Tender For special Repair To Bldg No P-125,P-126 & P-127 Of 283 Field Wksp Coy At 7011 Eme And Other Sanction Works Under Age B/R-Ii Of Ge (East) Jalandhar Cantt.(Tender Id 2026_Mes_796278_1)
Tender Value
45.62 Lakhs
Estimated cost
Bid Submission
20 Nov 2026
20 days left
EMD
91252
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jalandhar → Punjab
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for special Repair To Bldg No P-125,P-126 & P-127 Of 283 Field Wksp Coy At 7011 Eme And Other Sanction Works Under Age B/R-Ii Of Ge (East) Jalandhar Cantt.(Tender Id 2026_Mes_796278_1)
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling plain or corrugated asbestos cement sheet as in roof coverings complete all as specified and as directed. |
| 2 | Dismantling wrought iron or mild steel work of any description complete all as specified and as directed. |
| 3 | Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water etc and removing surplus spoil out of Defence Land where directed at a level not exc 1.5 m above the starting point complete all as specified and as directed. |
| 4 | Demolition of cement concrete in ground floor and paving/as in sunken portion (below or above ground level) complete all as specified and as directed. . |
| 5 | Demolition of brick work built in cement mortar incl all quions, arches pillars etc but excludding precast concrete articles complete all as specified and as directed. |
| 6 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 7 | S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 8 | S&F Rolled/tubuler section mild steel work roof trusses (framed),trussed, purlins, rafters,crane gantries and heavy brackets framing (beams,tee,angle,channel or flat section) including MS plates, nutt bolts etc complete conforming to Fe 410-W(GdeE -250) quality B complete all as specified and as directed. . |
| 9 | M&L for 15 mm thick cement mortar 1:6 on brick or concrete surface finished even and smooth without using extra cement complete all as specified and as directed. |
| 10 | M&L for preparing newly plastered surfaces of walls by applying two coats of oil bound distemper over a coat of 3mm thick wall care birla while putty complete all as specified and as directed. |
| 11 | M&L for prepration of old surfaces of walls including brooming down or steel wire brushing; scraping down smoke soot, moulds, moss and efflorescent and trading oil and greasy spots etc (Plastered or unplastered surfaces) and applying one coat of oil bound distemper over 3mm thick wall care putty filling uneven surface complete all as specified and as directed. |
| 12 | Complete removal of existing treatment of walls by sander, washing, rubbing down and stopping of distempered and painted surfaces and applying two coat of cement based paint complete all as specified and as directed.. |
| 13 | Preparation of old steel surface of any description over 10 CM width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 14 | Preparation of new steel surface of any description over 10 CM width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed. |
| 15 | Preparation of new wooden surface of any description over 10 CM width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed. |
| 16 | M&L Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. complete all as specified and as directed. |
| 17 | M&L for 20 to 25 mm thick machine in cut kota stone slab flooring over and incl 15mm thick bedding layer CM 1:6 in roughening of old concrete floor surfaces by picking, sweeping clean and washing down with water to remove dust inc brushing neat cement slurry with 3 kg/sqm with pigments to match the shade of slab including cutting, rubbing and mirror/granite finish polishing including taking down old stone slab complete all as directed by Engr-in-Charge. |
| 18 | Ditto all as per item No 17 above but on vertical surfaces such as skirting etc over and including 10mm thick cement plaster finished even and rough to receive tiles in cement mortor (1:4) complete all as specified and as directed. |
| 19 | M&L Brick work with sub class 'B' bricks straight or curved or plan exc 6mm each radius in CM 1:6 complete all as specified and as directed. |
| 20 | M&L for 50mm PCC 1:3:6 type C1 using 20mm graded aggregate as in plinth protection and path finishing, laind in panels the surfaces even and smooth without using extra cement all complete all as specified and as directed. |
| 21 | M&L for mild steel pipe 25 mm dia curtain road with PVC coating fixed in the MS hooks, and finials/side brackets (both side), shade including taking down old as approved by GE complete all as specified and as directed. |
| 22 | Taking down chowkhats or frame with shutter w/o taking off shutter from the frame area not exc 1.5 Sqm each complete all as specified and as directed. |
| 23 | Ditto all as per item ser No 22 above but area exc 1.5 Sqm and not exc 4 Sqm each complete all as specified and as directed. |
| 24 | S&F 35mm thick IInd class hard wood plain framed factory made paneled shutters with (2 panel ) of 9mm BWP commercial ply of 12mm veneered particle bd with commercial veneering on both faces. The size of rail and stile as per IS: 1003 (Part-I) kiln seasoned and chemically treated complete all as specified and as directed. |
| 25 | S&F glazed and skelton shutters factory made 35mm thick open rebated and prepared to receive glass,gauge etc (without sash bars) edging of framing plain, chamfered or rounded with cut and mitred beads for securing glass etc. sizes of members of shutters as specified in SSR Pt-I, Section 8, Clause 8.24(a) complete all as specified and as directed. |
| 26 | M&L Anodized aluminium door shutter having 150mm x 44mm x 2.85mm thick bottom rail, 150 mm x 44mm x 3mm thick middle rail, 100mm x44mm x2.85 mm thick stile and top rail including necessary fitting joinery cleat, glazing packing snap beading 10 mm x 10 mm ,anodixed aluminium handle 200 mm long (02 Nos) , 3 Nos 100 mm size chromium plasted butt hinges, 2 Nos 200mm size Alu tower bolt and Aluminium body hydraulically door closer , designation No-3, universal type, weight between 61 to 80 kg etc inlcuding frame of section 100 mm x 44 mm x2.85 mm and door shutter, bottom portion covered with 9mm thick prelaminated particle board, interior grade, prelaminated on both sides with decorative choice lamination (colour/design approved by Engr-in-Charge) fixed to Aluminium frame work and top portion covered with 5.00 mm thick tinted glass and pattern, one mortion lock (Make: Harrison ) with shutter and fixing including taking down of existing Chowkat with Shutter complete all as specifies and as directed. |
| 27 | S&F 100mm size butt hinges medium weight cold rolled mild steel complete all as specified and as directed. |
| 28 | S&F 150 mm mild steel pressed handles oval type, stove enamelled black complete all as specified and as directed. |
| 29 | S&F 200mm long mild steel tower bolt stove enamelled black with bright bolt complete all as specified and as directed. |
| 30 | S&F 250mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminiumalloy and fixed |
| 31 | S&F Steel Window/Ventilator 1.25 mm thick Box type (Primer coated) ERW hollow P section of size 60 mm x 25 mm single rebated comprises glazed and gauzed skelton shutter EWR sec 50 mm x 20 mm and 1 mm thick and two openable leaf consisting two Nos sash bar of T- section 20 mm x 3 mm complete welded to frame with one vertical mullion of EWRR box type T- section of size 60 mm x 25 mm and 1.25 mm thick including taking out old windows and cuttings holes and making good dismantled portion in PCC (1:2:4) type B-1 four Nos for each window including gauged shutters with sash bars and glasses and wire mesh fixed in all panes and also include the following fittings welded to shutters (a) Hold fasts 150 mm long of 12 mm x 3 mm made to shape-04 nos per window. (b) Handle of Z sec 20 mm x 25 mm, 100 mm long-1 Nos of leaf (c) MS tower bolt 150 mm long 02 Nos per leaf. (d) Z sec 20 mm x 25 mm , 100 long of hollow square 15 mm x 20 mm x 63 mm welded to hinges – 01 Nos per leaf (f) MS pintal hinges of size 75mm x 12 mm -02 Nos per leaf (g) Fabrication and fixing arrangement as per drawing No CEJZ/ TD -06/07 including necessary fittings complete all as specified and as directed. |
| 32 | S&F Mild steel framed work such as guard bars/grills, grating etc with end of bars shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, railings etc and similar works including one shop coat of zinc chromate primer complete all as specified and as directed. |
| 33 | S&F in repair galvanized mild steel wire cloth 0.56 mm nominal dia and average width of aperture 1.18 mm and fixed with tinned tacks complete all as specified and as directed. |
| 34 | S&F 3mm thick sheet glass ordinary quality and glazing with oil putty in square mtr n.exc 0.50 sqm each pane complete all as specified and as directed. . |
| 35 | Taking down carefully existing point wiring of any type/ any size (ie on wooden/ batten, surface conduit, casing capping or concealed conduit) complete for light, fan, socket or power point etc including removing switches, sockets, holders, ceiling rose, pendants, regulators, light fittings, switch board outlets with sheets and other materials from site for refixing of serviceable light and for taking credit of unserviceable light as per Sch of credit and making good disturbed surface of walls,roof, floors etc. with any type of civil wk involved complete all as specified and as directed. |
| 36 | M&L for point wiring for light point with 1.5 Sqmm (nominal area) FRLS PVC insulated unsheathed multi stranded copper conductor of size 1.5 Sqmm cable drawn in and including concealed rigid PVC conduit medium grade not less than 20mm dia with accessories including cutting chases for laying of conduit /fixing of boxes in walls/floor etc including making good to disturbed surfaces as per adjoining specification and terminated in and incl sunken pressed steel boxes(min 50 mm deep and 1.6 mm thick sheet) duly painted with anti corrosive paint over a coat of red oxide primer with plastic laminated bakelite sheet top cover 3mm thick make hylum or equivalent fixed with nickel polished screws with cup washers etc including FRLS PVC insulated unsheathed multi stranded copper conductor 1.5 Sqmm single core as earth continuity conductor (green colour) connected with earth dolly with thimble complete all as specified and as directed by Engineer-in-Charge. |
| 37 | Ditto all as per srl item No. 36.00 above, but for one Fan point controlled by one switch complete all as specified and as directed. |
| 38 | Ditto all as per srl item No. 36.00 above, but for one socket outlet 5 Amps on independent board complete all as specified and as directed. |
| 39 | Ditto all as per srl item No. 36.00 above, but for one socket outlet 5 Amps on the same board controlled complete all as specified and as directed. |
| 40 | Ditto all as per srl item No. 36.00 above, but with 2.5 Sqmm (nominal area) FRLS copper cable for one 3 Pin 15 Amp socket on independent board including one 2.5 Sqmm copper conductor multi stranded green colour PVC insulated unsheathed FRLS cable 1100 volts grade as earth wire connected to common earth and earth dolly with all accessories complete all as directed by Engineer-in-Charge. |
| 41 | S&F in replacement switch piano flush type, 5 Amps, 240 Volt AC single pole, one way complete all as specified and as directed. |
| 42 | S&F in replacement switch piano flush type, 15 Amps, 240 Volt AC single pole, one way complete all as specified and as directed. |
| 43 | S&F in replacement socket out let 5 Amp, 5 pin flush type complete all as specified and as directed. |
| 44 | M&L in replacement Socket outlet multi purpose 2 in 1, 5/6 pin, 5 & 15 Amps, flush type complete all as specified and as directed. |
| 45 | S&F five step fan regulator, electronic type, single phase, including connection complete all as specified and as directed. |
| 46 | S&F in repair for ceiling rose surface type bakelite 65 x 50mm, three terminal complete all as specified and as directed. |
| 47 | S&F LED tube light fitting polycarbonate housing 1 x 20 Watt, appx 4 feet long, with decorative box linear, housing environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to tube fitting, complete fitting with all accessories complete all as as directed by Engineer-in-Charge |
| 48 | S&F in repair for batten holder insulated body with matching colour back plate all as specified and as directed. |
| 49 | S&F LED lamp 12 watt B22 W complete all as directed by Engineer-in-Charge |
| 50 | Taking down and refixing carefully ceiling fan of any sweep, any size/make painting of fans complete (as per previous colour),with synthetic enamel paint by spraying including filling cavaties with filler one coat after cleaning all dust etc. including replacement of flexible wire,rubber reel ,nut,bolts,split pin all as specified and as directed. |
| 51 | M&L for Hanging only/ fixing only ceiling fan 1200mm/1400mm sweep after repair & maintenance upto any height upto 5 Mtr complete incl making electric connections, testing complete all as specified and as directed |
| 52 | S & F LED Flood light fitting 50 watts,made up of pressure die-cast aluminium housing with toughened glass with mandatory secondary optics lenses, with SS screws, IP-66, luminaire efficacy more than 120 Lm/W, CCT 5700K ANSI, CRI>70, THD<10%, PF >0.95, LED source : Hi power LED 3 to 5W High power type .Fitting should be double driver moisture resistant, with internal surge protection 4KV having under voltage, over voltage, phase to phase protection and short circuit protection and auto recovery mode, operating range 150 V to 270 V AC at 50Hz, Auto Cut off >300 V and separte Surge protection device 10 KV complete having fixing bracket clamp complete all as specified and as directed by Engr-in-charge |
| 53 | M&L in replacement of sub main wiring with two run of single core FRLS PVC insulated unsheathed multistranded copper conductor cable of 4 Sqmm drawn through in and including PVC rigid non metallic concealed conduit (medium grade) with all fittings including earth continuity FRLS PVC insulated unsheathed multistranded copper conductor cable 4.0 Sqmm complete with any type of civil work involved to make good disturbed surfaces all as specified.Note : Two run of 4 sqmm wire and one run of 4 sqmm wire as earth wire including PVC concealed conduit shall be measured as one unit |
| 54 | S&F energy efficient LED security light fitting of 25W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street luminaire, with driver, including electric connection with using 3 core flexible copper conductor cable 1.5Sqmm from ceiling rose to light fitting, fixing the light fitting with new bracket made out of GI tubing light grade 25mm dia, 1.2 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron size 25x3 mm with suitable nuts and bolts for fixing of bracket including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete fitting with all accessories and following specifications, complete all as specified and as directed. by Engineer-in-Charge. |
| 55 | S&F (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 200 Amp rated bus bar) SPN, 12 Way 240V, suitable for mounting MCB/Isolator etc, conforming to IS-13032, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-43 protection class, and including making good disturbed surfaces of walls as necessaty complete all as specified and as directed. by Engineer-in-charge.Note :- MCB/Isolator etc shall be measured and paid separately under appropriate item of BOQ. |
| 56 | S&F (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 200 Amp rated bus bar) SPN, 8 Way 240V, suitable for mounting MCB/Isolator etc, conforming to IS-13032, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-43 protection class, and including making good disturbed surfaces of walls as necessaty complete all as specified and as directed. by Engineer-in-charge.Note :- MCB/Isolator etc shall be measured and paid separately under appropriate item of BOQ. |
| 57 | S&F (concealed flush to wall) factory made VTPN (Vertical type), 4 Way 415V, as per IEC 61439-3, DB (made out of CRCA sheet not less than 1.2mm thick, with copper bus bar rating of suitable capacity, with two neutral bar, 2 earth bar and cable tie for cable management, suitable for MCCB 4 pole upto 125Amp, as incomer and suitable for mounting MCBs as outgoing, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-54 protection class, and including making good disturbed surfaces of walls as necessaty complete all as specified and as directed. by Engineer-in-charge.Note :- MCBs for outgoing shall be measured and paid separately under appropriate item of BOQ directed. |
| 58 | S&F in repair MCCBs 125 Amp 4 pole 415 V , adjustable thermal and fixed magnetic settings (0.8 to 1.0) to Ics=100% Icu short circuit setting fixed breaking capacity 25 KA with phase barriers/ separator/spacer/copper spreader link and required nut bolts complete all as specified and as directed. |
| 59 | S&F in repair MCCBs 63 Amp 4 pole 415 V , adjustable thermal and fixed magnetic settings (0.8 to 1.0) to Ics=100% Icu short circuit setting fixed breaking capacity 25 KA with phase barriers/ separator/spacer/copper spreader link and required nut bolts complete all as specified and as directed. |
| 60 | S&F MCB SP 6 to 32 Amps 240 V, 10 KA, B curve as per complete all as specified and as directed. by Engr-in-charge. |
| 61 | S&F MCB SP 40 Amps 240 V, 10 KA, B curve as per complete all as specified and as directed. by Engr-in-charge. |
| 62 | S&F MCB SPN 63 Amps 240 V, 10 KA, B curve as per complete all as specified and as directed. by Engr-in-charge. |
| 63 | Supply, fixing and testing of XLPE insulated in replacement , PVC sheathed galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 35 sqmm 3.5 core complete laid in trenches passing through pipes/culverts/ under roades/ alon wall all as specified and as directed. by Engineer-in-charge. |
| 64 | Supply, fixing and testing of XLPE insulated,in replacement PVC sheathed galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 sqmm 3.5 core complete laid in trenches passing through pipes/culverts/ under roades/ alon wall all as specified and as directed. by Engineer-in-charge. |
| 65 | M&L for Excavation in trenches not exceeding 1.5m in wide and not exceeding 1.5 m in depth for laying of pipe etc and getting out in soft soil, complete all as specified and as directed. |
| 66 | M & L for returning, filling in including spreading leveling watering and well ramming in layers not exc. 25 cm thick complete all as specified and as directed.(Surplus soil if any shall not be removed but left over the trench) |
| 67 | M & L for removing surplus soil to a distance not exc. 50 M and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and as directed. |
| 68 | M & L for sand cushioning with clean dry sand to cables with layer of sand 8 cm before laying of cable and 15 cm thick after laying of cable complete all as specified. |
| 69 | M & L for providing PCC cable cover class LV type-I of size 250x150x40mm laid in perpendicular to the cable abutting each other all as specified and as directed. at site. |
| 70 | S&F in replacement of galvanised pipe light grade of dia 40 mm bore for passing of cable fixed to poles/walls/laid under floor complete with and including fittings as required compete all as specified and as directed. by Engr-in-charge. |
| 71 | Cutting of existing PCC surface any type for laying cables/pipes of size 150mm width and upto 150mm depth complete all as specified. |
| 72 | S&F in replacement of galvanised pipe light grade of dia 50 mm bore for passing of cable fixed to poles/walls/laid under floor complete with and including fittings as required compete all as specified and as directed. by Engr-in-charge. |
| 73 | Taking down and refixing carefully Geyser of , any size/make/capacity. including PVC connection and electric connection complete all as specified and as directed. |
| 74 | M&L for Earthing complete in replacement with galvanised steel earth plate electrode 60cmx60cmx6.0mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level with the top edge of electrode not less than 1.5 metres below normal ground level connected to galvanised earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron and incl GI lead protection pipe of GI light grade 15mm dia upto 7.5 mtrs and watering pipe 20mm bore of GI medium grade with funnel and wiremesh, earth plate covered on all sides with min 150mm thick alternate layers of charcoal, salt all as shown in electrical plate No 3 of SSR Part-I 2020 connected to earthing point with PCC chamber and RCC cover in 1:2:4 complete with any type of earth work involved.all as specified and as directed. and testing on completion. Note:- PCC Chamber shall be constructed at least 0.50 mtr away from on the earth pit electrode and pipe for watering shall be provided in slanting manner.Note:Earth plate weight will be approved by Engr in charge before execution of earth work. |
| 75 | Excavating in post holes (or similar holes) each n. exc 0.5 cum getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n. exc 50m and making good surface in hard dense soil complete all as specified and as directed. |
| 76 | Excavation in trenches n.exc 1.5m wide n.exc 1.5m deep for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n.exc 10 Sqm on plan and n.exc 1.5m depth and getting out in hard dense soil complete all as specified and as directed. |
| 77 | M&L for providing cement concrete type C-2, 1:3:6 (using 40mm graded crushed stone aggregate) as in foundation, bed blocks,filling and mass concrete complete all as specified and as directed. |
| 78 | M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and as directed. |
| 79 | M&L for Brickwork with Modular bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 in narrow widths including Cutting out bricks/stone, forming toothing for, and bonding new into old brickwork /stone masonry complete all as specified and as directed. |
| 80 | M&L rendering 15mm thick in CM (1:4) on fair face of brick/concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed. |
| 81 | S & F mild steel work as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 290 Gde E-165 |
| 82 | \\"Supply only\\" chain link fencing, MS galvanised of any size and type complete all as specified and as directed by Engr in Charge. |
| 83 | \\"Fixing only\\" chain lnk fencing including line wires, any mesh, size, any type of standards, rails, straining bolts, etc including provision of binding wire complete all as specified and as directed Note : chain link fencing shall be measured and paid separately as \\" supply only\\" |
| 84 | S&F fixed 5 to 10 mm dia Mild steel screws bolts(Machine made)with hexagonal or square heads at one end and screwed both ends ,each screwed end to be fitted with washers and one hexagonal or squre nut, lentg of bolt exc 5cm and n.exc 10cm long. With washers. |
| 85 | S&F Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 30, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 20, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysNov 23, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 23 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender