Defence Statutory Bodies & Commissions/Committees Closing in 20 days TDR #58294218

Tender For Repair/Replacement Of Oh Lines, Lt Ug Cable Lt Pole, Capacitor Banks, Meters And Other Connected Works At Chinta, Naska, Dugga, Chinchora And Jai Ghatiat Bhalra Mil Station Under Age (I) Bhalra (Nit No. 83 Of 2026-27)

Issued by Statutory Bodies & Commissions/Committees · Nagrota, Jammu and Kashmir
Tender Value
10 Lakhs
Estimated cost
Bid Submission
20 Nov 2026
20 days left
EMD
20000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Nagrota → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair/Replacement Of Oh Lines, Lt Ug Cable Lt Pole, Capacitor Banks, Meters And Other Connected Works At Chinta, Naska, Dugga, Chinchora And Jai Ghatiat Bhalra Mil Station Under Age (I) Bhalra (Nit No. 83 Of 2026-27)

BOQ

Name of Work:- REPAIR/REPLACEMENT OF OH LINES, LT UG CABLE LT POLE, CAPACITOR BANKS, METERS AND OTHER CONNECTED WORKS AT CHINTA, NASKA, DUGGA, CHINCHORA AND JAI GHATIAT BHALRA MIL STATION UNDER AGE (I) BHALRA (NIT No. 83 of 2026-27)
Sl. No. Item Description
1Exc in trenches not exc. 1.5 m wide and not exc. 1.5 in depth and getting out in soft soil for taking up or laying of cable/errecting of pole /stay complete all as specified and directed
2All as per item No 1 above but dept exe. 1.5 mtr but not exe 3 mtr complete all as directed.
3Returning filling in including spreading levelling watering and well ramming in layers not exc. 25 cm thick each complete all as specified and directed
4Removing excavated material to a distance not exc. 50 mtr and depositing where directed at a level not exc. 1.5 mtr above the starting point of any type of soil complete all as specified and directed
5Supply and laying Sand cushioning for the purpose of floors and laying of cables including watering and consiolidation.
6S & L brick covering with width equil to length of brick as the mechanical protction to cable with well burned sub class 'B' laid in trenches flat complete all as specified and directed.
7Laying only old brick over sand cushioning for the cable protection in trenches width of brick prependicular to the length of cable all as specified
8M & L for PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundation filling , basement and mass concrete for poles all as specified directed.
9M & L for PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in foundation filling, basement and mass concrete for poles all as specified directed.
10M & L for PCC 1:2:4 type B-2 (using 40mm graded crushed stone aggregate) as in copping and mass concrete for poles all as specified directed.
11M & L steel tubular swaged pole 9 metre long complete with 6mm cast iron base plate finial taper plug ,bolts, nuts and secrew all as specified type 410, SP-31 (9.0 metres long) includuing painting up to 1.5 M above PCC coping in black and white strips 5 Nos each 30 CM high staring from bottom of pole and two coats of epoxy based paint alumimium grade finish to remaining external surface over one coat of suitable primer complete all as specified and as directed by Engr-in-Charge Note: excavation and foundation concrete will be measuredand piad for sepearetly.
12M & L cross arms, bracings, supports, clamps, back plate fabricated from structural steel sections such as channels, angles, flat i ron including 16mm dia bolts, nuts, washers, welding, bending, cold or hot drilling holes for bolts/insulators in any shape and size as directed and inclusive of one priming coat of red oxide zinc chrome, one under coat and one finishing coat of aluminium paint complete all as directed by the Engr-in-Chage.
13M & L pin type insulator, porcelain, vitreous, white, brown or green including one galvanized mild steel spindle, two galvanised iron washers and one galvanized iron nut, 100mm height, 65mm dia for 1100 volts grade complete all as specified and directed by Engineer-in-Charge.
14M & L shackle type insulator, porcelain, vitreous, white, brown or green including one galvanized mild steel spindle, two galvanised iron washers and one galvanized iron nut, 75mm height, 90mm dia for 1100 volts grade complete all as specified and directed by Engineer-in-Charge.
15M&L for Stay assembly complete with accessories as shown in Electrical Plate No.1 of SSR 2009 Part-I using stay rod of 16 mm dia, stay bow 14 mm dia, 400 mm long, MS Plate of size 300 x 300 mm x 6mm thick, stay GI wire 7/4mm dia (loop type insulator stay clamp, excavation and concrete shall be measured and paid separately) complete all as specified and directed.
16M&L for Aluminium conductor steel reinforced (ACSR) including binding to insulator with suitable size of binding wire and size of conductor Weasel (6/1 x 2.59 mm), Squirrel (6/1 x 2.11mm) or Ferret (6/1 x 3.00 mm) all as specified and as directed.
17M&L for Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size, for LT 20x15 cm size all as specified and directed
18S&F for 1100 Volt grade heavy duty cable PVC Insulated aluminium conductor, served with inner sheathing of PVC tape and over all PVC sheathed in service connection suspended by insulating hanger not more than 1 mtr apart including 4 mm suspension wire, one twin core cable flat or circular 6 sqmm stranded conductor, including taking down old unserviceable service connection complete complete all as specified and directed.
19S&F for 1100 Volt grade heavy duty cable PVC Insulated aluminium conductor, served with inner sheathing of PVC tape and over all PVC sheathed in service connection suspended by insulating hanger not more than 1 mtr apart including 4 mm suspension wire, one twin core cable flat or circular 10 sqmm stranded conductor, including taking down old unserviceable service connection complete complete all as specified and directed.
20S&F for sub main wiring with two single core PVC insulated multistranded un-sheathed FRLS cable of size 2.5 Sqmm with standed copper conductor, drawing into concealed PVC conduit/surface batten (including conduit and accessories) with continuous PVC inculated multistranded unshearhed FRLS cable earth wire of 1.5 Sqmm dia incl taking out unservicable sub main wiring, complete all as specified and directed. Note : Two run of 2.5 Sqmm wire, one run of 1.5 Sqmm wire and one run of PVC conduit shall be considered as one unit length
21M&L for XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 10 Sqmm 2 core, complete all as specified and as directed.
22M&L for XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 10 Sqmm 4 core, complete all as specified and as directed.
23M&L for XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 16 Sqmm 4 core, complete all as specified and as directed.
24M&L for XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 25 Sqmm 4 core, complete all as specified and as directed.
25M&L for XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 35 Sqmm 3.5 core, complete all as specified and as directed.
26M&L for XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 50 Sqmm 3.5 core, complete all as specified and as directed.
27M&L for XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked cross sectional area 70 Sqmm 3.5 core, complete all as specified and as directed.
28M&L MCCB 3 pole , 415 volt, fixed type 63 Amps with breaking capacity 25 KA all as specified and directed by Engr-in-Charge
29M&L MCCB 3 pole , 415 volt, fixed type 100 Amps with breaking capacity 25 KA all as specified and directed by Engr-in-Charge
30M&L MCCB 3 pole , 415 volt, fixed type 125 Amps with breaking capacity 25 KA all as specified and directed by Engr-in-Charge
31M&L MCCB 3 pole , 415 volt, fixed type 160 Amps with breaking capacity 25 KA all as specified and directed by Engr-in-Charge
32M&L MCCB 4 pole , 415 volt, Adjustable type 160 Amps with breaking capacity 36 KA all as specified and directed by Engr-in-Charge
33M&L MCCB 4 pole , 415 volt, Adjustable type 200 Amps with breaking capacity 36 KA all as specified and directed by Engr-in-Charge
34M&L MCCB 4 pole , 415 volt, Adjustable type 250 Amps with breaking capacity 36 KA all as specified and directed by Engr-in-Charge
35Supply and fix ON LOAD change over switch 415 volt in sheet metal enclosures 4 pole of capacity 63 Amps all as specified and directed
36Supply and fix ON LOAD change over switch 415 volt in sheet metal enclosures 4 pole of capacity 160 Amps all as specified and directed
37Supply and fix ON LOAD change over switch 415 volt in sheet metal enclosures 4 pole of capacity 200 Amps all as specified and directed
38Supply and fixing pipe galvanised medium grade 50 mm dia with all fittings etc. laid inany places all as specified and directed
39Supply and fixing pipe galvanised medium grade 80 mm dia with all fittings etc. laid inany places all as specified and directed
40Supply and fixing aluminium cable lugs (Elecrical connector) for tightness to electrical cable with supporting nuts/bolts complete of followings sizes :-
41(a) 25 Sq mm
42(ii) 35 Sq mm
43(iii) 50 Sq mm
44(iv) 70 Sq mm
45M&L testing & Commissioning of LT panel frame CPRI approved, outdoor type,factory made fabircated to CRCA sheet of with min 3.15 mm thickness, double door front/rear opening and locking arrangement, floor mounted on plateform of suitable size, aluminium bus bar chember (enclosed) with two coat of synthetic enamel paint over a coat of red oxide primer mounted on PCC blocks, fixed with grouted bold,nuts and washer and making complete connection in all respects as diected by engr-in-charge comprising of following parts.Incomer MCCB(a) MCCB 400 Amps FP 36 KA - (adjustable thermal and magnetic release) - 01 NoOutgoing MCCB (b) MCCB 200 Amps FP 36 KA - (adjustable thermal and magnetic release) - 02 No(c) MCCB 160 Amps FP 36 KA - (adjustable thermal and magnetic release) - 01 No (e) MCCB 100 Amps FP 16 KA - (adjustable thermal and magnetic release) - 01 No(f) Aluminium bus bar chamber (4 Strips) 3 phase 415 volts 400 Amps all as required (g) Indication lamps for R, Y, B - 1 Nos (h) Digital voltmeter 0-500 volts with selector switch - 01 Set
46(j) Digital ammeter with CT's of suitable ratio & selector switch 0-440 A cap- 01 Set (k) Panel Wiring with suitable size PVC insulated PVC sheathed 1100 volts grade with copper conductor multi-stranded cable with lugs on both ends of cable.(l) Front operated on load change over switch 400 amps.-01 No(m) Lock pedestal - 01 NoMake of Panel : DV Electromatics Private Limited / Simon Fabricators / Electricfield Co / Adhunik Switchgear / Universal Switchgear/ Power ControlMake of MCCB/Change Over : L&T / Legrand / Schneider / Havells/C & S Make of Voltmeter / Ammeter / Multifunction Meter : SECURE / L&T (RISHAB) / C&S ELECTRIC / MECO
47Supply and fix heat shrinkable straight through joint suitable for 1100 V XLPE/ PVC cable of size 70 - 120 sqmm 3.5 core complete incl disconnecting cable and re-connecting complete all as specified and directed by Engineer-in-Charge
48Supply and fix heat shrinkable straight through joint suitable for 1100 V XLPE/ PVC cable of size 25 -50 sqmm 3.5/4 core complete incl disconnecting cable and re-connecting complete all as specified and directed by Engineer-in-Charge
49Taking down LT cable of any size from pole/ panel or any location by opening cable connections and cleaning the cable by cleaning tissue, gel and supply & fix with gland to panel and restore the power supply complete all as specified and directed by Engineer-in-Charge Please Enable Macros to View BoQ information
50Taking down LT cable of any size from pole/ panel or any location by opening cable connections and cleaning the cable by cleaning tissue, gel and supply & fix with gland to panel and restore the power supply complete all as specified and directed by Engineer-in-Charge Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58294218
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 10 Lakhs
LAST DATE 20-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Replacement Of Oh Lines, Lt Ug Cable Lt Pole, Capacitor Banks, Meters And Other Connected Works At Chinta, Naska, Dugga, Chinchora And Jai Ghatiat Bhalra Mil Station Under Age (I) Bhalra (Nit No. 83 Of 2026-27)
Basic Detail
Tender No AGE (I)/Bhalra- /2026-27 (NIT No. 83 of 2026-27)
Bidding Type Tender
Location
City Nagrota
State Jammu and Kashmir
Key Dates
Publish Date 30 Oct 2026
Submission Date 20 Nov 2026
Open Date 23 Nov 2026
Finance
Tender Value 10 Lakhs
Tender Fee 500
EMD 20000
Exemption Not Available
Document List
b9e06df0-a924-463b-a055-37a997eb8ffa.html
BOQ_893471.xls
Tender83.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 30, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 20, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 20 days
Nov 23, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 23 days

Tender Documents

Download All (ZIP) ↓
html

b9e06df0-a924-463b-a055-37a997eb8ffa.html

xls

BOQ_893471.xls

pdf

Tender83.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender