Tender For Repair To Water Proofing Treatment, Leakage-Seepage, Crumple Joints At Chnc And Other Areas And Certain Repair/ Maintenance Of Internal Wiring, Light Fixtures, Switch Socket Combinations Etc For Other Than Hosp Bldgs. And E/M Installations

Issued by Statutory Bodies & Commissions/Committees · Reasi, Jammu and Kashmir
Tender Value
49.99 Lakhs
Estimated cost
Bid Submission
20 Nov 2026
20 days left
EMD
1 Lakhs
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Reasi → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair To Water Proofing Treatment, Leakage-Seepage, Crumple Joints At Chnc And Other Areas And Certain Repair/ Maintenance Of Internal Wiring, Light Fixtures, Switch Socket Combinations Etc For Other Than Hosp Bldgs. And E/M Installations At Chnc And Other Areas Under Ge (U) Udh Ur

BOQ

Name of Work:- Repair to water proofing treatment, leakage-seepage, crumple joints at CHNC and other areas and Certain repair/ maint of internal wiring, light fixtures, switch socket combinations etc for other than hosp bldgs. and E/M installations at CHNC and other areas under GE (U) Udh ur
Sl. No. Item Description
1Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GE Utilities Udhampur Name of Work: Repair to water proofing treatment, leakage-seepage, crumple joints at CHNC and other areas and Certain repair/ maint of internal wiring, light fixtures, switch socket combinations etc for other than hosp bldgs. and E/M installations at CHNC and other areas under GE (U) Udhampur Contract No: GE/U-128/2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Ser.No. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT TOTAL AMOUNT In Words
2Taking down carefully alu./copper point wiring ,light fan socket, or power complete with fittings such as switches ceiling rose;holders; regulators, socket etc removing material to store for keeping in safe custody for reuse or disposal by credit and marking good to disturbed surfaces of walls floors etc and complete all as specified and directed by Engineer-in-charge.
3M & L for concealed point wiring with FRLS grade PVC insulated unsheathed multistranded copper conductor cables of 1.5 sqmm size alongwith one earth continuity conductor with PVC insulated unsheathed multistranded copper conductor cable of 1.5 sqmm size through and including PVC concealed conduit for fixing of modular switches, sockets,light, fan regulators etc for the followingcomplete all as specified and directed by Engineer-in-charge.
4All per item No-02 but for one light point controlled by two nos modular two way switch with cable 1.5 sqmm PVC insulated unsheathed multistranded copper condutor cable complete all as directed by Engr-in -Charge.
5All per item No-02 here-in-before but for one 3/5 pin 5 Amp modular socket point contrlled by one sitch on Indenpendent board complete all as directed by Engr-in -Charge.
6All per item No-02 here-in-before but for one 3/5 pin 5 Amp modular socket point contrlled by one sitch on same board complete all as directed by Engr-in -Charge.
7All per item No-02 here-in before but for 5/6 pin 15 Amp modular socket outlet on independent board with PVC insulated unsheathed FRLS cable 2.5 sqmm multistranded copper conductor , along with PVC insulated unsheathed FRLS cable 2.5 sqmm multistranded copper conductor earth wire connectecd to common earth wire and earth dolly complete all as directed by Engr-in -Charge.
8M & L for modular white cover plate with frame 8 module complete all as directed by Engr-in -Charge.
9M & L for modular white cover plate with frame 6 module complete all a specified and directed by Engr-in -Charge.
10M & L for modular white cover plate with frame 4 module complete all a specified and directed by Engr-in -Charge.
11M & L for modular white cover plate with frame 3 module complete all a specified and directed by Engr-in -Charge.
12M & L for modular white cover plate with frame 2 module complete all a specified and directed by Engr-in -Charge.
13M & L for modular white cover plate with frame 1 module complete all a specified and directed by Engr-in -Charge.
14S&F Modular switch one way 6 A,1 module 240 Volt, ISI marked complete all a specified and directed by Engr-in -Charge.
15S&F Modular Bell push,one way 6 A, 1 module, 240 Volt ,ISI marked complete all a specified and directed by Engr-in -Charge.
16S&F modular Switch single pole 16A one way, 1 module 240 Volt, ISI marked complete all a specified and directed by Engr-in -Charge.
17S&F modular Switch 10 amp, 2 way, 1 module, 240 Volt ,ISI marked complete all a specified and directed by Engr-in -Charge.
18S&F modular socket 3 pin 6Amp 2 module ISI marked complete all a specified and directed by Engr-in -Charge.
19S&F modular socket out let 6 /16 Amps 3 pin, 2 module complete all a specified and directed by Engr-in -Charge.
20S&F Fan step regulator, 120W - 2 module complete all a specified and directed by Engr-in -Charge.
21S&F Call Bell, AC, 230 volts, single pole, ISI marked complete all a specified and directed by Engr-in -Charge.
22S&F Ceiling rose, 3 phase/PVC/polycarbonate, isolated body, ISI marked complete all a specified and directed by Engr-in -Charge.
23S&F in replacement TV Co- axial socket complete all as specified and directed by Engineer-in-Charge.
24S&F in replacement LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete making all connection using 1.5 sqmm copper conductor multistrandard PVC insulated 2 core flexible cable with flexible PVC pipe from ceiling rose to fittings complete all a specified and directed by Engr-in -Charge.
25Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 9/10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete making all connection using 1.5 sqmm copper conductor multistrandard PVC insulated 2 core flexible cable with flexible PVC pipe from ceiling rose to fittings complete all a specified and directed by Engr-in -Charge.
26S&F in replacement of sub main wiring with copper conductor cable (2 runs of cable) multistaranded 6.0Sqmm PVC ISI marked with all insulated unsheathed in and including PVC concealed conduit 25mm dia medium grade fittings including 6.0 Sqmm copper conductor cable PVC insulated unsheathed multithreaded using as continues earth wire connected to common earth and earth dolly complete all a specified and directed by Engr-in -Charge.
27S&F Sheet metal enclosure factory made for DBs single pole and neutral double door 240 volts 12 way with 200 Amps rated bus bar fixed on walls, including dressing and connecting both incoming and outgoing cable termination with proper taping, lagging testing, and commissioning and making good of wall surfaces complete all a specified and directed by Engr-in -Charge.
28S&F MCB single pole and neutral, 'C' curve 240 Volts , 50 Hz 10 Ka, 40 Amps, complete all a specified and directed by Engr-in -Charge.
29S&F MCB single pole 240 Volts , 6 to 20 Amps 'B' curve complete all a specified and directed by Engr-in -Charge. Make : Havells/Legrand/Philips
30S&F RCBO four pole , 50 Hz ,30mA, 63 Amps, complete all a specified and directed by Engr-in -Charge.
31S&F MCB TPN , 50 Hz ,415 V, 63 Amps, complete all a specified and directed by Engr-in -Charge
32S&F condenser/capacitor suitable for 230 volts singls phase celling fan 1200mm/1400 sweep of approved make and quilty of capacity 2.5 MFD, complete all as specified and as directed by Engineer-in-Charge.
33Supply, installation, testing and commissioning of water Storage Type Electric Water Heater (Geyser) 05 Litre capacity, complete with all accessories as specified below:Capacity: 05 LitresType: Instantaneous / Mini storage typePower Rating: 2 kW (approx.) Input Supply: 230 Volts AC, 50 Hz, Single PhaseHeating Element: Heavy duty copper / glass coated heating elementTank: Pressure type inner tank with anti-corrosion coatingBody: ABS / Rust proof outer body Working Pressure: min 6–8 barSafety Features:Inbuilt thermostat,Thermal cut-out,Multi-function safety valve,Pressure relief valve,IP Protection: IPX4 or better,Mounting: Wall mounted type,Warranty: Minimum 2 years on product and on tank
34Note(i):- Quoted rate Includes providing and fixing necessary inlet and outlet connections PVC Pipes , CP brass nipples, connection to existing water supply line, connection to electrical point, testing and commissioning complete all as specified and directed by Engr-In-Charge.Note (ii) : Old unserviceable Exhaust fan deposited to E/M store for taken on Charge.
35S&F radiant 07W LED Step light environmental friendly, new generation, energy saving, decorative rectangularshaped IP66 LED step light for wall recessed application complete all a specified and directed by Engr-in -Charge. Make : Havells Model No ADIANTFTR07WLED830PSYMTOPC
36Supply and fix in replacemet wall mounted fan 230 volts single phase oscillating 400 mm sweeep, metal body with three speed controller switch all as complete all a specified and directed by Engr-in -Charge.
37Supply and fix in replacemet exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete all as specified and directed by Engr-in -Charge.Note : Old unserviceable Exhaust fan deposited to E/M store for taken on Charge.
38Supply and fix LED Flaxi strip Neon AC LED warm white Colour Strip Light with PVC outer cover ,IP 65 input voltage 220-240 VAC input frequency 50 Hzs power factor ss protection -IP -65 working temp range -20 degree celcius to + 45 degree celcius working humidity range 10-90 RH and complete all as specified & directed by Engr-in-Charge.
39Dismantling Wall Partition and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, any position, includingcover fillets, all as specified and directed by Engr-in-charge.
40Taking down cement plaster including tiles of any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed by Engr-in-charge.
41Dismantling brick tiles or terracing tiles, single layer of roofs including demolition and removing of mud in roofs any thickness including plastering and leeping (whether full thickness removed or part thereof) and demolition material disposed out from MoD land and including roughening surfaces of old concrete by picking, sweeping/brushing clean and washing down with water to remove dust and apply neat cement slurry with 3.0 kg of cement per sq. metre, complete all as specified and directed by Engr-in-Charge.
42M & L for cleaning of all loose dirt and dust from roof surfaces also joints to be cleaned by grinder & brush and applying roof treatment as under:(a) Applying a coat of fibre reinforced PU primer confirming to ASTM D412 @ 3:1 water dilution on prepared surfaces & laying of glass fibermesh 45 gsm over tacky surface and allow it to dry.(b) Supply and Applying 2 coats of Hybrid PU based elastomeric single component coating over primer surface @ 10 kg/10.76 Sqm total consumption having below properties:-1. Elongation - 500% to 600%2. Solid contents - 80%3. Tensile Strength - 1.6 N/mm²4. Adhesion to concrete - 2.2 N/mm²5. Initial hardness shore strength - 60 Min6. Tear Strength - 44 N/mm²7. Total thickness of layer shall be : 1.2 - 1.5 mmNote: The net area of water proofing treatment shall be measured without any extra allowance for laps & portion inserted in groove which shall be deemed included in the quoted rates.The work for roof treatment shall include the following and the rates quoted by the bidder shall include the same:(aa) The work pertaining to roof treatment shall be executed by the contractor from authorised applicator through manufacturer of the materials like PU primer etc after approval by the GE.
43M & L for cleaning of all loose dirt and dust from roof surfaces and applying roof treatment as under:(a) 10 mm thick plastering using polymer modifued ready mixed cement plaster, readiplast pro with WPC @ 2% by weight of cement.(b) Applying a coat of bituminous primer @ 0.50 Kgs/Sqm on prepared surfaces and allow to dry.(c) Applying a coat of hot blown bitumen 85/25 grade @ 1.20 Kgs/Sqm over primer.(d) Supply and laying of 3 mm thick (Minimum) polymeric water proofing membrane weighing not less than 3 Kgs/Sqm.(e) Applying a tack coat of hot blown bitumen grade 85/25 @ 1.20 Kgs/Sqm.(f) Blinding with dry coarse sand @ 0.50 to 1.0 Kg/Sqm dusted over bitumen.(g) Supply and laying factory made PCC tiles 40 mm thick over and including 15 mm thick screed bed in CM (1:4) and jointing and pointing in CM (1:4) by mixing linseed oil @ 5% weight of cement.Note: The net area of water proofing treatment shall be measured without any extra allowance for laps & portion inserted in groove which shall be deemed included in the quoted rates.Note: Pond test will be carried out after roof treatment.
44Rendering 15 mm thick polymer modified ready mixed cement based plaster (in two layers – first 10 mm thick and then 5 mm thick) finished even and smooth on faces of brick work/stone work/concrete surfaces without using extra cement, complete all as specified and directed.Plaster shall be carried out up to maximum 21 metres height in patches Contractor shall have no claim for height and scaffolding whatsoever is required to complete all as specified and directed by Engr-in-charge.
45Rendering of 10 mm thick polymer modified ready mixed cement based plaster finished even and smooth on faces of bricks work/stone work/concrete surface finished the surface even and smooth(without using extra cement) complete all as sspecified and directed.Notes:-Plaster shall be carried out upto maximum 21 metres height in patches and contractor shall have no claim for height and scaffolding what so ever is required to complete the work, complete all as specified and directed by Engr-in-charge.
46M&L two coats of exterior-grade (100% acrylic) paint over one coat of primer, including preparation of newly plastered wall surfaces, scaffolding and safety arrangements up to 20 m height, complete all as specified and directed by Engr-in-charge.
47M&L for preparation of newly plastered wall surfaces including applying one coat of wall putty to achieve smooth finish, followed by two coats of oil‑bound distemper of approved shade/tint, complete all as specified and directed by Engineer‑in‑charge.
48Supply and application of sealant Ottoseal S 70 Premium silicone at junctions of windows, skylight roof, wall-floor tile joints, expansion joints, crumple joints, etc., or approved equivalent, complete all as specified and directed by Engr-in-charge.
49S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-Charge.
50S&F Powder coated aluminium (minimum thickness of powder coating 50 micron)work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete asper architectural drawings and the directions of Engineer-in-Charge.
51S&F aluminum handles cast type, anodised, 150 mm size complete all as specified and directed by Engineer-in Charge.
52S&F Mild Steel butt Hinges medium weight 100 mm long match with shutters fixed with screw complete all as specified and directed by Engr-in-charge.
53S & F aluminium anodised, barrel tower bolt 150mm long match with shutters fixed with screws, complete all as specified and as directed by Engr-in-charge.
545mm thick sheet glass, ordinary quality and glazing with rubber neoprene packing for aluminium doors/windows/Partition in square/rectangular exc 0.5 sq. m in each pane, complete all as specified and directed by Engr-in-charge.
55S&F 5mm thick plain colour PVC sheet in strips & channel feathered at the edges for fixing as in aluminium window /partitionn fixing with rubber neoprene packing and powder coaded aluminium beading ,complete all as specified and as directed by Engr-in-charge.
56Demolition of brickwork or stone/boulder masonry built in cement mortar, including quoins, arches and pillars but excluding ashlar facing, dressed stonework and precast concrete articles, complete all as specified and directed by Engr-in-charge.
57Brickwork with sub-class 'B' bricks, straight or curved on plan exceeding 6 m mean radius, built in CM 1:6, complete as specified and directed by the Engineer-in-Charge.
58Dismantling floor, hearth or wall tiling, including cement-mortar bedding (but not backing coat), and removing rubbish off the premises, complete all as specified and directed by Engr-in-charge.
59S&F mosaic tiles of 300 x 300 mm, colour as approved, set, jointed and pointed in appropriate epoxy or cement tile adhesive on vertical or horizontal surfaces, including 15 mm thick backing coat/screed bed in CM 1:6, complete all as specified and directed by Engr-in-charge.
60S&F Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, including 20 mm cement-sand screed bed in CM 1:4, complete as directed and specified by Engr-in-charge
61S&F glazed ceramic-coloured tiles of size 300 x 450 x 7 mm thick, set and jointed in neat cement slurry and pointed in coloured cement to match, including 10 mm thick backing coat in CM 1:4, complete all as specified and directed by Engr-in-charge.
62S&F in repairs 110 mm bore dia PVC (SWR) pipes, single socketed in any length with rubber-ring joints, including clamps at every 900 mm interval fixed to walls complete all as specified and directed by Engr-in-charge.
63Ditto—all as per item No. _60_ herein-before, but bore of pipe 150 mm complete all as specified and directed by Engr-in-charge.
64S&F in repairs PVC (SWR) bends any radius, bore of pipe 110mm, complete all as specified and directed by Engr-in-charge.
65Description all as per Ser item No 26.00, here-in-before, but bore of pipe 150mm, complete all as specified and directed by Engr-in-charge.
66Supply and fixing in repairs, heavy-duty interior decorative wall panels from the \\"Flawless Flutes\\" collection (Series 17000 or equivalent), manufactured utilizing high-density, eco-friendly Polystyrene (PS) Louvers composite material. The panels shall possess specified dimensions of 9.5 feet (2900mm) in length and 12 inches (300mm) in width with an integrated tongue-and-groove interlocking profiling edge for entirely seamless joints. The material must be inherently water-resistant, termite-proof, stain-resistant, lightweight, and warp-free. Panels are to be fixed to clean, level brickwork surfaces, MDF/plywood framework backing, or metallic battens spaced uniformly at 18 to 24-inch intervals as instructed. Installation must utilize premium-grade construction polymers/adhesives on the rear substrate, augmented with concealed headless brad nails or clips driven through the tongue structure to guarantee a completely invisible, flush surface attachment. The scope covers precise plumb alignment, corner profiling, clean linear cutting with fine-toothed equipment, layout management, joint adjustments, scaffolding, and site cleanup, completed to the absolute satisfaction of the Engineer-in-Charge.
67Taking down chowkats or frames including shutters (without taking off shutters from the frames) exceeding 1.50 Sqm but not exceeding 4 Sqm each, and removing from site, complete all as specified and directed by Engr-in-charge.
68S&F factory made single extruded designer WPC (Wood Polymer Composite) solid door/ window/Ceosetory windows & other Frames/Chowkhat of size 65x 125 mm comprisingof virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives(maximum toxicity index of 12 for 100 gms)fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold st/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e.depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made complete in all respects as specified and directed by the Engineer-in-Charge.
69Providing and fixing factory made single extruded designer WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 35mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade),CNC routed grooves, or pre-moulded panels, calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer In- Charge. (Note: stainless steel butt hinges shall be paid separately)
70S&F sliding door bolt superior grade 300mm long heavy-duty Stainless Steel (SS 316), 300 mm long stove enameled black with bright bolt not less 12 mm dia bolt with and including a inimum of 6 bolts and nuts, four on bolt plate and two on staple plate, complete all as specified and directed.
71S&F steel window (box type) factory made with sidehung shutter including pintol hinges, steel handles, steel peg stay and all locking arrangement complete with glazing barsdovetailed or welded including one shop coat of red oxide primer, complete all as specified and directed by Engr-in charge. Note : i) The window shall be fabricated as per Drg No CEUZ/TD/1269/2008 Sheet 1/3 to 3/3 . ii) MS fillets, glazing wire gauge shall be measured and paid seprately.
72Description all as per Ser item No 24 here-in-before but without glazing bar, complete all as specified and directed by Engr-in-charge. Note : i) The window shall be fabricated as per Drg No Z/TD/1269/2008 sheet 1/3 to 3/3. ii) MS fillets, glazing, wire gauge shall be measured and paid seprately.
73Preparation of new steel surfaces of any description not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, complete all as specified and directed.
74Scientific cleaning & Sterilization of PVC Water Storage Tanks of capacity upto 2000 litres: The job involves 6 stage Scientific Cleaning and Sterilization Process Consisting of Mechanical Dewatering, Hi-Pressure Cleaning, Sludge Removal, Vacuum Cleaning, Antibacterial spray and finally killing of suspended & floating bacteria by Ultra violet Radiation as detailed below:-1. Dewatering of Tanks:- The water from the storage tanks will be pumped out of tanks through Mechanical Dewatering Pumps of suitable capacity.2. High Pressure Interior Cleaning:- The interiors of the water storage tanks will be cleaned with high pressure jet which dislodges the layers of dirt and other suspended foreign bodies which may be sticking on the walls. This process will remove the layer of calcinations of dirt if any so as to make the interior free of any germs and bacteria.3. Sludge Removal:- The Dirty water and Sludge collected in the previous operation will be removed using industrial Sludge pumps and disposed off properly , away to a safer place so as not to contaminate the water. The Floor of the water Storage tanks should be again cleaned thoroughly using high pressure jet stream so as to remove all the remaining dirt which may be sticking on the floor even after the removal of sludge slurry.4. Drying of Tanks:- The Water storage Tanks will then be dried using Industrial Vacuum Cleaners of Suitable Capacity.5. Antibacterial Spraying:- The inside walls, ceiling and floor of the Water Storage Tanks will then be given the Antibacterial Treatment which would ensure all interior walls, ceiling and floor surface of the Water Storage Tanks totally Germs free.6. Sterilization using Ultra Violet Radiation:- Finally , UV Radiator will be used to ensure the complete wipe out of any bacterial traces which may still be present even after the completion of above processes by giving Ultra Violet Treatment on all Interior Surfaces.Note : The contractor shall mark the outer tank surface mentioning date of cleaning through acrylic paint.
75S&F of stainless steel wire clothcut for new/old door & window to size, 0.36 mm nominal dia wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvanised wire staple in repairs, complete all as specified and directed by Engr-in-charge.
76Hacking out old broken glasses (any thickness, size, quality or description) from wooden frames or steel frames, glazed with putty or fixed with wooden beads, complete all as specified and directed by Engr-in-charge.
773mm Plain/tinted/frosted glass, selected quality and glazing with rubber neoprene packing for doors/windows in re/rectangular exc 0.5 sq. m in each pane included all connected accessories, complete all as specified and directed by Engr-in-charge.
78S & F 10-12mm thick aqua marin shade toughned glass used in structural glazing in facade fixed with frame necessary assessories clip nails screw etc including sacaffolding and safety arrangement arrangement up to 25 meter height, complete all as specified and directed by Engr-in-charge.Note:- The Glasses shall be fixed upto any required height , and the contractor shall ensure installation without any extra cost also cotractor will be responsible for any damages during the working.
79Supply and fixing in repairs of hospital-grade, high-impact rigid PVC Corner Guards in Ivory White color, having a minimum wing size of 50mm x 50mm and profile thickness of 2.0mm to 3.0mm, featuring a scratch-resistant textured surface with rounded safety edges. The assembly shall include a 100% virgin extruded structural aluminium continuous retainer base alloy conforming to IS 733, securely fastened to the existing masonry or concrete wall surfaces at required levels using counter-sunk screws and heavy-duty nylon wall plugs. The outer fire-retardant, anti-bacterial, and chemical-resistant uPVC cover profile shall be seamlessly snapped over the aluminium retainer track to conceal all fasteners. The work must be completed including all necessary injection-molded ABS top and bottom end caps, joint pieces, alignment checks, site clearing, and labor charges. All materials and execution must strictly adhere to healthcare infection-control protocols, engineering drawings, and instructions of the Engineer-in-Charge, measured in running meters.
80Providing access, safety arrangements, scaffolding/working platforms, ladders, temporary lighting and all incidental arrangements for complete OHT waterproofing/repair works, including dismantling after completion, complete all as specified and directed by Engr-in-charge.
81Emptying, cleaning and de-sludging existing tank; removal of algae, scale, deposits, dirt, loose material and biological growth from internal floor, walls, roof soffit and fittings by scraping, wire brushing and high-pressure water jet; disposal complete all as specified and directed by Engr-in-charge.
82Removing loose/delaminated concrete, old coating, laitance and unsound material from RCC surfaces, including preparation for repair; disposal complete all as specified and directed by Engr-in-charge.
83Cleaning exposed reinforcement by mechanical means and applying approved corrosion-protection/passivation coating compatible with repair mortar; complete all as specified and directed by Engr-in-charge.
84Cutting/chasing non-structural cracks in suitable V/U groove, cleaning and filling with compatible polymer-modified repair material/sealant; finish flush, complete all as specified and directed by Engr-in-charge.
85Treatment of construction/control joints, wall-floor junctions, corners and critical leakage lines using compatible flexible waterproofing mortar and alkali-resistant fibre/fabric reinforcement, complete all as specified and directed by Engr-in-charge.
86Repair of honeycombed/spalled RCC including removal of unsound concrete, cleaning reinforcement, bonding coat and rebuilding with polymer-modified structural repair mortar/non-shrink repair material, finished true to line and level complete all as specified and directed by Engr-in-charge.
87Providing polymer-modified repair/plaster mortar to localised porous/uneven RCC surfaces, including UltraTech compatible SBR/bonding agent, levelling and finishing, complete all as specified and directed by Engr-in-charge.
88Providing localised fairing/levelling of prepared RCC surfaces to receive waterproof coating, including polymer-modified mortar and finishing; complete all as specified and directed by Engr-in-charge.
89Providing and applying UltraTech Seal & Dry Single Component cementitious polymer-modified waterproofing coating to all potable-water contact RCC surfaces, including SSD preparation, mixing, two perpendicular coats, curing, dry sand broadcast where required, and all incidental works. Product shall be suitable for drinking-water storage tanks and used strictly to current manufacturer TDS complete all as specified and directed by Engr-in-charge.
90Additional treatment to internal wall-floor junctions, corners, pipe penetrations and critical leakage points with compatible flexible waterproofing mortar and reinforcing fabric/mesh, integrated with main coating system complete all as specified and directed by Engr-in-charge.
91Providing 150 mm high self-coving at internal wall-floor junction using polymer-modified waterproof repair mortar, rounded/smooth finished and integrated with waterproofing system complete all as specified and directed by Engr-in-charge.
92Providing cementitious protective screed/plaster over horizontal waterproofed floor/roof areas where required, including preparation, slope and finishing; thickness 20 mm average complete all as specified and directed by Engr-in-charge.
93Final potable-water contact surface cleaning, curing and preparation after waterproofing, including removal of loose particles and making surface ready for testing/disinfection complete all as specified and directed by Engr-in-charge.
94External RCC surface preparation by scraping, wire brushing and pressure washing; removal of loose coating, algae, dirt, laitance and unsound material, complete all as specified and directed by Engr-in-charge.
95Filling/chasing/sealing external cracks up to 5 mm with compatible polymer-modified crack repair material, complete all as specified and directed by Engr-in-charge.
96Providing and applying UltraTech Seal & Dry Hi-Flex two-component flexible polymer-modified waterproof coating to external positive-side RCC surfaces in two coats, second coat perpendicular to first, including surface preparation, mixing, curing and all incidental works; application strictly as current manufacturer TDS complete all as specified and directed by Engr-in-charge.
97Providing and applying weather-resistant protective exterior finish over treated external RCC tank surfaces, including compatible primer and two finishing coats, complete all as specified and directed by Engr-in-charge.
98Preparing exposed OHT roof top including cleaning, removal of loose material, crack/joint treatment, local levelling and making surface ready for waterproofing complete all as specified and directed by Engr-in-charge.
99Providing and applying UltraTech Seal & Dry Hi-Flex flexible waterproofing coating to exposed roof top in two coats with perpendicular application, including critical detail treatment, complete all as specified and directed by Engr-in-charge.
100Providing protective screed to roof waterproofing, minimum 20 mm average, laid to slope towards rainwater outlets and finished smooth, complete all as specified and directed by Engr-in-charge.
101NOTE for Item No. 78 to 98:- (a) Treatment of inlet/outlet/overflow/scour/washout pipe penetrations: sealing annulus and flexible waterproofing.(b) Treatment of manhole cover/frame and access opening against rainwater ingress.(c) Special treatment of overflow outlets and surrounding RCC: crack sealing and waterproof coating.(d) Pond/leakage test: staged filling, minimum 4–5 days monitoring, rectification of defects.(e) Final cleaning, washing and disinfection/chlorination; tank ready for potable-water service.(f) Product certificates/TDS, batch records, QA/QC checklists, photographs, test records and warranty documents.
102S&F heavy-duty decorative butt hinges, 125 × 64 mm minimum, fabricated from SS 304 grade stainless steel, minimum 2.5 mm thickness, with approved premium satin-brass / antique-brass / matte-black finish, suitable for decorative WPC door shutters, complete with matching corrosion-resistant screws, including marking, drilling, fixing to shutter and frame, and providing approved reinforcement or suitable screw-fixing arrangement in the WPC frame wherever required, complete all as specified and directed by the Engineer-in-Charge. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58294189
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 49.99 Lakhs
LAST DATE 20-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair To Water Proofing Treatment, Leakage-Seepage, Crumple Joints At Chnc And Other Areas And Certain Repair/ Maintenance Of Internal Wiring, Light Fixtures, Switch Socket Combinations Etc For Other Than Hosp Bldgs. And E/M Installations At Chnc And Other Areas Under Ge (U) Udh Ur
Basic Detail
Tender No GE/U-128/2026-27
Bidding Type Tender
Location
City Reasi
State Jammu and Kashmir
Key Dates
Publish Date 30 Oct 2026
Submission Date 20 Nov 2026
Open Date 23 Nov 2026
Finance
Tender Value 49.99 Lakhs
Tender Fee 500
EMD 1 Lakhs
Exemption Not Available
Document List
39e916d0-94a5-4597-9ad5-60dbb4b81ff3.html
BOQ_893446.xls
TENDER128.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 30, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 20, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 20 days
Nov 23, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 23 days

Tender Documents

Download All (ZIP) ↓
html

39e916d0-94a5-4597-9ad5-60dbb4b81ff3.html

xls

BOQ_893446.xls

pdf

TENDER128.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender