Petroleum and Natural Gas Boards / Undertakings / PSU Closing in 4 days TDR #58301985

Tender For Development Of New A Site Ro At Batadraba Than Gate To Christ Jyoti School On Sh 47, District - Nagaon, State: Assam Under Guwahati Divisional Office Of Indianoil Aod State Office

Issued by Boards / Undertakings / PSU · Nagaon, Assam
Tender Value
89.83 Lakhs
Estimated cost
Bid Submission
07 Nov 2026
4 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Nagaon → Assam
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Development Of New A Site Ro At Batadraba Than Gate To Christ Jyoti School On Sh 47, District - Nagaon, State: Assam Under Guwahati Divisional Office Of Indianoil Aod State Office

BOQ

Name of Work:- Development of New A Site RO at BATADRABA than Gate to Christ Jyoti School on SH 47, District – Nagaon, State: Assam under Guwahati Divisional Office of IndianOil AOD State Office
Sl. No. Item Description
1LAND DEVELOPMENT
2Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling & neatly dressing of disposed soil completely to be paid separately as per item no. MPLCN00600
3i) All kinds of Soil
4Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm. depth dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth within premises
5iii) With material confirming to grade-III (size 26.5 mm to .075 mm) having CBR value -20, Thickness as desired
6Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to .075 mm) to wet mix macadam (WMM) specifications including premixing the material with water at OMC for all leads and lifts, laying in uniform layers with mechanical paver finisher in sub-base/base course on well prepared surface and compacting with vibratory roller of 8 to 10 ton capacity to achieve the desired density, complete as per specifications & directions of Engineer-in- charge
7Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level:
8ii) M40 grade 80 mm thick reflective type Lacquered finish
9i) All kinds of Soil
10vii) 1:3:6(1 Cement : 3 Fine Sand : 6 Graded stone aggregate of 40mm)
11ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH
12iv) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 40mm)
13ii)12 mm cement plaster of mix 1:6 (1 cement: 6 fine sand)
14Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture.
15Dry stone pitching 22.5 cm thick including supply of stones and preparing surface complete
16CULVERT & OPEN DRAIN
17i) All kinds of Soil
18i) Local Fine Sand within grading zone IV
19v) 1:3:6(1 Cement : 3 Coarse Sand : 6 Graded stone aggregate of 20mm)
20ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm
21ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786
22Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete:
23i) Foundations,footings,bases of columns, etc. for mass concrete
24ii) Walls (any thickness) including attached pilasters, buttress, plinth and string courses etc.
25i) 6mm thick plaster of mix 1:3 (1 cement: 3 fine sand)
26Providing Neat cement punning
27Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture.
28Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling & neatly dressing of disposed soil completely to be paid separately as per item no. MPLCN00600
29i) All kinds of Soil
30Extra for every additional lift of 1.5m or part thereof in excavation or banking excavated or stacked materials in all kinds of soil
31Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, within premises and lift upto 1.5m
32Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level:
33iv) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 40mm)
34vii) 1:3:6(1 Cement : 3 Fine Sand : 6 Graded stone aggregate of 40mm)
35Centering and shuttering including strutting, propping etc. and removal of form work for:
36i) Foundations,footings,bases of column
37Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth
38ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH
39Providing and laying dry brick on edge flooring in required pattern with bricks of Class designation 7.5 on a bed of 12 mm mud mortar including filling joints with river sand with common burnt clay non- modular bricks
40Providing and laying cement plaster on surfaces with Coarse sand including curing etc.
41ii) 12mm Cement plaster of mix 1:6 (1 cement: 6 coarse sand)
42Providing Neat cement punning
43CONSTRUCTION OF SALES BUILDING
44Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling & neatly dressing of disposed soil completely to be paid separately as per item no. MPLCN00600
45i) All kinds of Soil
46Extra for every additional lift of 1.5m or part thereof in excavation or banking excavated or stacked materials in all kinds of soil
47Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, within premises and lift upto 1.5m
48Supplying and filling in plinth with sand within specified grading zone of fine aggregates specified in table 3.1, clause 3.1.3 of attached specifications under floors, etc. in layers not exceeding 20cm in depth, each deposited layer to be compacted by ramming including watering, consolidating and dressing complete.
49i) Local Fine Sand within grading zone IV
50Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size). Item includes providing & mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specifications. Providing & applying a coat of residual petroleum bitumen of grade VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes & finally with a piece of cloth lightly soaked in kerosene oil
51Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level:
52v) 1:3:6(1 Cement : 3 Coarse Sand : 6 Graded stone aggregate of 20mm)
53Centering and shuttering including strutting, propping etc. and removal of form work for:
54i) Foundations,footings,bases of column
55Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level
56ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm
57Providing & Laying Reinforced cement concrete work in walls (Any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level UP TO FLOOR V LEVEL excluding cost of centering, shuttering, finishing and reinforcement :
58ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm
59Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircases above plinth level up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:2:4 (1 cement:2 coarse sand:4 graded stone aggregate 20 mm nominal size)
60Providing and laying RCC work in vertical and horizontal fins individually or forming box louvers, facias and eaves boards above plinth level up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size).
61Centering and shuttering including strutting, propping etc. and removal of form for :
62i) Foundations,footings,bases of columns, etc. for mass concrete
63v) Columns, Pillars, Piers, Abutments, Posts and Struts.
64vii) Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards
65viii) Suspended floors, roofs,landings balconies and access platform with water proof ply 12mm thick
66ix) Lintels, beams, plinth beams, girders, bressumers cantilevers and with water proof ply 12mm thick
67Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels
68ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786
69Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth
70ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH
71viii) Half brick masonry with common burnt clay F.P.S.(non modular) brick of class designation 7.5 in Cement mortar 1:4 (1 cement : 4 coarse sand) IN FOUNDATION AND PLINTH
72Providing and laying dry brick on edge flooring in required pattern with bricks of Class designation 7.5 on a bed of 12 mm mud mortar including filling joints with river sand with common burnt clay non- modular bricks
73Supplying and fixing rolling shutters of approved make, made of required size M.S. laths interlocked together through their entire length,jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS 4454 Part-I & M.S. top cover of required thickness for rolling shutters:- 80x1.25mm MS laths with1.25 mm thick top cover
74Providing & fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (minimum thickness of 5 mm) of approved make in all colours,shades except burgundy,bottle green,black of any size as approved by Engineer-in-Charge in skirting,risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade.
75Providing & laying Ceramic Glazed floor tiles 300x300 mm or more (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours White, Ivory, Grey, Fume Red Brown, laid on 20mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) jointing with grey cement slurry@ 3.3kg/sqm including pointing the joints with white cement and matching pigments etc. complete.
76Providing & laying vitrified floor tile in different sizes (thickness as per manufacturer) with water absorption's less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar as specified with coarse sand jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc. complete for flooring/skirting as specified
77i) Flooring with size of Tiles 60x60Cm in cement mortar 1:4
78Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion, Single socketed pipes.
79ii) 110 mm diameter
80Providing and laying cement plaster on surfaces with fine sand including curing etc.
81ii)12 mm cement plaster of mix 1:6 (1 cement: 6 fine sand)
82Providing and laying 6mm thick cement plaster on surfaces with fine sand including curing etc.
83i) 6mm thick plaster of mix 1:3 (1 cement: 3 fine sand)
8440mm Thick Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand:4 stone aggregate of 20mm nominal size) finished with a floating cement coat of neat including cement slurry, but excluding the cost of nosing of steps etc. complete.
85Providing and applying plaster of Paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete
86Finishing walls with Acrylic Smooth exterior paint of required shade (2 or more coat applied @ 1.67 ltr/10 sqm over & including priming coat of exterior Primer applied @ 2.20kg/10 sqm)
87Finishing walls with Deluxe Multi surface paint system for interiors & exteriors using Primer as per manufacturers specifications with two or more coats applied on wall @ 1.25 ltr/10 sqm. over and including one coat of Special primer applied @ 0.75 ltr / 10sqm
88Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture.
89Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required :
90i) White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps
91Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
92Providing and fixing toilet paper holder :
93i) C.P. brass
94Providing and fixing soil, waste and vent pipes :
95i) 100mm dia Sand cast iron S&S pipe as per IS: 1729.
96Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall
97i) 15 mm nominal outer dia Pipes
98ii) 20 mm nominal outer dia Pipes
99iii) 25 mm nominal outer dia Pipes
100v) 40 mm nominal outer dia Pipes
101Providing and fixing B class G.I. pipes complete with G.I. fittings & clamps, i/c cutting & making good the walls etc. Internal work Exposed on wall.
102ii) 20 mm nominal outer dia Pipes
103iii) 25 mm nominal outer dia Pipes
104Providing and fixing brass bib cock of approved quality :
105i) 15 mm nominal bore
106Providing and fixing brass stop cock of approved quality :
107i) 15 mm nominal bore
108Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
109i) 25 mm nominal bore
110iii) 40 mm nominal bore
111Providing and fixing first quality (heavy duty) type glazed vitreous china P or S trap Wall hung coloured water closet, seat cover, CP nuts, bolts and other necessary fittings all complete and as per specification and direction of Engineer-in-charge.
112Providing & fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :
113i) 100mm inlet & 100mm outlet SCI S&S as per IS - 3989.
114Providing and placing on terrace (at all floor levels) polyethylene water storage tank IS : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
115Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions,at top, bottom & sides with with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/panelling, C.P. brass/stainless steel screws including fixing all complete as per drawing & the directions of Engineer-in-charge. (Cost of glazing or panels to be paid for separately)
116i) Fixed Glazing with Powder coated aluminium (minimum thickness of powder coating 50 micron) sections
117iii) For shutters of doors, windows & ventilators with Powder coated aluminium sections including providing fixing hinges/ pivots & making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
118Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item):
119ii) With float glass panes of 5.0 mm thickness (weight not less than 12.5kg/sqm)
120Providing and fixing machine moulded aluminium covering of approved pattern & design, made out of machine cut aluminium sheet and machine holed for receiving dash fastener, over expansion joints on vertical surfaces/ceilings, the fixing on plate in one row on one side of joint only shall be done with stainless steel dash fasteners of 8 mm dia and 75 mm long bolt including providing aluminium washers 2 mm thick & 15 mm dia, at a staggered pitch of 200 mm centre to centre including drilling holes in the receiving surface and expandable plastic sleeves in holes etc. complete as per direction of Engineer-in-charge.
121ii) Powder coated aluminium sheet 2.5mm thick (minimum thickness of powder coating 50 micron)
122Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc. to be paid separately).
123Providing & fixing chromium plated brass 100mm mortice latch & lock with 6 levers & a pair of lever handles with necessary screws etc complete (best make of approved quality).
124Providing & fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc. complete :
125i) 250x10 mm
126ii) 200x10 mm
127Providing & fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc. complete :
128i) 125 mm
129Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 having brand logo embossed on the body/plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge.
130i) With stainless steel cover plate minimum 1.25 mm thickness
131Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick & 2100 mm long with SS screws etc. complete as per direction of Engineer-in-Charge.
132i) Powder coated minimum thickness 50 micron aluminium tubular handle bar
133i) Supplying and drawing following 2 pair 0.5 sq mm FR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
134i) 2 x 1.5 sq mm + 1 x 1.5 sq mm earth wire
135ii) 2 x 2.5 sq mm + 1 x 2.5 sq mm earth wire
136iii) 2 x 4 sq mm + 1 x 4 sq mm earth wire
137iv) 2 x 6 sq mm + 1 x 6 sq mm earth wire
138iv) 4 way (4+12) TPN
139Supply and Fixing of Discrete LED (Light Emitting Diode) Tube lights of 18 Watt, having IP65 protection class with Pressure Die Cast Aluminium housing & with Polycarbonate diffuser of approved make or equivalent as per direction of Engineer in charge. The LED shall be operating under voltage range of 140-270V with power factor more than 0.9. CCT(Correlated Colour temperature) shall be 5700 Kelvin (5665 K +/- 355 K), CRI (Colour rendering index) not less than 65. LED efficacy should be minimum 100 lumens/watt. The driver shall be of constant volt & constant current type with internal surge protection. Each lot of Fittings shall have serial numbers and accompany LM79 / IS 16106 test reports and reference/batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 72 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminarie etc.
140Supply and Fixing of Discrete LED (Light Emitting Diode) Tube lights of 8 Watt, having IP20 protection class with Pressure Die Cast Aluminium housing & with Polycarbonate diffuser of approved make or equivalent as per direction of Engineer in charge. The LED shall be operating under voltage range of 140-270V with power factor more than 0.9. CCT(Correlated Colour temperature) shall be 5700 Kelvin (5665 K +/- 355 K), CRI (Colour rendering index) not less than 65. LED efficacy should be minimum 100 lumens/watt. The driver shall be of constant volt & constant current type with internal surge protection. Each lot of Fittings shall have serial numbers & accompany LM79 / IS 16106 test reports & reference/batch nos of LEDs & fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 72 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminarie etc.
141iii) 1200 mm sweep
142ii) 9\\" dia light duty, make Khaitan or equivalent
143Supplying and fixing of MV Lightining Arrestor horn gap type as required
144Formation of lighting protection arrangement with supply of 1.0 M height spike and erection at top most portion of structure/building and connecting the same to earthpit by 40x6mm GI strip (excluding supply and laying of GI strip)
145Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
146v) 4 poles, 63A
147Providing and fixing 150 mm bright finished chrome plated brass hanging type floor door stopper with rubber cushion necessary brass screws, etc. complete. to suit shutter thickness complete
148iii) 4 module frame
149v) 8 module frame
150viii) 15 A Modular switch
151Providing and fixing factory made 30mm thick door shutter made of solid PVC foam profile. The styles & rails shall be of size 75mm x 30mm having wall thickness 5mm. The styles, top & bottom rails shall have one side wall thickness of 15mm integrally extruded on the hinge side of the profile for better screw holding power. The styles and rails shall be reinforced with MS tubes of size 33mm x 17mm x 1mm painted with primer, all four corners of reinforcement to be welded or sealed. Solid PVC extruded bidding (push fit type) will be set inside the styles and rails with a cavity to receive single piece extruded 5mm PVC sheet as panel. The styles and rails shall be mitred cut and joint with help of PVC solvent cement and self tapping screws. Single piece extruded solid PVC lock rail of size 100mm x 30mm with wall thickness 5mm & 15 mm integrally extruded in the middle of the lock rail & fixed with styles with the help of PVC solvent cement & self driven self tapping screws of size 100mm x 8mm complete as per manufacturer's specifications and direction of Engineer-in-charge
152i) Non Decorative finish
153i) All kinds of Soil
154Extra for every additional lift of 1.5m or part thereof in excavation or banking excavated or stacked materials in all kinds of soil
155x) 1:5:10(1 Cement :5 Coarse Sand : 10 Graded stone aggregate of 40mm)
156ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH
157ii) 12mm Cement plaster of mix 1:6 (1 cement: 6 coarse sand)
158ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm
159ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786
160i) Foundations,footings,bases of column
161Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, within premises and lift upto 1.5m
162i) Foundations,footings,bases of columns, etc. for mass concrete
163TANKS & PUMPS INSTALLATION
164iii) In brick masonry pit with RCC strip under driveway including RCC top slab as per standard Drg. ENG/317. Manhole cover plates and frame to be paid separately .
165iii) 15/20 KL Tank with fittings : 0 - 30 Km
166iv) 15/20 KL Tank with fittings: Add extra for each addtnl. Km above 30km
167Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete:
168ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH
169ii) 12mm Cement plaster of mix 1:6 (1 cement: 6 coarse sand)
170Supply and fixing Pressure Vacuum Valves of 2 inches for fixing to the Vent Pipes of Underground MS tanks. The valve should be in closed position at normal operating pressure of the tank. The Valve shall be capable for activation at set pressure of 3\\" ± 0.5 water column to release excess pressure of tank to the atmosphere and open at vacuum of 8\\" ± 2.0 water column to induce the atmosphere pressure to the tank. PV valve should be diaphragm of dead weight or spring loaded type or combination of any. The weight of the PV valve shall not exceed 2.0 kg. top of the valve shall be provided with cover/cap/ weather hood to prevent the entry of rain water. Valve material,Cover and adopter shall be of Aluminium/polypropylene, diaphragm if used should be of Neoprene, O ring should be of rubber/neoprene, Net/Mesh Pressure puppet ,Vacuum puppet,screws and spring should be of stainless steel. Suitable adopter with one end fitted with valve and the other end should have threading for fixing on Vent pipe of 40mm. PV valves shall have: UL 842 certification of CARB approval or test certificate from any Govt.lab. PV valve shall have PESO approval.
171vii) 1:3:6(1 Cement : 3 Fine Sand : 6 Graded stone aggregate of 40mm)
172Permanite oil packing 600 mm dia 3mm thick for tank manhole conforming to BS – 1832/58
173ii) S/L Threaded U/G HD MS Pipes of 80 mm dia with fittings,doping
174iv) S/L Threaded U/G HD MS Pipes of 40 mm dia with fittings,doping
175iv) S/L Threaded A/G HD MS Pipes of 40 mm dia with fittings,Painting
176Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture.
177Supply and Laying of 50 mm dia single wall flexible piping system comprising of Non-metallic HDPE (flexible) pipelines as per IOCL specifications and with manufacturer supplied fittings including all bends, tees, elbows, reducers, end connectors at DU & tank side etc and as required for complete underground piping job. The joints in the pipelines, except the end connections at tanks and dispensers shall be made by electro-fusion welding. The pipes shall be suitable for use with petroleum and ethanol blended fuels. The maximum operating pressure shall be 7Kg/sq.cm. Note: The make of HDPE Pipe should be CCOE approved. Pressure testing shall be done before the final backfilling. The civil works for installation viz. excavation, sand filling & back filling etc. shall be paid seperately. All metallic parts in the piping system shall be grounded as per the requirements of EN14125.
178iii) S/I Screwed type GM Ball Valve of 50 mm dia
179i) 2 product - 4 nozzle MPPs/MPDs
180ix) Mono/Duo pump/Air Comp/STP/All other pumps - (3 nos. up to 6 nos. pumps), 0-30 Km
181x) Mono/Duo pump/Air Comp./STP/All other pumps - (3 nos. up to 6 nos. pumps), Add extra for every additional Km above 30km
182Installation of Corporation supplied Standard Submersible Turbine Pump on the existing Manhole Cover as per drawing and direction of Engineer in Charge
183iv) 3 Core x 2.5 sq. mm Copper Cable FRLS
184vii) 3 Core x 2.5 sq. mm
185i) Providing dispensing pump lighting connection with copper conductor, single core PVC sheathed wire as per recommendation of the pump manufacturer (make of pumps L&T /MIDCO / AVERY /Tatsuno /Nouvopignone)
186i) S/I of 12 Volt, 7AH Charged LA battery of approved make with stand
187i) All kinds of Soil
188i) Local Fine Sand within grading zone IV
189iii) S/W Slipon flanges of 50 mm dia. conforming to IS2062 GrA, ANSI B16.5,Class 150 as per specifications and standard Drg.enclosed herein
190iii) Making Flange joint between Slip on,blind and flange etc.of 50 mm dia. including gasket, nuts, bolts,3mm dia copper wire bonding
191i) All kinds of Soil
192viii) 1:4:8(1 Cement :4 Coarse Sand :8 Graded stone aggregate of 40mm)
193ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH
194iv) Granite of any colour and shade having Area of slab over 0.50 sqm
195Supplying and fixing of 10mm thick mirror polished black granite tiles for pump island edges etc. over 12mm thick CM 1:4 including cost of all materials and labour etc. complete.
196i) Local Fine Sand within grading zone IV
197iv) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 40mm)
198Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete:
199Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture.
200YARD ILLUMINATION
201i) S/E of 7 Meter high galvanised Octagonal pole with top 70mm (A/F), bottom 130mm (A/F) made up of 3 mm thick plate having a base plate of size 220 x 220 x 12 with single arm 1500mm long bracket arm made up of 48 O.D. pipe with EN 8 grade galvanised foundation bolts and anchor plate on suitable concrete foundation as per standard drawings enclosed herein(Civil & Electrical works shall be paid separately) having fixing arrangement for mounting 2 Nos. of 250W Metal halide luminaries (on opposite sides)
202i) All kinds of Soil
203Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, within premises and lift upto 1.5m
204vii) 1:3:6(1 Cement : 3 Fine Sand : 6 Graded stone aggregate of 40mm)
205ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm
206ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786
207v) Columns, Pillars, Piers, Abutments, Posts and Struts.
208iv) 3 Core x 2.5 sq. mm Copper Cable FRLS
209i) 6mm thick plaster of mix 1:3 (1 cement: 3 fine sand)
210iii) S/E of 5 Meter high galvanised Octagonal pole with top 60mm(A/F), bottom 130mm (A/F) made up of 3 mm thick plate having a base plate of size 210 x 210 x 12 with single arm 1500mm long bracket arm made up of 48 O.D. pipe with EN 8 grade galvanised foundation bolts and anchor plate on suitable concrete foundation as per standard drawings enclosed herein(Civil & Electrical works shall be paid separately) having fixing arrangement for mounting 2 Nos. of 250W Metal halide luminaries (on opposite sides)
211i) All kinds of Soil
212Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, within premises and lift upto 1.5m
213vii) 1:3:6(1 Cement : 3 Fine Sand : 6 Graded stone aggregate of 40mm)
214ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm
215ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786
216v) Columns, Pillars, Piers, Abutments, Posts and Struts.
217iv) 3 Core x 2.5 sq. mm Copper Cable FRLS
218ii) 16mm dia x 400mm long with 75 mm dia x 5 mm thick plate
219Supply and fixing of 100 W LED (Light Emitting Diode) light fixture with fittings and accessories for Yard lighting purpose having IP66 protection class with Pressure Die Cast LM6/ADC12/LM24 housing and with toughened glass or UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer-in-charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour temperature) shall be in the range of 5665 K +/- 355 K as per ANSI standard C78.377, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 70 for outdoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 100 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 3kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/ batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of minimum 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc.
220i) 6mm thick plaster of mix 1:3 (1 cement: 3 fine sand)
221HOARDING
222i) All kinds of Soil
223iv) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 40mm)
224i) Foundations,footings,bases of column
225i) Hot finished welded type tubes
226Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete:
227Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture.
228i) 2 Core x 1.5 sq. mm. (copper)
229Supply & fixing of flame proof junction box (4 way entry) of BALIGA /CEAG-FCG/FLEXPRO/FEPL make including clamping arrangement, all complete as per specification and direction of Engineer In-charge.
230i) 2 Core x 1.5 sq. mm
231v) 25 x 3 mm GI strip
232ii) Upto 32A DP MCB
233Supply and fixing of 30 W LED (Light Emitting Diode) light fixture with fittings and accessories for hoarding light purposes having IP65 protection class with Pressure Die Cast LM6/ADC12/LM24 housing and with toughened glass or UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer-in-charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour temperature) shall be in the range of 5665 K +/- 355 K as per ANSI standard C78.377, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 70 for outdoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 100 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 3kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/ batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of minimum 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc.
234AIR FACILITY
235iii) Horizontal air compressor Assembly of 5 HP (160-220 LITRES) including civil works
236i) 15 mm dia. nominal bore
237v) 4 Core x 2.5 sq. mm Copper Cable FRLS
238Tyre Inflator Supply & installation of Digital tyre inflator which is microprocessor based, automatic air pressure controller with solenoid controlled nozzle for automatic fill and release functions. Complete with weather proof cabinet, 3 digit LED displays with backlight illuminations i.e. one for actual tyre pressure and another for set pressure. Air filter, remote controller, cables, PVC hose pipe and working pressure upto 10bar (Excluding civil work for foundation,etc.)
239iii) 3 Core x 1.5 sq. mm. (copper)
240vi) 3 Core x 1.5 sq. mm.
241xi) 4 Core x 2.5 sq. mm
242Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete:
243viii) 1:4:8(1 Cement :4 Coarse Sand :8 Graded stone aggregate of 40mm)
244iv) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 40mm)
245Supplying and fixing of 10mm thick mirror polished black granite tiles for pump island edges etc. over 12mm thick CM 1:4 including cost of all materials and labour etc. complete.
246Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture.
247Supply and Fixing of Discrete LED (Light Emitting Diode) Tube lights of 18 Watt, having IP65 protection class with Pressure Die Cast Aluminium housing & with Polycarbonate diffuser of approved make or equivalent as per direction of Engineer in charge. The LED shall be operating under voltage range of 140-270V with power factor more than 0.9. CCT(Correlated Colour temperature) shall be 5700 Kelvin (5665 K +/- 355 K), CRI (Colour rendering index) not less than 65. LED efficacy should be minimum 100 lumens/watt. The driver shall be of constant volt & constant current type with internal surge protection. Each lot of Fittings shall have serial numbers and accompany LM79 / IS 16106 test reports and reference/batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 72 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminarie etc.
248ii) 2 x 2.5 sq mm + 1 x 2.5 sq mm earth wire
249i) for 2.5 sq.mm. cable entry size with 9 terminals
250ii) Powder coated aluminium sheet 2.5mm thick (minimum thickness of powder coating 50 micron)
251ELECTRICAL WORKS
252Medium RO, Standard drawing No. ENG/IOCL/PDIL-2. List of Componets are: (a) 1 No. MCCB (3P+N) of 100 A, 35 KA with O/L, E/F & S/C Releases for incomer from Electricity Board (b) AC Digital Voltmeter (0-500V) with built in selector switch for incomer from Electricty Board (c) AC Digital Ammeter (0-100A) with built in selector switch for incomer from Electricity Board (d) 1 No. FP, On Load, 100 A, Manually Operated Change over switch suitable for connection of Mains supply and 30 KVA DG Set /5 KW Solar system with required No. of MCCB (100 A,35 KA,3P+N) for change over between Mains supply and DG Set /Solar Supply along with 2 Nos 6A , SP, Control MCB with Indicating lamps. (e) 1 No. MCCB (3P+N) of 100A, 35 KA with UV coil O/L , E/F & S/C Releases for incomer from Electricity Board/DG Set/Solar Supply & 1 No 6A , SP, Control MCB with 3 Nos LED Type (RYB) Indicating lamps (f) 3 Nos 100/5 A CL1 10VA Current Transformers ; PT (50 VA) along with 2 A control fuse link and 1 No. 6A , SP, Control MCB (g) 1 No DP MCB of 40 A, 10 KA for supply of essential loads (h) 1 No Single Phase Contactor(3NO+3NC) for supply to essential loads (i) 1 No MCB DB Hosuing 6 Nos , 16 A, 10 KA DP MCB as outgoings for essential loads (j) 415 V, TP & N, 125 A, Al Bus Bar (k) 4 Nos MCB (3P+N) of 40 A,10 KA for supply of outgoing feeders 1-4 (l) 9 Nos DP MCB of 10 A, 10 KA in Outgoing Feeder -1 (m) 6 Nos DP MCB of 16 A, 10 KA & 3 Nos DP MCB of 20 A, 10 KA in outgoing Feeder-2 (n) 3 Nos DP MCB of 16 A, 10 KA & 6 Nos DP MCB of 20 A, 10 KA in outgoing Feeder-3 (o) 8 Nos TP MCB of 16 A, 10 KA & 1 Nos TP MCB of 25 A, 10 KA in outgoing Feeder-4 (p) Provision for Termination of Solar Power (Up to 10 KW) Incomer to Essential DB in Panel as per requirement of IOCL.
253vii) 3 Core x 2.5 sq. mm
254xvii) 3.5 Core x 35 sq. mm
255xix) 3.5 Core x 70 sq. mm Aluminium Cable FRLS
256i) Electrical insulating mats made of PVC Elastomer 3mm Thick & 1 mtr wide near swichboards, etc as per direction of Engineer In charge. Mat should conform to IS 15652 Class A - suitable for safe working voltage of upto 33 kV. Test certificate to be provided with supply. Mat's top Surface should be Antiskid Dotted & Bottom Surface should be Textured for Floor Grip. Mat's top Surface should be Antiskid Dotted & Bottom Surface should be Textured for Floor Grip.
257iii) Supply and fixing of shock treatment chart in English, Hindi & local language framed in glass framework.
258Supply and Installation of Flame Proof ESD Push Button
259iv) 3 Core x 2.5 sq. mm Copper Cable FRLS
260iv) 5KVA stabilizer
261iii) 500VA CVT
262Chemical Earthing with Copper Bonded Rod suitable for current carrying capacity of 15kA for 1 second - Supply of chemical earthing Cu Bonded High Tensile Low Carbon Steel Rod of dia not less than 17mm electrode complying to UL 467 Requirements & suitable for current carrying capacity of 15kA for 1 second, exothermic welded & 3Mtr long
263iii) 50 x 6 mm G.I. Strip
264ii) 32 x 6 mm G.I.strip
265v) 25 x 3 mm GI strip
266Excavating trenches of required width for pipes, cables etc including excavation for sockets & dressing of sides, ramming of bottoms,depth upto 1.5m including taking out excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing surplus excavated soil as directed, within or outside site at unobjectionable place in all kinds of soil
267iv) Pipes, Cable etc. > 80mm < 300m dia
268Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level:
269vii) 1:3:6(1 Cement : 3 Fine Sand : 6 Graded stone aggregate of 40mm)
270Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level:
271iv) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 40mm)
272Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level
273ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm
274Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth
275xiii) Brick work with class designation 5.0 bricks in cement mortar 1:4 (1 cement : 4 coarse sand) IN FOUNDATION AND PLINTH
276Providing and laying cement plaster on surfaces with fine sand including curing etc.
277ii)12 mm cement plaster of mix 1:6 (1 cement: 6 fine sand)
278Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels
279ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786
280Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : Light Duty
281ii) 150 mm dia. R.C.C. pipe Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58301985
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 89.83 Lakhs
LAST DATE 07-11-2026
Authority
Authority Name Indian Oil Corporation Limited
Work Description Tender for Development Of New A Site Ro At Batadraba Than Gate To Christ Jyoti School On Sh 47, District - Nagaon, State: Assam Under Guwahati Divisional Office Of Indianoil Aod State Office
Basic Detail
Tender No ER-MnC/2026-27/LT/409
Bidding Type Tender
Location
City Nagaon
State Assam
Key Dates
Publish Date 31 Oct 2026
Submission Date 07 Nov 2026
Open Date 09 Nov 2026
Finance
Tender Value 89.83 Lakhs
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Not Available
Document List
7093a525-f8d2-4ce1-a636-5ec7e94e82da.html
BOQ_202281.xls
DrgPart1.pdf
DrgPart2.pdf
FAQs-IOCL-Online-EMD.pdf
Special_Instructions_to_t_1.pdf
Techspec.rar
Tender-Acceptance-Format.pdf
Tenderdocument.rar
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 31, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Nov 09, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
html

7093a525-f8d2-4ce1-a636-5ec7e94e82da.html

xls

BOQ_202281.xls

pdf

DrgPart1.pdf

pdf

DrgPart2.pdf

pdf

FAQs-IOCL-Online-EMD.pdf

pdf

Special_Instructions_to_t_1.pdf

rar

Techspec.rar

pdf

Tender-Acceptance-Format.pdf

rar

Tenderdocument.rar

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender