Defence Statutory Bodies & Commissions/Committees Closing in 21 days TDR #58294180

Tender For Provn Of 240Kw Power Supply For Fast Charger At Mt Section Of Hq Swac

Issued by Statutory Bodies & Commissions/Committees · Gandhinagar, Gujarat
Tender Value
29.09 Lakhs
Estimated cost
Bid Submission
21 Nov 2026
21 days left
EMD
58180
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Gandhinagar → Gujarat
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provn Of 240Kw Power Supply For Fast Charger At Mt Section Of Hq Swac

BOQ

Name of Work:- PROVN OF 240KW POWER SUPPLY FOR FAST CHARGER AT MT SECTION OF HQ SWAC
Sl. No. Item Description
1Supply, installation, commisioning and testing factory made and tested, CPRI approved, LT Panel (KISOK), outdoor type, mounted on rigid angle iron frame, suitable size, having independent compartment for insulated Aluminium bus bar, incoming feeder and each out going feeder, dust and vermin proof, factory made, fabricated out of not less than 3.15 mm thick CRCA sheet suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with aluminium bus bar of 1000 Amp rating for 3 phase and neutal 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators - 01 Set, common earth bus bar of GI Strip 32 x 6 mm at bottom with panel board at two earth terminals , cable glands with independent plates at bottom for each out going and in coming cables in cable alley and complete board painted with powder coating in siemens grey colour front & rear opening type with double door shutter and locking arrangement including provision of 65 mm Godrej (freedom) lock with 2 keys, suitable aprons for cable entry/exist including taking down and refixing of exisiting cable properly with lug and thimable, Rate including for removal and taking out existing old/rusted LT Panel board of any type any size complete all as approved & complete all as specified and as directed by Engineer- in-Charge and comprising as under: -Incoming :-(i) 800A FP 50 KA EDO MICRO ACB (U - POWER) - 01 No (ii) Under Voltage Release (UVR) 240V AC- 01 No.(iii) Digital MFM Metering, Multifunction Meter. -01 No. (iv) R-Y-B indicating lamps - 01 set. (v) Control fuse -04 Nos.(vi) CT -03 Nos(vii)CT Short link - 04 Nos(viii)6A SP 'C' MCB - 08 Nos(ix) E- STOP Push button - 01 No(x) R-G-O Indication Lamp - 01 No(xi) Selector Switch 1 P 2 W 6A - 01 No(xii) TNC Breaker Control Switch 25 A (1 NO + 1 NC) - 1 No(xiii)On Delay Timer 0.3 Sec-30 Hrs (MICON 175) 240 - 415 VAC - 01 No
2Out going :- (i) 630A FP 50 KA EDO MICRO ACB (U - POWER) - 02 Nos(ii) Under Voltage Release (UVR) 240V AC- 02 Nos.(iii) Digital MFM Metering, Multifunction Meter. -02 Nos. (iv) R-Y-B indicating lamps - 02 set. (v) Control fuse -08 Nos.(vi) CT -06 Nos(vii) CT Short link - 08 Nos(viii)6A SP 'C' MCB - 16 Nos(ix) E- STOP Push button - 02 Nos(x) R-G-O Indication Lamp - 02 Nos(xi) Selector Switch 1 P 2 W 6A - 02 Nos(xii) TNC Breaker Control Switch 25 A (1 NO + 1 NC) - 02 Nos(xiii) On Delay Timer 0.3 Sec-30 Hrs (MICON 175) 240 - 415 VAC - 02 Nos(xiv) CRYO CC-510-B1-01-R _ 01 No(xv) Door Limit Switch With Light - 03 Nos(xvi) Cooling Fan 6 x 6 - 02 Nos(xvii) Angle iron base frame as reqd size as per above panel, total leg height 600 mm and grouting in side PCC 150 mm legs and made out of ISA5050, 50 x 50 x 6 mm thick angle iron duly painted - 01 No.(xviii) M & L for necessary excavation and as reqd PCC 1:3:6 (40 mm graded aggregate) Type C2 for foundation of angle iron legs frame work complete - 01 job
3Excavation in trenches not exceeding 1.5m width and not exceeding 1.5 m in depth and getting out in soft/loose soil for taking up/laying cable/pipe etc complete all as specified and as directed by Engineer- in-Charge.
4Returning , filling in trenches, including spreading , levelling , watering and well ramming in layers not exceeding 25 cm in Soft/loose soil complete all as specified and as directed by Engineer- in-Charge.
5Removal of excavated material at a distance not exc 50 mtr and dipositing where directed at a level not exc. 1.5 mtr above the starting point in Soft / loose soil complete all as specified and as directed by Engineer- in-Charge.
6Supply and laying dry Sand cushioning to underground cable with screened, washed river sand, including punning gently all as specified and directed.Note : - Thickness after punning will be measured for payment.
7Supplying and laying reinforced precast concrete cable cover, class LV, Type 1, flat, size 250 mm x 150mmx 40mm complete all as specified and directed by Engineer in charge.
8Supply and lay and testing cable LT XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with standerd aluminum conductor, 1100 Volts grade, of size 400 Sqmm 3.5 Core complete all as specified and as directed by Engineer- in-Charge.Note: - Excavation, earthwork, will be measured and paid separately under respective items of this Schedule.
9Supply and Fixing PVC insulated unsheathed, multi stranded FRLS copper conductor flexible cable 1100 volt grade of size 185 Sqmm single core. laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing complete all as specified and as directed by Engineer- in-Charge.
10Supply and Fixing PVC insulated unsheathed, multi stranded FRLS copper conductor flexible cable 1100 volt grade of size 50 Sqmm single core. laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing complete all as specified and as directed by Engineer- in-Charge.
11M & L for chemical Earthing complete with copper earth plate 90 cm x 60 cm x 5 mm burried directly in ground vertically to a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level connected to and including copper earth strip of 32X6mm dia by means of bolts,nuts, check nuts and washer etc made of galvanised iron and connected to earthing test point all as shown in electrical plate No.3 of SSR Part I 2009 and as specified or indicated and testing on completion including excavation/earth work in any type of strata. PCC (1:3:6) type C1 earthing chamber, precast RCC slab 50 mm thick in reinforced cement concrete (1:2:4) type B1 reinforced with welded steel wire fabric (XPM jali weight not less than 4 Kg/Sqm), cast iron frame, funnel with wire mesh, 40 mm bore medium grade GI watering pipe, lugs, 15 mm bore medium grade GI protection pipe, test point etc. complete all as specified and as directed by Engineer- in-Charge.Note: -(i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. Any addition in length shall be adjusted through deviation order.
12M & L for maintenance free Chemical earthing of technology with copper bonded steel rod 2 mtr long 50.0 mm dia with 250-micron Copper bonded coating and UL listed. There should be terminal for connection of 200 x 40 x 6 mm with 4 holes of 12 mm dia along with 2 bags of 25 Kgs each of earth enhancing compound. The chemical compound should be tested and certified by any NABL accredited laboratory with 95 percent carbon content. The testing laboratory should be an ISO 9001 and 14001 certified. The earth enhancing compound should be IEC 62321. The ph value of compound should be 7-8. Electrode should be duly tested and certified by CPRI, Govt of India for a min short circuit current of 25 kA rms for 1 Sec. including necessary boring of suitable dia upto required depth in any type of soil for inserting copper rod and filling of chemicals and Poly plastic pit cover of material- polymer body & cover dimensions- 308 mm (L) x 308 mm (W) x 214 mm (H) bearing capacity 7.5 Ton approved from NABL approved Lab complete all as specified and as directed by Engineer- in-Charge.Note:- (i) Earthing is to be done infront of the Engr-in-Charge.(ii) Test Results of earthing to be submitted by the contractor for all earthings.(iii) Failing to maintain resistance of earthing less than 01.0 ohm , new earthing to be provided by the contractor with out any extra cost.(iv) Necessary earth work, excavation shall be carried out in any type of soil strata, retuning, filling in and making good surronding area complete. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 58294180
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 29.09 Lakhs
LAST DATE 21-11-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provn Of 240Kw Power Supply For Fast Charger At Mt Section Of Hq Swac
Basic Detail
Tender No 8532/26-27/E8
Bidding Type Tender
Location
City Gandhinagar
State Gujarat
Key Dates
Publish Date 30 Oct 2026
Submission Date 21 Nov 2026
Open Date 23 Nov 2026
Finance
Tender Value 29.09 Lakhs
Tender Fee 500
EMD 58180
Exemption Available
Document List
1c35b426-b7c6-4b5d-965e-1d9a69e695ff.html
BOQ_893533.xls
Tenderdocuments8532.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 30, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 21 days
Nov 23, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 23 days

Tender Documents

Download All (ZIP) ↓
html

1c35b426-b7c6-4b5d-965e-1d9a69e695ff.html

xls

BOQ_893533.xls

pdf

Tenderdocuments8532.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender