Bids Are invited for Custom Bid For Services - Administrative Approval For Providing And Installation Of Automatic Lighting Control System With Earth Leakage Protection At Sasti Expansion Ocm Sasti Sub Area - Providing & Erecting 4 Pole Mccb, 415V, U
Tender Overview
Project Description
Bids Are invited for Custom Bid For Services - Administrative Approval For Providing And Installation Of Automatic Lighting Control System With Earth Leakage Protection At Sasti Expansion Ocm Sasti Sub Area - Providing & Erecting 4 Pole Mccb, 415V, Up To 100A, Rated Short-Circuit Breaking Capacity 25 Ka (Ics=100% Of Icu), Adjustable Thermal (Overload) Setting And Fixed Magnetic Setting With Provided Leads, Provision For Installation Of Shunt/Uv/Trip Alarm Contact. Mccb With Phase Barriers On Both Sides, Insulation Withstand Capacity 800V, No Line-Load Bias In Provided Enclosure/Panel As Per Specification No. Sw-Mccb , Supplying And Erecting Programmable Digital Almanac Timer Microcontroller Based With Real Time Clock To Operate On Derived Switching On And Switching Off Street Light As Per Daily Sunset And Sunrise Respectively Automatically Having 4 Digit Led Continuous Time Display, Relay Output 230V / 10A With 10 Hrs. Battery Backup And Manual Over Drive Facility Capable To Drive Different Capacity Contactors Timer Erected In Provided M.S. Box
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | Providing & erecting 4 Pole MCCB, 415V, up to 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-MCCB | Providing & erecting 4 Pole MCCB, 415V, up to 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-MCCB |
| 2 | Supplying and erecting programmable digital almanac timer microcontroller based with real time clock to operate on derived switching “ON” and switching “OFF” street light as per daily sunset and sunrise respectively automatically having 4 digit LED continuous time display, relay output 230V / 10A with 10 hrs. battery backup and manual over drive facility capable to drive different capacity contactors timer erected in provided M.S. box | Supplying and erecting programmable digital almanac timer microcontroller based with real time clock to operate on derived switching “ON” and switching “OFF” street light as per daily sunset and sunrise respectively automatically having 4 digit LED continuous time display, relay output 230V / 10A with 10 hrs. battery backup and manual over drive facility capable to drive different capacity contactors timer erected in provided M.S. box |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender