Tender For Repair/Maint Of B/R And E/M Items, Redressal Of Day To Day Complaints In Md/Otm Accn Bldgs At Hebbal Under Ge (South) Bangalore
Tender Value
32.75 Lakhs
Estimated cost
Bid Submission
21 Nov 2026
8 days left
EMD
65500
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Bengaluru Urban → Karnataka
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Maint Of B/R And E/M Items, Redressal Of Day To Day Complaints In Md/Otm Accn Bldgs At Hebbal Under Ge (South) Bangalore
BOQ
| Sl. No. | Item Description |
| 1 | Taking down shutters of any description exc 1 Sqm but not exc 2 Sqm and Re-fixing in same opening complete all as specified and directed |
| 2 | Resecuring or easing & adjusting without taking down shutters of any description exc 1 sqm but n.exc 2 sqm each complete all as specified and directed |
| 3 | Taking down chowkat (without taking of shutter from the frame) not exc 1.5 sqm each including making good the disturbed surface in PCC 1:2:4 type BO or CM 1:3 all as specified and directed |
| 4 | All as per Item No 3 above, but exc 1.50 sqm and not exc 4.00 sqm each |
| 5 | Taking down shutters of any description exc 1 Sqm but not exc 2 Sqm each all as specified and as directed |
| 6 | Solid PVC door frame (Single rebated) of size 60 mm x 30 mm made out of solid foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100x8 sheet metal CSK screws complete all as specified and as shown on drawing.Note :- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life) complete all as specified and directed |
| 7 | M & L for Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing with wood free EPS . |
| 8 | S&F 2nd class hard wood plain, solid, straight chowkats and frames, clean sawn, frame rebeated on the solid , rounded or chamfered, put together with glue pinned at joints etc complete all as specified and as directed |
| 9 | Pressed steel frames made of 1.25mm thick MS sheet of profile 105x60mm x for door and window frames with one internal lock strike plate, shock absorber, 20mm dia 60mm long MS conduit for housing of a drop bolt, treating of internal surfaces of chowkhats with coal tar or black paint including hinges, hold fasts/lugs etc complete all as specified |
| 10 | All as above here-in-before but size 125x60mm with double rebate. |
| 11 | S&F 40 mm thick laminated flush shutters, solid core construction, with block board core and plywood face panels, lamination both sides with decorative face veneer with lipping/frame to match complete all as specified and as directed. |
| 12 | S&F 35mm thick BRAND FACTORY MADE WIRE MESH SOLID WPC Pre-laminated both side DOOR SHUTTER in Singal Piece consisting of Density 650 Kg /Cm Manufactured by an ISO-9001-2015 certified Company. Door to be panelled with SS mosquito Mesh and XTN aluminium Mesh for additional strength and safety purpose. (confirming as per S:4020). The door should be water proof, termite proof, fire retardant and having screw holding capacity. Door to be fixed to frame with 3 nos. M.S powder coated butt hinges size 100mmx25mmx2mm and 32mm long steel screws drilled suitable to pass through both the walls of the M.S tube. Other hardwares should be fixed with 19x6mm size steel screws etc. Complete as per direction of Engineer-in-charge, manufacturer's specification & drawings complete all as specified and directed. |
| 13 | S&F Plain framed, panelled shutter (two panel) of 35mm thick with lock rail and panel of 9mm BWP commercial ply or 12mm veneered Particle board with commercial veneering on both faces. rail and style are of 2nd class hardwood & The size of rail and stile as per IS:1003 (Part-I), kiln seasoned and chemically pressure treated fixed to chowkhat all as specified and as directed. |
| 14 | S&F for mild steel work as in hold fast made in flat iron all as specified |
| 15 | M & L for powder coated (minimum thickness of powder coating 50 micron) aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified |
| 16 | M & L Powder coated aluminium (minimum thickness of Powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium section shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P. brass/stainless steel screws all complete as per architectural drawings and the directions.Note: Sheet glass or wire mesh be measured and paid separately. |
| 17 | M & L for powder coated aluminium grill (powder coated or dyed to required shade according to IS:1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement all as specified and as direction. |
| 18 | S&F Box type Steel Windows/Ventilators double side shutters (Windows side hung type, Ventilators top hung) pressed steel frames made out CRC Sheet of 80x60x1.25mm double rebated, Shutters box type made out of CRC Sheet 40x20x1.0mm, windows & ventilator shutter fixed made of glass and gauge fixed with box type hinges, Aluminium cast handles for glass shutters, iron flat type handles for mesh shutters, Telescopic stays, etc complete all as specified incl 12mm square guard bars/grill welded with steel frame (100c/c horizontally) all as specified and directed by Engineer-in-Charge. NOTE: (i) Payment under this item will be make combined for steel frames, shutter. Unit rate shall deemed to include cost of beading, fittings such as handles, hinges, Telescopic stays, locking arrangements and fixing of glass and wiremesh etc. (ii) Note: Supply & fixing of 4 mm thick sheet glass or wire mesh be measured and paid separately. (iii) Weight of Grill/Guard Bars, handle hinges and etc. |
| 19 | M & L for plain cement concrete for filling of steel door frame/box type steel window/vent type C0, 1:3:6 using 12.5mm grade stone aggregate. |
| 20 | Supply & fix Sheet glass 4mm thick ordinary quality and glazing with oil putty or in wooden/steel aluminium/rubber beading in square not exceeding 0.5 Sqm in each pane and all as specified |
| 21 | - ditto- buit exc 0.5 Sqm in each pane |
| 22 | Supply & fix stainless steel wire cloth 0.36mm nominal dia and average width of aperture 1.40mm fixed with glazing clips etc complete all as specified and directed |
| 23 | Dismantling of structural steel work including doors, gates but excluding framed truss etc all as specified. |
| 24 | S&F framed work as in doors or gates of angle or other sections with gusset plates, rail braces, etc complete drilled for fixing of steel sheeting or other covering, doors etc, to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings(exclusive of steel sheeting or other covering, running rails and guides) and hanging ; also fastening and fixing complete including painted with one shop coat of zinc chromate primer paint (including preparation of surface) at contractors workshop/factory before fabrication complete all as specified and directed |
| 25 | S & F of 1.25 mm thick Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, turned down or turning up, mitred angles, etc. as required |
| 26 | M&L preparing new wooden surface of any description, not other wise described over 10 cm width or girth and applying two coats of synthetic paint over a coat of pink primer etc all as specified and as directed |
| 27 | M & L applying two coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces over 10 cm width or girth including preparation of new steel surfaces |
| 28 | S & F Butt hinges stainless steel 100mm long and fixed to door frame and shutter duly welded/screwed complete all as specified and as directed |
| 29 | S&F stainlees steel 150mm tower bolt with stainless steel screws all as specified and as directed. |
| 30 | S&F stainlees steel 150mm door handles with stainless steel screws all as specified and as directed. |
| 31 | S&F stainlees steel 250mm sliding door bolt with stainless steel screws all as specified and as directed. |
| 32 | S & F 140 mm floor door stopper of aluminium alloy powder coated, with hard down steel spring all as specified and as directed |
| 33 | S&F Mild steel 300mm, ordinary rat tail rod pattern springs, including roller and roller plate complete |
| 34 | S&F Rubber door buffer 125mm size fixed with brass screws complete all as specified and directed |
| 35 | M & L 4 mm thick figured glass, pin head type and glazing with oil putty/wooden or steel beading in squares n.exc 0.5 Sqm in each pane all as specified and as directed. incl. Hacking out old broken glass of any thickness, size, quality or description from metal frame including punching or drilling out old glazing pins/spring clips etc complete all as specified |
| 36 | M&L for 3mm thick Sheet glass, ordinary quality and glazing with oil putty / wooden or steel beading in squares n.exc 0.5 sqm in each pane all as specified and as directed. incl Hacking out old broken glass of any thickness, size, quality or description from metal frame including punching or drilling out old glazing pins/spring clips etc complete all as specified and as directed. |
| 37 | M & L for Running welding in repairs thickness of metal to be welded N exc 6 mm thick complete all as specified and as directed. |
| 38 | S & F in repairs stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm fixed with MS screw or nut bolts with or without wooden or steel beading in repairs all as specified and as directed. |
| 39 | S&F in repairs mild steel 300mm, ordinary rat tail rod pattern springs,including roller and roller plate complete all as specified and as directed. |
| 40 | S&F in repair 18/19 thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work |
| 41 | M&L for Plain tiles Square, rectangular or triangular in section clean sawn, secured with nails or brads of second class hardwood, fixed to cupboard shutter including taking down old fillets exc 6 & n exc 13 sqm cross section area all as specified and directed. |
| 42 | S&F Continuous (piano) hinges 30mm width of flaps (when open), mild steel, bright finish or electro galvanised |
| 43 | S&F magnet door catcher made of stainless steel complete all as specified and as directed |
| 44 | S&F Non asbestos fibre cement building boards including anodised aluminium snap grid frame work of size of grid 605 x 600mm for false ceiling, fixed on aluminium framework with screws including taking down old ceiling or any description, complete all as specified and directed. |
| 45 | S&F in repairs Stainless steel polished curtain rod medium weight 25mm dia with and including support wall bracket of and end knobs of polished stainless steel all as specified. |
| 46 | S&F Stainless steel polished wall brackets for holding curtain rod medium weight all as specified. |
| 47 | S&F in repairs Stainless steel polished end knobs spherical in shape suitable for 25mm rodall as specified. |
| 48 | S&F Pre-painted aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling of sheet of any type and any thickness complete all as specified and directed. |
| 49 | M & L for 20 mm thick Granite (of any type) (work table rubbed and polished) in steps, jambs, pillars, window sills, cooking platforms and like in cement mortar (1:4) including pointing with admixture of pigment to match with shade of granite including cutting and polishing laid on 15mm thick screed bed in CM 1:4 set and jointed including dismantling of old stone slab complete all as specified. |
| 50 | M & L for Providing edge moulding to 18-20mm thick granite stone any description of counters vanities etc. including machine polishing to edge to give high gloss finish complete all as specified and directed |
| 51 | S&F in repair sink made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar or on dwarf wall including cantilever brackets and connecting union to pipe, overall size 495mm x 420mm and bowl size 410mmx330mmx 160mm complete |
| 52 | S&F assembled ready to use stainless steel grade 304, kitchen plate rack inlcuding top/middle shelves of 1.0mm thick sheet, square hollow supports, including bottom hooks, spoon holes, front and back open, size 915x915mm as approved and specified. |
| 53 | Opening air lock/blockage in GI / CPVC pipe line of any dia from outlet of water tank to all internal GI/CPVC pipes/fittings to smooth flow or water from bib taps/showers/WHB pillar tap/stop valve/mixers complete by air pressure/water gravity pressure all as specified and directed. |
| 54 | S&F in repairs brass spindle of any type with nylone washer and removing leakage of water of any tap/stop valve/angle cock/pillar cock/wall / sink mixer suitable for 15mm bore pipe complete all as specified |
| 55 | S&F in repair vitreous China wash basin, pedestal type, 550x400mm with brass waste coupling and brackets including cutting for and pinning in ends of brackets or seating stand complete. |
| 56 | S&F in repair vitreous china wash down water closet pan (pedestal pattern) white, including flushing cistern and flush pipe, including connection to drain or out going pipe) and flushing pipe, syphonage pipe, seat and cover for pedestal pan including PVC flushing cistern and 450 mm long PVC connection etc. |
| 57 | S&F in repair Vitreous china wash down water closet pan one piece close seat cover white, oval shape or Reach shape complete all as specified and as directed |
| 58 | MC&L for chain flushing pan, Orissa pattern, size 580 x 440 mm, with integral foot rests including PVC SWR trap 110 mm dia to fix PVC flushing cistern 600 mm long PVC connections connecting to and to any syphonage pipe etc. complete including making good to floor, fixed in repairs complete all as specified and directed |
| 59 | S&F in repairs 10 ltrs capacity PVC valveless syphonic action flushing cistern low level with inlet ball valve, flush pipe or siphonage of low or high density or PVC 32mm dia complete all as specified and directed |
| 60 | Supply & laying 20 mm outer dia CPVC pipes SDR 11 (Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including all fittings and specials including taking down 15 mm GI tubing and connections complete all as specified |
| 61 | Supply & laying 25 mm outer dia CPVC pipes SDR 11 (Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including all fittings and specials including taking down 20 mm GI tubing and connections complete all as specified |
| 62 | S&F wash basin Brass CP mixer for mixing hot & cold water screwed down for iron pipe 15 mm and fixed in repairs |
| 63 | S&F in repairs Brass CP wall mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed. |
| 64 | S&F in repairs 15mm bore CP pillar taps, fancy type, cast copper alloy with capstan heads, screwed down high pressure, with or without lettered \\"Hot\\" or \\"Cold\\" with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed |
| 65 | S&F 15mm stop valves/ angle valves cast copper alloy, screwed down, high pressure, fancy type chromium plated screwed both ends for iron pipe or for unions and fixed in repairs. |
| 66 | S&F two way bib cock with angle valve combination brass chromium plated, fixed in repairs. |
| 67 | S&F 15mm stop valves cast copper alloy, screwed down, high pressure, fancy type, chromium plated with long shank and cup (concealed type) screwed both ends for iron pipe or for unions and fixed in repairs |
| 68 | S & F chromium plated long body bib tap 15mm dia with CP flange as fixed in repair all as specified and as directed. |
| 69 | S&F bib tap 15mm, standard of CP fancy type, chromium plated any colour high pressure screwed for iron pipe and fixed in repair. |
| 70 | S & F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position including taking down old complete in all respect as specified. |
| 71 | S & F in repair chromium plated heavy duty health faucet with 1.25m long braided pipe complete in all respect as specified. |
| 72 | S & F in repairs Towel rail stainless steel glossy finish complete all as specified and as directed. |
| 73 | S&F 125mm dia brass chromium plated shower rose with swivel joints fixed in repairs |
| 74 | S&F in repairs Soap dish chromium plated brass all as fixed in wall as per manufacturers instruction. |
| 75 | S & F in repairs Toilet paper holder with flat recessed type stainless steel Complete all as specified and directed. |
| 76 | S & F in repairs 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup |
| 77 | S&F in repairs PVC Mirror cabinet of size 300X450mm complete all as specified and as directed. |
| 78 | S&F in repairs PVC Connection (Suitable for Cold Water Supply) 15 mm size with PTMT nuts of length 450 mm, all as specified and as directed. |
| 79 | S&F in repair PVC Connection (Suitable for HOT Water Supply) 15 mm size with PTMT nuts of length 450 mm, all as specified and as directed. |
| 80 | M&L 32 mm dia waste fittings brass, chromium plated for sinks etc with long screwed shanks and flynuts, flange and fixed in repair complete all as specified and as directed |
| 81 | M&L in repairs PVC urinal waste pipe 32mm dia 800mm long complete all as specified and directed |
| 82 | S&F in repair 15mm dia Bib tap PTMT fancy type any colour screwed for iron pipe and fixed |
| 83 | S&F in repair 15mm dia Pillar tap PTMT fancy type any colour screwed, for iron pipe and fixed |
| 84 | S & F PVC sintex tank cover suitable for 500/1000 litre capacity water tank complete as in repairs |
| 85 | S&F in repair plastic water closet seat cover for western & indo western pedestal pan closed pattern with flat bottom, and cover and mid steel chromium plated or aluminium hinging device fixed complete all as specified and directed. |
| 86 | Petty repairs to leaking water in bib taps, pillar taps, stop cock , angle valve, PVC connection waste pipes, float valves, concealed stop cock GI pipe joints bottle traps etc of any description by changing the washers etc or any other minor accessories to make the system functional complete all as specified and directed |
| 87 | Petty repairs to high/low level flushing cistern by adjusting the float valve, leakage of PVC connection, PVC/GI bend replacing of rubber washer check nuts plugs etc for any type of flushing cistern complete all as specified and directed |
| 88 | M & L for 500 litres capacity rotational moulded, triple layer polythene water storage tanks (cylindrical vertical with closed top) hoisting and fixed in position on roofs including 20 mm dia ball valve and fittings including dismantling existing water storage tank, complete all as specified. |
| 89 | M & L for 1000 litres capacity rotational moulded, triple layer polythene water storage tanks (cylindrical vertical with closed top) hoisting and fixed in position on roofs including 25 mm dia ball valve and fittings including dismantling existing water storage tank, complete all as specified. |
| 90 | S & F in repairs 25 mm dia of bore ball float valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe complete all as specified and as directed [Minimum weight for 20 mm – 210 gms]. |
| 91 | S & F in repairs 20 mm dia of bore ball float valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe complete all as specified and as directed [Minimum weight for 20 mm – 210 gms]. |
| 92 | Dismantling of floor, hearth or wall tilling incl cement mortar bedding (but not backing) and removing rubbish off from premises. |
| 93 | Demolition of cement concrete and paving not exc 15 cm thick (below or above ground level) complete all as specified and as directed. |
| 94 | M&L Non Skid ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and incl Screed bed or bedding layer of mortar 15 mm thick in CM 1:4 for laying floor finishes all as specified and as directed. |
| 95 | M&L Non Skid ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and incl Screed bed or bedding layer of mortar 15 mm thick in CM 1:4 for laying floor finishes all as specified and as directed. |
| 96 | M & L Glazed ceramic tiles in vertical surfaces 450 x 350 x 7 mm / 300x450x7 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface and grouted with epoxy grout 10mm thick in screed CM 1:4 on brick work or concrete surfaces to receive wall tiles all as specified and as directed. |
| 97 | M & L cement concrete type BO, 1:2:4 (12.5 mm graded agg) 25mm thick finished even as in levelling concrete for floor. |
| 98 | Renewing Glazed tiles/non-skid tiles in patches, area n exc 0.5 sq.m. including removing and cleaning old tiles, preparing beds and laying or setting, jointing and pointing new or old tiles complete |
| 99 | Demolition of brick/stone/boulder/precast concrete articles and precast concrete block built in cement mortar etc complete all as specified. |
| 100 | M&L for Pre-cast cement concrete block masonry, type C1 1:3:6(using 20mm graded aggregate) in CM 1:6 with solid blocks, exc 10cm in width and setting in mortar, complete. |
| 101 | Taking down cement plaster of any description including racking out joints, hacking for key and disposal of debris to out side MD land all as specified and as directed. |
| 102 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished plastered surface even and smooth without using extra cement |
| 103 | M&L for rendering 15 mm thick on other than fair faces of brick work or concrete surfaces in cement mortar 1:4 with WPC, finished plastered surface even and smooth without using extra cement. Note :- WPC will be measured and paid separately |
| 104 | Supply only liquid water proofing compound |
| 105 | M&L for rendering 5 mm thick on ceiling / RCC surfaces in cement mortar 1:3, finished plastered surface even and smooth without using extra cement |
| 106 | M&L Preparation of newly plastered surfaces and applying two coat of oil bound distemper over a coat of alkali resistant primer over two coats of wall care putty complete all as specified and directed |
| 107 | M & L preparation of newly plastered surface of wall and applying two coats of cement base paint Complete all as specified and as directed. |
| 108 | M & L for preparing newly plastered ceiling surfaces and applying three coat of white wash complete all as specified & as directed. |
| 109 | S & F in repair 75mm dia PVC(SWR) floor trap, plain with grating including jointing with sivent cement all as specified and as directed. |
| 110 | S & F in repair grating doom 100 mm dia of PTMT complete all as specified and as directed |
| 111 | S & F in repair 75 mm dia bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls including necessary fittings all as specified and as directed. |
| 112 | Ditto all as above but 110 mm dia. |
| 113 | S&F in repair 75mm dia PVC (SWR) Bends with access door of any radious |
| 114 | Ditto all as above but 110mm dia |
| 115 | S&F in repair 75mm dia PVC (SWR) junction single(single T) equal or unequal with access door |
| 116 | Ditto all as above but 110mm dia |
| 117 | S&F in repair 110mm dia PVC(SWR) brach piece, single(single Y) equal or un equal with access door |
| 118 | Ditto all as above but 75mm dia |
| 119 | S&F in repair 110mm dia PVC(SWR) brach piece,(double Y) equal or un equal with access door |
| 120 | Ditto all as above but 75mm dia |
| 121 | S&F in repair 75mm dia PVC(SWR) vent cow |
| 122 | Ditto all as above but 110mm dia |
| 123 | S&F in repairs Vitreous China bowl type urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe ) but including Concussive push button taps of cast copper alloy, screwed for iron pipe, PTMT waste coupling suitable for urinals, (Minimum weight 32mm-45 gms urinal spreader PVC connection and PVC urinal waste pipe complete all as specified and as directed. |
| 124 | Preparation of old decorated surfaces and applying one coat of white wash on walls including in narrow widths/ bands etc complete all specified and as directed. |
| 125 | Preparation of old decorated surfaces and applying two coats of white wash on walls including in narrow widths/ bands etc complete all specified and as directed. |
| 126 | Preparation of old decorated surfaces and applying one coat of white wash on ceilings including in narrow widths/ bands etc complete all specified and as directed. |
| 127 | Preparation of old painted surface and applying one coat of synthetic enamel paint on steel and iron surfaces over 10cm width or girth all as specified and as directed. |
| 128 | Preparation of old painted surfaces and applying one coat of synthetic enamel paint on wood and wood based surfaces over 10cm width or girth all as specified and as directed. |
| 129 | Preparation of old decorated surfaces including washing, rubbing down and stopping and applying one coat of oil emulsion distemper on walls all as specified and directed. |
| 130 | Preparation of old decorated surfaces including washing, rubbing down and stopping and applying two coats of oil emulsion distemper on walls including necessary putty all as specified and directed. |
| 131 | M & L for Complete removal of existing treatment on walls of any description over 10cm girth or width and applying two coats of oil emulsion distemper over one coat of alkali resistant primer over one coat of chalk whiting putty on plastered surfaces of walls including in narrow widths/ bands etc complete all specified and as directed. |
| 132 | Preparation of old decorated surfaces including washing, rubbing down and stopping and applying one coat of oil emulsion distemper on Ceiling all as specified and directed. |
| 133 | Preparation of old surfaces including brooming down with steel wire brushing scrapping down soot's, moulds, moss and efflorescence, salts ,treating oil and greasy spots etc and applying one coat of cement base paint at any position. |
| 134 | Preparation of old surfaces including brooming down with steel wire brushing scrapping down soot's, moulds, moss and efflorescence, salts ,treating oil and greasy spots etc and applying two coats of cement base paint at any position. |
| 135 | Material and labour for cleaning of PVC/RCC over head water tanks at any height (on accessible/inaccessible roofs) by high pressure water jet of pressure not less than 120 PSI for removing all scale, dirt, mud, any foreign material, accumulated silt, other dirty substance, algae, fungus and any bacterial material from sides/bottom of tank, cleaning shall be done by draining / pumping out water / sludge from tank, by high pressure water jet of pressure not less than 120 PSI for removing clogged mud/scales etc and cleaning the same again with self priming pumped fresh water and disinfecting the water tank by using UV radiator and approved chemical (chlorite), after cleaning writing letter / figures (Date of cleaning and next Date of cleaning) on black back ground with white synthetic enamel paint including removing the existing letters/ figures complete all as specified and as directed for capacity of water tank exc 250 & n. exc 500 lit capacity. |
| 136 | All as per Item No 158 above, but Exc 500 litre N.exc 1000 ltr capacity |
| 137 | Taking down carefully aluminium/ copper wiring/power point wiring (light, fan, socket or power) complete including fittings such as switches ceiling roses, regulators, sockets , light fittings, fans etc and making good the disturbed surface of walls, ceiling etc incl painting with same colour of the back ground complete all as specified and as directed by Engineer-in-Charge. |
| 138 | Wiring complete concealed with 1.5 Sqmm single core PVC insulated sheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl non-metalic rigid PVC conduit medium grade ISI marked incl accessories concelaed type wiring incl GI/ MS branded sunken boxes suitable for normal/modular concealed on walls including plastic/heylam laminated sheet top cover 3 mm thick/modular frame and cover of suitable module fixed with cadmium plated iron screws for housing modular/normal type switches, switch socket outlets, fan regulators etc., incl provision of 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.for the following :- (a) One light point controlled by one switch |
| 139 | (b) One fan point controlled by one switch/regulator |
| 140 | (c) One light point controlled by 2 way switch |
| 141 | (d) One 3 pin socket out let 5 Amps on independent board |
| 142 | (e) one bell/buzzer point controlled by bell push |
| 143 | (f) one 3 pin socket out let 5 A on same board |
| 144 | All as per item No 138.01 above but concealed wiring drawn through existing PVC conduit.(a) One light point controlled by one switch |
| 145 | (b) One fan/Exhaust point controlled by one switch/regulator |
| 146 | (c) One light point controlled by 2 way switch |
| 147 | (d) One 3 pin socket out let 5 Amps on independent board |
| 148 | (e) One bell/buzzer point controlled by bell push |
| 149 | (f) One 3 pin socket out let 5 A on same board |
| 150 | Wiring complete with 2.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through non-metalic existing PVC conduit medium density ISI marked incl accessories surface type run on walls/ ceiling incl MS terminal boxes fabricated with 1.6 mm thick GI/MS sheet surface mounted/ concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 2.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed. |
| 151 | Wiring complete with 1.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl PVC Casing & Caping ISI marked incl accessories surface type wiring incl 1.6 mm thick GI/MS sunken boxes concealed on walls including laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.for the following: (a) One light point controlled by one switch |
| 152 | (b) One fan point controlled by one switch/regulator |
| 153 | (c) One light point controlled by 2 way switch |
| 154 | (d) One 3 pin socket out let 5 Amps on independent board |
| 155 | (e) one bell/buzzer point controlled by bell push |
| 156 | (f) one 3 pin socket out let 5 A on same board |
| 157 | Wiring complete with 2.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl non-metalic PVC conduit medium density ISI marked incl accessories concealed type run on walls/ ceiling incl GI/MS terminal boxes fabricated with 1.6 mm thick MS sheet concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 2.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed. |
| 158 | Wiring complete with 2.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl PVC casing caping ISI marked incl incl accessories surface type wiring run on walls/ ceiling incl GI/MS terminal boxes fabricated with 1.6 mm thick MS sheet concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 2.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.Note for Item No 138.01 to 143.00 :-(i) The earth wire for the points in the same circuit can be looped from point to point. (ii) Earth wire shall be taken inside the conduit. (iii) Cost of terminal box is deemed to be included in the item rate quoted for point wiring. (iv) Cost of a circuit of any length of cable from DB to any switch/ socket board to be included in point wiring. (v) Cost of cutting chases for conduits and making good to walls, in case of recessed or concealed conduit wiring will be included in unit rate quated . |
| 159 | M&L for groove cutting in wall/floor and making good of distrubed wall/floor, painting of existing colour all as specified and directed by Engineer -in-Charge. |
| 160 | S&F in repair LED batten suitable for indoor applications 20 Watts, 4 feet with extruded aluminium housing & integrated LED channel complete with all accessories including taking out old fittings all as specified and directed. |
| 161 | S&F in repair LED batten suitable for indoor applications 10 Watts, 2 feet with polycarbonate housing & integrated LED channel with white arcylic cover complete with all accessories including taking out old fittings all as specified and directed. |
| 162 | S&F in repair 2 x 2 Recess mounted LED Luminaire 36 Watts white powder coated CRCA housing with LEDs seamless front frame with flate white high transmission arcylic cover complete with all accessories all including taking out old fittings as specified and directed. |
| 163 | S&F in repair 2 x 2 Surface mounted LED Luminaire 36 Watts white powder coated CRCA housing with LEDs seamless front frame with flate white high transmission arcylic cover complete with all accessories all including taking out old fittings as specified and directed. |
| 164 | Supply and fix in repair Slim surface mounted round LED down lighter of 12 watt aluminium die cast body with premium diffuser to ensure glare free & even distribution of light. |
| 165 | Supply and Fix Modular switch 1 way 6A,1 module |
| 166 | Supply and fix Modular switch 1 way 16A, 1 module |
| 167 | Supply and fix Modular switch 2 way 6A,1 module |
| 168 | Supply and Fix Modular Bell push 6A 1 module |
| 169 | Supply and fix modular Socket, 6A - 2/3 pin combined 2 module |
| 170 | Supply and fix modular Socket 6A/16A - 2/3 pin combined 2 module, |
| 171 | Supply and fix modular type Fan step regulator, 120W - 2 module |
| 172 | S&F of of Switch piano flush button single pole two way 5 Amps all as specified and as directed. |
| 173 | S&F of Angle holder PVC/polycarbonate type all as specified and as directed |
| 174 | S&F of switch piano flush type single pole one way 5 Amps |
| 175 | S&F of switch socket combination 5 pin 2 in 1, 5 A Flush type all as specified and as directed |
| 176 | S&F of switch socket combination 2 in 1, 3 pin 5 and 15 Amps flush type universal all as specified and as directed |
| 177 | S&F of bell push flush type 5A all as specified and as directed . |
| 178 | S&F in repair of MCB SPN 240 volts 32/40 Amps complete all as specified and as directed |
| 179 | S&F in repairs of MCB single pole 240 volts 10/16/20/32 Amps complete all as specified and as directed |
| 180 | S&F in repairs of MCB TPN 415 volts, 10KA 'C' curve 63 Amps complete all as specified and as directed |
| 181 | S&F in repairs of MCB TPN 415 volts, 10KA 'C' curve 100 Amps complete all as specified and as directed |
| 182 | S&F in repairs of MCB DB SPN 4 way double door type 240 volts with 200 Amps rated busbar as specified and as directed. |
| 183 | S&F in repairs of MCB DB SPN 8 way double door type 240 volts with 200 Amps rated busbar as specified and as directed. |
| 184 | S&F in repairs of MCB DB TPN 4 way with double door type 415 volts with 200 Amps rated busbar for housing MCBs as specified and as directed. |
| 185 | S&F of ceiling rose, surface bakelite type 65 x 50 mm, 2 to 3 terminals all as specified and as directed |
| 186 | S&F of stepped type electronic fan regulator flush Switch/socket type all as specified and as directed |
| 187 | S&F of Ding Dong bell AC 230 volts single pole. |
| 188 | Removing of old existing and provision of new sub main wiring 1100 volts grade multistranded FRLS copper conductors, two runs of single core 6 Sqmm along with 6 Sqm PVC insulated single core multistranded copper conductor cable as earth continuity conductor run along with PVC conduit all as specified and as directed |
| 189 | Removing of old existing and provision of new sub main wiring 1100 volts grade multistranded FRLS copper conductors, two runs of single core 4 Sqmm along with 4 Sqm PVC insulated single core multistranded copper conductor cable as earth continuity conductor run along with PVC conduit all as specified and as directed |
| 190 | Removing of old existing and provision of new sub main wiring 1100 volts grade multistranded FRLS copper conductors, two runs of single core 2.5 Sqmm along with 2.5 Sqm PVC insulated single core multistranded copper conductor cable as earth continuity conductor run along with PVC conduit all as specified and as directed |
| 191 | M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to galvanized earth lead wire 4 mm dia as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I 2010 and as specified or indicated and testing on completion incl earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, pre cost slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways incl funnel with watering pipe wire mesh and lugs, incl test point complete all as specified and as directed including dismantaling and taking down old Earthing plates. |
| 192 | Supply and fixing in repair 30 W LED bldg security light fitting with pressure die cast housing along with prismatic polycarbonate difuser with IP 66 protection including taking out old fittings. |
| 193 | S&F in repair of Bracket made out of GI tubing medium grade 25 mm bore , approx length 1.5 m long including MS clamps made out of MS flat iron 25 x 6 mm , nuts, bolts, washers etc and including before fixing applying two coats of aluminum paint over a coat of red oxide primer including removing the old existing GI bracket from bldg complete all as specified and directed. |
| 194 | S&F in repair Bulk Head Fitting suitable for indoor application of 10 watt, including electrical connecion from ceiling rose with 3 core 1.5 sqmm sheathed wire all as directed. |
| 195 | S&F in repair Decorative wall light fixture made up of polycabonate suitable for indoor application of 9 watt LED lamp E27 blub holder , modern wall lamp( Metal black Up & down light) including electrical connecion from ceiling rose with 3 core 1.5 sqmm sheathed wire all as directed. Brand- BrightLyt |
| 196 | S&F in repair LED Bulb suitable for indoor application of 9 watt, to fit in Angle Holder or Decorative wall light fixture all as directed. Make & Model No: Havells Cat part No: ADORE LED PLUS 9 W |
| 197 | S&F in repair ceiling fans outer body with complete accessories, etc all as specified and as directed |
| 198 | S&F in repair ceiling fans blade with complete accessories, etc all as specified and as directed |
| 199 | S&F in repair ceiling fans internal body with winding complete accessories, etc all as specified and as directed |
| 200 | S&F in repair PVC Fresh air fan MAXIMA DXI G02 IVORY DOM EX FAN of 150mm sweep 1200/1400 RPM with louver. |
| 201 | S&F in repair PVC Fresh air fan MAXIMA DXI WHITE DOM EX FAN of 200/225mm sweep 1200/1400 RPM with louver. |
| 202 | S&Fin repair PVC Fresh air fan MAXIMA DXI WHITE DOM EX FAN of 250/300mm sweep 1200/1400 RPM with louver. |
| 203 | S&F in in repair replacement of Single pole & neutral enclosure 20 Amps & 240 V with two pin and earth plug and socket complete with one single pole MCB 20Amps |
| 204 | Inspection, taking down, dismantling of geysers of any type/capacity, cleaning, descaling, reassembling & reinstallation on the old place incl hydraulic pressure test of container with hand operated hydraulic pump complete, brazing inner tank, internal wiring and reinstallation after necessary repair/replacement of old parts all as specified & as directed. Note : Replacement of old parts shall be measured & paid separately. |
| 205 | Supply only stainless/Mild steel inner tank of capacity 25 ltrs unit including internally assembly of any size and type complete all as specified & as directed. |
| 206 | Supply only internal assembly/apparatus rod unit of any size and type of capacity 25 ltrs complete all as specified & as directed. |
| 207 | Supply only heating element of 2 KW rating triangular/round type as per existing size and type including rubber washers all as specified & as directed. |
| 208 | Supply only heating element of 2 KW rating Hexagonal spiral/bend type as per existing size and type including rubber washers all as specified & as directed. |
| 209 | Supply only Thermostat/auto cut off of suitable size and type for 25/50 Ltrs capacity of any size. |
| 210 | Supply only Indicator lamp red and green type square/round. |
| 211 | Supply only Safety valve/high pressure valve/NRV of exisitng type ISI marked. |
| 212 | Supply only PVC insulated Copper cable flexible 3 core of size 40/0.0076 ISI marked. |
| 213 | Supply only outer cover of geyger for capacity 25 ltrs unit complete with all fitting and fixtures as specified & as directed. |
| 214 | S&F in repairs of exhaust fans outerframe for holding exhaust fan motor upto 225 mm sweep with supporting angle complete all as specified and directed. |
| 215 | S&F in repairs of exhaust fans outerframe for holding exhaust fan motor 300 mm sweep with supporting angle complete all as specified and directed. |
| 216 | M&L in repairs louver of exhaust fan suitable for 300/230 mm sweep complete accessories all as specified and directed |
| 217 | S&F in repairs of exhaust fans motor 300 mm sweep with supporting angle complete all as specified and directed. |
| 218 | M&L in repairs of exhaust fan motor suitable for 450 mm sweep complete accessories all as specified and directed |
| 219 | M&L for Preparation old painted surface & painting the geyser complete after cleaning & applying the same one coat of spray paint of white enamel, writing MES No incluing taking down and refixing in same or other place complete all as specified & as directed by Engr -in-Charge. |
| 220 | Taking down ceiling fan 1200mm/1400mm and wall mounted fan 300/450 mm sweep from position by duly disconnecting electric lines, preparing the surfaces, filling cavities with filler, after cleaning all dust, spray painting with one finishing coat of synthetic enamel paint including writing MES NO and replacing the split pin, rubber pully etc., including refixing and connecting the same complete all as specified and as directed. |
| 221 | Inspection, disconnecting electric connecting and dismantling of ceiling fan/exhaust/wall mounted fan of any type/size, cleaning including oiling and greasing the bearing, tighting of nuts and bolts and refixing on the old place complete after necessary repair/replacement of old parts all as specified & as directed. Note : Replacement of old parts shall be measured & paid separately. |
| 222 | Supply only ball bearing of various sizes / make as required for ceiling fans/wall mounting/exhaust fan including greasing complete all as specified and as directed. |
| 223 | Supply only Gun metal bush of any size/make suitable for ceiling fans all as specified and as directed. |
| 224 | Supply only capacitor 2.5 Mfd suitable for ceiling / exhaust /wall mounting fans complete all as specified and as directed. |
| 225 | Supply only capacitor 4.0 Mfd suitable for ceiling / exhaust/wall mounting fans complete all as specified and as directed. |
| 226 | PVC flexible cable twin twisted core of 23/0.0076 size multi stranded copper conductor suitable for connecting ceiling fans / exhaust /wall mounting fans complete all as specified and as directed. |
| 227 | Rubber bush with MS bolts, nuts & washers with 'U' clamps for ceiling fans complete all as specified and as directed. |
| 228 | Dismantling /opening the ceiling fan of 1200 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and reassembling/re-fixing in its p complete all as specified and as directed. |
| 229 | Dismantling /opening the ceiling fan of 1400 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and reassembling complete all as specified and as directed. |
| 230 | Dismantling /opening the wall mounted fan of 300 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and reassembling complete all as specified and as directed. |
| 231 | Taking down exhaust fans 230 mm/300mm / 450mm sweep from position by duly disconnecting electric lines, preparing the surfaces, filling cavities with filler, after cleaning all dust, spray painting with one finishing coat of synthetic enamel paint including writing MES NO and replacing the split pin, rubber pully etc., including refixing and connecting the same complete all as specified and as directed. |
| 232 | Dismantling /opening the exhaust fan of 230 mm/300 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and reassembling complete all as specified and as directed. |
| 233 | Dismantling /opening the exhaust fan of 450 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and reassembling complete all as specified and as directed. |
| 234 | M&L extension of down rod for ceiling fan upto 1.5 mtr including nut, bolts , washers complete accessories all as specified and as directed. |
| 235 | Excavation in trenches not exceeding 1.5M wide and not exceeding 1.5M deep for laying cables and for foundation of poles etc and getting out in loose/soft soil. |
| 236 | Returning, filling in, including spreading, levelling, watering and well ramming, in layers not exceeding 25 cm complete using soil. |
| 237 | Removing excavated material n exc. 50m and depositing where n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point. |
| 238 | M&L for sand cushioning with a layer of M sand 23 cm thick under and above the cable complete all as specified and as directed |
| 239 | S&L sub class burnt bricks for cable protection complete as specified as directed |
| 240 | S&L XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armouned power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 16 Sqmm 4 core laid in trenches. |
| 241 | S&L XLPE insulated, screened, PVC bedded, galvanised steen strip or wire armouned power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 35 Sqmm, 3.5 core laid in trenches/wall. |
| 242 | S&L XLPE insulated, screened, PVC bedded, galvanised steen strip or wire armouned power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 25 Sqmm, 4 core laid in trenches/wall. |
| 243 | S&L XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armouned power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 10 Sqmm 4 core laid in trenches. |
| 244 | S&L XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armouned power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 10 Sqmm 2 core laid in trenches. |
| 245 | S&L XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armouned power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 6 Sqmm 2 core laid in trenches. |
| 246 | S&F in repair capacitor 2.5 Mfd suitable for ceiling / exhaust /wall mounting fans complete all as specified and as directed. |
| 247 | S&F heating element of 2 KW rating triangular/round type as per existing size and type including rubber washers all as specified & as directed. |
| 248 | S&F heating element of 2 KW rating Hexagonal spiral/bend type as per existing size and type including rubber washers all as specified & as directed. |
| 249 | S&F Thermostat/auto cut off of suitable size and type for 25/50 Ltrs capacity of any size. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 31, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 21, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysNov 23, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender