Defence Statutory Bodies & Commissions/Committees Closing in 10 days TDR #58294233

Tender For Special Repair Of Security Wall & Main Gate Area Near Cp-2 And Provn Of Additional/Alteration Of Jcos Bathroom (Two) Near Bldg No P-72,P-73 P-76 & P-77 At Guard Under Ge (Army) No 1 Jodhpur. Job No (I) 25/Sr(Bldg)/Jodh/2026-27 (Ii) 18/Rw/J

Issued by Statutory Bodies & Commissions/Committees · Jodhpur, Rajasthan
Tender Value
33.74 Lakhs
Estimated cost
Bid Submission
20 Nov 2026
10 days left
EMD
67480
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jodhpur → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Special Repair Of Security Wall & Main Gate Area Near Cp-2 And Provn Of Additional/Alteration Of Jcos Bathroom (Two) Near Bldg No P-72,P-73 P-76 & P-77 At Guard Under Ge (Army) No 1 Jodhpur. Job No (I) 25/Sr(Bldg)/Jodh/2026-27 (Ii) 18/Rw/Jodh/2026-27

BOQ

Name of Work:- SPECIAL REPAIR OF SECURITY WALL & MAIN GATE AREA NEAR CP-2 AND PROVN OF ADDITIONAL/ALTERATION OF JCOS BATHROOM (TWO) NEAR BLDG NO P-72,P-73 P-76 & P-77 AT GUARD UNDER GE (ARMY) No 1 JODHPUR. JOB No (i) 25/SR(BLDG)/JODH/2026-27 (ii) 18/RW/JODH/2026-27
Sl. No. Item Description
1Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store rubbish off the premises complete all as specified and as directed.
2M&L for 25 mm thick cement concrete 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) as in sub base of flooring, incld. finishing the surface even & rough to receive tiling etc., complete all as specified and as directed.
3M & L for screed bed or bedding layer of mortar 15 mm thick for laying floor finishes etc in cement mortar 1:6 complete all as specified and directed'
4M & L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:3 for backing of Dado/ Skirting complete all as specified and directed
5M & L for anti skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular), joint free, area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
6M&L for glazed colour ceramic tiles (premium quality) of size 600 mm X 300 mm X 7-8 mm, as in vertical surface such as i.e. dado/skirting etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles complete all as specified and directed.
7M&L reinforced cement concrete M-20 type A-1 (using 20 mm graded crushed stone aggregate) as in chajjas, landings, balconies, canopies,deck slabs and in shelves and the like complete all as specified and directed. Note : Reinforcement & form work will be measured & paid seperately under respective item of BOQ.
8M&l for use & waste of rough finished formwork to sides and soffits of floor or roof beams, beam haunchings, columns, girders, bressummers, lintels, cantilevers, shelves ,chajjas including supports, over hangs, etc. also splays between floors and beams, etc.complete all as specified and directed
9M&L for mild steel TMT bars 10mm dia and over grade Fe-500D, cut to length, bent to shape required, including cranking bending spirally for hooping for column,, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete etc all as specified and directed.
10M&L precast cement concrete block masonry using PCC 1:3:6, type C-1 (using 20mm graded crushed stone aggregate) solid blocks, exceeding 10 cm in width and setting in cement mortar 1:6, complete all as specified and directed.
11M&L precast cement concrete block masonry using PCC 1:2:4, type B-1 (using 20mm graded crushed stone aggregate) solid blocks, 10 cm thick (with plain or interlocking joints as directed) and setting in cement mortar 1:4, (with plain or interlocking joints as directed) complete all as specified and directed.
12M&L for 18 mm-20 mm thick Granite (of any type) work ( table rubbed and polished ) in steps, jambs, pillars, window cills cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite ,over & including 15 mm thick screed bed in cement mortor 1:4, rubbing,moulding and polishing complete all as specified and directed.
13Rounding edges of stone slabs one edge,such as in steps cooking platform and other similar situations complete all as specified and directed.
14Taking down carefully cement plaster on stone or brick wall surfaces, dado surfaces ,ceilings ,sunsheds, beams, chajjas, facia, roof projection etc upto cover depth by chipping out lightly including necessary scafolding & raking out joints, hacking for key & scrubbing down with water etc and removing of debris from site, complete all as specified and as directed.
15M&L for 15 mm thick rendering in CM 1:4 (mixed with water proofing compound @ 3%of total weight of cement on external faces) on block masonary / stone masonry/concrete surfaces/roof projections/chajjas finished surface even and smooth without using extra cement including necessary scaffolding provided at site, complete all as specified and as directedNote:Water proofing compound will be measured and paid seprerately under respective item of \\"BoQ\\".
16M & L for rendering 15mm thick on block masonary surfaces in cement mortar 1: 6 on internal faces of walls finished even and smooth without using extra cement complete all as specified and directed
17M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:3 and finished smooth and even in ceiling without using extra cement. complete all as specified and directed
18M&L for preparation of new plastered surfaces of wall and applying with 2.0 mm thick(minimum) wall care putty including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of oil bound distemper (shade or tint as approved by GE), over a coat of primer on walls surface complete all as specified and as directed
19M & L for applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (company Depot Tinted) with silicon additives @ 1.43 litre/ 10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed
20M & L for preparing new plastered surfaces of ceilings and applying two coat of distemper oil emulsion over a coat of primer and 2mm thick wall care putty complete all as specified and directed.
21M&L for complete removal of old/existing treatment from walls (any number of layers) by scrapping with steel scrappers or any other means, including filling depressions of scrapped surfaces with preparation of plastered surfaces and apply two coats of distemper oil emulsion (OBD) over a coat of chalk whitening primer and a layer of wall care putty (not less than 2.0 mm thick )applying by pump roller applicator of any shade or tint complete all as specified & directed
22M&L for preparation of old decorated plastered surfaces of ceiling including cornices,pilastered etc. by brooming down or steel wire brushing, scraping down smoke soot, moulds, moss and efflorescent salt and trading oil and greasy spots include filling cracks & depressing by white cement putty and applying two coat of oil bound distemper (OBD) on ceiling surface complete all as specified and directed.
23Taking down chowkhats or frames with shutters (without taking off shutters from the frames) not exceeding 1.50 sqm each and removing from site and making good disturbed surface of walls in cement mortar (1:3) complete all as specified & directed..
24Taking down steel windows/ vents & remove from site and making good disturbed surface of walls in cement mortar (1:3) complete all as specified & directed.
25S & F solid PVC door frame of size 50mm X 47mm made out of 5mm plain colour PVC sheet reinforced with mild steel square tubes suppyling & fixing in opening as per specification & drawing complete all as spcefied and directed by Engineer-in-Charge.
26S & F for factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of mild steel tube for top and bottom rails. mild steel framed shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, paneling of plain colour PVC sheet to be fitted in the MS framed welded/sealed to stiles & rails with suitable PVC sheet beading & joined together with solvent cement complete all as fixing in the frame at site as per specification and drawing complete all as specified and as directed.
27Cutting holes in brick work built in cement mortar for inserting hold fasts and making good dismantled portion in cement mortar 1:3 or cement mortar 1:2:4 Type B-1(using 20 mm graded crushed stone aggregate) as required not exceeding half brick complete all as specified and directed .
28M&L for hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde E-165 complete all as specified and as directed.
29S&F for powder coated (minimum thinkness of powder coating is 50 micron) anodized Aluminium Frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
30S&F for powder coated (minimum thinkness of powder coating is 50 micron)anodized aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55Kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluninium fittings such as peg stays 150mm long (1 No), hinges type B-21 100 mm long (2 No), suitable handle (1 No) in each shutter complete all as specified and directed.
31S&F for anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed with necessary H/F channel etc to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge.
32S&F 5 mm thick figured glass, pin headed type and with aluminium beading in squares or rectangles not exceeding 0.5 Sqm in each pane or in the form of louvers complete all as specified and directed by Engr-in-charge.
33S&F Aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified and directed by Engr-in-charge.
34S&F 100 mm long medium weight, cold rolled stainless steel butt hinges complete all as specified and directed by Engr-in-charge.
35S&F 200mm long aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed by Engr-in-charge.
36S&F 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed by Engr-in-charge.
37S&F 150 mm long aluminium handles, fabricated type, anodised complete all as specified and directed by Engr-in-charge.
38Demoltion of cement concrete padding of water proofing treatment from roof existing complete removal of old existing treatment of roof of any thickness ,plastering, leaping plaster of any thickness cutting & up rooting tree roots/Vegitable growth pading taking down bituminous polythene sheets plaster etc overall thickness not.exceeding 200mm , cleaning of concete surfaces by wire brushres scrubbing down water and removing the debris from the premises upto 500m from the MOD land including cleaning/washing down and keeping surfaces clean complete all as specified and as directed.
39M & L for plain cement concrete 1:2:4 ,type B-0 (using 12.5mm graded crushed stone aggregate) as in padding, benching, sunken portion etc,on roof surface for correcting/making proper slope on roof,for making good depression/ undulation to make the existing as filling in depression of roof slab etc.,complete all as specified and directed.
40M & L for application of water proofing treatment over non accessible/ non approachable RCC roof slab / chajjah / canopy / parapet wall( horizontal/vertical surface) to be executed through approved applicator of the membrane manufacturer/authorized applicator of the manufacturer with following specification etc complete all as specified and directed :- (i) Cleaning existing surface properly with wire brush .(ii) Rendering / bedding layer of 15 mm thick in CM 1:3 mixed with water proofing compound as per manufacturer instructions laying of water proofing treatment including providing the following stage as roof treatment complete all as specified and as directed by Engr-in-Charge : - (iii) Material and labour for UV stable single component fibre reinforced elastomeric liquid applied waterproofing membrane having solid content of 55% formulated wih PU hybrid polymers and reinforcing acrylic fibres and having sun reflectivity Index (SRI) of 106. The application of the material should be done in three coat (6 hr gap after each coat) on the substrate, applying first self priming coat at ratio of damp proof ultra and water 3:1 then 2 undiluted coat of damp proof ultra obtaining coverage @1 ltr/10 sqft in two coats (10-12 hrs gap between each coat. The vital physical and chemical parameters shall be as under. Min elongationat break of 350%, crack bridging ability of 2.5 mm @650 microns thickness, resists positive hydrostatic pressure of up to 10 bars. The material shall be appliied with brush or roller, complete in all respect as per the direction of Engr-in charge/consultant. Also, proper surface preparation along with covingat corners is must. Note : -(i) The work shall be executed by the authorized applicator of the manufacturer only.(ii) The authorized applicator of manufacturer shall be approved by GE, (iii) The color of final finish shall be decided by the GE. (iv) .WPC shall be measured and paid separately under respective item.
41Supply only integral water proofing compound [ISI marked] of approved make.
42Dismantling water tanks exceeding 500 Ltr but not exceeding 1000 ltr and removing to store complete all as specified and directed by Engr-in-charge.
43S&F rotational moulded polythene water storage tank of capacity 1000 ltrs (Cylindrical/vertical with closed type), triple layer construction, ISI marked, hoisted and fixed in position including 20 mm bore GI nipple complete all as specified and directed
44S&F 25mm bore Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
45S&F 25mm outer diameter CPVC tank adaptor complete all as specified and directed.
46S&F 25mm outer diameter CPVC Ball valve for fixing with CPVC pipe 25mm bore complete all as specified and directed.
47Taking up or down steel tubing/CPVC pipe and connections of 15 mm bore or removal to store complete etc and making good the surface in cement mortar 1:3 complete all as specified & directed.all as specified & directed.
48Taking up or down steel tubing/CPVC pipe and connections of 20 mm bore or removal to store complete etc and making good the surface in cement mortar 1:3 complete all as specified & directed.all as specified & directed.
49Cutting chases, for water tubing or concealed , etc, and making good to facings where required and plastering in cement mortar (1:3) cutting not exceeding 10cm girth in brick walls complete all as specified and directed by Engr-in-charge.
50Supplying and laying of Chlorinated Poly Vinyl Chloride (CPVC) pipes, 20 mm outer dia of pipe, SDR 11 & Plain CPVC SDR 11 including all brass fittings, laid in trenches or ceiling or fixed to wall complete all as specified.
51Supplying and laying of Chlorinated Poly Vinyl Chloride (CPVC) pipes, 25 mm outer dia of pipe, SDR 11 & Plain CPVC SDR 11 including all brass fittings, laid in trenches or ceiling or fixed to wall complete all as specified.
52S&F in repair Stainless steel soap dish, size 28 x 11.5 x 9 cm, providing ample space for holding two bars of soap, fixed with brass screws or embedded in wall complete all as specified and directed.
53S&F in repair stop valve fancy type, brass chromium plated with long shank and cup (concealed type) 15 mm bore screwed down high pressure with lever handle screwed both ends for iron pipe or for unions complete all as specified and as directed.
54S&F in repair angle stop valve with wall flange 15 mm bore of pipe, brass chromium plated, screwed down, high pressure, screwed both ends for iron pipe or for unions and fixed including taking down old stop valve complete all as specified and directed.
55S&F in repair Swan neck pillar taps with aerator, cast copper alloy, with capstan heads, fancy type chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe and fixed for 15mm bore dia of pipe complete all as specified and directed.
56S&F in repair 15 mm bore long body bib tap with wall flange and aerator, brass chromium plated with fancy type and screwed down to 15 mm bore GI tubing or for brass ferrule including taking down old bib cock complete all as specified and directed.
57S&F in repair CP brass health faucet, ABS body, with 1000 mm long SS Braided connection pipe with wall hook suitable for 15mm bore of pipe complete all as specified and as directed.
58S&F in repairs tubular towel rail brass chromium plated towel rail , 20 mm dia ,D-type 600 mm long between flanges fixed with and including chromium plated brass screw & wooden /plastic cleats complete set all as specified and directed.
59S&F brass chromium plated overhead shower rose 120 mm dia with 3 flow with swivel joint, including 600mm shower arm with wall flange, fixing to steel pipe or union including taking down old shower rose etc complete all as specified and directed.
60S&F 50mm bore high density polyethylene pipes (HDPE) of pressure rating 6 Kgf/ Sq. Cm., fixed complete to walls, ceilings or in floors etc complete all as specified and as directed.
61M&L for 32mm bore Brass chromium plated Bottle trap for wash basins with inlet and outlet screwed for pipe or connections incl necessary packing union and cap etc complete all as specified and directed.
62S&F in repair 600mm x 450mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC building board fixed to wooden plugs with chromium plated brass screws and cup washers etc complete all as specified and directed.
63S&F in replacement white vitreous china squatting pan \\"Orissa pattern\\" of size 580 mm X 440 mm with integral foot rests (excl fixing bolts, flushing cistern and flush pipe) including provision of cement concrete bedding 1:5:10 type E2 while making good to disturb floor complete all as specified and as directed.
64S&F in replacement vitreous China wash down water closet type (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe), including connection to drain (or outgoing pipe, and to flushing pipe & antisyphonage pipe etc with aluminium hinging device including plastic water closet seat cover,black ,closed pattern with flat bottom and mild steel CP or aluminium hinging device for pedestal pan complete all as specified & directed.
65S&F in repair Vitreous China Counter Wash basins, 560 x 400 x 205 mm, oval or rectangular shape, to be fixed in granite platform including cutting of granite slab complete all as specified and directed.
66S&F in repair PVC flushing cistern 10 ltr capacity valve less syphonic action type low level with and including ball valve float and handle, PVC flush pipe 32 mm bore & PVC connection 15 mm bore 450 mm long with PTMT nuts and brackets complete set & making good disturbed surface with CM 1:3 complete all as specified and directed.
67S & F PVC connections 15mm dia , 450mm long, with PTMT nuts & washers at both ends complete all as specified and directed.
68S&F 32mm dia waste fittings, brass, chromium plated for glazed ware sinks, basins, etc with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed.
69S&F wall mounted liquid soap dispenser PTMT of good quality complete all as specified and directed.(Minimum weight 105gms)
70M&L for 75mm dia of outlet PVC(SWR) floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) for 75 mm bore of pipes complete all as specified and as directed
71M&L for 75mm dia of outlet PVC(SWR) multi floor trap, with grating including jointing with solvent cement fixed in cement concrete type B-1 (1:2:4) for 75 mm bore of pipes complete all as specified and as directed
72S&F PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed.
73S&F 75 mm bore PVC (SWR) bends of any radius with access door complete all as specified and directed.
74S&F 110 mm bore PVC (SWR) bends of any radius with access door complete all as specified and directed.
75M&L for 75 mm bore PVC cowls complete all as specified and directed.
76M&L for 110 mm bore PVC cowls complete all as specified and directed.
77S & F for 75 mm bore, PVC (SWR) pipes, single socketed, in any length, with rubber ring joints fixed on walls including PVC clamps fixed to wall properly including fixing of pipe with PCC (1:2:4) complete all as specified & directed.
78S & F for 110mm bore, PVC (SWR) pipes, single socketed, in any length, with rubber ring joints fixed on walls including PVC clamps fixed to wall properly including fixing of pipe with PCC (1:2:4) complete all as specified & directed.
79S&F 110mm dia PVC Couplers for connecting with EWC with PVC SWR pipe complete all as specified and directed.
80S&F 110mm dia PVC reducers complete all as specified and directed.
81S&F 110 mm bore PVC (SWR) branch piece single (Single `Y') equal or unequal with access door complete all as specified and directed.
82S&F 110 mm bore PVC (SWR) branch piece double (Double `Y') equal or unequal with access door complete all as specified and directed.
83S&F Stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof suitable for 75 mm bore of pipe as specified and directed.
84Cutting in to existing manhole for connecting new drains,making good to pipe and rendering ,cutting out existing benching and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished ,and reforming benching as required for 150mm/200mm/300mm complete all as specified and as directed
85M&L 7.5cm thick Sand stone slabs in sun-shades, chajjas, shelves, cills, landings, cover stones, templates, etc. not exceeding 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in lime mortar 1:2 or cement mortar 1:4. complete all as specified and directed.
86Demolition of plain cement concrete(un-reinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) and removal unserviceable materials, debris and rubbish to a distance out side MD land complete all as directed.
87M&L for 75 mm thick, PCC 1:4:8, type D-2( using 40mm graded crushed stone aggregate) as in sub base, surface finished fair and even complete all as specified and as directed.
88M&L for laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed.
89M& L for cement concrete 1:2:4,type B-1( using 20mm graded crushed stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs for filling sides of interlocking paver block , water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including formwork complete all as specified and as directed by Engr - in - Charge.
90M & L for 75 mm thick plain cement concrete (1:3:6) mix, type C-1 (using 20mm graded crushed stone aggregate) as in plinth protection including 75 mm thick 40 mm graded dry brick aggregate well rammed ,consolidated and groted with fine sand , finishing the surfaces even and fair without using extra cement, including 10 mm wide, 50mm deep joints made at 3.00 m in length and filled with bitumen 85/25 grade and sand in the ratio 1:3 including necessary form work , complete all as specified and directed.
91Demolition of brick/block or stone/boulder masonry walling built in cement mortar including all quoins arches pillars etc and removal unserviceable materials, debris, rubbish to out side MD land complete all as specified and as directed.
92M&L for squarred rubble walling Jodhpur type regular coursed well bonded ,bedded and solidly hearted built in cement mortar 1:6 complate all as specified and directed.
93M&L for squarred rubble walling Jodhpur type regular coursed well bonded ,bedded and solidly hearted built in cement mortar 1:6 but except stone including cleaning, removal of CM from existing complate all as specified and directed.Note : Stone retrived from ser item No 91 of BOQ here-in before
94M&L for 50 mm thick Jodhpur sandstone Jafri/Jaali of approved quality, colour, texture and design, machine cut and accurately carved/drilled to the approved pattern and drawings including making all perforations, curves, edges, grooves and rebates, dressing and smooth finishing of all exposed surfaces, fixing in position with stainless steel clamps/anchors, approved fixing material and necessary supports, including cutting, fitting, wastage, scaffolding and all incidental works, complete in all respects as directed by the Engineer-in-Charge.
95Extra over squared rubble stone walling Jodhpur type regular course for hammer dressing to face of stone with max depression on face from a straight edge not exc 20mm and dressing complete to squared rubble walling, regular coursed, Jodhpur typeall as specified and directed.
96M&L for 40 mm thick Kadau stone facing/cladding on RCC/brick masonry pillars, of approved quality, colour, texture and finish, in approved Kadau stone, properly dressed and machine/hand cut to required dimensions, fixed over prepared surface with cement mortar of approved proportion and suitable stainless steel clamps/anchors wherever required, including all cutting, fitting, corner and edge treatment, raking and pointing of joints with cement mortar, scaffolding, curing, wastage and all incidental works, complete in all respects as directed by the Engineer-in-Charge.
97Providing, fabricating and fixing heavy-duty mild steel sliding entrance gate for Army Unit, of approved design, size and pattern, fabricated from suitable mild steel hollow/box sections, angles, flats and plates of approved sizes and thicknes, comprising outer frame, intermediate horizontal/vertical members, stiffeners and necessary bracing, accurately cut, welded and fabricated true to line, level and alignment; complete with heavy-duty mild steel/galvanized sliding track, bearing-type rollers/wheels, guide rollers, end stoppers, suitable locking arrangement, handles, tower bolts, brackets, cleats, base plates, nuts, bolts and all necessary hardware and fittings.The gate shall be properly ground, dressed and finished, including surface preparation, one coat of approved metal primer and two coats of approved synthetic enamel/PU paint, including all cutting, drilling, welding, fitting, transportation, scaffolding, wastage and all incidental works, complete in all respects as directed by the Engineer-in-Charge.
98M & L for 30 mm thick Jodhpur sandstone Patti facing on external walls of entrance gate/boundary wall, in approved colour, shade, texture and finish, comprising machine-cut and accurately dressed natural Jodhpur sandstone Pattis of approved width and length, laid true to line, level and plumb over prepared masonry/RCC surface with cement mortar of approved proportion, including bedding, jointing and pointing of joints, necessary cutting, fitting, corner and edge treatment, scaffolding, curing, wastage and all incidental works, complete in all respects as directed by the Engineer-in-Charge.
99Providing and fixing illuminated stainless steel unit emblem/logo of approved design, pattern and dimensions on stone-clad entrance wall, comprising 3 mm thick SS 304 grade sheet, accurately laser-cut to approved emblem/logo, with suitable 3-dimensional built-up/raised profile, including SS mounting frame, brackets, spacers and concealed fixing arrangements. The emblem/logo shall be provided with concealed IP-65 rated LED backlighting with suitable LED modules/strip, SMPS/driver, wiring, connectors and necessary electrical accessories, complete with provision for concealed cable routing, fixing and testing, including all cutting, drilling, scaffolding and incidental works, complete in all respects as directed by the Engineer-in-Charge.
100Racking out joints/ pointing to squared rubble or polygonal rubble un-coursed or brought up to courses masonry built in cement mortar or cement lime mortar, coursed or un-coursed in walls not less than 12mm deep, washing the joints, removing rubbish off the premises and keeping the surface to pointed or plastered wet for two days prior to re-pointing or plastering complete all as specified & directed.
101M&L for Keyed pointing to square rubble masonry Jodhpur type regular course in cement mortar 1:3 complete all as specified & directed.
102M&L preparation of new steel surface of any description, over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint (ordinary tint) over & including a coat of red- oxide primer complete all as specified and as directed.
103Excavating in post holes (of similar holes) each n. Exc. 0.50 cum getting out in any type of soil, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exc 25cm, watering and removing surplus soil to a distance n. Exc. 50m and making good surface complete all as specified and directed.
104M &L for plain cement concrete 1:3:6 ,type C-2 (using 40 mm graded crushed stone aggregate) as in foundations,filling & mass concrete for fencing posts, foundation of pole ,struts & stay assembly etc complete all as specified and directed.
105M&L for rolled mild steel in roof trusses (framed), trussed purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.conforming to Fe 410-W (Gde-E- 250) quality- A complete all as specified and directed.
106S&F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa & minimum AZ @150 gm/Sqm( be coated with hot dip alloy of 55 % aluminium, 43.5% Zinc, 1.5% Silicon and finished with resin coat on both surface @ 150 gm/Sqm of coating both surfaces) as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified & directed.
107M&L for stone finished exterior grade wall tiles( size 600 mmX 300 mm) X 7 to 8 mm thick , as in vertical surface such as dado/skirting etc ,set and jointed in neat cement slurry and pointed in colour cement to match the tiles, over & including 10 mm thick rendering in cement mortar 1:4 complete all as specified and directed
108Taking down carefully alluminium / copper point wiring complete for light, fan, socket or power point etc with such as fitting and fixture such as switches, sockets, ceiling rose, lamp holders, brackets, pendent, regulators, sockets ,light fittings etc., aluminium conductor cable with and including wooden batten or FR PVC conduit and its accessories such as wooden gutties, rawl plugs, GI screws, aluminium clips, nails etc complete and removing the material from site and making good the disturbed surface match the existing finishes of wall / floor/ ceiling etc as original i.e. brick work, plastering, white washing, OBD etc as required, complete all as specified and directed.
109M & L for conduit point wiring complete with multistranded copper conductor 1.5 Sqmm PVC insulated unsheathed single core FRLS cable 1100 volt grade, confirming IS 694 & colour code in conduit system of wiring, drawn through in and including non-metalic PVC concealed (including cutting chases and make good the distrubed surfaces ) conduit of size not less than 20 mm dia medium grade as required as site, totally concealed in walls / and surface on floors / ceiling or fixed on surface of walls / columns / beam / tie beam etc by means of saddles and clips etc including all conduit accessories / fittings / junction boxes / inspection covers etc of heavy grade, ISI marked and sunk terminal boxes of CI or 16 SWG pressed steel housing, totally concealed in walls with 3mm thick industrial laminated sheet top cover, fixed flush with wall surface by means of brass screws and sunk / cup washers, for mounting of switches, sockets fan regulators etc including 1.5 Sqmm FRLS PVC insulated, unsheathed flexible multi stranded copper conductor cables as continuous earth wire connected to metallic bodies of luminaries / fans etc at one end and to common earth dolly at other end suitable for One light/fan/exhaust fan point controlled by one, one way switch, complete all as specified and directed.The rates of chase cutting on wall done concealed conduit and steel terminal boxes are included in the unit rates all as specified and directed by Engr-in-Charge.
110All as per item no. 109 here-in-above but one 3 pin 5 or 6 Amps socket outlet on independent board.
111All as per item No 109 above but with using 4.0 Sq mm single core multistanded copper conductor cable (FRLS) and 4.0 sq mm PVC insulated unsheathed stranded copper conductor(FRLS) for common earth wire for 6 pin 16 Amp socket outlet on independent board .
112S&F switch piano, flush type, single pole, one way, 6 Amps, 230 Volts complete all as specified and as directed.
113S&F switch piano, flush type, single pole, one way, 16 Amps, 230 Volts complete all as specified and as directed.
114Supply and fix socket out let 2 in 1, 3 pin, 6 amp suitable for 6 Amp plug top 230 V complete all as specified & directed.
115Supply and fix socket out let socket out let 2 in 1, 3 pin, 6 and 16 amp flush type suitable for 16 Amp plug top multipurpose 230 V, complete all as specified & directed.
116Supply and fixing ceiling rose 3 terminals/PVC/Polycarbonate, isolated body complete all as specified and directed.
117Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor of suitable size from ceiling rose complete, 4 ft long, complete all as specified and as directed.
118S&F lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
119Supply ,fixing & commissioning LED street light fitting 36 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection single peice pressure dia cast aluminium alloy housing high grade powder coated finish with heat resistant toughned clear glass cover for lamp and contror gear compartment with high voltage surge protection device upto 4.5 KV, with & including bracket made of GI pipe light grade 1.60 Mtr long of size 40 mm bore, bend to shape as per site requirement fixed to pole/wall with flat iron clamp size 40 x 6 mm -02Nos with suitable bolts, nuts, washers etc including two coats of synthetic enamel aluminium paint over a coat of red oxide primer on exposed surface of mild steel surface and conductor to fitting with 3 core 1.5 sqmm PVC insulated cable complete all as specified and directed.
120S&F and testing factory made sheet metal enclosure for MCB DB SPN 8 way 240 volt with double door, IP - 43 protection duly fixed/concealed in wall complete and making good disturbed surfaces of wall, floor etc including necessary connection lugging with copper lugs pin/ring type all as directed by Engineer-in-Charge.
121S & F for 5-32 Amps ISI marked MCB 240V,, Single pole \\"C\\" series and current carrying capacity 10KA with over load and short circuit protection, complete all as specified and directed by Engr-in-charge.
122S & F for MCB Single pole & neutral \\"C\\" series 40 Amps ISI marked and current carrying capacity 10KA with over load and short circuit protection, complete all as specified and directed by Engr-in-charge.
123Supply, laying , jointing & testing LT cable XLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty) with standard aluminium conductor,1100 Volts grade of cross sectional area 10 Sqmm 2.0 core.laid in trenches/ducts /encased in GI pipe /fixed to pole including taking down existing cable complete all as specified and directed. Note: Earthwork, RFR, removing of excavated soil, precast concrete cable cover, sand for cusioning of cable & GI protection pipe shall be measured and paid seperately under respective of BOQ.
124S&F electric storage water heater of capacity 25 litres BEE 5 star rated including proper installing arrangment on wall surface with suitable Anchor bolt fatser and Geyser connections for hot and cold water supply made of stainless steel wire braided connrtector with chrome finish heavy duty nuts of 15mm size with suitable lengh etc complete all as directed by Engineer-in-Charge.
125M&L for earthing complete with galvanised steel earth electrode 60cmx60cmx6mm buried directly in ground vertically to depth not less than 2.25m below normal ground level with top edge of the earth plate at a depth not less than 1.5m below ground level connected to and including GI earth lead wire 4 mm dia by means of nuts, bolts, check nuts and washer etc, made of GI and connected to test point and earth dolly all as shown in electrical plate No. 3 SSR Part-I 2009 and specified or indicated including excavation and earthwork in any type of soil PCC (1:3:6) Type C1 in chamber, precast RCC 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4.00 mm dia with cast iron frame, funnel with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 15mm bore medium grade GI protection pipe, test point etc. including taking down existing earthing complete all as specified and directed. Note:- (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead. Please Enable Macros to View BoQ information
126M&L for earthing complete with galvanised steel earth electrode 60cmx60cmx6mm buried directly in ground vertically to depth not less than 2.25m below normal ground level with top edge of the earth plate at a depth not less than 1.5m below ground level connected to and including GI earth lead wire 4 mm dia by means of nuts, bolts, check nuts and washer etc, made of GI and connected to test point and earth dolly all as shown in electrical plate No. 3 SSR Part-I 2009 and specified or indicated including excavation and earthwork in any type of soil PCC (1:3:6) Type C1 in chamber, precast RCC 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4.00 mm dia with cast iron frame, funnel with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 15mm bore medium grade GI protection pipe, test point etc. including taking down existing earthing complete all as specified and directed. Note:- (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58294233
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 33.74 Lakhs
LAST DATE 20-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Special Repair Of Security Wall & Main Gate Area Near Cp-2 And Provn Of Additional/Alteration Of Jcos Bathroom (Two) Near Bldg No P-72,P-73 P-76 & P-77 At Guard Under Ge (Army) No 1 Jodhpur. Job No (I) 25/Sr(Bldg)/Jodh/2026-27 (Ii) 18/Rw/Jodh/2026-27
Basic Detail
Tender No GE/JODH (A) No 1 OF 2026-27 (9488/E8)
Bidding Type Tender
Location
City Jodhpur
State Rajasthan
Key Dates
Publish Date 30 Oct 2026
Submission Date 20 Nov 2026
Open Date 27 Nov 2026
Finance
Tender Value 33.74 Lakhs
Tender Fee 500
EMD 67480
Exemption Available
Document List
BOQ_893489.xls
e2608064-5785-4fb0-8385-73c12b4b3749.html
TENDERDOCUMENTS.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 30, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 20, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Nov 27, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 17 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_893489.xls

html

e2608064-5785-4fb0-8385-73c12b4b3749.html

pdf

TENDERDOCUMENTS.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender