C X 240 Sq.mm LT Cable as per technical specifications
15HT CABLES: Laying of 3 C X 240 Sq.mm HT Cable as per technical specifications
16Supply of gland with termination for 31/2 C X 240 Sq.mm LT Cable as per specifications
17Dismantling RCC by manual / by using deploying machineries as per technical specification
18Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, Sill slabs etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid with silver oak joists of size 10cm x 5cm & 7.5cm x 5cm as support runner , vertical stiffener, side support and Top Horizontal stiffener spaced at about 60cm to 90cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid). FOUNDATION as per technical specification
19Brick work in following Cement Mortar using best quality Fly ash Brick of size 230x110x70mm with class designation of 10 conforming to IS 13757-1993 or IS 12894- 2002 for foundation and basement including Cost of Mortar Plasticizer, curing, etc., complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally. other type of bond shall be done as directed by the Executive Engineer in charge. In Cement Morter 1:5 as per technical specification
20Supply and installation of 11 KV, 25 KA, 630 A, HT Outdoor Single Panel Vaccum Circuit Breaker complete as per technical specification
21Body Earth : Erection of 100mm dia Cast Iron earth electrode of10 length buried in ground as per IS with necessary connecting clamps, watering arrangement &fasteners etc.as per technical specifications For Body Earth
22Supplying, fabricating and placing in position Ribbed Tor Steel / TMT reinforcement grills of all variety like HYSD/CTD/TMTand all grade like Fe 500, Fe550D, Fe 500 D etc., for all RCC works as per design given including cost of steel reinforcement and G.I. binding wire, wastage etc. complete complying with standard specification and as directed by the departmental officers.(Contractor has to make his own arrangements for the supply of steel reinforcement and binding wire) Upto plinth / Basement level as per technical specification
23Neutral Earth : Supply of 100 mm diacast iron pipe copper plate earth electrode of size 600x600x3.15mm at a depth of 3000mm filled with salt, charcoal etc., construction of chamber, providing heavy duty concrete cast slab, painting & making etc., & as per the technical specification. For Neutral
24Supply and installation of Chain Link - 2 x 2 using 10 Gauge Galvanised Iron Wire (of all sizes) as per technical specification
25Earth work excavation for foundation by Mechanical means for Isolated & Combined Footing etc in all soils and subsoils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 100 mts and clearing and levelling including dressing of sides and raming of bottoms etc., complete complying with standard specification and as directed by the departmental officers.- Upto 2.40m Footing Depth. (including Refilling charges) as per technical specification
26Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) as per technical specification
27Statuatory approval; Liasioning with The Chief Electrical Inspector to Government of Tamilnadu for preparation & submission of drawings and documents etc., obtaining approval for drawing & Safety Certificate. The cost shall Including submission of handing over document with As built. as per technical specifications as per technical specification
28Cement Concrete 1:5:10 (One cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken jelly for flooring including laying, consolidating, finishing, rendering the top surface rough to receive the floor, curing, etc. complete complying with standard specification and as directed by the departmental officers. (The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the departmental officers - Mixing by mechanical means as per technical specification
29Supply and installation of 400A TPN switch SWITCH DISCONNECTOR FUSE UNITS in sheet steel enclosure with HRC fuses double break as per technical specification
30Supply and installation of MS Channel Section (ISMC 100) as per technical specification Including GST(18%) Including GST(18%) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58302518
AUTHORITY Local Bodies
TENDER VALUE 31.78 Lakhs
LAST DATE 13-11-2026
Authority
Authority Name Corporation Of Chennai
Work Description Tender for E-Tender - Supply, Erection, Testing And Commissioning Of 1 No Of 11Kv, 25Kva, 630A Outdoor Panel Ring Main Gear, Single Panel Vaccum Circuit Breaker, Supply And Replacement Of 2 Nos Of 630A Air Circuit Breakers (Acb) With 4 Nos. Of 63A, 1 No. 100A, 2 Nos. Of 200A And 400A Triple Pole Neutral Switch Disconnector Fuse Units (Tpn Sdfu) And Necessary Foundation At Amma Arangam Feeder Panel In Div 102, Zone 8
Basic Detail
Tender No El.D.C.No.SMII/P5/4233/2026
Bidding Type Tender
Location
City Chennai
State Tamil Nadu
Key Dates
Publish Date 31 Oct 2026
Submission Date 13 Nov 2026
Open Date 13 Nov 2026
Finance
Tender Value 31.78 Lakhs
Tender Fee Ref. Documents
EMD 31790
Exemption Not Available
Document List
4233tenderdocument.pdf
BOQ_864892.xls
c9c01c9f-4c75-4d17-a0ae-700c4abdf95d.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 31, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 13, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Nov 13, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
pdf

4233tenderdocument.pdf

xls

BOQ_864892.xls

html

c9c01c9f-4c75-4d17-a0ae-700c4abdf95d.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender