Tender For Repair/Maintenance Of Certain External Water Supply And Connected Works At Nscb, Nsry Sea Water Pump House And Mc Det, Samudrika, Navy Park And Sagar Vihar Area Under Ge Haddo, Sri Vijaya Puram
Tender Value
40 Lakhs
Estimated cost
Bid Submission
19 Nov 2026
18 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
South Andamans → Andaman And Nicobar Islands
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Maintenance Of Certain External Water Supply And Connected Works At Nscb, Nsry Sea Water Pump House And Mc Det, Samudrika, Navy Park And Sagar Vihar Area Under Ge Haddo, Sri Vijaya Puram
BOQ
| Sl. No. | Item Description |
| 1 | M&L for Excavation in trenches not exc 1.5 M deep and 1.5 M width and getting out in soft or loose soil for foundation of poles (or) cable laying complete all as specified and directed. |
| 2 | M&L for Returning, filling incl spreading, levelling, watering and well ramming layers not exc 25 M for cable laying complete all as specified and directed. |
| 3 | M & L for Removing/excavated soil to a distance not exc 50 M and depositing where directed at a level not exc 1.5 M above the starting point complete all as specified and directed. |
| 4 | M & L for 80 mm dia galvanized steel tubing, medium grade, with all fittings and laid on floor/ in trenches, ducts etc or fixed to walls and ceilings including taking down old unserviceable pipe complete all as specified and as directed. |
| 5 | M & L for 50 mm dia galvanized steel tubing, medium grade, with all fittings and laid on floor/ in trenches, ducts etc or fixed to walls and ceilings including taking down old unserviceable pipe complete all as specified and as directed. |
| 6 | M & L for 40 mm dia galvanized steel tubing, medium grade, with all fittings and laid on floor/ in trenches, ducts etc or fixed to walls and ceilings including taking down old unserviceable pipe complete all as specified and as directed. |
| 7 | M & L for 25 mm dia galvanized steel tubing, medium grade, with all fittings and laid on floor/ in trenches, ducts etc or fixed to walls and ceilings including taking down old unserviceable pipe complete all as specified and as directed. |
| 8 | S & F 50 mm dia outer dia CPVC pipes SDR 13.5 and plain CPVC SDR 11 fittings on wall / ceiling/ floor including suitable fittings as requied complete all as specified and directed. |
| 9 | S & F 40 mm dia outer dia CPVC pipes SDR 13.5 and plain CPVC SDR 11 fittings on wall / ceiling/ floor including suitable fittings as requied complete all as specified and directed. |
| 10 | S & F 25 mm dia outer dia CPVC pipes SDR 13.5 and plain CPVC SDR 11 fittings on wall / ceiling/ floor including suitable fittings as requied complete all as specified and directed. |
| 11 | S & F 20 mm dia outer dia CPVC pipes SDR 13.5 and plain CPVC SDR 11 fittings on wall / ceiling/ floor including suitable fittings as requied complete all as specified and directed. |
| 12 | S & F Gate Valve of 50 mm dia, ISI marked, heavy duty brass, including taking down old unserviceable one complete all as specified and as directed. |
| 13 | S & F Gate Valve of 40 mm dia, ISI marked, heavy duty brass, including taking down old unserviceable one complete all as specified and as directed. |
| 14 | S & F Gate Valve of 25 mm dia, ISI marked, heavy duty brass, including taking down old unserviceable one complete all as specified and as directed. |
| 15 | M & L of PP-R Ball valves (brass insert) of 50 mm dia as per requirement of the site including taking down old unserviceable one all as specifed and directed by Engr in Charge. |
| 16 | M & L of PP-R Ball valves (brass insert) of 25 mm dia as per requirement of the site including taking down old unserviceable one all as specifed and directed by Engr in Charge. |
| 17 | M & L of PP-R Ball valves (brass insert) of 20 mm dia as per requirement of the site including taking down old unserviceable one all as specifed and directed by Engr in Charge. |
| 18 | M & L for taking up unserviceable cast iron water mains of size 100 mm dia (including all fittings), with spigot and socket ends and lead joints including burning out joints all as specified and directed by Engr In Charge. |
| 19 | Marterial, labour and laying in replacement of Cast iron pipe of 100 mm dia (4\\") bore spigot and socket type type centrifugally cast (spun), class A, in any length, laid in trenches/ floor/ under road/ footpath etc complete all as specified and directed. ( Note :- New lead joint will be measured and paid separately under relevant items under Sch) |
| 20 | S & F CI Bends upto 150 m bore (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch, double branch, cross (for all sockets or socket & spigot, flanged pipes) collars etc all as specified and directed by Engr In Charge. |
| 21 | M & L for new lead joint for CI Pipe/ fittings up to 150 mm boreall as specified and directed by Engr In Charge. |
| 22 | M & L for stopping leakage by repairing the lead for CI Pipe/ fittings all as specified and directed by Engr In Charge. Note:- Necessary earth work will be measured and paid separately under relevant item of Sch |
| 23 | S&F Pressure gauge 4\\" dial 0-14 kgs rating, incl cutting, welding of pipie line all as specified and as directed by Engr In Charge. |
| 24 | S & F cast iron sluice valve, 100 mm size or bore, class PN 1.6, ISI marked, heavy duty with brass spindle, operating wheel, flanged on both ends along with suitable new rubber packing (gasket), stainless steel bolts, nuts & washers and necessary modifications if required for fixing in location including taking down old unserviceable sluice valve of any description complete all as specified and as directed. |
| 25 | Supply and fix in replacement of CI Foot Valve conforming to IS 4038, 80 mm (3”) dia with connected accessories alongwith, nut, bolts, washers complete all as specified & directed. |
| 26 | S&F DOL starter up to 7.5 HP Capacity in Sheet-Steel Enclosure and as per existing make & model Complete all as specified and directed. |
| 27 | Disconnecting/ dismantling 3 phase, 440 volts, 50 cycles electrical motor with centrifugal /monoblock pumpset (electrically and mechanically) from its location and shifting to work shop, opening the motor end cover, taking out rotor, taking out burnt stator winding, cleaning the stator and rewinding of motor with appropriate gauge, weight and turns of super enamelled copper winding wire using proper Garware insulating paper, insulating with Class I varnish, and oven drying for requisite insulation values, reassembling the motor completely and bringing back to its original location, cleaning the impeller of pump, supply & replace gland rope, greasing, replacement of unserviceable spares of pump, fixing back in position, connecting back electrically and mechanically with proper alignment and testing complete all as specified and as directed for 7.5 HP capacities of centrifugal/ monoblock pumpsets of any make.NOTES: (i) Insulation of winding shall be Class 'B' upto 7.5 HP.(ii) Old material obtained from replacement shall be contractor's property as per Schedule of credit given in tender. |
| 28 | Disconnecting/ dismantling 3 phase, 440 volts, 50 cycles electrical motor with centrifugal /monoblock pumpset (electrically and mechanically) from its location and shifting to work shop, opening the motor end cover, taking out rotor, taking out burnt stator winding, cleaning the stator and rewinding of motor with appropriate gauge, weight and turns of super enamelled copper winding wire using proper Garware insulating paper, insulating with Class I varnish, and oven drying for requisite insulation values, reassembling the motor completely and bringing back to its original location, cleaning the impeller of pump, supply & replace gland rope, greasing, replacement of unserviceable spares of pump, fixing back in position, connecting back electrically and mechanically with proper alignment and testing complete all as specified and as directed for 1.5-4 HP capacities of centrifugal/ monoblock pumpsets of any make.NOTES: (i) Insulation of winding shall be Class 'B' upto 7.5 HP.(ii) Old material obtained from replacement shall be contractor's property as per Schedule of credit given in tender. |
| 29 | M & L for Overhauling of pressure pump set of capacity 1 HP upto 7 stage after removing from base plate disconnecting from pipe line and dismantling pump set, replacing gland packing, gun metal bush, bearing and water seal, Shaft and applying grease etc, reassembling the pump set and refixing back on the base plate and connecting with existing pipe line with nuts, bolts and new gasket including testing the pumping set for full satisfaction of Engg- in -charge, complete all as specified and as directed by Engineer-in-charge. |
| 30 | S & F Pressure switch suitable for 1 HP pressure pump including connected accessories all as specified and directed by Engr In Charge |
| 31 | M & L for checking the leakage from the pressure pump accessories i.e. joints, sockets etc of cap 1 HP, opening the defective parts and refix the same after rectification all as specified and directed by Engr In Charge. |
| 32 | Material and labour for preparation of old painted surface of LT panel (Qty-1) and Control panel/ starter panel for pumping set of cap 7.5 HP (Qty-02) by scaraping out old painted surfaces and painting with spray painting of existing colour synthetic enamel paint over one coat of red oxide primer all as directed by Engr-in-Charge. |
| 33 | M & L for servicing automated water softening Plant of any make, capacity-1000 LPH @ 24 hours re-generation, comprising of Auto Pressure Sand Filter (PSF), Auto activated Carbon Filter ( ACF), Auto water softner, chlorine dozing all as specified and directed by Engr In Charge.(Note:- All the spares required will be measured and paid separately under relevant item of Sch.) |
| 34 | Pebbles |
| 35 | Gravels |
| 36 | Coarse Silex |
| 37 | Fine Sand |
| 38 | Activated Carbon |
| 39 | Cation Resin |
| 40 | Dosing Pump 0-6PLH |
| 41 | Auto/Manual Multiport Valve 25 NB |
| 42 | Softener Plant Panel Board |
| 43 | M & L for cleaning/ servicing the LT Panel/ starter panel, by opening nut, bolts, links any type, loosen contacts, cables, removing the dust from the spares and reassembling/ reconncetion the same incl lugs with the cables as existing all as specified and directed by Engr In Charge. |
| 44 | Taking up old unserviceable water storage tank and S & F 500 Ltrs rotational moulded polyethylene water storage tank double layer, ISI marked, (Cylindrical vertical with closed top) with GI medium grade pipe for inlet, outlet, over flow, checknuts for inlet and outlet, hoisted and fixed in position including 25 mm PTMT Ball valve all as specified of following sizes:- |
| 45 | Taking up old unserviceable water storage tank and S & F 1000 Ltrs rotational moulded polyethylene water storage tank double layer, ISI marked, (Cylindrical vertical with closed top) with GI medium grade pipe for inlet, outlet, over flow, checknuts for inlet and outlet, hoisted and fixed in position including 25 mm PTMT Ball valve all as specified of following sizes:- |
| 46 | Taking up old unserviceable water storage tank and S & F 2000 Ltrs rotational moulded polyethylene water storage tank double layer, ISI marked, (Cylindrical vertical with closed top) with GI medium grade pipe for inlet, outlet, over flow, checknuts for inlet and outlet, hoisted and fixed in position including 25 mm PTMT Ball valve all as specified of following sizes:- |
| 47 | S & F in repairs ball valve/ float valve complete with polythene float, fly nut for GI Pipe connection including necessary GI fittings such as elbow, nipple etc of size 25 mm dia including taking down old float valve all as specified and as directed |
| 48 | M&L for the Service tank of capacity upto 500 Ltrs of PVC/ RCC Service tank situated at various place at any height, removing the inlet and outlet coupling connections and cleaning and removing all dirty muddy water from the service tank PVC/ RCC by using wire mesh brushes, brooms including scraping the all scale formation, neatly cleaning inside surfaces by using bleaching powder. Details of tanks like date of cleaning, capacity of tanks and due date for cleaning etc shall be written on the out side of the tank with synthetic enamel paint with letter size 10 cm in white colour, over a black background of size 60 x 40 cm including cleaning of bottom surfaces of platform, RCC/ PCC slab including replacement of the unserviceable defective inlet and outlet suitable size coupling and fittings, etc complete all as specified and directed. |
| 49 | M&L for the Service tank of capacity 700 Ltrs to 1000 Ltrs of PVC/ RCC Service tank situated at various place at any height, removing the inlet and outlet coupling connections and cleaning and removing all dirty muddy water from the service tank PVC/ RCC by using wire mesh brushes, brooms including scraping the all scale formation, neatly cleaning inside surfaces by using bleaching powder. Details of tanks like date of cleaning, capacity of tanks and due date for cleaning etc shall be written on the out side of the tank with synthetic enamel paint with letter size 10 cm in white colour, over a black background of size 60 x 40 cm including cleaning of bottom surfaces of platform, RCC/ PCC slab including replacement of the unserviceable defective inlet and outlet suitable size coupling and fittings, etc complete all as specified and directed. |
| 50 | M&L for the Service tank of capacity 2000 Ltrs to 3000 Ltrs of PVC/ RCC Service tank situated at various place at any height, removing the inlet and outlet coupling connections and cleaning and removing all dirty muddy water from the service tank PVC/ RCC by using wire mesh brushes, brooms including scraping the all scale formation, neatly cleaning inside surfaces by using bleaching powder. Details of tanks like date of cleaning, capacity of tanks and due date for cleaning etc shall be written on the out side of the tank with synthetic enamel paint with letter size 10 cm in white colour, over a black background of size 60 x 40 cm including cleaning of bottom surfaces of platform, RCC/ PCC slab including replacement of the unserviceable defective inlet and outlet suitable size coupling and fittings, etc complete all as specified and directed. |
| 51 | M&L for the Service tank of capacity 5000 Ltrs of PVC/ RCC Service tank situated at various place at any height, removing the inlet and outlet coupling connections and cleaning and removing all dirty muddy water from the service tank PVC/ RCC by using wire mesh brushes, brooms including scraping the all scale formation, neatly cleaning inside surfaces by using bleaching powder. Details of tanks like date of cleaning, capacity of tanks and due date for cleaning etc shall be written on the out side of the tank with synthetic enamel paint with letter size 10 cm in white colour, over a black background of size 60 x 40 cm including cleaning of bottom surfaces of platform, RCC/ PCC slab including replacement of the unserviceable defective inlet and outlet suitable size coupling and fittings, etc complete all as specified and directed. |
| 52 | M&L Islolate water supply valve to the UG sump of 50000 Gallons capacity at Navy Park Pump House at any height cleaning and removing all dirty muddy water from the sump/OH Tank , scrapping/scrubbing the inside walls by using wire brushes, brooms to remove all fungus scale formations, cleaning the inner surfaces of sumps with use of bleaching powder and washing internal surfaces of the walls and applying one coat of white wash to the internal surface of sump/OH tanks. Details of tank like Date of cleaning, Due date, and capacity of tank etc shall be written on the out side of the tank with synthetic enamel paint with letter size 20 cm in white colour, over a black background of size 100 x 60 cm complete all as specified and directed by Engineer-in-Charge. |
| 53 | M&L Islolate water supply valve to the Over head tank of 25000 Ltrs capacity at Navy Park Pump House at any height cleaning and removing all dirty muddy water from the sump/OH Tank , scrapping/scrubbing the inside walls by using wire brushes, brooms to remove all fungus scale formations, cleaning the inner surfaces of sumps with use of bleaching powder and washing internal surfaces of the walls and applying one coat of white wash to the internal surface of sump/OH tanks. Details of tank like Date of cleaning, Due date, and capacity of tank etc shall be written on the out side of the tank with synthetic enamel paint with letter size 20 cm in white colour, over a black background of size 100 x 60 cm complete all as specified and directed by Engineer-in-Charge. |
| 54 | M&L Islolate water supply valve to the Sump Well of dia upto 2.7 mtr and depth 15.0 mtr in NSCB Island at any height cleaning and removing all dirty muddy water from the sump/OH Tank , scrapping/scrubbing the inside walls by using wire brushes, brooms to remove all fungus scale formations, cleaning the inner surfaces of sumps with use of bleaching powder and washing internal surfaces of the walls and applying one coat of white wash to the internal surface of sump/OH tanks. Details of tank like Date of cleaning, Due date, and capacity of tank etc shall be written on the out side of the tank with synthetic enamel paint with letter size 20 cm in white colour, over a black background of size 100 x 60 cm complete all as specified and directed by Engineer-in-Charge. |
| 55 | Material and labour for preparation of old painted surface of MS structure not more than 10 mtrs for overhead tank for 02 x 2000 Ltrs PVC tanks alongwith stairs at any position incl the suppoting structure also by scaraping out old painted surfaces and painting with two coat of synthetic enamel paint of existing colour etc all as specified and directed by Engr-in-Charge. |
| 56 | Material & labour for laying of Plain or corrugated steel sheets, any thickness as reqd by cutting / making in to the shape providing necessary angular supports and handles with 6 mm dia rod as per the site condition for trench/ chamber cover of sub-station alongwith painting of two coat of synthetic enamel over a coat of one coats of redoxide complete all as specified and directed. |
| 57 | S&F framed bracket of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles as necessary gusset plates, riveting etc as in chamber cover including cutting tops to shape as directed, drilling holes, notching for wire etc., complete all as specified and directed. |
| 58 | Precast cement concrete (PCC) type B1 1:2:4 using 20mm graded aggregate stone for making copings including use and waste of form work complete etc., complete all as specified and directed. |
| 59 | M and L for dismantling old valve chamber and material and labour for construction of block masonry new valve pit chamber of size 600mmx600mmx600mm (internal), 100mm thick PCC 1:4:8 type D2 lean concrete foundation using 40mm graded stone aggregate, providing with old size fly ash bricks masonry wall of 230mm thick built in CM 1:6, rendering 15mm thick in CM 1:6 finished even and smooth using extra cement internally and 20mm thick in CM 1:4 and finished fair and even externally and plaster shall be done 150 mm below ground level, supply and fix 4.00 mm thick MS sheet steel cover fixed on 50X50X6mm angle iron frame embedded in PCC 1:2:4 coping with locking arrangement and MS hold fast and handle made out of 25x6mm flat iron, applying two coats of synthetic enamel paint of approved shade over a coat of primer (red oxide) to all exposed steel surfaces and applying three coats of white wash to exposed plastered surfaces and making good all disturbed suface to match surrounding complete all as specified and as directed . |
| 60 | Earthing complete with galvanised earth plate electrode 60 cm x 60cmx 6 mm thick, buried directly in ground vertically (earth pit not less than 2.25 m deep below ground level) with top edge of the earth plate not less than 1.5m below ground level , connected to GI strip 32 mm x6 mm as earthling lead by means bolts and nuts check nuts and washers of galvanized iron and connected to main switch board including watering arrangement with PCC chamber , MS funnel with wire mesh,. CI cover with frame etc including necessary excavation in any type of strata , returning, filling removal of soil outside MD land ,filling of charcoal and salt complete all as shown in electrical plate No. 3 of MES Sch Part I , connected to Earthing test point all as specified and directed on testing on completion. |
| 61 | Supply, laying, testing and commissioning of 2 core x 10 sqmm LT XLPE insulated, armoured heavy duty electric aluminium conductor cable 1100 Volts grade of following sizes (laid in terenches,ducts,pole,wall etc.) incl taking down old unserviceable cable all as specified and directed. |
| 62 | Supply, laying, testing and commissioning of 4 core x 16 sqmm LT XLPE insulated, armoured heavy duty electric aluminium conductor cable 1100 Volts grade of following sizes (laid in terenches,ducts,pole,wall etc.) incl taking down old unserviceable cable all as specified and directed. |
| 63 | Supply, laying, testing and commissioning of 4 core x 25 sqmm LT XLPE insulated, armoured heavy duty electric aluminium conductor cable 1100 Volts grade of following sizes (laid in terenches,ducts,pole,wall etc.) incl taking down old unserviceable cable all as specified and directed. |
| 64 | Supply, laying, testing and commissioning of 3.5 core x 35 sqmm LT XLPE insulated, armoured heavy duty electric aluminium conductor cable 1100 Volts grade of following sizes (laid in terenches,ducts,pole,wall etc.) incl taking down old unserviceable cable all as specified and directed. |
| 65 | Supply, laying, testing and commissioning of 3.5 core x 50 sqmm LT XLPE insulated, armoured heavy duty electric aluminium conductor cable 1100 Volts grade of following sizes (laid in terenches,ducts,pole,wall etc.) incl taking down old unserviceable cable all as specified and directed. |
| 66 | Supply, laying, testing and commissioning of 3.5 core x 70 sqmm LT XLPE insulated, armoured heavy duty electric aluminium conductor cable 1100 Volts grade of following sizes (laid in terenches,ducts,pole,wall etc.) incl taking down old unserviceable cable all as specified and directed. |
| 67 | Supply, laying, testing and commissioning of 3.5 core x 120 sqmm LT XLPE insulated, armoured heavy duty electric aluminium conductor cable 1100 Volts grade of following sizes (laid in terenches,ducts,pole,wall etc.) incl taking down old unserviceable cable all as specified and directed. |
| 68 | Supply, laying, testing and commissioning of 3.5 core x 150 sqmm LT XLPE insulated, armoured heavy duty electric aluminium conductor cable 1100 Volts grade of following sizes (laid in terenches,ducts,pole,wall etc.) incl taking down old unserviceable cable all as specified and directed. |
| 69 | Supply and laying in trenches or in cable ducts or clamping on wall DWC HDPE pipe of size 40 mm(OD) x 32 mm (ID) along with connected accessories like couplers, bends,end caps etc. for LT cable protection including taking down all as specified and directed.Make: Rex Poly Extrusion Ltd/ Tirupati Plastomatics Pvt Ltd. |
| 70 | Supply and laying in trenches or in cable ducts or clamping on wall DWC HDPE pipe of size 50 mm(OD) x 38 mm (ID) along with connected accessories like couplers, bends,end caps etc. for LT cable protection including taking down all as specified and directed.Make: Rex Poly Extrusion Ltd/ Tirupati Plastomatics Pvt Ltd. |
| 71 | Supply and laying HDPE DWC pipe of size 77mm (OD) x 63mm (ID) along with connected accessories like couplers, bends, end caps etc. for LT/ HT cable protection complete all as specified and as directed by engineer in charge.Make: Rex Poly Extrusion Ltd/ Tirupati Plastomatics Pvt Ltd. |
| 72 | Supply & fix in replacement FRP pole box 170 x 170 x 105 mm consisting of 1 No 50 A 4 pole connector and 1 No 16 A MCB SP including taking down the old/unserviceable junction boxes all as specified and directed. Make : SINTEX Cat No. GS-JB-1414 or equivalent & Make of MCB: L&T/Havells/ Legrand/Indo Asian |
| 73 | Supply & fix in replacement of Cable Junction Box of size 130 x 180 x 77, IP 66 (Grey) with integrated membranes / metric knockouts for cable entry of size upto 10.00 sqmm twin core with earth, Lighting Outgoing cable: 3C x 1.5/ 2.5 Sq.mm cable, Degree of protection: IP66, Lighting MCB Rating: 10A,SP, B-Curve, current carrying capacity: 40A, Material: PC-GFS (polycarbonate) , Weatherproof, resistant to weather influences including taking down the old/unserviceable junction boxes all as specified and directed. Make : Hensel model No DK 1010 G or equivalent. |
| 74 | Supply & fix in replacement of Cable Junction Box of size 155 x 210 x 92, IP 66 (Grey) with integrated membranes / metric knockouts for cable entry of size upto 25 sqmm twin core with earth, Lighting Outgoing cable: 3C x 1.5/ 2.5 Sq.mm cable, Degree of protection: IP66, Lighting MCB Rating: 10A,SP, B-Curve, current carrying capacity: 40A, Material: PC-GFS (polycarbonate) , Weatherproof, resistant to weather influences including taking down the old/unserviceable junction boxes all as specified and directed. Make : Hensel model No DK 1616 G or equivalent. |
| 75 | Supply only of Electronic drivers (as per existing) for illuminating 10 watt LED post top /LED fittings operated at Input AC 185-265V ,50hz output DC-42-65V 300MA P.F 0.95 all as specified and directed. |
| 76 | Supply only of Electronic drivers (as per existing) for illuminating 20-40 watt LED post top /LED fittings operated at Input AC 185-265V ,50hz output DC-42-65V 300MA P.F 0.95 all as specified and directed. |
| 77 | Supply and fixing in replacement of LED Bollard with round top 9/10 W ,220V 50Hz with opal acrylic IP 65 protection along with necessary PCC foundation cable condits for loop in and out , cable connectors complete all as specified and directed. Make Cat No. LBLSN-10-CDL/WW of Crompton graves or equivalent in Bajaj / Havells/ Philips /C&S. |
| 78 | Supply and fixing in replacement outdoor type Decorative Post top for 360° indirect light with IP 65 protection, resistant to impact and corrosion of 240 v,50hz of capacity 40 watt LED suitable for mounting on 60 mm OD pipe on necessasry PCC works complete all as specified and directed. Make:Cat Part No : LPTO-40-CDL-M of CG or equivalent in Philips/C&S |
| 79 | S & F in replacement LED post top lantern of cap 20 watt, IP65 Rated, ideal to light up parks, gardens etc suitable for mounting on 60 mm OD pipe on incl taking down old fittings complete all as specified and directed .Make: CG Cat Part No -LPTH-20-CDL or equivalent in Philips/ C&S/ Havells. |
| 80 | Supply and fixing in replacement of LED floodlight of capacity 150 watt made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 protection, System efficacy ≥ 110/120LPW 10KV included driver including fixing on High mast of any hight or any pole/ wall/ iron structure etc including taking down of the old unserviceable halogen/any type of old unsv light fittings all as specified and directed.Make: Luker Model No :LFLSL150NSG or equivalent model of /Philips/Havells/CG |
| 81 | Supply and fixing in replacement of LED floodlight of capacity 100 watt made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 protection, System efficacy ≥ 110/120LPW 10KV included driver including fixing on High mast of any hight or any pole/ wall/ iron structure etc including taking down of the old unserviceable halogen/any type of old unsv light fittings all as specified and directed. Make: Luker Model No :LFLSL100NSG or equivalent model of /Philips/Havells/CG |
| 82 | Supply and fixing in replacement of LED floodlight of capacity 80 watt made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 protection, System efficacy ≥ 110/120LPW 10KV included driver including fixing on High mast of any hight or any pole/ wall/ iron structure etc including taking down of the old unserviceable halogen/any type of old unsv light fittings all as specified and directed. Make: Luker Model No :LFLSL80NSG or equivalent model of /Philips/Havells/CG |
| 83 | Supply and fixing in replacement of LED floodlight of capacity 50 watt (of any coloured as reqd) made up of pressure die cast aluminium housing with toughened glass and high power LEDs included driver along with mounting bracket including fixing on pole/ wall/ iron structure etc including taking down of the old unserviceable halogen/any type of old unsv light fittings all as specified and directed.Make: Luker Model No : LFLSL50NSG or equivalent model of /Philips/Havells/CG |
| 84 | Supply and fixing of LED street light fixture of capacity 72 watt ,aerodynamically designed for all weather conditions with excellent thermal management, made with pressure die cast housing with toughened glass and high power LED's with secondary optics and IP66 protection. Efficacy > 110/120 LPW, with 10KV SPD including taking down the old unsv light fitting of any type all as specified and directed. Make: Luker Model No :LST072 LN 5Y or equivalent model of /Philips/ Havells/ CG |
| 85 | S & F in replacement of 9 Watts holder type (E22) LED lamp (E22) 230 Volts, 50Hz complete all as specified and as directed. Make :- Philips/ CG/ Havells/ Bajaj |
| 86 | S & F in replacement PVC Insulated and PVC Round Sheathed 2 core 1.0 sqmm Bright Annealed Bare Copper Conductor Heavy Duty Flexible Cables for Voltage Grade 1100 Volts for connection of lights from junction box complete all as psecified and directed. |
| 87 | Taking down old timer panel and supply and fixing of out door type Street light timer Panel /Distribution Boards with pole, panel etc as directed alongwith 65A 3 pole/230 Volts contactor and Digital 24 hrs/ Analog Time Switch, 63 A MCB, Manual and Auto Mode Toggle switch cable connectors, cable gland etc including suitable fixing arrangement with existing pole/ panel all as specified and directed. Make: Cat No. TL065AB0 of indoasian Time lite or equivalent. |
| 88 | M&L for Precast cement concrete (PCC) type B1 1:3:6 using 20mm graded aggregate stone for making copings including use and waste of form work complete etc. including demolition of old concrete complete all as specified and directed. |
| 89 | S&F Drive end bearing of existing make and model as per site requirement for 30 to 125 KVA DG set of any make as existing including main rotor dynamic balancing including taking down old unserviceable item complete all as specified and as directed by Engineer-in-charge. |
| 90 | S&F Non drive end bearing of existing make and model as per site requirement for 30 to 125 KVA DG set of any make as existing including main rotor dynamic balancing including taking down old unserviceable item complete all as specified and as directed by Engineer-in-charge. |
| 91 | Taking down unserviceable self-starter 12 volts for 100 to 125 KVA DG set of any make as existing, from engine, dismantling and opening of stater and armature,replace the wornout carbon brush, pinion,ignition coil bearing,bushing, including servicing, varnishing of stater after repairing assembling,refixed to same position complete all as specified and directed. |
| 92 | Taking down unserviceable self-starter 12 volts for 15 to 30 KVA DG set of any make as existing, from engine, dismantling and opening of stater and armature,replace the wornout carbon brush, pinion,ignition coil bearing,bushing, including servicing, varnishing of stater after repairing assembling,refixed to same position complete all as specified and directed. |
| 93 | Cleaning the radiator intercooler of 15 to 125 KVA DG set of any make as existing by checking and removing the deposited dust, oil welt and carbon deposits etc. with wire brushes, cleaning agents etc. complete all as specified and as directed by Engineer-in-charge |
| 94 | S&F in repairs 4 pole power contactors of auxiliary coil supply of 220 V, 50Hz AC supply with 2 NO + 2 NC contacts, type MCX 33 for AMF panel complete all as specified and as directed by Engineer-in-charge. |
| 95 | S&F in repairs 4 pole power contactors of auxiliary coil supply of 220 V, 50Hz AC supply with 2 NO + 2 NC contacts, type MCX 11 for AMF panel complete all as specified and as directed by Engineer-in-charge. |
| 96 | S& F in replacement of existing radiator of 100–125 kVA DG set with new heavy-duty copper tube/copper-brass radiator suitable for the existing DG engine, complete with radiator core, copper tubes, fins, top and bottom tanks, headers, filler neck, pressure cap, drain cock, inlet and outlet connections, suitable heat-rejection capacity, flexible coolant hoses with heavy-duty clamps, mounting brackets/supports, fan shroud modification and alignment wherever required, necessary MS fabrication, nuts, bolts and fasteners, dismantling and removal of existing radiator, draining and refilling of coolant, cleaning/flushing of cooling system, anti-corrosion treatment, pressure/leakage testing, checking of coolant circulation and engine operating temperature, testing and commissioning of DG set under load, including all materials, labour, tools, plant and accessories, completecomplete all as specified and directed by Engr In Charge. |
| 97 | M & L for supply and fixing Automatic Voltage Regulator of any make/model suitable for 30 to 125 KVA DG set of any make as existing , starting and testing on load all as specified and directed. Make: Altex /Kirlosakr |
| 98 | M&L for carrying out \\"B\\" check for 100 to 125 KVA DG set of any make as existing as per manufacturer's recommendation including replacement of necessary spares and Filters such as Fuel filter, SLO Bypass filter and lub oil filter complete including rectification of minor defects, cleaning of air filters/ breather & coolant tank with air blower, replacement of Engine oil & coolant and tuning of engine all as specified and directed. [Notes: (i) Supply only Engine oil & Coolant shall be measured and paid separately. (ii) Rate quoted shall include for all filters, topping up distilled water in batteries & minor accessories like nuts, bolts, 'O' rings etc.] |
| 99 | M&L for carrying out \\"B\\" check for 15 to 30 KVA (at NSCB Islands and Haddo area) of any make as existing as per manufacturer's recommendation including replacement of necessary spares and Filters such as Fuel filter, SLO Bypass filter and lub oil filter complete including rectification of minor defects, cleaning of air filters/ breather & coolant tank with air blower, replacement of Engine oil & coolant and tuning of engine all as specified and directed. [Notes: (i) Supply only Engine oil & Coolant shall be measured and paid separately. (ii) Rate quoted shall include for all filters, topping up distilled water in batteries & minor accessories like nuts, bolts, 'O' rings etc.] |
| 100 | Supply only Engine oil 15w 40 type:CH4 or CI4 as per requirement and manufacturer recommendation . [Make: Servo/ Valvoline/ Castrol/Mobil] |
| 101 | Supply only concentrated Engine coolant [Make: K-Cool or as recommended by OEM] |
| 102 | S&F battery terminal, brass heavy duty (two nos) complete suitable for fixing on battery poles with nuts and bolts complete including disconnecting and taking down unserviceable battery terminal all as specified and directed. |
| 103 | S&F battery lead copper conductor single core 70 sq.mm, 2 metre long (two nos) complete including soldering of copper lugs including disconnecting and taking down unserviceable battery lead complete all as specified and as directed by Engineer-in-charge. |
| 104 | M&L for removing oil/ grease deposits, oil/ paint/ corrosion flakes and cleaning the external surface & inside and Engine & Alternator etc of 30 to 125 KVA DG set of any make as existing,along with acoustic enclosure., using wire brushes, coarse cloth, cleaning agents etc. and applying two coats of heat retardant paint of approved tint by spray application complete including necessary T&P like spray gun, air compressor etc.complete all as specified and as directed by Engineer-in-charge. |
| 105 | M&L for removing oil/ grease deposits, oil/ paint/ corrosion flakes and cleaning the external surface & inside and Engine & Alternator etc of 15 KVA DG set of any make as existing,along with acoustic enclosure., using wire brushes, coarse cloth, cleaning agents etc. and applying two coats of heat retardant paint of approved tint by spray application complete including necessary T&P like spray gun, air compressor etc.complete all as specified and as directed by Engineer-in-charge. |
| 106 | Dismantling and taking out old unserviceable burnt terminal blocks connectors from mounting base of 30 to 125 KVA DG set of any make as existing Alternator inlet & outlet cables and supply & fixing for Terminal blocks connector and re-connecting of same cables properly including providing of new lugs & alternator top cover farbrication all as specified . |
| 107 | Dismantling of Fuel pump from 30 to 125 KVA DG set of any make as existing for Replacement of FIP Solenoid switch for fuel pump and re-connecting for the same fuel pump properly including all as specified . |
| 108 | Dismantling and taking out old unserviceable water pump for 30 to 125 KVA DG set of any make as existing and M & L for new water pump including all as specified . |
| 109 | Draininng up the fuel tank/Diesel tank in a separate empty barrels, disconnecting the fuel lines from the fuel filters and taking out the fuel tank and clearing internally and remove the accumulated slludge/Sediments and arresting leakages, reconnecting back all the removed fuel lines and mounting the diesel tank its orginal position, supply and replacing the drain plug suitable and including painting of external surfaces by using synthetic enamel paint of two coats over one coat of red oxide primer testing complete for 30 to 125 KVA DG set of any make . |
| 110 | Dismantling,dismounting and transportation of 100-125 KVA DG set of any make as existing, alternator assembly of existing Make of DG Set from its foundation and rewinding of main stator with suitable gauge of 'F' class enamelled winding wire of copper as per OEM recommendations,air drying, insulating varnish and becktrol red,heating insulation etc. and refixing/reassembling the alternator assembly to its foundation including connection,amputation,hot and cold checkups etc.inluding alignment and testing all as specified and directed by Engineer-in-Charge.Note: Rate includes necessary transportation to workshop and back. |
| 111 | Dismantling,dismounting and transportation of 15 to 30 KVA DG Set of any make as existing, alternator assembly of existing Make of DG Set from its foundation and rewinding of main stator with suitable gauge of 'F' class enamelled winding wire of copper as per OEM recommendations,air drying, insulating varnish and becktrol red,heating insulation etc. and refixing/reassembling the alternator assembly to its foundation including connection,amputation,hot and cold checkups etc.inluding alignment and testing all as specified and directed by Engineer-in-Charge.Note: Rate includes necessary transportation to workshop and back. |
| 112 | S & F stop seloniod switch suitable for 15 KVA DG Set of Make-Greaves |
| 113 | Supply and connect and test lead acid battery heavy duty 12 volt 150 AH complete with initial charging including taking down old battery complete all as specified. Make : Exide/Amaron |
| 114 | Supply and connect and test lead acid battery heavy duty 12 volt 120 AH complete with initial charging including taking down old battery complete all as specified. Make : Exide/Amaron |
| 115 | Supply and connect and test lead acid battery heavy duty 12 volt 75 AH complete with initial charging including taking down old battery complete all as specified. Make : Exide/Amaron |
| 116 | Supply and fix against repairs SMPS/ Automatic battery charger 240 V input , 12 V / 10 - 15 Amps output with auto cut off and floating with selector switch and indicators, set of fuses complete all as spcified and directed by Engineer-in-charge. |
| 117 | Dismantling and taking down Engine of capacity 30 to 125 KVA DG set of any make as existing, any cylinder, 1500 RPM, water cooled by dismantling/strip opening of the DG set for Top overhauling by removing the cylinder heads, piston, connecting rod, cylinder liner, oil sump and injector etc including calibration of engine and reassembling of the complete engine as per the manufacturer instruction incl replacing all the gaskets and testing of efficiency of engine on completion of repair work complete all as directed. (worn out parts shall be measured and paid seperately) |
| 118 | Supply only cylinder head by removing worn out valves, valve guide, valve seat etc of existing make and model of 30-125 KVA DG Set complete all as specified and directed. |
| 119 | Taking out crank shaft for existing make and model for 30 to 125 KVA DG set of any make as existing carefully, taking to local market for turning, polishing, metal filling if necessary and refixing of the engine including replacement of main bearings and oil seal complete all as directed. |
| 120 | Supply only turbo charger core assembly for 30 to 125 KVA DG set of any make as existing and model complete all as directed. |
| 121 | Supply only coupling flexible for 30 to 125 KVA DG set of any make as existing and model complete all as specified and directed. |
| 122 | Supply only lub oil cooler 30 to 125 KVA DG set of any make as existing complete all as specified and directed. |
| 123 | Supply only alternator/dynamo 12 volt for 30-125 KVA DG Set of existing make and model complete all as specified and directed |
| 124 | Supply only oil seal complete of existing make and model complete all as specified and directed |
| 125 | Supply only Stop Solenoid for 30-125 KVA DG Set of existing make and model complete all as specified and directed |
| 126 | Supply only piston for 30-125 KVA DG Set of existing make and model complete all as specified and directed |
| 127 | Supply only piston rings for 40-160 KVA DG Set of existing make and model complete all as specified and directed |
| 128 | Supply only gasket for 30-125 KVA DG Set of make and model complete all as specified and directed |
| 129 | Supply only liner for 30-125 KVA DG Set of existing make and model complete all as specified and directed |
| 130 | Supply only Sleeves for 30-125 KVA DG Set of existing make and model complete all as specified and directed |
| 131 | Checking of DG Set internel connections like battery connections, solenoid adjusting and PCB contoller etc and tuning of DG Set of capacity 30KVA to 125KVA when and as required basis complete all as directed. |
| 132 | S&F PCB Controller as per existing make and model as per site requirement for 30-125 KVA DG set of including making connections and tuning of DG Set including taking down old unserviceable item complete all as specified and as directed by Engineer-in-charge. |
| 133 | S&F PCB Controller as per existing make and model as per site requirement for 15 KVA DG set of including making connections and tuning of DG Set including taking down old unserviceable item complete all as specified and as directed by Engineer-in-charge. |
| 134 | S&F in repairs fuel hose pipe/lube oil hose pipe of 10 mm to 25 mm dia (60psi) flexible type, heavy duty as per existing length for 30 to 125 KVA DG Set complete all as directed. |
| 135 | S&F in repairs water hose pipe/fuel hose pipe/lube oil hose pipe of 20 mm to 50 mm dia flexible type, heavy duty as per existing length for 30-125 DG Set complete all as directed. |
| 136 | S&F in replacement of water hose pipes set of any sizes/ size flexible/metal type, heavy duty as per existing specification for 30-125 DG Set complete all as directed. |
| 137 | M&L Cotton waste for cleaning of DG sets all as specified and as directed by Engineer-in-charge. |
| 138 | S&F Belt V ribbed type to drive alternator from pulley as per existing maodel and make for 30 to 125KVA DG Set complete all as specified and as directed by Engineer-in-charge. |
| 139 | Taking down old Silencer Exhaust pipe of any dia and length of existing make and model mouted at any height and ceaning with cleaning agents, metal filling as per site requirement for 30 to 125KVA DG sets , refixing the same Silencer Exhaust pipe with necessary new nuts, bolts and washers including making good the disturbed surfaces complete all as specified and as directed by Engineer-in-charge. |
| 140 | S & F PVC Insulated and PVC Round Sheathed 3 core 1.0 sqmm Bright Annealed Bare Copper Conductor Heavy Duty Flexible Cables for Voltage Grade 1100 Volts for connection of lights in all respects complete all as specified and directed by Engr In Charge. |
| 141 | S & F in replacement of mannul change over switch with sheet steel enclosure of cap 250 Amp 4 pole, 415 V, fixing with wall/ panel ect as specified and directed by Engr In Charge. |
| 142 | S & F in replacement of mannul change over switch with sheet steel enclosure of cap 160 Amp 4 pole, 415 V, fixing with wall/ panel ect as specified and directed by Engr In Charge. |
| 143 | S & F in replacement of mannul change over switch with sheet steel enclosure of cap 315 Amp 4 pole, 415 V, fixing with wall/ panel ect as specified and directed by Engr In Charge. |
| 144 | S & F in replacement of MCCB 4 pole, 50 Hz, 415 Volts, of MCCB 4 pole, 63 Amps, 16 KA, Adjustable Thermal and Fixed Magnetic setting, with separator link . |
| 145 | S & F in replacement of MCCB 4 pole, 50 Hz, 415 Volts, of MCCB 4 pole, 100 Amps, 25 KA, Adjustable Thermal and Fixed Magnetic setting, with separator link . |
| 146 | S & F in replacement of MCCB 4 pole, 50 Hz, 415 Volts, of MCCB 4 pole, 250 Amps, 36 KA, Adjustable Thermal and Fixed Magnetic setting, with separator link . |
| 147 | S & F in replacement Panel LED Phase indicator (R-Y-B) along with connected wiring not less than 1.0 sqmm copper wire all as specified and directed by Engr In Charge. |
| 148 | S & F in replacement of Volt meter/ Ammter digital type of size 96 x 96 mm,1 phase, class -1, 0.5 VA with connected wiring all as specified and directed by Engr In Charge. |
| 149 | Supplying, installing, testing and commissioning pressure boosting pump, 1.0 HP (750 W), single phase, 220 V AC, 50 Hz, rated current 7.5 A, 2700 RPM, with 15 MFD/440 V run capacitor, duty S1, TEFC 2-pole motor, head range 10.5 to 44 m, discharge range 15 to 108 LPM, 25 mm × 25 mm suction/delivery connections, complete with in-built thermal overload protection, pressure boosting arrangement and all necessary accessories including pressure switch, pressure gauge, non-return valve, isolation valves, unions, flexible connections, electrical connections and mounting/fixing accessories, complete all as specified and directed by Engr In Charge. Make-Kirloskar Model No CPBS 73624-V or equivalent. Please Enable Macros to View BoQ information |
| 150 | Supplying, installing, testing and commissioning pressure boosting pump, 1.0 HP (750 W), single phase, 220 V AC, 50 Hz, rated current 7.5 A, 2700 RPM, with 15 MFD/440 V run capacitor, duty S1, TEFC 2-pole motor, head range 10.5 to 44 m, discharge range 15 to 108 LPM, 25 mm × 25 mm suction/delivery connections, complete with in-built thermal overload protection, pressure boosting arrangement and all necessary accessories including pressure switch, pressure gauge, non-return valve, isolation valves, unions, flexible connections, electrical connections and mounting/fixing accessories, complete all as specified and directed by Engr In Charge. Make-Kirloskar Model No CPBS 73624-V or equivalent. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 30, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 19, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysNov 21, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender