Tender For Repair And Maintenance Of Internal Electrification, Fitting Fixtures And Other Items In Otm & Md Accn Of Od Alipore & Sahapore Area Under Ge (C ) Kolkata.
Tender Value
30 Lakhs
Estimated cost
Bid Submission
21 Nov 2026
21 days left
EMD
60000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kolkata → West Bengal
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair And Maintenance Of Internal Electrification, Fitting Fixtures And Other Items In Otm & Md Accn Of Od Alipore & Sahapore Area Under Ge (C ) Kolkata.
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GE ( C ) KOLKATA NAME OF WORK: REPAIR AND MAINT OF INTERNAL ELECTRIFICATION, FITTING FIXTURES AND OTHER ITEMS IN OTM & MD ACCN OF OD ALIPORE & SAHAPORE AREA UNDER GE (C ) KOLKATA. Contract No: GE (C )/KOL/ OF 2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevant columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # ItemNo. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Conversion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT TOTAL AMOUNT In Words |
| 2 | Taking down point wiring (light, fan, socket and power complete including fixtures and fittings such as switches ceiling roses, pendents , regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody for refixing or for taking credit ( credit for above items should be made as per conditions separately) and making good distrubed surfaces of walls, floors, etc. |
| 3 | M&L for point wiring for one light / ceiling fan/exhaust fan/bell point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (confirming to IS-694, 1990) including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn through and including PVC casing caping of size not less than 20mm width (ISI marked) with all fittings such as tees, bends etc including sunk type GI box, made out of 1.6mm thick sheet covered with 3 mm thick laminated sheet top cover for housing switches, sockets, fan regulators etc complete, all as specified & directed. |
| 4 | All as per item No. 2.00 here in before but for one 5 Amp socket outlet on the same board with other switches. |
| 5 | All as per item No. 2.00 here in before but for one 5 Amp switch socket combination on independent board |
| 6 | All as per item No. 2.00 here in before but for One Light point controlled by two, two way switches. |
| 7 | All as per item No. 2.00 here in before but for 15 Amp socket outlet by using 2.50 Sqmm PVC insulated unsheathed copper conductor cable FRLSH multi stranded on independent board including provn of 2.50 Sqmm unsheathed, multistranded copper conductor cable FRLSH continues as earth wire connected to earth dolly etc complete all as specified and directed |
| 8 | All as per item No. 2.00 here-in-before but using 4 sq mm size stranded copper conductor cable for one AC Starter including 4 sq mm PVC insulated unsheathed stranded copper conductor as earth lead complete all as specified and directed. |
| 9 | M&L for point wiring for one light/fan/bell point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (Confirming to IS-694, 1990) including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn through and including rigid PVC conduit including sunken type GI box made up of 1.6mm thick sheet covered with 3 mm thick laminated sheet top cover for housing switches, sockets, fan regulators etc complete, all as specified & directed. |
| 10 | All as per item No. 8.00 here in before but for one 5 Amp socket outlet on the same board with other switches. |
| 11 | All as per item No. 8.00 here in before but for one 5 Amp switch socket combination on independent board |
| 12 | All as per item No. 8 here in before but for One Light point controlled by two, two way switches. |
| 13 | All as per item No. 8.00 here in before but for 15 Amp socket outlet by using 2.50 Sqmm PVC insulated unsheathed copper conductor cable FRLSH multi stranded on independent board . |
| 14 | All as per item No. 8.00 here-in-before but using 4 sq mm size stranded copper conductor cable for one AC starter. |
| 15 | Supply & Fix switch piano, flush type, single pole, one way, 5/6 Amp, 240 Volts all as specified & directed |
| 16 | Supply & Fix switch piano, flush type, single pole, two way, 5/6 Amp, 240 Volts all as specified & directed |
| 17 | S&F bell push flush type 5 Amps.single pole, one way, 5/6 Amp, 240 Volts all as specified & directed |
| 18 | S&F for switch socket combination 3 pin 5 Amps 240 volts flush type all as specified & directed |
| 19 | S&F socket out let 3 pin 5 Amps flush type 240 volts flush type all as specified & directed |
| 20 | S&F switch socket combination multipurpose 3 pin 15 Amps and one pin 5 Amps controlled by one switch. |
| 21 | M&L for lamp holder insulated body with back plate for batten fittings complete all as directed |
| 22 | S&F Ceiling rose, 3 phase/PVC/polycarbonate, isolated body |
| 23 | S&F call bell, ding dong AC 230 volt single pole (ding dong type). |
| 24 | S&F electronic step type fan regulator for type 230 volt. |
| 25 | S&F in replacement GI rectangular sunken box of size 100mm X 100mm X 50 mm with 3mm thick plastic laminated sheet cover for mounting switches, sockets, fan regulator etc deep sunk in wall including making good disturbed surfaces complete all as specified and directed.Note: The cost of cutting chasing of wall, if required and making good disturbed surface in CM (1:3) and finishing the surface to match with existing surface is deemed to be including in quoted rate. |
| 26 | S&F in replacement GI rectangular sunken box of size 200mm X 250mm X 50 mm with 3mm with 3mm thick plastic laminated sheet cover for mounting, switches, sockets, fan regulator etc deep sunk in wall including making good disturbed surfaces complete all as specified and directed.Note: The cost of cutting chasing of wall, if required and making good disturbed surface in CM (1:3) and finishig the surface to match with existing surfaceis deemed to be included in quoted rate. |
| 27 | S&F, in repairs, switch piano flush single pole one way 5 amps complete all as specified and directed. |
| 28 | Supply & Fix, in repairs, switch piano, flush type, single pole, two way, 5/6 Amp, 240 Volts complete all as specified & directed. |
| 29 | S&F in repairs switch socket combination 3 pin 5 Amps 240 volts flush type complete all as specified & directed. |
| 30 | S&F in repairs socket out let 3 pin 5 Amps flush type complete all as specified & directed. |
| 31 | S&F in repairs switch socket outlet multipurpose 3 pin 15 Amps complete all as specified & directed. |
| 32 | S&F in repairs lamp holder insulated body with back plate for batten fittings complete all as directed |
| 33 | S&F in repairs ceiling rose surface bakelite 65x50mm single phase complete all as directed. |
| 34 | S&F in repairs call bell, ding dong AC 230 volt single pole (ding dong type) complete all as directed. |
| 35 | S&F in repairs electronic step type fan regulator paino type/socket type 240 volt complete all as directed. |
| 36 | M&L for point wiring for one light/ bell/ fan controlled by one number one way switch with 1100V grade FRLSH PVC insulated unsheathed multistranded copper conductor cable conforming to IS : 694 of size 1.5 Sqmm two runs single core for phase and neutral drawn through in and including rigid PVC concealed conduit of suitable size (minimum 20mm dia medium grade ISI Marked) with accessories like Tee, bend etc with one run of 1100V grade FRLSH PVC insulated multistranded copper conductor cable 1.5 Sq mm single core green colour for earth continuity conductor and connecting to common earth dolly incl provn of modular GI sunken box of suitable size concealed on wall with modular cover plate and frame of suitable module for housing modular type switches / socket/ Fan regulator etc. complete including making good to the disturbed surfaces of wall/ceiling/floor in same specification as per existing complete all as specified and directed. |
| 37 | All as per item No. 35.00 here in before but for 3 pin 5 amps socket out let point on same board with other switches. |
| 38 | All as per item No. 35.00 here in before but for one 5 amp switchon independent board. |
| 39 | All as per item No. 35.00 here in before but using 2.5 sq mm size stranded copper conductor cable for one 16 amp switch socket outlet on independent board. |
| 40 | All as per item No. 35.00 here in before but for One Light point controlled by two, two way switches. |
| 41 | S&F switch piano modular one way 5/6 Amps 240V AC 1M complete all as specified |
| 42 | S&F switch piano modular two way 5/6 Amps 240V AC 1M complete all as specified |
| 43 | S&F modular bell push type 5 Amps 240V AC 1M complete all as specified |
| 44 | S&F modular socket out let 3 pin 5 Amps 240V AC 2M complete all as specified |
| 45 | S & F modular Socket outlet 3 pin, 16 Amps 240V AC 2M complete all as specified |
| 46 | S & F Modular switch 1 way 16A, 240V AC 1M complete all as specified |
| 47 | S&F in repairs modular metal sunken box of 1/2 module deep sunk in wall including making good distrubed surfaces complete all as specified and directed Note: The cost of cutting chasing of wall, if required and making good disturbed surface in CM (1:3) and finishing the surface to match with existing is deemed to be included in quoted rate. |
| 48 | All as per item No 46 here-in-before but for 3/4 modules. |
| 49 | All as per item No 46 here-in-before but for 6 modules. |
| 50 | All as per item No 46 here-in-before but for 8 modules |
| 51 | All as per item No 46 here-in-before but for 12 modules. |
| 52 | S/F, in repair, modular cover plate with frame for fixing of modular switches/sockets complete for 1/2 modules |
| 53 | all as per item no 51.00 above but for 3/4 modules |
| 54 | all as per item no 51.00 above but for 6 modules |
| 55 | all as per item no 51.00 above but for 8 modules |
| 56 | all as per item no 51.00 above but for 12 modules make havells cat no. AHXPLOWV12 or equivalent in legrand , anchor, chroma |
| 57 | Supply and fixing in repairs modular type switch 1 way 6Amp, 240Volts 1 module complete all as specified and directed |
| 58 | Supply and fixing in repairs modular type switch 2 way 6Amp, 240Volts 1 module complete all as specified and directed |
| 59 | Supply and fixing in repairs modular type bell switch 1 way 6Amp, 240Volts 1 module complete all as specified and directed |
| 60 | Supply and fixing in repairs modular type socket outlet 6Amp - 3 pin combined 2 module 240 volts AC complete all as specified and directed |
| 61 | Supply and fixing in repairs modular type socket outlet 16Amp - 3 pin combined 2 module 240 volts AC complete all as specified and directed |
| 62 | Supply and fixing in repairs modular type switch 1 way 16Amp, 240Volts 1 module complete all as specified and directed |
| 63 | S&F in repairs modular type Ceiling fan regulator electronic step type 240V 1/2 module complete all as specified and directed |
| 64 | S & F in repair Switch Socket Combination with polycarbonate box 6A 240V complete all as specified and directed |
| 65 | S & F in repair Switch Socket Combination with polycarbonate box 16A 240V complete all as specified and directed |
| 66 | Supply and fix in repair LED light 6W downlighter in cool day/ neutral white / warm white surface/recess mounted made up of Polycarbonate body complete with all the connection and making good to disturbed surface of the wall complete all as specified and directed. Make Crompton CDR-222-06-57-SL-NWH or equivalent |
| 67 | S&F in repair mini recess / surface mounted 40 watt LED panel 1 X 4 feet luminaire in cool day/neutral white/ warm white in powder coated housing complete incl connection & taking down old UNSV complete all as specified and as directed.Make : Bajaj cat part No. BCTBLR 18ZT WH or equivalent in philips/CG/surya |
| 68 | S&F in repairs energy efficient LED bed side light lamp 3 Watt in three colour option including dismantling complete all as specified. Model No. 48042/30/30 of Make Philips or equivalent in CG/Havells. |
| 69 | Supply and fixing in repair, LED lights fitting 1x 10W, 220V,AC wall mounted LED batten in warm white/cool day/natural white light with PVC housing & integrated electronic driver with min efficacy of 100lumen/W connecting up with flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 70 | Supply and fixing in repair, LED lights fitting 1x 20W, 220V,AC wall mounted LED batten with PVC housing & integrated electronic driver with min efficacy of 100 lumen/W connecting up with flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 71 | Supply and fixing in repair, LED light fitting 1x9W/1X10W bulkhead luminaires IP66 rated including LED light driver holder, Aluminium housing connecting up with three core flexible copper conductor cable of suitable size. |
| 72 | Supply and fixing in repair, LED luminaire 600 mm x 600 mm,35/36 watt, 220 V AC recessed/surface type cool day white/ neutral white / warm with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. |
| 73 | Supply and fixing in repair, Decorative wall light fixture made up of glass with PVC base having champgne gold finish base including 9 W LED Lamp B22 base complete with all the connection and making good to disturbed surface of the wall complete all as specified and directed. |
| 74 | Supply and fixing in repair, Decorative wall light fixture made up of glass with metal base having champgne gold finish base including for 9 W LED Lamp B22 base complete with all the connection and making good to disturbed surface of the wall complete all as specified and directed. Make Crompton WMAFBULB. or equivalent from approved make. |
| 75 | Supply and fixing in repair, Flameproof cum Waterproof LED Bulk Head light fitting of 30 W, IP66 protection of Cast Aluminum alloy material and Heat and Impact resistance toughen 'A' clear glass having Anti corrosive epoxy powder coated finish complete with all accessories pre wired and including connecting up with three core flexible copper conductor cable with suitable sizecomplete all as specified and as directed. |
| 76 | Supply and fixing in repair, wall washer stylish dual beam outdoor light 1 way cool day white/ neutral white/ warm white 10W IP 65 rated complete all as specified and directed. Make Philips Radiant outdoor wall washer or equivalent from approved make. |
| 77 | Taking down unserviceable rusted / damaged MCB DBs of any type and way along with any type MCB and making good to the distubed surfaces of walls etc. complete all as specified and as directed. |
| 78 | S&F in replacement factory made powder coated distribution board SPN, 4 ways, IS 8623, IEC 61439-3, double door, protection class IP-43, fabricated from CRCA sheet and fixed / flushed on wall suitable for universal mounting including 100 Amps bus bar, neutral bus bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable glands plates with knockouts required at site alongwith blanks including cutting of wall if required and making good disturbed surface in CM (1:3) and finishing the surface to match with existing surface etc complete all as specified and directed.Note :- (i) MCBs shall be measured and paid seperately.(ii) Cost of Lugs/ thimbles shall be deemed to be included in the quoted rates. |
| 79 | S&F in replacement factory made powder coated distribution board SPN, 8 ways, IS 8623, IEC 61439-3, double door, protection class IP-43, fabricated from CRCA sheet and fixed / flushed on wall suitable for universal mounting including 100 Amps bus bar, neutral bus bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable glands plates with knockouts required at site alongwith blanks including cutting of wall if required and making good disturbed surface in CM (1:3) and finishing the surface to match with existing surface etc complete all as specified and directed.Note :- (i) MCBs shall be measured and paid seperately.(ii) Cost of Lugs/ thimbles shall be deemed to be included in the quoted rates. |
| 80 | S&F in replacement factory made powder coated distribution board SPN, 12 ways, IS 8623, IEC 61439-3, double door, protection class IP-43, fabricated from CRCA sheet and fixed / flushed on wall suitable for universal mounting including 100 Amps bus bar, neutral bus bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable glands plates with knockouts required at site alongwith blanks including cutting of wall if required and making good disturbed surface in CM (1:3) and finishing the surface to match with existing surface etc complete all as specified and directed.Note :- (i) MCBs shall be measured and paid seperately.(ii) Cost of Lugs/ thimbles shall be deemed to be included in the quoted rates. |
| 81 | S&F in replacement factory made powder coated distribution board TPN, 4 ways, IS 8623, IEC 61439-3, double door, protection class IP-43, fabricated from CRCA sheet and fixed / flushed on wall suitable for universal mounting including 200 Amps bus bar, neutral bus bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable glands plates with knockouts required at site alongwith blanks including cutting of wall if required and making good disturbed surface in CM (1:3) and finishing the surface to match with existing surface etc complete all as specified and directed.Note :- (i) MCBs shall be measured and paid seperately.(ii) Cost of Lugs/ thimbles shall be deemed to be included in the quoted rates. |
| 82 | S&F in replacement sheet metal enclosure distribution board TP&N, 8 way, double door, powder coated, protection class IP-42, suitable for mounting MCB, DBs confirming to IS-13032, IS-8632, BS-5484 with min 200 Amp rating copper bus bar incl blanking plate complete all as specified & directed.Note:- (i) MCBs shall be measured and paid seperately.(ii) Cost of thimbles for connecting cable to MCCBs/MCB and making good disturbed surface is included in this item and nothing will be paid extra on this account. |
| 83 | S&F in repair, MCB 6 to 32 amps 'C' curve, single pole complete all as specified. |
| 84 | S&F in repair MCB DP 40 to 63 amps 'C' curve, 240 volts 10KA breaking capacity complete all as specified. |
| 85 | S&F in repair, MCB TPN / FP 63-100 Amps 'C' curve 415 Volts FP with rapturing capacity 10KA including taking down of old one complete all as specified. |
| 86 | S&F in repairs plug and socket in sheet metal enclosures with two pin and earth plug and socket including MCB SP 20 Amps 240 volts heavy duty and making good to disturbed surfaces completre all as specified and as directed . |
| 87 | S&F in repairs A C starter unit consisting of one 20 Amp capacity starter 2M modular box, cover plate & frame.Make : IndoAsian/ anchor/crabtree/havells / Legrand complete as specified. |
| 88 | S&F in repairs A C starter unit consisting of one 25 Amp capacity starter, one 240 V 25 Amps 10 KA SPN MCB, one 25 Amps socket and one 25 Amps plug top prewired with 6M modular box, cover plate & frame and taking town of old UNSV one of Make : North West Cat No. ACPU6M-BT or Havells Cat No. Havells DHDUCDP0253016-25 / anchor/crabtree/havells / Legrand complete as specified after taking out old unserviceable starter unit all as directed. |
| 89 | Taking down aluminimum sub mainwiring alongwith damaged casing capping /PVC conduit/ concealed conduit pipe from the wall roof or in floor and making good disturbuted surfaces complee all as directed. |
| 90 | S&FSub main wiring with two single core cable PVC insulated unsheathed of copper multi stranded conductor FRLS cable of size 4 sqmm, 1100 votls grade drawing through and including rigid PVC concealed conduit 25 mm dia medium duty including acessories such as Tee, bend, Elbow etc, ISI marked with and including PVC insulated 4 sqmm unsheathed multistranded FRLS copper conductor cable for earth continuity and connected to common earth dolly including cutting chasing of wall, if required and making good disturbed surface in CM (1:3) and finishig the surface to match with existing surface, etc complete all as specified and directed by Engineer-in-charge. Note : (i) Two run of single core cable 4 sq mm and one run earth wire 4 sq mm will be measured as one length. |
| 91 | S&F Sub main wiring with two single core cable PVC insulated unsheathed of copper multi stranded conductor FRLS cable of size 6 sqmm, 1100 votls grade drawing through and including rigid PVC concealed conduit 32 mm dia medium duty including acessories such as Tee, bend, Elbow etc, ISI marked with and including PVC insulated 6 sqmm unsheathed multistranded FRLS copper conductor cable for earth continuity and connected to common earth dolly including cutting chasing of wall, if required and making good disturbed surface in CM (1:3) and finishig the surface to match with existing surface, etc complete all as specified and directed by Engineer-in-charge.Note : (i) Two run of single core cable 6 sq mm and one run earth wire 6sq mm will be measured as one length. |
| 92 | S&F Sub main wiring with two single core cable PVC insulated unsheathed of copper multi stranded conductor FRLS cable of size 10 sqmm, 1100 votls grade drawing through and including rigid PVC concealed conduit 32 mm dia medium duty including acessories such as Tee, bend, Elbow etc, ISI marked with and including PVC insulated 6 sqmm unsheathed multistranded FRLS copper conductor cable for earth continuity and connected to common earth dolly including cutting chasing of wall, if required and making good disturbed surface in CM (1:3) and finishig the surface to match with existing surface, etc complete all as specified and directed by Engineer-in-charge.Note : (i) Two run of single core cable 10 sq mm and one run earth wire 10 sq mm will be measured as one length. |
| 93 | Materials and labor for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI strip 32 x 6 mm as earthing lead by means of bolts, nuts, check nuts and washers of GI or steel, light to earth test point protected by 40mm dia GI pipe as directed including funnel with watering pipe 20 mm bore light grade galvanised iron, wire mesh, charcoal or coke common salt laid in alternative layer of 15 cm (complete thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1, 50 mm thick pre-cast RCC (1:2:4) type B-1 normal mix cover slab reinforced with 8 mm dia TMT bar 10 cm c/c bothways and single handle of 10 mm dia round bar including necessary excavation, earth work etc. in soft / loose soil and disposal pf soil to a distance n. exc. 50 m and necessary testing on completion all as shown in electrical plate No. 3 MES Schedule Part-I complete all as specified and as directed . |
| 94 | All as per item 92 here in before but using GI strip 25x 4mm protected by 32 mm dia GI pipe, light grade complete all as specified and as directed . |
| 95 | All as per item 92 here in before but using GI wire of 4mm dia protected by 15 mm GI pipe light grade complete all as specified and as directed . |
| 96 | M & L for earth continuity conductor or main earthing lead fixed on porcelain insulator on wall/floor/ any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire complete all as specified and as directed . |
| 97 | M&L for 25 x 3.15 mm aluminium strip burried in ground/fixed on wall ,roof on porcelain insulator using screws etc., for roof conductors and down conductors above ground after taking down old one complete all as specified and as directed |
| 98 | M&L for Air termination,single pointed Al rod 12mm dia and 300mm long complete all as specified and as directed |
| 99 | M&L for Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm,drilled and screwed including 3nos 8mm dia 25mm long hex. Head screw and taking down existing unserviceable/worn out complete all as specified and as directed by engineer in charge. |
| 100 | M & L for double layer self supporting steel scafolding to external perimeter of building duly cross braced and properly aligned for the functional aspect and safety of both workers and the building, length 2m and height upto G+9 complete all as specified and directed |
| 101 | S&F in repair 20 mm dia PVC conduit, medium grade with all fixing accessories incl taking down old unserviceable one complete all as specified and as directed. |
| 102 | S&F in repair 25 mm dia PVC conduit, medium grade with all fixing accessories incl taking down old unserviceable one complete all as specified and as directed. |
| 103 | S & F repairs casing capping 20mm in size with all accessories including taking down old unserviceable one complete all as directed. Make- prestoplast |
| 104 | Supply & fix in repairs 1.5sqmm FRLSH flexible PVC insulated single core unsheathed industrial multistrand Copper conductor cables complete all as specified and as directed. |
| 105 | Supply & fix in repairs 2.5sqmm FRLSH flexible PVC insulated single core unsheathed industrial multistrand Copper conductor cables complete all as specified and as directed. |
| 106 | S&F building security light pressure die cast housing with individual LEDs with modular secondary optics security light luminaires 35 watt LED with 32 mm dia light grade GI pipe bent to shape of 45 degree, 1.5 mtr long and nuts bolts including fixing arrangement after taking down old unserviceable one complete all as specified and as directed. |
| 107 | Supply only metal clad plug Socket 20 Amp (enclosure type) suitable to fix in sheet and metal enclouser for geyser, all as specified and directed by Enge in charge.Make:-Havells/HPL/Benlo |
| 108 | Supply only metal clad plug top 20A (enclosure type) suitable to fix in sheet and metal enclouser for geyser, all as specified and directed by Enge in charge.Make:-Havells/HPL/Benlo |
| 109 | S&F in replacement 3mm thick laminated sheet for housing switches for required size including drilling holes for fixing complete all as specified and directed.. |
| 110 | Supply and fix in repairs /replacement of self adhesive PVC Electrical Insulation tape of size 1.8cmx6.5mx0.125mm mix colour box in a packet of 12 roll complete all as specified and dircted. Note- Insulation tape should be ISI marked. |
| 111 | Supply & fix in repairs PVC cover plate suitable for fixing on junction covers of size minimum 2 inch dia of superior quality as specified and directed Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 30, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedNov 21, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 21 daysNov 23, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 23 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender