Tender For Jal Jeevan Mission (Jjm)-Cwss To Haripad And Adjoining Panchayaths - Electromechanical Works - Pumps, Transformer, Vcb, Main Control Panel, Rmu Etc. In Wtp At Pallippad, And Sump At Muthukulam-Electromechanical Work In Wtp At Pallipad - Mo
Tender Overview
Project Description
Tender for Jal Jeevan Mission (Jjm)-Cwss To Haripad And Adjoining Panchayaths - Electromechanical Works - Pumps, Transformer, Vcb, Main Control Panel, Rmu Etc. In Wtp At Pallippad, And Sump At Muthukulam-Electromechanical Work In Wtp At Pallipad - Motor Pumpset For Pumping To Pallipad Ohsr And Transformer And Allied Works In Wtp Compound-Pipeline Work
BOQ
| Sl. No. | Item Description |
| 1 | Appendix-A- Electromechanical Work in WTP at Pallipad - Motor Pumpset for pumping to Pallipad OHSR and Transformer and allied works in WTP compound |
| 2 | OD53628/2026-2027:Design, Supply and erection of centrifugal pump set with the following specification,1.Pump -Supply, erection, testing and commissioning of KWA pre-qualified reputed make Centrifugalpump sets with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base platewith coupling, coupling guard foundation bolts & nuts etc. complete suitable for coupling thepump and motor above the base plate etc. complete including providing suitable concretefoundation including cost of cement sand and metal etc. complete. The duty condition is asfollows.- Discharge 45 LPS Speed up to 1500RPM,Total Head 32m, Negative Suction, Lengthof suction pipe 2.5 m, size of pumping main 250mm dia pipe.Alternatively the inlet & outletlevels, type, size & length of pumping main etc. can be given Modification may done for monoblock pump set. |
| 3 | OD6077/2026-2027:Motor - Supply, erection, testing and commissioning of KWA pre-qualified reputed make horizontal solid shaft ,foot mounted TEFC squirrel cage induction motor, 22KW,415 V,50Hz,IP 55 protection, Class F Insulation, suitable for the above pump working 3 phase 50Hz AC supply, working voltage 415V. The motor shall confirm to EEFI/IS 325 including providing suitable concrete foundation<br>including cost of cement sand and metal etc. Complete for 415 V motors digital motor protection relay shall be included in starter as per per IE rules. Flexible coupling shall be used for coupling of pumps and motors. |
| 4 | OD6070/2026-2027:Supply, Errection, Testing and commissioning of 11KV/433V, 1000KVA, 50Hz, 3phase , Vector Group Dyn 11 Resin Cast Indoor type copper wound Transformer(IP 23) with on load tap changer with RTCC &AVR panel tapping +5% to -5% in steps of 2.5% with winding temperature scanner and hooter, provision for Bus Duct on the LV side and HV side connected with 11KV VCB panel and the LV compartment which houses ACB. . The Electrical equipments are to be cooled by natural ventilation |
| 5 | OD6024/2026-2027:Supply and Installation, testing and commissioning of 11KV ,50C/S , 630A , 350MVA, VCB panel fitted with draw out type VCB with Manual/Motor operated spring charging mechanism with 230V AC motor, motor control switch, shunt trip coil of 24V DC, closing coil of 24V DC, Auxiliary Contact 6NO + 6NC,Mechanical ON/OFF indicator, mechanicaloperation counter, Anti pumping feature, overcurrent and earth fault relay, protection CT, (--/5A, 5P10,15VA , 11kV/110V, Cl-0.2, 25VA PT Instantaneous IDMTrelay with Microprocessor based 3O/C + and 1EF Protection relay, Strip Heater with thermostat, Power pack 230V AC-24 V DC emergency OFF push button, ammeter & voltmeter with selector switch, remote trip facility& 3nos Resin cast Current Transformers & 1no PT Units, both having accuracy class of 0.2 for KSEB metering with sealing facility and provision for fixing TOD meter |
| 6 | OD6109/2026-2027:Supply and installation of Compact Sandwich Aluminium Busway System with copper contact JointsTotally Type Tested in accordance with IEC61439-6, of below mentioned rating 1000V,3Phase 4 Wire, 50Hz with 100% neutral, 50% integral earth without external earthstrip, IP54, Dual housed in electrogalvanised sheet steel and aluminium enclosure,ANSI49 Grey epoxy painting and with KEMA-KEUR, ASTA DIAMOND Certification-1600A Feeder (IP 65) |
| 7 | OD6108/2026-2027:Supply and installation of Compact Sandwich Aluminium Busway System with copper contact JointsTotally Type Tested in accordance with IEC61439-6, of below mentioned rating 1000V,3Phase 4 Wire, 50Hz with 100% neutral, 50% integral earth without external earthstrip, IP54, Dual housed in electrogalvanised sheet steel and aluminium enclosure,ANSI49 Grey epoxy painting and with KEMA-KEUR, ASTA DIAMOND Certification-1600A Flanged end (IP 65) |
| 8 | OD6110/2026-2027:Supply and installation of Compact Sandwich Aluminium Busway System with copper contact JointsTotally Type Tested in accordance with IEC61439-6, of below mentioned rating 1000V,3Phase 4 Wire, 50Hz with 100% neutral, 50% integral earth without external earthstrip, IP54, Dual housed in electrogalvanised sheet steel and aluminium enclosure,ANSI49 Grey epoxy painting and with KEMA-KEUR, ASTA DIAMOND Certification-1600A 90 deg elbow horizontal (IP 65) |
| 9 | OD6112/2026-2027:Supply and installation of Compact Sandwich Aluminium Busway System with copper contact JointsTotally Type Tested in accordance with IEC61439-6, of below mentioned rating 1000V,3Phase 4 Wire, 50Hz with 100% neutral, 50% integral earth without external earthstrip, IP54, Dual housed in electrogalvanised sheet steel and aluminium enclosure,ANSI49 Grey epoxy painting and with KEMA-KEUR, ASTA DIAMOND Certification-1600A 90 deg elbow vertical(IP 65) |
| 10 | OD6107/2026-2027:Supply and installation of Compact Sandwich Aluminium Busway System with copper contact JointsTotally Type Tested in accordance with IEC61439-6, of below mentioned rating 1000V,3Phase 4 Wire, 50Hz with 100% neutral, 50% integral earth without external earthstrip, IP54, Dual housed in electrogalvanised sheet steel and aluminium enclosure,ANSI49 Grey epoxy painting and with KEMA-KEUR, ASTA DIAMOND Certification-1600A Cu flexible |
| 11 | OD6113/2026-2027:Supply and installation of Compact Sandwich Aluminium Busway System with copper contact JointsTotally Type Tested in accordance with IEC61439-6, of below mentioned rating 1000V,3Phase 4 Wire, 50Hz with 100% neutral, 50% integral earth without external earthstrip, IP54, Dual housed in electrogalvanised sheet steel and aluminium enclosure,ANSI49 Grey epoxy painting and with KEMA-KEUR, ASTA DIAMOND Certification-1600A Adaptor box (additional as per site condition) |
| 12 | OD6051/2026-2027:Supplying, laying and clamping of XLPE insulated AL HTarmoured power cable, conductors of best conductivityaluminium 11KV grade of following sizes in existing cabletray / existing trench (excluding sand cushioning andprotective covering) / clipping directly on wall / ceiling. |
| 13 | OD6053/2026-2027:Supplying all material (Termination kit) and providingindoor / outdoor end termination for existing XLPEinsulated AL conductor HT power cable of the followingsize to the transformer HT terminal as per IS 1255.Including properly cleaning, aligning and providingmechnical support to the cable, inspection for any defectsetc. |
| 14 | OD6091/2026-2027:Supply and installation of following Current transformerwith enclosure for Neutral CT-300/5 5P10 |
| 15 | OD6111/2026-2027:Supply, erection, testing and commissioning of cubicle type, dust and vermin proof, floor mounted, front operated extensible type MV panel board for 1000KVA Transformer |
| 16 | OD54479/2026-2027:Supply, erection, testing and commissioning of cubicle type, dust and vermin proof, floor mounted, front operated extensible type MV panel board with 2 MCCB Outgoings, Mechanically interlock , Soft Starters suitable for 30 HP - 2nos |
| 17 | OD6061/2026-2027:Supply, Fabrication, Installation, Testing andCommissioning of Cubicle type, dust and vermin proof,floor mounted, front operated APFC Panel (400kVAR) madeout of 16SWG thick CRCA sheet fully compartmentalisedcomplete with hinged and earthed front doors with nameplate, danger notice, heavy duty rubber gaskets, removablegland plates made out of 3mm thick sheet steel. The switchboard should have a set of suitably rated TPN AluminiumBusbars with the specified current and fault level, insulatedwith heat shrinkable, colour coded PVC sleeves andsupported using DMC/SMC piller or finger type Busbarsupports. the design should be as per the standards of theelectrical inspectorate. Capacitors (APP Type), Capacitorduty contactors, APFC Relay (12 Stage), LED indication typelamps, CT's, Multifunction meter and 2A Backlite fuses areincluded in this panel.Incomer800A 3P FIXED ACB ISO800A TPN AL busMFMRYB phase indicating lamps (LED ) with control fuses andswitches -1 set.12 stage APFC relayCT:-800/5A , CL-1 , 15VA -3NosOUTGOING125A 3P 25kA current limiting type MCCB withencapsulated double break mechanism - 3 Nos100A 3P 25kA MCCB with encapsulated double breakmechanism -1No63A 3P 25kA MCCB with encapsulated double breakmechanism - 8 Nos50kVAR CAPACITOR,440V APP type capacitor withstandupto 525V having IS -13585 with 4 year replacementguarantee - 3Nos40kVAR CAPACITOR ,440V APP type capacitor withstandupto 525V having IS-13585 with 4 year replacementguarantee - 1Nos25kVAR CAPACITOR , 440V APP type capacitor withstandupto 525V having IS-13585 with 4 year replacementguarantee - 8Nos10kVAR CAPACITOR , 440V APP type capacitor withstandupto 525V having IS-13585 with 4 year replacementguarantee - 1No67kVAR CAPACITOR DUTY CONTACTOR - 3Nos50kVAR CAPACITOR DUTY CONTACTOR - 1 No32kVAR CAPACITOR DUTY CONTACTOR - 8Nos16.7kVAR CAPACITOR DUTY CONTACTOR - 1No50kVAR REACTOR ,7% F-class copper wound series reactorwith thermister -3Nos25kVAR REACTOR ,7% F-class copper wound series reactorwith thermister -8Nos10kVAR REACTOR ,7% F-class copper wound series reactorwith thermister -1No40kVAR REACTOR ,7% F-class copper wound series reactorwith thermister -1No |
| 18 | OD6071/2026-2027:Supplying, laying and clamping of 3.5x300sqmm XLPE insulated and PVCsheathed armoured power cable, conductors of bestconductivity aluminium 1.1KV grade strictly conforming IS:1554 (Part I) of following sizes in existing cable tray /trench / clipping directly on wall / ceiling |
| 19 | OD6068/2026-2027:Supplying, laying and clamping of 3.5x240sqmm XLPE insulated and PVCsheathed armoured power cable, conductors of bestconductivity aluminium 1.1KV grade strictly conforming IS:1554 (Part I) of following sizes in existing cable tray /trench / clipping directly on wall / ceiling |
| 20 | OD6039/2026-2027:Supplying, laying and clamping of 3.5x185sqmm XLPE insulated and PVCsheathed armoured power cable, conductors of bestconductivity aluminium 1.1KV grade strictly conforming IS:1554 (Part I) of following sizes in existing cable tray /trench / clipping directly on wall / ceiling |
| 21 | OD6037/2026-2027:Supplying, laying and clamping of 3.5x150 sqmm XLPE insulated and PVCsheathed armoured power cable, conductors of bestconductivity aluminium 1.1KV grade strictly conforming IS:1554 (Part I) of following sizes in existing cable tray /trench / clipping directly on wall / ceiling |
| 22 | OD6066/2026-2027:Supplying, laying and clamping of XLPE insulated and PVCsheathed armoured power cable, conductors of bestconductivity aluminium 1.1KV grade strictly conforming IS:1554 (Part I) of following sizes in existing cable tray /trench / clipping directly on wall / ceiling 3cx150 sqmm |
| 23 | OD6017/2026-2027:Supplying, laying and clamping of XLPE insulated and PVCsheathed armoured power cable, conductors of bestconductivity aluminium 1.1KV grade strictly conforming IS:1554 (Part I) of following sizes in existing cable tray /trench / clipping directly on wall / ceiling- 3x120 sqmm |
| 24 | OD6044/2026-2027:Supplying, laying and clamping of XLPE insulated and PVCsheathed armoured power cable, conductors of bestconductivity aluminium 1.1KV grade strictly conforming IS:1554 (Part I) of following sizes in existing cable tray /trench / clipping directly on wall / ceiling-3.5x70 sqmm |
| 25 | OD6032/2026-2027:Supplying, laying and clamping of XLPE insulated and PVCsheathed armoured power cable, conductors of bestconductivity aluminium 1.1KV grade strictly conforming IS:1554 (Part I) of following sizes in existing cable tray /trench / clipping directly on wall / ceiling-3.5x35 sqmm |
| 26 | OD6023/2026-2027:Supplying, laying and clamping of 4x16 sq.mm XLPE insulated and PVCsheathed armoured power cable, conductors of bestconductivity aluminium 1.1KV grade strictly conforming IS:1554 (Part I) of following sizes in existing cable tray /trench / clipping directly on wall / ceiling |
| 27 | OD6073/2026-2027:Supplying, laying and clamping of XLPE insulated and PVCsheathed armoured power cable, conductors of bestconductivity aluminium 1.1KV grade strictly conforming IS:1554 (Part I) of following sizes in existing cable tray /trench / clipping directly on wall / ceiling-3x16 sqmm cu ar cable |
| 28 | OD6076/2026-2027:Supplying, laying and clamping of XLPE insulated and PVCsheathed armoured power cable, conductors of bestconductivity aluminium 1.1KV grade strictly conforming IS:1554 (Part I) of following sizes in existing cable tray /trench / clipping directly on wall / ceiling-4x1.5 sq.mm copper cable |
| 29 | OD6103/2026-2027:Supplying, laying and clamping of XLPE insulated and PVCsheathed armoured power cable, conductors of bestconductivity aluminium 1.1KV grade strictly conforming IS:1554 (Part I) of following sizes in existing cable tray /trench / clipping directly on wall / ceiling-2x1.5 sq.mm copper cable |
| 30 | OD6075/2026-2027:Supplying, laying and clamping of XLPE insulated and PVCsheathed armoured power cable, conductors of bestconductivity aluminium 1.1KV grade strictly conforming IS:1554 (Part I) of following sizes in existing cable tray /trench / clipping directly on wall / ceiling-1c x 95 sqmm copper flexible cable |
| 31 | OD6035/2026-2027:Supplying, laying and clamping of XLPE insulated and PVCsheathed armoured power cable, conductors of bestconductivity aluminium 1.1KV grade strictly conforming IS:1554 (Part I) of following sizes in existing cable tray /trench / clipping directly on wall / ceiling-1c x 120 sqmm copper flexible cable |
| 32 | OD6048/2026-2027:Supplying and fixing of compression gland for armouredaluminium/copper conductor cable 1.1kv grade andmaking end termination suitable for 2/3/3.5/4 core cablesof the following sizes as required 3.5x400sqmm |
| 33 | OD6100/2026-2027:Supplying and fixing of compression gland for armouredaluminium/copper conductor cable 1.1kv grade andmaking end termination suitable for 2/3/3.5/4 core cablesof the following sizes as required 3.5x300sqmm |
| 34 | OD6040/2026-2027:Supplying and fixing of compression gland for armouredaluminium/copper conductor cable 1.1kv grade andmaking end termination suitable for 2/3/3.5/4 core cablesof the following sizes as required 3.5x240sqmm |
| 35 | OD6096/2026-2027:Supplying and fixing of compression gland for armouredaluminium/copper conductor cable 1.1kv grade andmaking end termination suitable for 2/3/3.5/4 core cablesof the following sizes as required 3.5x185sqmm |
| 36 | OD6025/2026-2027:Supplying and fixing of compression gland for armouredaluminium/copper conductor cable 1.1kv grade andmaking end termination suitable for 2/3/3.5/4 core cablesof the following sizes as required 3.5x150 sqmm |
| 37 | OD6059/2026-2027:Supplying and fixing of compression gland for armouredaluminium/copper conductor cable 1.1kv grade andmaking end termination suitable for 2/3/3.5/4 core cablesof the following sizes as required 3cx150 sqmm al ar cable |
| 38 | OD6047/2026-2027:Supplying and fixing of compression gland for armouredaluminium/copper conductor cable 1.1kv grade andmaking end termination suitable for 2/3/3.5/4 core cablesof the following sizes as required 3x120 sqmm |
| 39 | OD6027/2026-2027:Supplying and fixing of compression gland for armouredaluminium/copper conductor cable 1.1kv grade andmaking end termination suitable for 2/3/3.5/4 core cablesof the following sizes as required 3.5x70 sqmm |
| 40 | OD6105/2026-2027:Supplying and fixing of compression gland for armouredaluminium/copper conductor cable 1.1kv grade andmaking end termination suitable for 2/3/3.5/4 core cablesof the following sizes as required 3.5x35 sqmm |
| 41 | OD6095/2026-2027:Supplying and fixing of compression gland for armouredaluminium/copper conductor cable 1.1kv grade andmaking end termination suitable for 2/3/3.5/4 core cablesof the following sizes as required 4x16 sq.mm |
| 42 | OD6062/2026-2027:Supplying and fixing of compression gland for armouredaluminium/copper conductor cable 1.1kv grade andmaking end termination suitable for 2/3/3.5/4 core cablesof the following sizes as required 3x16 sqmm cu ar cable |
| 43 | OD6085/2026-2027:Supplying and fixing of compression gland for armouredaluminium/copper conductor cable 1.1kv grade andmaking end termination suitable for 2/3/3.5/4 core cablesof the following sizes as required 4x1.5 sq.mm copper cable |
| 44 | OD6101/2026-2027:Supplying and fixing of compression gland for armouredaluminium/copper conductor cable 1.1kv grade andmaking end termination suitable for 2/3/3.5/4 core cablesof the following sizes as required 2x1.5 sq.mm copper cable |
| 45 | OD6034/2026-2027:Supplying and fixing of compression gland for armouredaluminium/copper conductor cable 1.1kv grade andmaking end termination suitable for 2/3/3.5/4 core cablesof the following sizes as required 1c x 95 sqmm copper flexible cable |
| 46 | OD6029/2026-2027:Supplying and fixing of compression gland for armouredaluminium/copper conductor cable 1.1kv grade andmaking end termination suitable for 2/3/3.5/4 core cablesof the following sizes as required 1c x 120 sqmm copper flexible cable |
| 47 | OD6082/2026-2027:Supply and providing ISI plate earthing as per IS: 3043 with1200x1200x12mm CI earth plate with Cu strip extendingto the other end of the earth plate and bolt to the plate withminimum 3 nos. of SS bolts, filling earth enhancing mineralcompount of approved type around earth plate upto a distanceof 15cm. with cover |
| 48 | OD6057/2026-2027:Supply and laying Copper strip /GI strip of the followingsizes laid 0.6m below ground level excluding excavatingtrench of suitable size/tray and refilling etc as required 25x6mm Copper strip |
| 49 | OD6104/2026-2027:Supply and laying Copper strip /GI strip of the followingsizes laid 0.6m below ground level excluding excavatingtrench of suitable size/tray and refilling etc as required 25x3mm Copper strip |
| 50 | OD6067/2026-2027:Fixing of 32x6 mm Cu Earth clamp (Main Earth Terminal /Earth bus) with all provision for making protectiveearthing system and equipotential bonding |
| 51 | OD6086/2026-2027:Supply and drawing bare copper conductors of thefollowing sizes along with wiring/ cables and givingconnections as required |
| 52 | OD6031/2026-2027:Supply and installation of 3 phase double cover MCBvertical DB IP42/43 including copper busbar, neutral linkand DIN bar suitable for fixing outgoing MCB, flush mounton wall, including cutting holes on the wall making good thedamage etc. as required |
| 53 | OD6033/2026-2027:Supply and installation of double cover enclosure of MCBDB IP42/43 for 1phase inclusive of copper/brass bus bar,neutral link and DIN bar suitable for incorporating MCB,isolator etc, flush mount on the wall including cutting holeson wall,making good the damages etc. as required |
| 54 | OD6078/2026-2027:Supply and installation of industrial / metal clad plugsocket IP54 with MCB control and fixing on locations 20A 2P MCB |
| 55 | OD6030/2026-2027:Supply and installation of industrial / metal clad plugsocket IP54 with MCB control and fixing on locations 32A 4P MCB |
| 56 | OD6072/2026-2027:Supply and installation of following accessories / circuitbreaker in exisitng VDB / DB and making all connections,dressing up as per Electrical schematic and DB schedule,using suitable terminal sockets, marking ferrules etccomplete. 63/40A FP Isolator |
| 57 | OD6050/2026-2027:Supply and installation of following accessories / circuitbreaker in exisitng VDB / DB and making all connections,dressing up as per Electrical schematic and DB schedule,using suitable terminal sockets, marking ferrules etccomplete. 40A TP MCB |
| 58 | OD6084/2026-2027:Supply and installation of following accessories / circuitbreaker in exisitng VDB / DB and making all connections,dressing up as per Electrical schematic and DB schedule,using suitable terminal sockets, marking ferrules etccomplete. 32A TP MCB |
| 59 | OD6041/2026-2027:Supply and installation of following accessories / circuitbreaker in exisitng VDB / DB and making all connections,dressing up as per Electrical schematic and DB schedule,using suitable terminal sockets, marking ferrules etccomplete. 16A TP MCB |
| 60 | OD6099/2026-2027:Supply and installation of following accessories / circuitbreaker in exisitng VDB / DB and making all connections,dressing up as per Electrical schematic and DB schedule,using suitable terminal sockets, marking ferrules etccomplete. 6A-32A SP MCB |
| 61 | OD6079/2026-2027:Supply and installation of following accessories / circuitbreaker in exisitng VDB / DB and making all connections,dressing up as per Electrical schematic and DB schedule,using suitable terminal sockets, marking ferrules etccomplete. 63A100mA FP RCCB |
| 62 | OD6052/2026-2027:Supply and installation of following accessories / circuitbreaker in exisitng VDB / DB and making all connections,dressing up as per Electrical schematic and DB schedule,using suitable terminal sockets, marking ferrules etccomplete. 40A 30mA DP RCCB |
| 63 | OD6022/2026-2027:Supply and installation of following accessories / circuitbreaker in exisitng VDB / DB and making all connections,dressing up as per Electrical schematic and DB schedule,using suitable terminal sockets, marking ferrules etccomplete. 40A 2P Isolator |
| 64 | OD6074/2026-2027:Supply Fixing of medium grade rigid PVC conduit, open orconcealed as required in circuit wiring etc |
| 65 | OD6058/2026-2027:Supply all material and wiring for light / fan point (Primary orfirst point of group control lights) using 3 runs 1.5 sqmm FRPVC insulated copper wire, modular switches, front plate, MSBox, wiring connector, flexible connection using 2/3 coreflexible round cables etc.,. 2 way controlled points shallcounted as 2 points. |
| 66 | OD6065/2026-2027:Wiring for Secondary light points (looping) using 2 runs 1.5sqmm FR PVC insulated copper wire or 1.5sqmm 3 coreflexible weather proof cable. |
| 67 | OD6080/2026-2027:Wiring for 6A plug points in combined position using 3runs1.5 sqmm FR PVC insulated copper wire including supplyand fixing of 6A / 3 pin modular plug socket, switches andgiving connections. (circuit from same switch board) |
| 68 | OD6021/2026-2027:Supply all materials and wiring for 6A/16A plug points inindependent position using 2 runs 2.5 sqmm + 1 run 1.5sqmm FR PVC insulated including supply and fixing of MSbox, 6A / 16A 3 pin modular socket, switch, front plate,conduiting and giving connections.(with out circuit wiring) |
| 69 | OD6093/2026-2027:Supply and drawing PVC FRLS insulated copper wire offollowing size through existing conduit and giving necessaryconnections etc as required in the following runs 2 Runs 2.5mm² Cu wire + 1Run 1.5mm² Cu wire |
| 70 | OD6026/2026-2027:Supply and drawing PVC FRLS insulated copper wire offollowing size through existing conduit and giving necessaryconnections etc as required in the following runs. 2Runs 4mm² Cu wire + 1Run 2.5mm² Cu wire |
| 71 | OD6090/2026-2027:Supply Installation, testing and commissioning of thefollowing items including cutting holes for recessed fittings,fixing anchor bolt for fan clamps etc. complete.(supply oflights in client scope)-LED flood lights. (50 watts) |
| 72 | OD6018/2026-2027:Supply Installation, testing and commissioning of thefollowing items including cutting holes for recessed fittings,fixing anchor bolt for fan clamps etc. complete.(supply oflights in client scope)-LED Tube light |
| 73 | OD6046/2026-2027:Supply Installation, testing and commissioning of thefollowing items including cutting holes for recessed fittings,fixing anchor bolt for fan clamps etc. complete.(supply oflights in client scope)-50 watts IP65 street light with 5 meter pole |
| 74 | OD6038/2026-2027:Supply of 11kV grade rubber gloves |
| 75 | OD6098/2026-2027:Providing MV voltage danger notice board 200mmx150mm |
| 76 | OD6036/2026-2027:Providing high voltage danger notice board 300mmx200mm |
| 77 | OD6056/2026-2027:Supply & fixing Laminated drawings of electrical lay out and schematic drawing, shock treatment chart etc on good frame work. |
| 78 | OD6045/2026-2027:Supply & installation of following electrical grade rubber mat conforming to IS standards-2mm 3.3 kV |
| 79 | OD6081/2026-2027:Supply & installation of following electrical grade rubber mat conforming to IS standards-21.5mm 11kV |
| 80 | OD6020/2026-2027:Supply and installation of emergency push button |
| 81 | OD6060/2026-2027:Charges for testing CT PT unit and TOD meter at TMR and recollecting the same after testing (professional charges only ) |
| 82 | OD6102/2026-2027:Charges for testing EFR,neutral CT,other relays at meter testing and standards laboratory and obtaining certificate excluding statutory and sundry charges |
| 83 | OD6049/2026-2027:Charges for supply and installation of HT / TOD meter-Class 0.2S, 11KV/110V,-/5A,3-Phase 4 wire conforming to KSEB guidelines |
| 84 | OD6106/2026-2027:Supply of cable termination box motors of suitable size for each motors |
| 85 | OD6087/2026-2027:Supply and installation of 5 HP vaccum pump set with necessary starter |
| 86 | OD6055/2026-2027: Supply and erection of Perforated Galvanised cable tray with suitable mounting achour fastners & mounting accessories as required confirming with all neccessary accessories |
| 87 | OD6063/2026-2027:Supply all materials and Fabrication and erection of supports fabricated out of MS angles C Channel and M S flats of adequate size for erection of panel boards, other necessary equipments etc The supports shall be painted with 2 coats of zinc chromate primer and 2 coats of enamelpaint. |
| 88 | OD6016/2026-2027:Preparation of all drawings submitting and getting schemeapproval from Electrical Inspectorate, submitting ofcompletion certificate, arranging inspection, gettingenergisation sanction from Electrical Inspectorate andobtaining permanent power allocation & power connectionfrom KSEBL. (Excluding statutory and sundry charges |
| 89 | OD6097/2026-2027:Deposit work charges for Power Allocation and connection charges. |
| 90 | OD54230/2026-2027:Supply, Conveying & fixing CI Sluice Valves Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 200mm Class I by providing complete with bolts, nuts, rubber insertions etc. Including automating the valves supplied by providing electric actuators with the provision of fully automatic, semi-automatic and manual operating modes, including the cost of supply erection and commissioning cost of electric motors, control panels, cost of electric items, labour, trial running, maintenance for a period of 2 years, Inspection charges for above all items etc. complete |
| 91 | OD54229/2026-2027:Supply, Conveying & fixing CI Non Return Valve, Conforming to IS 5312 Part I - 1984, PN 1.0, Size 200mm |
| 92 | OD54478/2026-2027:Conveying and laying mS pipes excluding cost of pipes and specials,250 mm dia mS pipes-Dataderived from 18.72.19 in DAR |
| 93 | 100.37.1:Cutting M.S. sheet, pipe and specials by gas cutting including cost of gas, all labour and hire charges of tools etc., complete. |
| 94 | 100.37.2:Grinding the cut edges / welded portions in M.S. sheet, pipe and specials by grinding machine including all labour and hire charges of tools etc., complete. |
| 95 | 100.37.3:Welding M.S. sheet, pipe and special by gas or electric plant for three run welding including cost of welding rod / gas, all labour and hire charges of tools etc., complete. |
| 96 | 100.37.8.1:In situ fabrication of M.S. pipes of size 250mm (I.D.) using 8mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete. |
| 97 | 100.37.8.2:Fabricating M.S. flanges of diameter 250mm using 12mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete: For pipes fabricated with 8mm thick M.S. plates. |
| 98 | 100.37.6.1:In situ fabrication of M.S. pipes of size 150mm (I.D.) using 8mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete. |
| 99 | 100.37.6.2:Fabricating M.S. flanges of diameter 150mm using 12mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete: For pipes fabricated with 8mm thick M.S. plates. |
| 100 | 100.37.7.1:In situ fabrication of M.S. pipes of size 200mm (I.D.) using 8mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete. |
| 101 | 100.37.7.2:Fabricating M.S. flanges of diameter 200mm using 12mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete: For pipes fabricated with 8mm thick M.S. plates. |
| 102 | 5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 103 | 5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 104 | 5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 105 | 13.9.1:Cement plaster 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement.12 mm cement plaster |
| 106 | Appendix-B- Supply and fixing flowmeter at WTP Pallipad before the Aerator |
| 107 | OD53736/2026-2027:Supply, installation, testing, and commissioning of a remote-type insertion electromagnetic flow meter of approved make for a DN 800 water pipeline including an aluminum alloy remote LCD display with a 20-meter cable, operate on 220 VAC, and provide 4-20mA, pulse, and RS485 outputs, complete |
| 108 | 100.7.1:Bailing out water with 5HP engine and pump set including conveyance to the site, erecting, dismantling and taking back of engine and pump, cost of fuel lubricating oil and other stores pay of staff etc., complete. |
| 109 | OD54456/2026-2027:Constructing chamber of inner size 2 m x2 m x2.20 m in M-25 grade cement concrete for reinforced cement concrete work and 10 mm Thermo-mechanically treated reinforcement bars of 500D, for foundation, side wall and cover slab (Plat form 2.30 mx2.30 mx0.20 m), side wall 20 cm, cover slab giving gap for 2Nos manhole cover of size 0.45m x 0.61m, Base slab (2.30m x 2.30m x 0.20m) to be placed over a PCC base of size 2.50m x 2.50m x 0.10 m in 1:3:6 using 20 mm broken stone, plastering inside the valve chamber and cover slab in CM.1:3, 12 mm thick including cost and conveyance of all materials etc. complete. as per the direction of deptl officers |
| 110 | 100.41.34:Supplying and fixing Rectangular C.I. manhole cover 455mm x 610mm with frame (low duty) charges including all cost, labour charges etc., complete. |
| 111 | 10.2:Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender